| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | ₹15.0 L Quoted ₹16.2 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹18.6 L+₹2.4 L (15.0%)Rejected-Finance | ₹18.6 L+₹2.4 L (15.0%) | L2 | Rejected-Finance Higher than L1 Bidder |
| 3 | L3₹19.4 L+₹3.2 L (19.9%)Rejected-Finance | ₹19.4 L+₹3.2 L (19.9%) | L3 | Rejected-Finance Higher than L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
31 Oct 2020, 6:00 pmClosed
MAJ JYOTI PRAKASH SAHOO
GE 872 EWS, C/O 99 APO
REPAIRS/MAINT TO INTERNAL ELECTRIFICATION, REPAIRS/ MAINT/ SERVICING TO VARIOUS TYPES OF FANS AND GEYSER AND REPAIRS/ MAINT/ SERVICING TO COOLING APPLIENCES, REPAIRS/ MAINT OF EXTERNAL WATER SUPPLY, REPAIRS/ MAINT TO LT EXTERNAL ELECTRIFICATION AND R
2020_MES_373970_2
8825/T-25/E8
Open Tender
Miscellaneous Works
Item Rate
213 days
NLP
All as per NIT and Tender Documents
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹29,000
Yes
4 Jan 2021
13 Oct 2020
2 Nov 2020
13 Oct 2020
31 Oct 2020
19 Oct 2020
13 Oct 2020 - 15 Oct 2020
Amount
REPAIRS/MAINT TO INTERNAL ELECTRIFICATIONS
M&L Taking down carefully Copper/Aluminium Point Wiring (Light, Fan, Socket or Power) complete from in any position including Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fittings, etc., Making Good disturbed surfaces of Walls/ Ceillings, etc in Cement Mortar 1:3 including providing Surface Treatment (Colour Washing/ Distempering/ Painting) wherever required to match the Existing Finishes, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/ BELL POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE FAN POINT controlled by One 1-way Switch 6 Amp/Fan Regulator, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3/5 PIN SOCKET 6 AMP POINT on INDEPENDENT BOARD, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire for ONE 3/5 PIN SOCKET 6 AMP POINT on SAME BOARD, complete all as specified and as directed.
M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3 PIN SOCKET OUTLET 16 AMP POINT on INDEPENDENT BOARD, complete all as specified and all as directed.
S&F PVC Casing Capping (ISI Marked) of size 25mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out unserviceable PVC Casing Capping, complete all as specified and as directed.
S&F PVC Casing Capping (ISI Marked) of size 32mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out unserviceable PVC Casing Capping, complete all as specified and as directed
S&F PVC Rectangular Block of size 175x100x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed.
S&F PVC Rectangular Block of size 200x150x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed.
S&F Switch Piano Flush type, 6 Amp, Single Pole, 1-way, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Switch Piano Flush type, 6 Amp, Single Pole, 1-way, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch Piano, complete all as specified and as directed.
S&F Switch Socket Outlet 3 Pin, 6 Amp, Flush type and connecting up, complete all as specified and as directed.
S&F Switch Socket Outlet 5 Pin, 6 Amp, Multi-Plug, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Switch Socket Combination 5 Pin, 6 Amp, Multi-Plug, Flush type, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch Socket Combination, complete all as specified and as directed.
S&F Switch Socket combination 5 Pin, 6/16 Amp, Multi-Plug, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Switch Socket combination 5 Pin, 16 Amp, Multi-Plug, Flush type, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch Socket Combination, complete all as specified and as directed.
S&F Pendant Holder Ordinary with Insulated Body Lamp Holder and connecting up, complete all as specified and as directed.
S&F Ceiling Rose Surface type, Bakelite 65x50mm 2 to 3 Terminal suitable for 230 Volt AC, 6 Amp and connecting up, complete all as specified and as directed.
S&F Ceiling Fan Regulator 230 Volt AC, Rotary Stepped Electronic type 120/280 Volt including necessary Connection and connecting up, complete all as specified and as directed.
S&F Ceiling Fan Regulator 230 Volt AC, Rotary Stepped Electronic type 120/280 Volt and connecting up including Taking down/ out unserviceable Fan Regulator, complete all as specified and as directed.
S&F LED Bulb 10 Watt suitable for fixing in Normal Pendent/Batten Holder, 230 Volt including Taking down/ out unserviceable Bulb, complete all as specified and as directed. MAKE : HAVELLS
S&F LED Batten 18 Watt 4 Feet Cool Day Light including Taking down/ out unserviceable Batten, complete all as specified and as directed. MAKE : CROMPTON/ HAVELLS/ PHILIPS/ WIPRO
S&F MCB Single Pole 6 to 32 Amp, 'C' Series 10 kA Breaking capacity, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F MCB Single Pole 40 to 63 Amp, 'C' Series 10 kA Breaking capacity, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F MCB Distribution Board, SPN 2-way, 240 Volt AC, Double Door type of Steel Phoshotised Powder painted with 200 Amp Neutral Bars, Earth Bar and connecting up including Taking down/out unserviceable MCB DB, complete all as specified and as directed. MAKE : HAVELLS or equivalent Model of LEGRAND/ L&T
S&F MCB Distribution Board, SPN 4-way, 240 Volt AC, Double Door type of Steel Phoshotised Powder painted with 200 Amp Neutral Bars, Earth Bar and connecting up including Taking down/out unserviceable MCB DB, complete all as specified and as directed. MAKE : HAVELLS or equivalent Modal of LEGRAND/ L&T
REPAIRS/MAINT TO FANS
M&L Taking down unserviceable Ceiling Fan, Exhaust Fan, Wall Mounted Fan, Air Circulator Fan of any Make & Size after disconnecting and removing to AGE E/M Store Yard at NLP for Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Re-hanging the same in Original Position after repaired and providing Electric Connection, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involved to make the Fan completely Functional, even if not notified by the Board of Officers, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Rewinding & Other Parts required to be replaced will be Measured and Paid separately as "S&F"/"M&L" under relevant Items.
S&F Ball Bearing (size as per existing one/ as approved) suitable for Ceiling Fan 1200/1400mm Sweep including Taking down/out unserviceable Ball Bearing, complete all as specified and as directed. MAKE : FAG/ NBC/ SKF
S&F Condenser 2.0/2.5 mfd suitable for Ceiling Fan of any Make and Size including Taking down/out unserviceable Condenser, complete all as specified and as directed.
S&F Condenser 3.15/4.0 mfd suitable for Exhaust Fan of any Make and Size including Taking down/out unserviceable Condenser, complete all as specified and as directed.
S&F Fan Blade Aluminium (size as per existing one/ as approved) suitable for Ceiling Fan 1200mm Sweep of any Make/Model, Aero dynamically Balanced and Screwed with suitable size Mild Steel Screws including Taking down/out unserviceable Fan Blade, complete all as specified and as directed.
S&F Gun Metal Bush (size as per existing one/ as approved) suitable for Cabin/ Ceiling/ Exhaust Fan of any Make and Model including Taking down/out unserviceable Bush, complete all as specified and as directed. MAKE : FAG/ NBC/ SKF
M&L Transporting Ceiling Fan 1200mm Sweep from AGE E/M Store Yard at NLP to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Exhaust Fan 300/ 380mm Sweep from AGE E/M Store Yard at NLP to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Wall/ Cabin Fan 400mm Sweep from AGE E/M Store Yard at NLP to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
REPAIRS/MAINT TO GEYSERS
M&L Taking/Lowering down unserviceable Electric Water Heater (Geyser) 25 Litre capacity, Storage type from any Situation after disconnecting all Water Supply & Electric Connections and carry out following Checks :- (a) Inspection of Geyser and Opening, Dismantling, Brushing and Cleaning of Storage Water Tank, Removing all Sludge, Scalling and Bleaching from the Tank and Examining of any leakage of Water, Tightening of Nuts, Bolts and Re-installation the same in Original Position complete. (b) Check and Connecting Earth Continuity to Electric Water Heater. (c) Checking and Adjusting of Pressure Release Valve. (d) Check and Maint of Thermostate Valve. (e) Visual Examination of Fusible Plug.
M&L Taking down Electric Water Heater 25 Litre capcity of any Make/ Model by carefuly Un-bolting, Dismantling the Electric Water Heater, Taking out the Aparatus Assembly, Inner Tank, Glass wool, Thermostats, Checking the Point of any leakages on Inner Tank, Brazing for Removing of Leakage, Re-assembling the Electric Water Heater and Re-fixing of Appratus Assembly including Replacing of Glass wool, Re-installation Electric Water Heater in Original Position, Providing all Electrical & Water Supply Connections and Testing, complete all as specified and as directed.
S&F Base Assembly Gasket of any shape and size, suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out unserviceable Base Assembly Gasket, complete all as specified and as directed.
S&F Base Assembly (Inner), Brass Chromium plated complete of any shape and size with Inlet, Outlet, Thermostate Slot, drain plug, Clamp or Bolts to fixing Heating Element as existing Shape suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out unserviceable Base Assembly (Inner), complete all as specified and as directed.
S&F Brass Chromium plated Connection 350mm long with Brass Chromium plated Adaptor and Making connection to Inlet & Outlet suitable for Electric Water Heater 25/50 Litre capacity of any Make/Model including Taking down/ out unserviceable Connection with Adaptor, complete all as specified and as directed.
S&F Fusible Plug in existing Shape suitable for Electric Water Heater 25 Litre capacity of any Make/Model and Testing including Taking down/out unserviceable Fusible Plug, complete all as specified and as directed.
S&F Glass Wool (Insulation Materials) superior quality (as approved) suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking out unserviceable Glass Wool, complete all as specified and as directed.
S&F Heating Element 1.5 KW 230 Volt AC suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out unserviceable Heating Element, complete all as specified and as directed.
S&F Heating Element 2.0 KW 230 Volt AC suitable for Electric Water Heater 50 Litre capacity of any Make/Model including Taking down/out unserviceable Heating Element, complete all as specified and as directed.
S&F Indication Lamp Assembly consisting Red & Green in Colour of any shape and size, 230 Volt suitable for Electric Water Heater 50 Litre capacity of any Make/Model including Taking down/out unserviceable Indication Lamp, complete all as specified and as directed.
S&F PVC Connection in Inlet, 15mm bore (dia) & 450mm in length with PTMT Nuts suitable for Cold/Hot Water including Taking down/out unserviceable PVC Connection, complete all as specified and as directed.
S&F Safety Valve, ISI marked suitable for Electric Water Heater 25 Litre capacity of any Make/ Model including Taking down/out unserviceable Safety Valve, complete all as specified and as directed.
S&F Thermostate Switch with Thermal Setting 40 °C to 90 °C capacity and Relay 240 Volt AC suitable for Electric Water Heater 25/50 Litre capacity of any Make/Model including Taking down/out unserviceable Thermostate Switch, complete all as specified and as directed.
REPAIRS/MAINT TO SPLIT TYPE AC 1.5 TON/ 2.0 TON CAPACITY
M&L Compressor Rotary type (as per Existing One/ as approved) to match the Same Model & Capacity suitable for Split AC 2.0 Ton Capacity with All Accessories including necessary Gas Charging, Welding, Brazing to Stop Leakage & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : CARRIER/ HITACHI/ KIRLOSKAR/ TECUMSEH
M&L Copper Pipe 1/2" (as per Existing One/ as approved) to match the Same Model & Capacity AC with necessary Connection & Testing including Taking down/ out unserviceable Pipe, complete all as specified and as directed.
M&L Copper Pipe 5/8" and 3/8" (as per Existing One/ as approved) to match the Same Model & Capacity AC with necessary Connection& Testing including Taking down/ out unserviceable Pipe, complete all as specified and as directed.
M&L Flare Nut made out of Brass for Copper pipe 1/2"/ 3/8" (as per Existing One/ as approved) including Taking down/ out unserviceable Nut, complete all as specified and as directed.
M&L Fan Blade Assembly, Heavy duty for Fan Motor (as per Existing One/ as approved) suitable for Split type AC 1.5 Ton/ 2.0 Ton Capacity and providing necessary Connections & Testing including Taking down/out unserviceable Fan Blade Assembly, complete all as specified and as directed. MAKE : CARRIER/ FEDDERS LLOYED/ VOLTAS
M&L Indoor Motor, Single Phase, 230 Volt (as per Existing One/ as approved) to match the Same Model & Capacity suitable for Split type AC 1.5 Ton/ 2.0 Ton Capacity and providing necessary Connections & Testing including Taking down/ out unserviceable Condensor Fan Blade Assembly, complete all as specified and as directed. MAKE : AUE/ USHA or equivalent as approved by GE
M&L Insulation On & Around Suction and Discharge Copper Piping with 6.0mm thick Flexible Thermocool Heat Resistant duly scrapped with Sticking Tape & Testing including Taking down/ out unserviceable Insulation, complete all as specified and as directed.
M&L Power Circuit (PC) Plate (as per Existing One/ as approved) suitable for Split type AC 1.5 Ton and providing necessary Connections & Testing including Taking down/out unserviceable Power Circuit, complete all as specified and as directed.
M&L Power Circuit (PC) Plate (as per Existing One/ as approved) suitable for Split type AC 2.0 Ton and providing necessary Connections & Testing including Taking down/out unserviceable Power Circuit, complete all as specified and as directed.
M&L Power Circuit PVC Plate (as per Existing One/ as approved) suitable for Split type AC 1.5 Ton and providing necessary Connections & Testing including Taking down/out unserviceable Power Circuit Plate, complete all as specified and as directed.
M&L Power Circuit PVC Plate (as per Existing One/ as approved) suitable for Split type AC 2.0 Ton and providing necessary Connections & Testing including Taking down/out unserviceable Power Circuit Plate, complete all as specified and as directed.
M&L Sensor Set Dry Cool (as per Existing One/ as approved) suitable for Split type AC 1.5 Ton/ 2.0 Ton and providing necessary Connections & Testing including Taking down/out unserviceable Sensor Set, complete all as specified and as directed.
M&L Shifting Split type AC 1.5 Ton/ 2.0 Ton Capacity Outer Unit with All Accessories including necessary Gas Charging, Welding, Brazing to Stop Leakage Vacum Test Pressure, Testing, insisting thick Flexible Thermocool and Servicing of Indoor and Outdoor Unit, complete all as specified and as directed.
Supply & Charging Gas F-22 to Split type Air Conditioner 2.0 Ton Capacity including necessary Servicing, Brazing to Stop the Leakage of required Pressure & Testing, complete all as specified and as directed.
M&L Dismantling Voltage Stablizer of capacity 3.0 KVA having Input Rating 135-290 Volts including Transformer Copper wound, Relays Contact Point, Wiring with Replacement of Volt Meter, Repairs to Transformer, Replacement of Relays, Assembling the complete & Testing, complete all as specified and as directed.
M&L Dismantling Voltage Stablizer of capacity 5.0 KVA having Input Rating 135-290 Volts including Transformer Copper wound, Relays Contact Point, Wiring with Replacement of Volt Meter, Repairs to Transformer, Replacement of Relays, Assembling the complete & Testing, complete all as specified and as directed.
REPAIRS/MAINT TO REFRIGERATORS
M&L Opening Refrigerator/ Freeze 310/322 Litre Capacity, Re-assembling/ Re-fixing the Same after Flushing Out and Removal of Blockage, necessary Brazing, Replacement of Liquid Line Filter and Recharging the Refrigerator with Freon-12 Refrigerant to obtain the desired Cooling (Temperature) & Testing, complete all as specified and as directed.
M&L Chilled Freezer Tray Plastic Complete (as per Existing One/ as approved) suitable for Refrigerator 310/ 322 Litre Capacity including Taking down/ out unserviceable Chilled Freezer Tray, complete all as specified and as complete all as specified and as directed. MAKE : KELVINATORS/ LG/ SAMSUNG
M&L Door Gasket, Magnetic type (as per Existing One/ as approved) suitable for Refrigerator 310/ 322 Litre Capacity including Taking down/ out unserviceable Door Gasket, complete all as specified and as complete all as specified and as directed. MAKE : KELVINATORS/ LG/ SAMSUNG
M&L Freeze Assembly Complete (as per Existing One/ as approved) suitable for Refrigerator 310/ 322 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Freeze Assembly, complete all as specified and as directed.
M&L Hermetically Sealed Compressor (as per Existing One/ as approved) suitable for Refrigerator 310/ 322 Litre Capacity, Model 043, Providing necessary Connections & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : KIRLOSKER/ TECHUMSHEH/ WHIRLPOOL
M&L Over Load Protector 1/6 HP Capacity (as per Existing One/ as approved) suitable for Refrigerator of any Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Over Load Protector, complete all as specified and as directed. MAKE : HITECH/ RENUTRAL/ USHA
M&L Pigmy Lamp 15 Watt, 230 Volt AC (as per Existing One/ as approved) suitable for Refrigerator of any Capacity & Testing including Taking down/ out unserviceable Lamp, complete all as specified and as directed. MAKE : CROMPTON/ PHILIPS
M&L Plastic PVC Tray (as per Existing One/ as approved), Supior quality of Large size withPVC Separator complete, suitable for Refrigerator of any Capacity & Make including Taking down/ out unserviceable PVC Tray, complete all as specified and as directed. MAKE : KELVINATORS/ LG/ SAMSUNG
M&L Relay Open type, 1/8 HP (as per Existing One/ as approved) suitable for Refrigerator of any Capacity & Testing including Taking down/ out unserviceable Relay, complete all as specified and as directed. MAKE : HITECH/ RENUTRAL/ USHA
M&L Relay Open type, 1/6 HP (as per Existing One/ as approved) suitable for Refrigerator of any Capacity & Testing including Taking down/ out unserviceable Relay, complete all as specified and as directed. MAKE : HITECH/ RENUTRAL/ USHA
M&L Vegetable Tray made out of Plastic Complete (as per Existing One/ as approved) suitable for Refrigerator 310/ 322 310 Litre Capacity including Taking down/ out unserviceable Vegetable Tray, complete all as specified and as directed. MAKE : KELVINATORS/ LG/ SAMSUNG
REPAIRS/MAINT TO DEEP FREEZER/ WATER COOLERS
M&L Capacitor 10 mfd Capacity suitable for Water Cooler 40/80 Litre or 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Capacitor, complete all as specified and as directed. MAKE : ASAIN/ KEL/ SPEED/ UNISTAR
M&L Starting Capacitor 40/80 mfd suitable for Water Cooler 40/80 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Starting Capacitor, complete all as specified and as directed. MAKE : ASAIN/ EPCOS/ SPEED/ UNISTAR
M&L Fan Blade Assembly Complete, Heavy duty (as per Existing One/ as approved) suitable for Water Cooler 40/80 Litre & 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Fan Blade Assembly, complete all as specified and as directed. MAKE : SIDHWAL/ USHA/ VOLTAS
M&L Fan Motor 1/35 HP or 1/32 HP Capacity (as per Existing One/ as approved) suitable for Water Cooler 40/80 Litre & 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Fan Motor, complete all as specified and as directed. MAKE : AUE/ CROMPTON
M&L Hermetically Sealed Compressor Unit (as per Existing One/ as approved), Single Phase suitable for Water Cooler 40/80 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : KIRLOSKAR/ SHRIRAM/ TECHEMSHAH
M&L Over Load Protector 2613 (as per Existing One/ as approved) suitable for Water Cooler of any Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Over Load Protector, complete all as specified and as directed. MAKE : HITACHI/ TECHEMSHAH
M&L Starting Kit comprising of Relay & Over Load Protector (as per Existing One/ as approved) suitable for Water Cooler 40/80 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Starting Kit, complete all as specified and as directed. MAKE : RENUTRAL/ SHRIRAM
M&L Thermostatic Switch (as per Existing One/ as approved) suitable for Water Cooler 40/80 Litre & 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Thermostatic Switch, complete all as specified and as directed. MAKE : GODREJ/ INDOFOSS/ RENUTRAL
M&L Denting, Welding to Water Cooler 40/80 Litre Capacity including applying Two Coats of Synthetic Enameled Paint (1st quality/ grade) over a Coat of red Oxide Zinc Chrome Primer with Spray Painting Machine after necessary Preparation of Surfaces including Sencil Writing MES No. with Paint, complete all as specified and as directed.
Supply & Charging Gas F-12 to Water Cooler 40/80 Litre Capacity including necessary Servicing, Brazing to Stop the Leakage of required Pressure and Testing, complete all as specified and as directed.
Supply & Charging Gas F-12 to Deep Freezer 320 Litre Capacity including necessary Servicing, Brazing to Stop the Leakage of required Pressure and Testing, complete all as specified and as directed.
M&L PVC Drain Pipe 32mm bore (dia), Heavy duty of Length 1.00 Metre with 2 Nno. Galvanized Adjustable Clamps, Providing necessary Connections including Taking down/ out unserviceable Drain Pipe, complete all as specified and as directed.
M&L Push Cock 15mm bore (dia) Brass Chromium plated, high pressure, screwed down for Socket/ Unions or GI Pipe including Taking down/ out unserviceable Push Cock, complete all as specified and as directed. MAKE : JAINSON/ NIXON or equivalent as approved by GE
M&L PVC Float Valve Assembly 15mm bore (dia) comprising Valve Assembly, Aluminum Rod, PVC Ball, suitable Water Cooler/ Desert Cooler including Taking down/ out unserviceable Float Valve Assembly, complete all as specified and as directed.
M&L PVC insulated, Sheathed Copper Conductor multi-stranded Cable of size 40/.0076, 3 Core (Colour White or Black) and Providing Electric Connection including Taking down/out unserviceable Cable of any description, complete all as specified and as directed.
EARTH WORKS
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Cable, Electric Post, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth exc. 1.50 Metre but not exc. 3.00 Mete for Electric Post, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Cable Line with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed.
Removal Excavated Materials (Soil) to a distance not exc. 50 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point, complete all as specified and as directed.
REPAIRS TO LT EXTERNAL ELECTRIFICATIONS
Dismantling unserviceable Steel Tubular Pole of any description and any size including Demolition Cement Concrete (if required on Ground) and Made Good disturbed Ground, complete all as specified and as directed. NOTE : Unserviceable Pole will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earthwork, Demolition Cement Concrete, etc. will not be Measured and Paid separately.
Dismantling Cross Arms, Mild Steel Channel, Angle Section, Flat Iron, Mild Steel Rod, etc., complete all as specified and as directed.
Taking down ACSR Conductor including Line Spacers of OH Electric Lines from LT Electric Poles of any size and capacity, complete all as specified and as directed.
Dismantling LT Stay Assembly complete of any description, complete all as specified and as directed.
Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from Trenches, Floors, Walls, GI Pipes, etc., complete all as specified and as directed. NOTE : Necessary Earth Work will be Measured and Paid under appropriate Items.
M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Copping of Electric Poles, etc. including weathering slightly rounded or chamfered angle and throating, finishing all exposed faces of Concrete with necessary Formwork, complete all as specified and as directed.
M&L Steel Tubular Swaged Pole Type 410 SP-31 (9.0 Metre long) complete with Mild Steel Base Plate, Finial Taper Plug, Bolts, Nuts & Screws, etc. as specified including One coat Aluminium Paint over One Coat of Red Oxide Zinc Chrome Primer, providing 3 No. Band/ Strap with Paint Black/ Yellow Colour 300mm apart from Plinth Block and numbering of Pole/ Painting embedded portion of Pole with One coat of Bituminous Paint, complete all as specified and as directed. NOTE : Necessary Earth Work & PCC will be Measured and Paid separately under relevent Items.
M&L Cross Arms, Bracings, Supports, Clamps and Back Plates, fabricated from Structural Steel Sections including Nuts, Bolts, Washers, etc., welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated or directed and applying Two coats of Aluminium Paint over a coat of Red Oxide Zinc Chromium Primer after preparation of Surfaces, complete all as specified and as directed.
S&F Pin type Insulator 100mm height, 65mm dia for 1100 Volt grade, Porcelain, Vitreous, white, brown or green including One Galvanised Mild Steel Spindle Two Galvanised Iron Washer and One Galvanised Iron Nut including Taking down unserviceable Insulator from Electric Pole, complete all as specified and as directed.
S&F Insulator Shackle type, Porcelain, Vitreious, white brown or green of size 150mm High and 150mm dia including Galvanised Mild Steel Straps of Section 38x5mm, 20mm dia Insulator Bolts, Nuts, Washer, etc. for Working Pressure 11000 Volt including Taking down unserviceable Insulator from Electric Pole, complete all as specified and as directed.
S&F Insulator Loop type, Small in size, Vitreous Porcelain, white, borwn or green with Overall Dimensions 65x90mm, Clearance of Hole 16mm including Taking down unserviceable Insulator from Electric Pole, complete all as specified and as directed.
S&F ACSR Conductor of any size for LT Over Head Line including Stringing Conductor fixed on Poles and binding with Aluminium Binding Wire, etc., complete all as specified and as directed. NOTE : Size of Conductor will be as per Site requirement as directed by Engineer-in-Charge.
M&L Restretching, Tightening & Fixing of ACSR Conductor of any size on LT Electric Poles including necessary Aluminium Binding Wire including Refixing of Connectors, PVC Sleeves for Jumper, etc. complete all as specified and as directed.
S&F PVC Fibre Separator for LT Line 1100 Volt Over Head Conductor 2/3/4-Wire System for Horizontal Spacing of Conductor complete with Nut and Bolts minimum 2 No. to prevent the Lines Touching Each Other on Heavy Winds as a Preventive Arrangement to the Existing System, complete all as specified and as directed.
M&L Trimming/Cutting of Tree Branches of any girth/size and Clearing of OH Lines (any Nos. of ACSR Conductors, Earth Wire, etc.) upto 3.0 Metre distance, Removing Tree Branches from the Sites, complete all as specified and as directed.
M&L Painting LT Electric Pole including Cross Arms, Channel, Flat Iron Clamps, etc. with One coat of Aluminium Paints and Numbering of Code in letter size not less then 50mm in Black Paints and Painting of Pole with the Strips 300mm high around the Pole with Two different Colours Synthetic Enamelled Paint for Pole 7.5 Metre height above Ground Level, complete all as specified and as directed.
M&L Stay Assembly complete with all Accessories such as Mild Steel Galvanised Flat Iron Stay Clamp 7/3.15 Mild Steel Galvanised Stay Wire, One Insulator Loop type Porcelain Vitreous (white, brown or green) Overall Dimensions 65x90mm and Clearance of Hole 16mm, Stay Grips, Mild Steel Galvanised Stay Bow, Thimbles, 16mm dia Mild Steel Galvanised Stay Rod and Mild Steel Galvanised Stay Plate all as shown in Electrical Plate No. 1 of MES Schedule Part-I, complete all as specified and as directed. NOTE : Earth Work, Cement Concrete, etc. will be Measured and Paid separately under relevant Items.
S&F Danger Notice Plate of size 20x15 Cm for LT, made of 1.6mm thick Mild Steel Sheet, Vitreous Enamelled White, Letters, Figures and Conventional Skull & Bones in Signal Red Colour and fixed with Mild Steel Clamps, Bolts & Nuts of appoved size including Taking down unserviceable Danger Notice Plate, complete all as specified and as directed.
S&F LED Street Light Fitting 25 Watt, New Generation, Energy Saving, Environmental Friendly, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.
S&F LED Street Light Fitting 40 Watt, New Generation, Environmental Friendly, Energy Saving, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.
Supplying, Laying, Commissioning & Testing LT Under Ground Cable 1100 Volt grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded Aluminium Conductor all as per IS:7098 (Part-I)-1998 having Cross-sectional Area 10 Sqmm, 2 Core, laid in Trenches, Ducts, Pipes or on Poles, etc., complete all as specified and as directed. NOTE : Earth Works, Pipes, Concrete Cable Cover, etc. will be Measured and Paid separately under relevent Items.
Supplying, Laying, Commissioning & Testing LT Under Ground Cable 1100 Volt grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded Aluminium Conductor all as per IS:7098 (Part-I)-1998 having Cross-sectional Area 16 Sqmm, 4 Core, laid in Trenches, Ducts, Pipes or on Poles, etc., complete all as specified and as directed. NOTE : Earth Works, Pipes, Concrete Cable Cover, etc. will be Measured and Paid separately under relevent Items.
Supplying, Laying, Commissioning & Testing LT Under Ground Cable 1100 Volt grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded Aluminium Conductor all as per IS:7098 (Part-I)-1998 having Cross-sectional Area 25 Sqmm, 4 Core, laid in Trenches, Ducts, Pipes or on Poles, etc., complete all as specified and as directed. NOTE : Earth Works, Pipes, Concrete Cable Cover, etc. will be Measured and Paid separately under relevent Items.
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
Supply & Laying Sub-class ‘B’ Bricks, Kiln burnt for Cable Protection Cover, complete all as specified and as directed.
S&F Air Breaks Gang Operating Switch 11 KV, Triple Pole with DO Mechanically Vertical Operated, mounted on Insulator and Steel Frame with operating mechanism worked from Ground Level for current rating up to 200 Amp including Taking down unserviceable GOD, complete all as specified and as directed.
S&F Change Over Switch (Side Handle) in Sheet Enclosure, ON LOAD, 415 Volt, 100 Amp rating 4 Pole, conforming to IS:13947 (Part I & II) and connecting up including Taking down/out unserviceable Change Over Switch, complete all as specified and as directed.
S&F HBC Fuse Link Bolted type, Central Tag type C-2 TTS, 415 Volt, 80 kA, Rating 400 Amp and fixing on existing Panel Board and connecting up including Taking down/out unserviceable Fuse Link, complete all as specified and as directed. MAKE : HAVELLS, Cat No. IHHTTSO400
S&F MCCB 100 Amp 4 Pole, 25 kA, 415 Volt, 50 Hz with Outgoing & Incoming Cable Connection and connecting up including Taking down/out unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 125 Amp 4 Pole, 36 kA, 415 Volt, 50 Hz with Outgoing & Incoming Cable Connection and connecting up including Taking down/out unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 200 Amp 4 Pole, 36 kA, 415 Volt, 50 Hz with Outgoing & Incoming Cable Connection and connecting up including Taking down/out unserviceable MCCB, complete all as specified and as directed.
S&F LT Insulation Rubber Mat 10mm thick of size 2.0x1.0 Metre, ISI marked, and laid on Floor including Taking down/out unserviceable Rubber Mat, complete all as specified and as directed.
M&L Cleaning, Scraping of Exposed Surfaces of LT Panel/ Feeder Pillar /Pole Box, Indoor/ Outdoor Type and applying One coat of Synthetic Enamel Paint (Paint & Shade as approved) with Spray Painting Machine including Writing MES No. and Machine No. with Black Paint, Letters 50mm High and 15mm Wide, complete all as specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Earth Works in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4(20mm graded stone aggregate) reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Earth Works in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
REPAIRS/MAINT TO DG SETS
M&L Repairs/Maint & Servicing of DG Set 30 KVA capacity of MAKE : ASHOK LAYLAND, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings. (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE :- (a) Cost of all Materials i.e. Spare Parts and Labour Elements required for Functional of DG Set will deem to be included in the Quoted Unit Rate. (b) Quantites of Spare Parts at Item No. 9.02 to 9.10 are Proisional and will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Fuel Filer Assembly (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Oil Filer Assembly (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only V Belt (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
M&L Repairs/Maint & Servicing of DG Set 62.5 KVA capacity of MAKE : ASHOK LAYLAND, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings. (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE :- (a) Cost of all Materials i.e. Spare Parts and Labour Elements required for Functional of DG Set will deem to be included in the Quoted Unit Rate. (b) Quantites of Spare Parts at Item No. 9.11 to 9.18 are Proisional and will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Controler Model No. KG162 SWS (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Fuel Filer Assembly (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Oil Filer Assembly (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only V Belt (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
M&L Repairing & Cleaning of Diesel Tank of any Capacity with suitable Materials after disconnecting Fuel Line, Opening of all Nuts, Bolts, etc., Re-fixing the Same after Satisfactory Repairing including necessary Welding (if required), etc., complete all as specified and as directed.
S&F Toggle Switch 3-way, Double Pole (as per existing/ as approved) and connected including Taking down/out unserviceable Toggle Switch, complete all as specified and as directed.
Supply & Filling Coolant for Radiators as approved), complete all as specified and as directed. MAKE : KIRLOSKAR
Supply & Filling Engine Oil 20 W/ 40 Grade as approved), complete all as specified and as directed. MAKE : CASTROL CRB Plus
REPAIRS/MAINT OF EXTERNAL WATER SUPPLY
Taking up Galvanised Steel Tubing 25mm bore (dia) with Connections of any description, complete all as specified and as directed.
Taking up Galvanised Steel Tubing 32mm bore (dia) with Connections of any description, complete all as specified and as directed.
Taking up Galvanised Steel Tubing 50mm bore (dia) with Connections of any description, complete all as specified and as directed.
Taking up Galvanised Steel Tubing 80mm bore (dia) with Connections of any description, complete all as specified and as directed.
Taking up Galvanised Steel Tubing 100mm bore (dia) with Connections of any description, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 25mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 32mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 50mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 63mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 90mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
S&F Gate Valve 25mm bore (dia) in size for PP-R Pipe including Taking down/out Unserviceable Valve of any description, complete all as specified and as directed.
S&F Gate Valve 32mm bore (dia) in size for PP-R Pipe including Taking down/out Unserviceable Valve of any description, complete all as specified and as directed.
S&F Gate Valve 40mm bore (dia) in size for PP-R Pipe including Taking down/out Unserviceable Valve of any description, complete all as specified and as directed.
S&F Gate Valve 50mm bore (dia) in size for PP-R Pipe including Taking down/out Unserviceable Valve of any description, complete all as specified and as directed.
M&L Cast Iron Sluice Valve 80mm bore (dia), Operation-cap, both sides Flanged, ISI Marked (IS:14846-2000 & Class PN 1.6) having Cast Iron Hand Wheel, Brass Spindle, Cheek Nuts and Sliding Gate and Body with Mild Steel Bolts & Nuts and Testing against Leakage including Taking out/ down Old Unserviceable Sluice Valve, complete all as specified and as directed.
M&L Cast Iron Sluice Valve 100mm bore (dia), Operation-cap, both sides Flanged, ISI Marked (IS:14846-2000 & Class PN 1.6) having Cast Iron Hand Wheel, Brass Spindle, Cheek Nuts and Sliding Gate and Body with Mild Steel Bolts & Nuts and Testing against Leakage including Taking out/ down Old Unserviceable Sluice Valve, complete all as specified and as directed.
M&L Construction Brick Masonry Valve Chamber of Size 60x60x60 Cm (Internal Dimension of Chamber) with Cement Concrete 1:4:8 (40mm graded stone aggregate) 100mm thick in Foundation, One Brick thick Brick Walls in Cement Mortar 1:4, Rendering 15mm thick on Brick Walls in Cement Mortar 1:4 and all Internal Surfaces except PCC Foundation Bed, Externally upto 150mm below Normal Ground Level, providing Mild Steel Valve Chamber Cover 2.0mm thick with Hinges, Handle and Locking Arrangements with Mild Steel Angle Iron Frame 40x40x5.0mm on Top of Valve Pit, Angle Iron Frame embedded in Cement Concrete 1:2:4 (20mm graded stone aggregate) 100mm thick including applying Two Coats of Black Synthetic Enamel Paint over a coat of Red Oxide Zinc Chrome Primer after necessary preparation to all Steel Surfaces Painting, all necessary Earth Work i.e. Excavation in any type of Soil, Returning, Filling in and Removal of Surplus Soil to a distance not exc. 50.00 Metre including Demolition of Damaged Valve Chamber, complete all as specified and as directed.
M&L Construction Brick Masonry Valve Chamber of Size 100x100x100 Cm (Internal Dimension of Chamber) with Cement Concrete 1:4:8 (40mm graded stone aggregate) 100mm thick in Foundation, One Brick thick Brick Walls in Cement Mortar 1:4, Rendering 15mm thick on Brick Walls in Cement Mortar 1:4 and all Internal Surfaces except PCC Foundation Bed, Externally upto 150mm below Normal Ground Level, providing Mild Steel Valve Chamber Cover 2.0mm thick with Hinges, Handle and Locking Arrangements with Mild Steel Angle Iron Frame 40x40x5.0mm on Top of Valve Pit, Angle Iron Frame embedded in Cement Concrete 1:2:4 (20mm graded stone aggregate) 100mm thick including applying Two Coats of Black Synthetic Enamel Paint over a coat of Red Oxide Zinc Chrome Primer after necessary preparation to all Steel Surfaces Painting, all necessary Earth Work i.e. Excavation in any type of Soil, Returning, Filling in and Removal of Surplus Soil to a distance not exc. 50.00 Metre including Demolition of Damaged Valve Chamber, complete all as specified and as directed.
M&L Cleaning Existing Water Sump 42000 LITRE capacity by carry out the following Works, complete all as specified and as directed :- (a) Dewatering the Sump by employing Tulu Pump and Man Power. (b) Removing the Sludge, Muddy and dissolved Iron Water from the Sump by employing Man Power and required Tools & Plants. (c) Scrubbing the Algae from Walls, Corners, etc. completely by using Wire Brush and Man Power. (d) Washing Walls, Bottom, Conrners, etc. using Bleaching Powder. NOTE : Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Sump will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account.
M&L Cleaning Existing Water Sump 80000 LITRE capacity by carry out the following Works, complete all as specified and as directed :- (a) Dewatering the Sump by employing Tulu Pump and Man Power. (b) Removing the Sludge, Muddy and dissolved Iron Water from the Sump by employing Man Power and required Tools & Plants. (c) Scrubbing the Algae from Walls, Corners, etc. completely by using Wire Brush and Man Power. (d) Washing Walls, Bottom, Conrners, etc. using Bleaching Powder. NOTE : Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Sump will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account.
REPAIRS/MAINT OF PUMPS & MOTORS
M&L Repairs Monoblock Pump 3.0 HP capacity, complete all specified and as directed involving the following Works :- (a) Disconnecting all Electric & Water Supply Connections, Removing to AGE E/M Store Yard at NLP, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning Covers and Parts as required. (b) Transporting defective Pump to nearest Workshop for Repairing and carry out Repair works including Replacement of defective Unserviceable Parts. (c) Reassembling the Pump after repaired. (d) Transporting the repaired Pump to Work Site and Installation of the same, Carry out necessary Tests in presence of JE/Engineer-in-Charge to the entire satisfaction. (e) Painting Installed Pump Externally with applying Two Coats of Synthetic Enamel Paint (Shade of Paint as approved/ordered). NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as "Supply only" under relevant Items. Cost of Labour Element involved for replacement of Parts will deem to included in the Quoted Unit Rate. (b) Any Minor repairs involved to make the Pump Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department. (c) Greasing/Oiling, etc. of Parts as as required shall be done by the Contractor without any Extra Cost to the Department. (d) Rewinding of Stator of Motor of Monoblock Pump, where invloves will be Measured and Paid separately under relevant Items.
Supply only Ball Bearing (SKF 6306) suitable for Monoblock Pump 3.0 HP capacity, complete all as specified and as directed.
Supply only Cast Iron Impaller CI KDS-3 suitable for Monoblock Pump 3.0 HP capacity, complete all as specified and as directed.
M&L Taking out burnt Copper Windings from Motor of Monoblock Pump 3.0 HP capacity, Cleaning Slots of Motor, Rewinding the same with Super Enamalled Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the Same and Testing after Rewinding, complete all as specified and as directed.
M&L Repairs Monoblock Pump 5.0 HP capacity, complete all specified and as directed involving the following Works :- (a) Disconnecting all Electric & Water Supply Connections, Removing to AGE E/M Store Yard, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning Covers and Parts as required. (b) Transporting defective Pump to nearest Workshop for Repairing and carry out Repair works including Replacement of defective Unserviceable Parts. (c) Reassembling the Pump after repaired. (d) Transporting the repaired Pump to Work Site and Installation of the same, Carry out necessary Tests in presence of JE/Engineer-in-Charge to the entire satisfaction. (e) Painting Installed Pump Externally with applying Two Coats of Synthetic Enamel Paint (Shade of Paint as approved/ordered). NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as "Supply only" under relevant Items. Cost of Labour Element involved for replacement of Parts will deem to included in the Quoted Unit Rate. (b) Any Minor repairs involved to make the Pump Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department. (c) Greasing/Oiling, etc. of Parts as as required shall be done by the Contractor without any Extra Cost to the Department. (d) Rewinding of Stator of Motor of Monoblock Pump, where invloves will be Measured and Paid separately under relevant Items.
Supply only Ball Bearing (SKF 6306) suitable for Monoblock Pump 5.0 HP capacity, complete all as specified and as directed.
Supply only Cast Iron Impaller CI KDS-3 suitable for Monoblock Pump 5.0 HP capacity, complete all as specified and as directed.
M&L Taking out burnt Copper Windings from Motor of Monoblock Pump 5.0 HP capacity, Cleaning Slots of Motor, Rewinding the same with Super Enamalled Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the Same and Testing after Rewinding, complete all as specified and as directed.
M&L Repairs Monoblock Pump 10 HP capacity, complete all specified and as directed involving the following Works :- (a) Disconnecting all Electric & Water Supply Connections, Removing to AGE E/M Store Yard, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning Covers and Parts as required. (b) Transporting defective Pump to nearest Workshop for Repairing and carry out Repair works including Replacement of defective Unserviceable Parts. (c) Reassembling the Pump after repaired. (d) Transporting the repaired Pump to Work Site and Installation of the same, Carry out necessary Tests in presence of JE/Engineer-in-Charge to the entire satisfaction. (e) Painting Installed Pump Externally with applying Two Coats of Synthetic Enamel Paint (Shade of Paint as approved/ordered). NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as "Supply only" under relevant Items. Cost of Labour Element involved for replacement of Parts will deem to included in the Quoted Unit Rate. (b) Any Minor repairs involved to make the Pump Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department. (c) Greasing/Oiling, etc. of Parts as as required shall be done by the Contractor without any Extra Cost to the Department. (d) Rewinding of Stator of Motor of Monoblock Pump, where invloves will be Measured and Paid separately under relevant Items.
Supply only Ball Bearing (SKF 6306) suitable for Monoblock Pump 10 HP capacity, complete all as specified and as directed.
Supply only Cast Iron Impaller CI KDS-3 suitable for Monoblock Pump 10 HP capacity, complete all as specified and as directed.
M&L Taking out burnt Copper Windings from Motor of Monoblock Pump 10 HP capacity, Cleaning Slots of Motor, Rewinding the same with Super Enamalled Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the Same and Testing after Rewinding, complete all as specified and as directed.
M&L Lifting of Submersible Pump & Motor Assembly 12.5 HP capacity alongwith complete Column Pipes, Submersible Cable, Safety Rope, etc. from the existing Borewell by employing Chain Pulley Block, etc., Dismantling Column Pipes by Opening Nuts, Bolts, Pump & Motor, etc, Seggregating & Stacking of Serviceable Column Pipes & Other Materials and Keep in Safe Custody for re-use, complete all as specified and as directed.
M&L Removing Submersible Pump & Motor Assembly 12.5 HP capacity to AGE E/M Store Yard at NLP, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning of Cover and Parts as required, Transporting defective Submersible Pump & Motor Assembly to nearest Workshop for Repairs, Repairing & Replacing of Unserviceable Parts, Reassembling Submersible Pump Motor Assembly after repaired, Transporting repaired Submersible Pump Motor Assembly back to Work Site, complete all as specified and as directed. NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as "Supply only" under relevant Items. Cost of Labour Element involved for replacement of Parts will deem to included in the Quoted Unit Rate. (b) Any Minor repairs involved to make the Submersible Pump & Motor Assembly Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department. (c) The Cost of Minor Spares Parts/Items viz Nuts, Bolts, Washers, Gasket, etc. will deem to be include in the Quoted Unit Rate. (d) Rewinding of Submersible Motor, wherever invloves will be Measured and Paid separately under relevant Item.
M&L Dismantling Submersible Motor 12.5 HP capacity, Taking out burnt Windings, Cleaning of Slots of the Motor and Rewinding the same with Super Enamalled Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the Same and Testing for Smooth Functioning after Rewinding, complete all as specified and as directed.
Supply only Bush for Impeller, 'C' type, Part No. 1091 (as per existing/ as approved) suitable for Submersible Pump 12.5 HP capacity, complete all as specified and as directed.
Supply only Gun Metal Bush for Intermediate Part No. 933.1 (as per existing/ as approved) suitable for Submersible Pump 12.5 HP capacity, complete all as specified and as directed.
Supply only Gun Metal Bush (Upper Part No. 1175, Lower Part No. 1176) (as per existing/ as approved) suitable for Submersible Motor 12.5 HP capacity, complete all as specified and as directed.
Supply only Gun Metal Impeller Part No. 151 complete (as per existing/ as approved) suitable for Submersible Pump 12.5 HP capacity, complete all as specified and as directed.
Supply only Stainless Steel Sleeve for Impeller Part No. 2004 (as per existing/ as approved) suitable for Submersible Pump 12.5 HP capacity, complete all as specified and as directed.
Supply only Stainless Steel Shaft of Standard size complete Part No. 180 (as per existing/ as approved) suitable for Submersible Pump 12.5 HP capacity, complete all as specified and as directed.
Supply only Thurst Bearing for Part No. 1225 (as per existing/ as approved) suitable for Submersible Motor 12.5 HP capacity, complete all as specified and as directed.
M&L Lowering down Submersible Pump & Motor Assembly 12.5 HP capacity (after Repaired & Testing of Functionability) alongwith Column Pipes of any Size and Length, Submersible Cable, Steel Wire Rope, etc. with the help of Chain Pulley Block and Tool & Plants, Testing on Completion, complete all as specified and as directed. NOTE : Serviceable Materials viz Column Pipes, etc. will be keep in Safe Custody for Lowering . Rusted/ Unserviceable Column Pipes shall be replaced with New Pipes and the same will be Measured & Paid as 'Supply only' under approprite Item.
M&L Direct Online Starter suitable for 3.0 HP Motor (as per existing as approved), fixing to Existing Panel Board with necessary Fixing Arrangements and providing all Electric Connections including Taking down/out Unserviceable Starter from Panel Board, complete all as specified and as directed. MAKE : HAVELLS Cat No. IHPDOLJA*D
M&L Direct Online Starter suitable for 5.0 HP Motor (as per existing as approved), fixing to Existing Panel Board with necessary Fixing Arrangements and providing all Electric Connections including Taking down/out Unserviceable Starter from Panel Board, complete all as specified and as directed. MAKE : HAVELLS Cat No. IHPDOLJA*E
M&L Direct Online Starter suitable for 10 HP Motor (as per existing as approved), fixing to Existing Panel Board with necessary Fixing Arrangements and providing all Electric Connections including Taking down/out Unserviceable Starter from Panel Board, complete all as specified and as directed. MAKE : HAVELLS Cat No. IHPDOLJA*G
M&L Deluxe Automatic Star Delta Starter suitable for 12.5 HP Motor (as per existing as approved), fixing to Existing Panel Board with necessary Fixing Arrangements and providing all Electric Connections including Taking down/out Unserviceable Star Delta Starter from Panel Board, complete all as specified and as directed. MAKE : HAVELLS Cat No. IHPASDMB*
M/s GANDHESWAR PHUKAN
NChetia and Sons Trading
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .