Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹19.0 L+₹2.6 L (16.1%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹19.1 L+₹2.7 L (16.7%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹19.3 L+₹2.9 L (17.9%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹19.3 L+₹3.0 L (18.2%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
25 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineer North Nagar-Pathardi Road Opp Ahmednagar Fort Ahmednagar-414002
Provision of guard room and certain otehr sanctioned works in the area of AGE B/R I under GE (N) Ahmednagar
2020_MES_404102_2
8475 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class E a (i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹39,000
Yes
5 Feb 2021
5 Jan 2021
27 Jan 2021
5 Jan 2021
25 Jan 2021
19 Jan 2021
60 days
Amount
Excavation in trenches not exc 1.5 m wide and n exc 1.5m deep as in foundation and getting out in hard dense soil etc complete all as specified and directed by Engineer-in-Charge
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC (1:4:8) type D2 using (40mm graded stone aggregate) as in foundations, fillings & mass concrete etc complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm with soils etc complete all as specified and directed by Engineer-in-Charge
Removing excavated surplus soil n.exc 50m deposiitng where directed at a level not exec 1.5m above the starting point etc complete all as specified and directed by Engineer-in-Charge
M&L for form work to sides of concrete foundations, footings, bases of columns rafts and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work on fair finished surfaces etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC M-25 design mix using 20mm graded stone aggregate for foundations, including rafts, footings, foundation beams, plinth beams; bases for columns etc basement slabs, under reamed piles and mass concrete etc complete all as specified and directed by Engineer-in-Charge
M&L for form work to sides of pillars, posts, struts, piers, columns and stanchions on fair finished surfaces etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC M-25 design mix using 20mm graded stone aggregate for columns, pillars, piers, posts and struts etc complete all as specified and directed by Engineer-in-Charge
M&L for form work to sides and soffits of beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves etc on fair finished surface etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC M-25 design mix using 20mm graded stone aggregate for beams, canilevers, bressumers, lintels over 1.5m span etc complete all as specified and directed by Engineer-in-Charge
M&L Form work soffits of suspended slab such as roof slabs, floor slabs landings and similar work not exceeding 200mm thick horizontal or sloping in fair finished surfaces etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC M-25 design mix using 20mm graded stone aggregate for slabs supported on walls and columns in floors, roof, landings, balconies, canopies, deck slabs and in shelves etc complete all as specified and directed by Engineer-in-Charge
Material and labour for water proofing treatment over RCC slab by applying one coat of bituminous primer @ 0.25 Kg / Sqm and providing 3mm thick APP modified water proofing membrane weighting not less 3.5 Kg / Sqm, reinforced with non woven polyster reinforcement mat weighing not less than 160 gm / Sqm, polyster core having softening point not less than 150 degree C, longitudinal tensile strength not less than 650 N / 5 cm, tearing strength of 180 N / 5 cm including a coat of solar reflective aluminium paint @ 0.15 Kg / Sqm including cleaning the newly plastered surfaces of concrete / existing plastered vertical surfaces with with wire brushes free from dust etc complete all as specified and directed by Engineer-in-Charge
Material and labour for brick work with fly ash straight or curved on plan exc 6m mean radius built in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering 15mm thick plaster on walls in cement and sand mortar (1:6), on fair faces of brick work or concrete surfaces, finish the surfaces even & fair etc complete all as specified and directed by Engineer-in-Charge
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n. exc 15 cm thick spread, levelled and rammed including watering etc complete all as specified and directed by Engineer-in-Charge
M&L for Hardcore of guage n. exc 63mm, of broken stone or boulders deposited, spread and levelled in layers n.exc 15cm thcik, watered and rammed to a true surface etc complete all as specified and directed by Engineer-in-Charge
M&L for 100mm thick PCC (1:4:8) type D2 using (40mm graded stone aggregate) as in flooring, etc complete all as specified and directed by Engineer-in-Charge
M&L mild steel TMT bars 10 mm dia and over cut to length bent shape as required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S etc complete all as specified and directed by Engineer-in-Charge
All as per item No. 20 (here-in-before) but 8 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering 10mm thick in cement and sand mortar (1:4) on fair faces of brick work or concrete surfaces finished even and smooth with using sagol finish etc complete all as specified and directed by Engineer-in-Charge
M&L for applying two coats of Oil bound distemper on newly plastered surfaces of walls paint over 2mm thick wall care putty including preparation of surfaces etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of new plastered surface of ceiling and applying three coats of white wash on ceiling etc complete all as specified and directed by Engineer-in-Charge
M&L for applying two coats of cement base paint on newly / old plastered surfaces including preparationon wall etc complete all as specified and directed by Engineer-in-Charge
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces including preparation of surfaces etc complete all as specified and directed by Engineer-in-Charge
M&L for applying 3 coats of white wash on newly / old plastered surfaces incl preparation of surface of wall.etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC (1:2:4), type B1 (using 20 mm graded stone aggregate) 40 mm thick as in flooring, finished even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge
M&L for 75mm thick PCC (1:3:6), type C2 (using 40 mm graded stone aggregate ) 75 mm thick as in plinth protection etc complete all as specified and directed by Engineer-in-Charge
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm in floor over and including 15 mm thick screed bedding in cement and sand mortar (1:6), set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
M&L for glazed ceramic coloured tiles of size 350 x 250 x 7 mm thick on vertical surfaces such as dados over and including 10 mm thick backing coat in cement and sand mortar (1:4) set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick, area of tile exc 0.18 Sqm but not exc 0.38 Sqm in floor over and including 15 mm thick screed bedding in cement and sand mortar (1:6), set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
Material and labour in repairs for granite slab, 16 mm to 18 mm thick laid over and including 15 mm thick screed in cement and sand mortar (1:6), jointed and pointed with coloured cement to match on kitchen platform and shelves including grinding and polishing the exposed edges etc complete all as specified and directed by Engineer-in-Charge
M&L machine cut cudappa stone slab 20-25 mm thick over cement screed base, laid over and including 15 mm thick screed bed in cement and sand mortar (1:6), set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge
S&F in repairs 32 mm dia high density polythylene pipes (HDPE) of pressure rating 6 kg/cm2 fixed etc complete all as specified and directed and directed by Engineer-in-Charge
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing etc complete all as specified and directed by Engineer-in-Charge
S&F factory made solid PVC door shutter 30 mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails frame shall be covered with heat moulded plain coloured PVC `C' channel having a PVC sheet strip of 20 mm width stuck and plain colour PVC sheets for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, supplying and fixing in the frame etc complete all as specified and directed by Engineer-in-Charge
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and directed by Engineer-in-Charge NOTE: Wire cloth, glass, guard bars and painting shall be measured and paid separately.
S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter with lock rail and panel of 9 mm B.W.P. commercial plywood . The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated etc complete all as specified and directed by Engineer-in-Charge
S&F 100 mm long butt hinge, medium weight, cold rolled mild steel etc complete all as specified and directed by Engineer-in-Charge
S&F 200 mm long mild steel barrel tower bolt, stove enamelled black, with bright bolt etc complete all as specified and directed by Engineer-in-Charge
S&F 150 mm long mild steel pressed handles, oval type, stove enamelled black etc complete all as specified and directed by Engineer-in-Charge
S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate etc complete all as specified and directed by Engineer-in-Charge
S&F 200 mm long aluminium anodised barrel tower bolt, of extruded sections etc complete all as specified and directed by Engineer-in-Charge
S&F 150 mm long aluminium anodised handle, cast type etc complete all as specified and directed by Engineer-in-Charge
Supply and fix rotational moulded polyethylene water storage tanks double layer ISI marked conforming to IS 12701-1996 (cylindrical vertical with closed top) and made out of virgin FDA approved polyethylene material of 500 litres capacity hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting complete all as specified and directed.
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore fixed etc complete all as specified and directed by Engineer-in-Charge
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling etc complete all as specified and directed by Engineer-in-Charge
All as per item No 48 (here-in-before) but 20mm dia pipe.
S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls etc complete all as specified and directed by Engineer-in-Charge
S&F 75 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls etc complete all as specified and directed by Engineer-in-Charge
S&F 75 mm dia PVC (SWR) vent cowl etc complete all as specified and directed by Engineer-in-Charge
S&F 110 mm bore PVC (SWR) branch piece double (single Y) equal or unequal etc complete all as specified and directed by Engineer-in-Charge
S&F 110 mm dia PVC (SWR) bend any radius etc complete all as specified and directed by Engineer-in-Charge
S&F 75 mm dia PVC (SWR) bend with access door any radius etc complete all as specified and directed by Engineer-in-Charge
S&F in repair, Bib tap 15 mm dia, fancy type chromium plated, cast copper alloy with crutch or butter fly handle screwed down screwed for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge
M&L for 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed etc complete all as specified and directed by Engineer-in-Charge
S & F Stainless Steel kitchen plate rack made out of 0.63mm thick sheet of size (31"x36' x 10') with complete acessories etc complete all as specified and directed by Engineer-in-Charge
S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples fixed in repair etc complete all as specified and directed by Engineer-in-Charge
M&L for 2nd class hardwood plain fillites rectangular in section wrought secured with nails exc 6 and n'exc 13 sqcm etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC (1:2:4) type B1 using graded stone aggregate as in coping including necessary formwork, weatherig, slightly rounded or chamfered angle and throating etc complete all as specified and directed by Engineer-in-Charge
S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 etc complete all as specified and directed by Engineer-in-Charge
Supply only mild steel in flat, round or square bars in avilable length Fe.290.Gde-E-165 etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs vitreous China white squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest set in cement concrete including flush pipe and connecting to trap / flushing cistren complete all as specified and directed.Make :- Cat Part No C0117 Of Parryware or Cat Part No 20042 of Hindware or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fix PVC valveless, syphonic action type, flushing cistern,low level, all accesories all as directed. Make :- Sleek essence series Of Hindware or Cat part No E8303 Of Parryware or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fix in repairs wash hand basin vitreous China white, flat back type of size 550 X 400 mm pedastal type including pedastal, CP waste chain and plug and porcelain stopper, waste pipe, a pair of brackets,or errecting stand and PVC connection all as specified and directed. Make :- Cat Part No 10098 of Hindware or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fix in repairs wash hand basin vitreous China, flat back of size 550 X 400 mm including a pair of brackets, PTMT waste coupling, 32 mm dia PVC flexible waste pipe and connecting to stop valve and nahani trap etc complete all as specified and directed by Engineer-in-Charge. Make : Cat Part No 10004 of Hindware or Cat Part No C0475 of Parryware or equivalent in list of makes mentioned in list of makes in Appendix `C'
Supply and fix 15 mm bore pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe etc complete .Make:- (Cat part No MOR 1010(Orintal series) of MARC or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fixing in repairs stop valve cast copper alloy, fancy type screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fix of size 15 mm bore Make:- (Cat part No MOR 1320(Orintal series) of MARC or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fix in repairs looking mirror of size 600 mm X450 mm all as directed. Make:- Cat part No C 8606 of Parryware or equivalent in makes mentioned in list of makes in Appendix `C'.
Material and labour for rough dressed shahabad stone, 25 mm to 40 mm thick laid over and including 15 mm thick screed bed in cement and sand mortar (1:6), laid and jointed pointed in cement and sand mortar (1:3) etc complete all as specified and directed by Engineer-in-Charge
Material and labour for 75 mm thick plain cement concrete 1:4:8 type D2, using 40 mm graded stone aggregate as in sub base etc complete all as specified and directed by Engineer-in-Charge
M&L for Filleting in any position and to any shape in cement lime mortar 1:4 including all mitres, stops, (exc 25 sqcm but n'exc 50 sqcm etc complete all as specified and directed by Engineer-in-Charge
Material and labour for glazing with 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge
M&L machined pressed precast concrete interlocking paver block glossy with grey cement and pagment, any shpae and size confirming to IS 15658-2006 of 60mm thickness M-35 grade over a stone dust cushion of 30mm thick etc complete all as specified and directed by Engineer-in-Charge
M&L for Filleting in any position and to any shape in cement lime mortar 1:4 including all mitres, stops, (exc 25 sqcm but n'exc 50 Sqcm etc complete all as specified and directed by Engineer-in-Charge
M&L for chequred cement concrete tiles 20X20X25mm thick set jointed & pointed in neat cement slurry in floor with grey cement & pigment over and including 15mm thick screed bed in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
S&F tubular towel rail CP 20mm dia D type 60cm long both flanges brass chronum plated etc complete all as specified and directed by Engineer-in-Charge
Material & labour for 150 mm bore Reinforced cement concrete pipe, type NP2 , haunching against the sides of pipe in PCC 1:4:8 type D-2 using 40mm graded mechanically crushed stone aggregates and making necessary connection after cutting into existing sewer line/manhole to make it functional etc complete all as specified and directed by Engineer-in-Charge
Supplying and fixing precast manhole cover (LD) of size 18" x 18" made up of steel fiber reinforced concrete M-30 grade as per IS etc complete all as specified and directed by Engineer-in-Charge
PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates as in surface channel & drain etc complete all as specified and directed by Engineer-in-Charge
Material & Labour for rendering 10 mm thick in cement and sand mortar (1:40 on concrete surfaces of wall finished even & smooth without using extra cement mixed with water proof compound @ 3 % of the weight of cement as per the manufecturer's instructions etc complete all as specified and directed by Engineer-in-Charge Note :- WPC shall be measured and paid separetely.
Supply only integral water proofing compound etc complete all as specified and directed by Engineer-in-Charge
Cutting into existing manholes for connecting new drains 200mm internal dia of pipe making good to pipe abd rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 smooh finished and reforming benching as required etc complete all as specified and directed by Engineer-in-Charge
M&L precast cement concrete block masonry type C1 (1:3:6) with solid blocks,exc 10 cm in width and setting in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
Supply and fix rotational moulded polyethylene water storage tanks double layer ISI marked conforming to IS 12701-1996 (cylindrical vertical with closed top) and made out of virgin FDA approved polyethylene material of 2000 litres capacity hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting complete all as specified and directed.
S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall,fixed with self tapping screws etc complete all as specified and directed by Engineer-in-Charge
S&F for rolled mild steel in trusses (framed), trussed, purlins, (beam, tee, angle) channel or flat sections including distance pieces, cleats etc, with Fe 410-W (Gde E-250) quality -B etc complete all as specified and directed by Engineer-in-Charge
Taking down carefully aluminium point wiring (light, fan, bell, socket, power point etc) with or without conduit, casing caping, along with all connected accessories such as ceiling rose, switches, sockets, switch boards, fan regulator etc complete all as specified and directed by Engineer-in-Charge
M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn through and including PVC Casing and capping ISI Marked with necessary accessories with androvision of pressed steel terminal box powder coated of suitable size with 3 mm thick plastic laminated sheet by using CP machine screw for housing of switch/socket/regulators etc including 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following :- Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc
One light point controlled by one, one way switch single pole
One fan point controlled by one, one way switch single pole
One 3 pin 5 Amps socket out let on independent board.
One 3 pin 5 Amps socket out let on same board.
One bell point controlled by one bell push on independent board
All as per Item No 90 here-in-before but 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board
S&F Switch Piano Flush type 230/250 Volt, 5 Amps single pole one way, etc complete all as specified and directed by Engineer-in-Charge
S&F bell push, switch flush type, 5 Amps etc complete all as specified and directed by Engineer-in-Charge
S&F bell, AC, 230 volts single pole etc complete all as specified and directed by Engineer-in-Charge
S&F stepped type electronic fan Regulator flush type on the existing phenolic laminated etc, as reqd single pole 240 volts grade 100 watts heavy duty ISI marked.
S&F switch socket combination multi purpose 2 in 1, 6 pin 5 Amps, flush type ISI marked etc complete all as specified and directed by Engineer-in-Charge
S&F switch socket combination 5 in 1, 5 Amps/15Amps, flush type ISI marked etc complete all as specified and directed by Engineer-in-Charge
S&F ceiling rose surface bakelite 65mm x 50mm three etc complete all as specified and directed by Engineer-in-Charge
S&F lamp holder PVC/Polycarbonate type with cord grip cap suitable for pendant fittings etc complete all as specified and directed by Engineer-in-Charge
S&F in replacement double door Sheet metal enclosures factory made DBs 8 way, 240 volts protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 100 A copper Busbar, With Neutral bar, Earthbar and Cable lies for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Engineer-in-Charge. Make: Legrand, Cat No. : 507611 or equivalent in makes mentioned in list of makes in Appendix `C'
S&F Isolators of the under mentioned type and rating and fixing in DBs (DBs measured and paid for separately under relevant item of this BOQ Note :- Make of the isolator should be the same as that of DB) for the following :-
(a) Supply & fixing MCB , SP, AC, 240 volts of 06 to 32 Amps, 10 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge. Make: Legrand, Cat No. : 4085-87 to 90,92,93,94,95 or equivalent in makes mentioned in list of makes in Appendix `C'
(b) Supply & fixing MCB, SPN, AC, 240 volts of 32-63 Amps, 10KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge Make: Legrand, Cat No. : 4086-17 to 20 or equivalent in makes mentioned in list of makes in Appendix `C'
Taking down Existing tube light fitting & Supply & fix LED tube light aling with fixture, 20W etc complete all as specified and directed by Engineer-in-Charge
M&L Earthing complete with galvanized earth plate electrode 600x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 5 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-0 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe complete all as spfd and as directed. connected to earthing list point etc complete all as specified and directed by Engineer-in-Charge
M&L for sub main wiring with two runs of PVC insulated and unsheathed FRLS cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through existing conduit and 4 Sqmm single core multisranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire etc complete all as specified and directed by Engineer-in-Charge (Note : Two runs of conductor with one run of earth wire and PVC casing & capping will be measured & paid as one unit)
Taking out lod building security light (HPSV/Tube light fitting) & S&F LED bldg security light 30W IP 65 etc complete all as specified and directed by Engineer-in-Charge
Supply and fix heavy duty exhaust fan, 300 mm sweep, 900 RPM, 230 V, 50 Hz with fixing of fan duly grouted in bolts and connecting with 3 core flexible copper cable of size 1.5 Sqmm all as directed including making holes in wall/window alletc complete all as specified and directed by Engineer-in-Charge
M/s. A P INFRA
M/S. M. F. Sharif & Co.
M/s.Abhay Kulkarni and Associates
MS. G.A. CONSTRUCTION
Siddhant Hukumchand kumath
M/s AG PATHAN
Ms. S.K. ASSOCIATES
M/S-B.R.SONAWANE
M/s. Sagar Traders
M/s Meher Construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .