| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹92.7 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹1.1 Cr+₹13.0 L (14.0%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹1.1 Cr+₹13.6 L (14.7%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹1.1 Cr+₹14.4 L (15.5%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹1.1 Cr+₹14.7 L (15.8%)Rejected-Finance 245A 7A 1 JAYANTIPUR GOKUL AVAS YOJANA SULEM SARAI ALLAHABAD PRAYAGRAJ | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211011 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
18 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) BAMRAULI
HQ CWE (AF) BAMRAULI Allahabad 211012
AUGMENTATION OF ELECTRICAL POWER SUPPLY FOR COMMUNICATION UNIT AT BAMRAULI
2019_MES_307332_3
87017/C/E8
Open Tender
Civil Works
Lump-sum
270 days
Bamrauli Alahabad
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE (AF) Bamrauli
₹1.9 L
Yes
21 Sept 2020
4 Jul 2020
21 Jul 2020
4 Jul 2020
18 Jul 2020
11 Jul 2020
60 days
Amount
Lump Sum price worked out by the contractor for 'Building work' as inserted by the MES in Schedule ‘A’ Part I.
Lump Sum price worked out by the contractor for 'Internal Electric Supply' as inserted by the MES in Schedule ‘A’ Part II.
Lump Sum price worked out by the contractor for 'Path' as inserted by the MES in Schedule ‘A’ Part III.
Lump sum price worked out by the Contractor for “External Electric Supply” as inserted by the MES in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for "Earth Work" as inserted by the MES in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for Schedule `A' Part-VI (rate against Srl No. 6.01 to 6.21 shall be quoted by the Contractor)
Supply, installation, testing and commissioning of step down transformer of capacity 500 KVA, indoor type complete with standard fitting and accessories, HT 11KV, 3 Phase, LT 433 volt, 3 phase 4 wire with off load tap changer on primary side to carry secondary voltage ± 7½ % with tappings at every 2½ % all as per IS 1180-2014 level 1, copper wound, oil cooling with fins vector group : DYN 11, including initial oil fitting complete all as specified including the following accessories :- (a) Three numbers porcelain bushing HT, 11KV with brass bushing rods, nuts, bolts and washers etc inside cable end box. (b) One cable box LT side consisting of 4 Nos porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 core LT under ground cable. (c) Oil conservator with filler type drain valve and oil level gauge. (d) Dheydrating breather with fast fill of dehydrating agent. (e) Explosion vents (f) Thermometer pocket on tank cover. (g) One number 100mm dia, dial type thermometer vapour pressure type having range 0 to 120 degree centigrade. (h) Rating plate and terminal marking plate. (j) Earthing arrangement. (k) Oil drain filter valve. (l) Oil drain valve. (m) Lifting hook. (n) Oil conservator with filling hole and cap. (o) Air relief valve plug. (p) Four plate solid cast steel detachable rollers. (q) Earth bushing for neutral outside the cable box for providing independent earthing for neutral. (r) Suitable size of channel on foundation for fixing the transformer with joint and stopper.
Material and labour for earthing complete with copper earth plate electrode 600mm x 600mm x 3.15mm thick buried directly in ground vertically to depth not less than 3.0 metre below normal ground level (with top edge of earth plate not less than 2.70 metre below ground level), connected to copper strip 20mm x 3mm main earthing lead by means of galvanized bolts, nuts and washers with connected to earth test point to main switch board panel etc. all as specified and testing on completion with and including necessary excavation and earth work, in any type of soil, adequate quantity of charcoal dust and common salt, test point, earth pit covered with precast (RCC 1:2:4) type B1 (using 20mm graded stone aggregat) 40 mm thiick cover, reinforced with 8mm dia TMT bar 3 Nos. dia both way with 12mm round bar handle. GI medium grade watering pipe 20mm dia with funnel, wire mesh all as shown in electric plate No. 3 of MES SSR Part-I and 40mm dia GI medium grade pipe for earth lead protection complete all as specified and directed. Note :- (i) The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth and GI pipe for protection of earth strip. Any varriation in quantity shall be adjusted. (iv) Surplus soil shall be removed upto 50 metre.
Material and labour Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5metre below the ground level connected to GI strip 32x6 mm by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 40 mm bore medium grade for protection of earth strip, PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways, CI frame and charcoal dust and common salt, all as shown in electrical plate No. 3 of MES SSR part-I and making test point as specified including excavation & earth work in any type of soil and connecting the earthing to an earthing point/equipment as specified and directed & testing on completion. NOTES : (i) The concrete pit shall be made in PCC 1:3:6 type C-1, using 20mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be adjusted through deviation order (iii) Items includes cost of 7.5 metre earth lead strip. Any variation in length shall be adjusted through deviation order. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides
Cable jointing kit for 11 KV (earthed) heat shrinkable, indoor type end termination joint suitable for cross sectional area 120 Sqmm, 3 core aluminium conductor XLPE Cable including jointing material and accessories complete.
Supply, fixing, connecting and testing APFC Panel with MD-XL Capacitor and MCCB as incomer (Auto / Manual option) with 200 (2x12.5+1x25+3x50) KVAR capacity. Make :- APFC Panel shall be CAT PART NO QHKTEB5200X0 of HAVELLS or equivalent model of make specified in appendix 'B' to particular specifications.
Supply and fix and connecting LED street light fitting including lamp 70 Watt long life veratile pressure dia cast aluminium housing, head resistant glass, IP-66 protection, potted / incapsuated driver surge protection upto 4KV, better optics for uniform distribution complete and connecting the fitting electrically to the system using 2.5 sqmm three core PVC insulated weather proof multistranded copper conductor cable with suitable thimble / lugs to the pole box through inside the pole including provision of single arm bracket made of 40 mm dia light grade GI pipe (1.2 metre long) bending to angle of 120 degree and mild steel flat iron 32 x 6 mm clamps of suitable size two numbers including nut, bolt and washers fixed on wall/pole complete. Make :- Philips Cat No BRP409LED074CW HE MR FG S1 PSU GR or equivalent model of make mentioned in Appendix 'B' to particular specifications.
Supply only ceiling fans 1200 mm sweep white in colour of Aluminium blades(three numbers) and body,double ball bearing, down rod, .fan motor, pair of canopy, shackle, assembly kit etc suitable for SP 230 to 250 volts, 50 Hz, AC supply complete. Make :- Havells CAT No ES-50 5 star (energy saving fan) or equivalent model of make specified in appendix 'B' to particular specifications.
Supply only exhaust fan 450 mm sweep, heavy duty, four blade, double ball beaming, 1400 RPM minimum air delivery discharge 6120 CMH suitable for SP, 230/250 volts, 50Hz, AC supply with louver shulter complete in existing opening and connecting with and including 3 ram 1.5 sqmm single core, PVC insulated but unsheathed FRLS multistranded copper conductor cable from ceiling rose to fan.
Supply, fixing in replacement and connecting wall mounted LED light fitting 1 x 20 Watt LED (6000K/6500K) (1200/1144mm) extruded aluminium heat sink provided for efficeint heat dissipation intergrated electronic driver including necessary electric connection complete all as specified and directed.. Note :- Fitting shall be of Make Philips cat part No BN021C LED20S PSU CW GR S2, Havells cat part No LUMILINEBS20WLED840SPCWH or equivalent model of make specified in Appendix 'B' to particular specifications.
Horizontal boring of holes under road by trenches less technology using ultra sound technology with machine for laying 100 mm bore HDPE pipe without disturbing the road surface. Note :- (i) Boring shall be done upto 1.00 metre below the top surface of road / pavement / hard standing etc. (ii) Quoted rate deem to be included cost of HDPE Pipe 100 mm bore suitable for 0.4 mpa working pressure.
Cable route indicators consisting of CI disc, round 150 mm dia, 6 mm thick duly embossed with lettering "MES HT Cable" and fixed with mild steel angle iron of size 35x35x5 mm, 600 mm long with bolts & nuts embeded in ground in route of cable including PCC block of size 300x300x300 mm type C-1 using 20mm graded stone aggregate.
Cable route indicators consisting of CI disc, round 150 mm dia, 6 mm thick duly embossed with lettering "MES LT Cable" and fixed with mild steel angle iron of size 35x35x5 mm , 600 mm long with bolts & nuts embeded in ground in route of cable including PCC block of size 300x300x300 mm type C-1 using 20mm graded stone aggregate.
MCBs, 'C' series, SP, 6 Amps to 32 Amps, 230/240 Volts, 10 KA breaking capacity,IS-8828 marked and rating and fixing in DBs (DBs catered separately in schedule 'A' Part III).- Note: Make of the MCB should be the same as that of DB, catared under schedule 'A' Part III
MCB, single pole and neutral, 415 volts, 40 Amps rating, 10KA, "C" series fixed in DBs (DBs catered separately in schedule 'A' Part III). Note : Make of the MCB should be the same as that of DB, catared under schedule 'A' Part III
DEORA ELECTRIC WORKS
M/s NSA Engineering Corporation
Titco Electricals
R.K.ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .