Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC | L1 | Accepted-AOC Awarded as a lowest (L1) | |
| 2 | L2₹35.3 L+₹3.4 L (10.6%)Rejected-AOC B 3 3 DHANALAXMI PARK OPP PMT BUS DEPOT BHUSARI COLONY PAUD ROAD KOTHRUD PUNE 411 038 | PUNE | PUNE | MAHARASHTRA | 411038 | L2 | Rejected-AOC Being Second lowest (L2) | |
| 3 | L3₹35.9 L+₹4.0 L (12.5%)Rejected-AOC 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L3 | Rejected-AOC Being third lowest (L3) | |
| 4 | L4₹36.2 L+₹4.3 L (13.4%)Rejected-AOC | L4 | Rejected-AOC Being Fourth lowest (L4) | |
| 5 | L5₹36.4 L+₹4.5 L (14.1%)Rejected-AOC 123 23 1 SHRISANT APARTMENT MANGALMURTI NAGAR PASHAN SUTARWADI ROAD PASHAN PUNE MAHARASHTRA 411021 | PUNE | MAHARASHTRA | 411021 | L5 | Rejected-AOC Being Fifth lowest (L5) |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
12 Mar 2021, 6:00 pmClosed
GERD PASHAN PUNE
GERD PASHAN PUNE
REPAIRS MAINTENANCE OF INTERNAL ELECTRIFICATION INCLUDING FLP FITTINGS IN ARDE PUNE UNDER GE RD PASHAN PUNE
2021_MES_421421_1
GERD/PSN/TOKEN/38 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GERD PASHAN PUNE
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GERD PASHAN PUNE
₹70,000
Yes
27 Mar 2021
12 Feb 2021
16 Mar 2021
12 Feb 2021
12 Mar 2021
26 Feb 2021
12 Feb 2021 - 25 Feb 2021
Amount
CIVIL WORKS
Material and labour for disconnecting and taking down old unserviceable point wiring alongwith accessories switches, switch sockets, ceiling rose, switch board and main switch board etc., complete and making good the disturbed surfaces all as specified and directed by Engineer-in-charge and making good the disturbed surfaces all as specified and directed by Engineer-in-charge.
Material and labour for disconnecting and drawing out existing U/S flame proof point wiring from conduit with dismentaling conduit and dismentaling accessories such as bends / tee/ elbow / junction boxes/ union etc complete for taking schedule of credit and making good the disturbed surfaces all as specified and directed by Engineer-in-charge.
Supply and fixpoint wiring with 1.5 Sqmm size, PVC insulated and unsheathed 1100 volts grade single core multistrand copper conductor FRLS cable drawn into & including PVC casing capping with all fittings and accessories with PVC box fixed with CP screws and cup washers for mounting fitting like switches, sockets and fan regulators etc; including one continous run of PVC insulated green colour 1.5sq mm multi stranded copper conductor cable earth wire and connected to common earth dolly complete all as specified and directed for the following :- (a) one light /fan point controlled by one; one way switch.
(b) one 3 pin socket out let 5 amp independent point.
(c) one 3 pin socket out let 5 amp point on the same board with other switches.
All as per Ser no item 3 above but with 4.0 sq mm size pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board including one continuos run of PVC insulated green in colour 4.0 sqmm multistranded copper conductor earth wire connecting to earth dolly.
Supply and fixpoint wiring with 1.5 Sqmm size, PVC insulated and unsheathed 1100 volts grade single core multistrand copper conductor FRLS cable drawn into & including PVC conduit with all fittings and accessories with PVC box fixed with CP screws and cup washers for mounting fitting like switches, sockets and fan regulators etc; including one continous run of PVC insulated green colour 1.5 sq mm multi stranded copper conductor cable earth wire and connected to common earth dolly complete all as specified and directed for the following :- (a) one light /fan point controlled by one; one way switch.
(b) one 3 pin socket out let 5 Amp independent point.
(c) one 3 pin socket out let 5 amp point on the same board with other switches.
All as per Ser item 7 above but with 4sq mm size pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board including one continuos run of PVC insulated green in colour 4.0 sqmm multistranded copper conductor earth wire connecting to earth dolly.
Material and labour for wiring with 1.5 Sqmm size, PVC insulated and unsheathed 1100 volts grade single core multistrand copper conductor FRLS cable rawn into existing PVC conduit/ERW steel conduit concealed into wall or on surface with all fittings and accessories with PVC box fixed with CP screws and cup washers for mounting fitting like switches, sockets and fan regulators etc; including one continous run of FRLS PVC insulated green colour 1.5sq mm multi stranded copper conductor cable earth wire and connected to common earth dolly complete all as specified and directed and directed for the following :- (a) one light /fan point controlled by one; one way switch.
(b) one 3 pin socket out let 5 amp on independent board
(c) one 3 pin socket out let 5 amp point on the same board with other switches.
All as per sl item 11 herein before but with 4sq mm size FRLS PVC insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board including one continuos run of FRLS PVC insulated green in colour 4.0 sqmm multistranded copper conductor earth wire connecting to earth dolly..
Material and labour for flame froof Point wiring with 1.5 Sqmm, FRLS PVC insulated and unsheathed FRLS cable of copper conductor, multistranded, single core 1100 volts grade in stove enameled / ERW steel conduit along with flame proof accessories on surface of walls, ceiling etc; for flame proof application and connecting up of the fitting, including 1.5 sqmm dia FRLS PVC insulated copper conductor to PVC insulated unsheathed FRLS cable green in colour for earth countinuity and connected to earth dolly complete all as specified and directed for the following :- (a) One flameproof light point / fan point controlled by one; single pole switch/ Rotary switch.
All as per SI item No. 15 here-in-before but with 4.0 sqmm cable for 16 Amps, 3 pin switch socket combination.
Supply and fix Flame proof weather proof bend 3/4" (20 mm dia bore) complete all as specified and directed.
Supply and fix Flame proof weather proof bend 1" (25 mm dia bore ) complete all as specified and directed.
Supply and fix Flame proof weather proof inspection elbow 3/4" complete all as specified and directed.
Supply and fix Flame proof weather proof inspection elbow 1" complete all as specified and directed.
Supply and fix FLP junction boxes LM-6 with plain cover suitable for 3 Way suitable for 20 mm to 25 mm dia conduit complete all as specified and directed.
Supply and fix FLP junction boxes LM-6 with plain cover suitable for 4 Way suitable for 20 mm to 25 mm dia conduit. complete all as specified and directed.
Supply and fix Flameproof switch of LM 6 body, rotary switch, SP, 16 Amps for ON / OFF light / fan point to operate on single phase 230 Volts, AC CMRI certified IS-2145 complete all as specified and directed.
Material and labour flameproof switch socket combination suitable for 2P+N 16 Amps, 250 volts including plug and top, LM-6 body, CMRI certified, ISI marked all as specified and directed
Material and labour for flameproof switch socket combination 2P+N suitable for 25 Amps to 32 Amps, 250 volts including plug and top, LM-6 body, CMRI certified, ISI marked all as specified and directed and directed.
Material and labour for flameproof switch socket combination suitable for 3P+E 16 Amps 500 volts including plug and top, LM-6 body, CMRI certified, ISI marked all as specified and directed and directed.
Material and labour for flameproof switch socket combination suitable for 4P+E 32 Amps 500 volts including plug and top, LM-6 body, CMRI certified, ISI marked all as specified and directed and directed
Material and labour for flameproof switch socket combination suitable for 3P+N 32 Amps, TPN, 415 volts including plug and top, LM-6 body, CMRI certified, ISI marked all as specified and directed and directed.
Material and labour for flameproof switch socket combination suitable for 4P+N 63 Amps, TPN, 415 volts including plug and top, LM-6 body, CMRI certified, ISI marked all as specified and directed and directed
Supply and fixing FLP flexible metalic hose conduit 20 mm dia 300 mm long all as speified and directed
Material and labour (in repairs) for Flame proof Sub main wiring with single core, multistranded FRLS (flame proof) PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn in and including steel rigid conduit , conduit fittings and accessories on surface wall/roof/floor with one run of suitable size FRLS (flame proof) PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring all as specified and directed and directed for following size . NOTE :- 4 runs of main wire alongwith 2 run of earth wire and one run of steel conduit pipe shall be measured as one unit a) 4 X 6 sq mm + 2 X 4 sq mm earth wire
b) 4 X 4 sq mm + 2 X 2.5 sq mm earth wire
c) 4 X 2.5 sq mm + 2 X 1.5 sq mm earth wire
d) 4 X 10.0 sq mm + 2 X 6.0 sq mm earth wire
Material and labour for sub main wiring with single core, multistranded FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn in and including PVC rigid conduit , conduit fittings and accessories on surface wall/roof/floor with one run of suitable size FRLS PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly taking down existing submain wiring complete all as specified and directed for the following size :- NOTE :- 4 runs of main wire alongwith 2 run of earth wire and one run of steel conduit pipe shall be measured as one unit a) 4 X 6 sq mm + 2 X 4 sq mm earth wire
b) 4 X 4 sq mm + 2 X 2.5 sq mm earth wire
c) 4 X 2.5 sq mm + 2 X 1.5 sq mm earth wire
d) 4 X 10.0 sq mm + 2 X 6.0 sq mm earth wire
Material and labour for sub main wiring with single core, multistranded FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn in and including PVC casing capping, fittings and accessories on surface wall/roof/floor with one run of suitable size FRLS PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly taking down existing submain wiring all as specified and directed and directed for following size :- NOTE :- 2/4 runs of main wire alongwith 1/2 run of earth wire and one run of steel conduit pipe shall be measured as one unit a) 4 X 6 sq mm + 2 X 4 sq mm earth wire
b) 4 X 4 sq mm + 2 X 2.5 sq mm earth wire
c) 4 X 2.5 sq mm + 2 X 1.5 sq mm earth wire
d) 2 X 2.5 sq mm + 1 X 1.5 sq mm earth wire
e) 2 X 4.0 sq mm + 1 X 2.5 sq mm earth wire
f) 2 X 6.0 sq mm + 1 X 4.0 sq mm earth wire
Supply and fix in repairs LED Flameproof fluorescent tube light 1 X 18/20 watts with lumen out put not less than 2000 Lumens fittings,body made out of aluminium alloy LM -6 body epoxy painted with wire guard relfector, flame proof clear glass tubing to house LED fluorscent tube along with suitable integrated electronic drivers; complete including 1 x 18/20 W LED fluorescent tube fixed to wall / roof including necessary fixing arrangments CMRI approved and connecting up completely including taking down existing fittings all as per IS-2148 complete all a specified and directed Note : Flexible conduit / junction box will be measured and paid seperately.
Supply and fix in repairs LED Flameproof fluorescent tube light 2 X 18/20 watts with lumen out put not less than 4000 Lumens fittings,body made out of aluminium alloy LM -6 body epoxy painted with wire guard relfector, flame proof clear glass tubing to house LED fluorscent tube along with suitable integrated electronic drivers; complete including 2 x 18/20 W LED fluorescent tube fixed to wall / roof including necessary fixing arrangments CMRI approved and connecting up completely including taking down existing fittings all as per IS-2148 and all as specified and directed. Note : Flexible conduit / junction box will be measured and paid seperately.
Supply and fix in repairs Flameproof / Weatherproof LED Well Glass Light Fitting suitable for 44 Watt with lumen out put not less than 4400 Lumens, body made out of aluminium alloy LM -6 body epoxy painted with wire guard relfector, flameproof Heat Resistant Clear Toughened ‘Type‐ A’ with Led chip - Osram smd / Citizen / Epistarincluding suitable electronic including necessary fixing arrangments and connecting up completely including taking down existing fittings all as Gas Gr. IIA, IIB Certified by CMRI Dhanbad & CCOE (PESO) Nagpur along with ISI marking Glass complete all as specified and directed.
Supply and fix in repairs Flameproof / Weatherproof LED Well Glass Light Fitting suitable for 60 Watt with lumen out put not less than 6000 Lumens, body made out of aluminium alloy LM -6 body epoxy painted with wire guard relfector, flameproof Heat Resistant Clear Toughened ‘Type‐ A’ with Led chip - Osram smd / Citizen / Epistarincluding suitable electronic including necessary fixing arrangments and connecting up completely all as Gas Gr. IIA, IIB Certified by CMRI Dhanbad & CCOE (PESO) Nagpur along with ISI marking Glass including taking down existing fittings complete all as specified and directed
Supply and fix Switch piano, flush type single pole, one way, 5 Amps, 240 volts all as specified and directed.
Supply and fix switch socket combination 2 in 1, 3 pin, 5 Amp, flush type all as specified and directed.
Supply and fix switch socket combination 5 in 1, 6 pin, 5A/16A flush type all as specified and directed.
Supply and fix Ceiling rose surface Bakelite, 65x50mm three terminals 230 Volts, AC Single phase all as specified and directed.
Supply and fix stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed.
Dismantling carefully disconnecting and bringing down the existing unserviceable flame proof tube light fittings, 1 x 40 / 36 watt 2 x 40 / 36 W of any type and make from wall/ceilings at any height and carrying out necessary repairs, cleaning of cover and repairs to internal wiring and holders etc for fixing LED Tube light., at any height and refixing to the position all as specified and directed and directed by Engineer-in-Charge. Notes : (i) Spare parts required to be replaced will be measured and paid seperatly as "supply only"
Supply only the following item all as specified and directed:- (a) LED 20 watt retrofit tube light of size 4 feet crystal glass double side connecion suitable for installation in existing T8 tulight with G13 lamp holder .
(b) LED retrofit lamp screw/pin type 30 watts to be incorporated in flame proof HPMV fittings
(c) LED retrofit lamp screw/pin type 40 watts to be incorporated in flame proof HPMV fittings
Supply and fix in repairs LED tube light fitting 2X18 W, 4 feet long wall mounted anodized aluminum extruded heat shrink provided for efficient heat deception and interchangeable integrated electronic driver luminaries LED as light sources housing complete with all accessories including suitable lamp, internally prewired up with twin core twisted flexible copper cable of suitable size including taking down existing fittings all as specified and directed and as directed
Supply and fix in repairs LED tube light fitting 1X20 W, 4 feet long wall mounted anodized aluminum extruded heat shrink provided for efficient heat deception and interchangeable integrated electronic driver luminaries LED as light sources housing complete with all accessories including suitable lamp, internally prewired up with twin core twisted flexible copper cable of suitable size including taking down existing fittings all as specified and directed and as directed
Supply and fix in repairs LED tube light fitting 1X10 W, 2 feet long wall mounted anodized aluminum extruded heat shrink provided for efficient heat deception and interchangeable integrated electronic driver luminaries LED as light sources housing complete with all accessories including suitable lamp, internally prewired up with twin core twisted flexible copper cable of suitable size including taking down existing fittings all as specified and directed and as directed
Supply and fix new generation energy saving and enviromental freindly LED street light 20 watt made up of pressure die cast aluminum housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK 07complete all as specified and directed including taking down existing fitting all as specified and directed directed
Supply and fix new generation energy saving and enviromental freindly LED post of lantern 35 watt long life, aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs including taking down existing fitting all as specified and directed and directed
Supply and fix recessed mounted adjustable down light 16/18 watt fitting with high power LEDs including taking down existing fitting and required modification for fixing new down lighter including taking down existing fittings all as specified and directed and directed by Engineer-in-Charge
Supply and fix LED Luminaires 2 x 2 recessed mounting aesthetically designed glare free symmetrical illumination 42 W delivery lumens are not less than 4200 lumens / watts, 230V energy efficient box type white epoxy powder coated aluminiunm extruded housing with LEDs and drive comlete, connector block etc suitable for POP ceiling complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.,complete with all accessiories including taking down existing fitting complete all as specified and directed.
Supply and fixing, connecting and testing MCB 10 kA C curve on existing distribution board out going/incoming any type and connecting to existing circuits complete all as specified and directed and as directed for the following sizes :- a) MCB SP 6 to 40 amps
b) MCB SPN 16 to 40 amps
Supply and fix in repairs TPN distribution board factory made double door flush type as per IS 8623 made from sheet metal duly powder coated for single phase outgoing and three phase incomer, with 200 Amps rated bus bar, 415 V, 4 way flush with wall complete with all accessories all as directed by Engineer-in-Charge.
Supply and fix in repairs TPN distribution board factory made double door flush type as per IS 8623 made from sheet metal duly powder coated for single phase outgoing and three phase incomer, with 200 Amps rated bus bar, 415 V, 8 way flush with wall complete with all accessories all as directed by Engineer-in-Charge.
Supply and fix in repairs SPN distribution board factory made double door flush type all as per IS 8623 made from sheet metal duly powder coated to be fixed flush with wall complete with all accessories all as directed by Engineer-in-Charge for the following ways:- a) 8 way SPN
(b) 12 way SPN
Supply and fix in repair of MCCB suitable KA rating ,at 415 Votls AC 50 Hz Thermal relesed, adjustable type, conforming to IS- 60947-2 including suitable arrangement to existing LT panel for proper seating/opration complete all as specified and directed for the following capacities:- a) 63 amps 25 KA capacity 4 pole
Taking down carefully ceiling fans/wall mounted fans/pedestal fans/exhaust fans of any sweep /size from location of any height after disconnecting from the live line,transpotation the same from site to workshop for repair including dismantling of the fan blades,motor,brackets for repairs and reassembling it complete after overhaulling oiling including gresing after replacing unserviceable parts and refixing at original location including painting with one coat of synthetic enamel paint of white colour or any approved colour after cleaning the fan surfaces and testing at site all as directed by engineer-in-Charge and specified. Notes : (i) Spare parts required to be replaced except minor items will be measured and paid sepaterly as "Supply only". (ii) Painting of ceiling fans /exhaust fans will be measured sepaterly. (iii) Rewinding of ceiling fans/exhaust fans will be measured and paid sepaterly.
Material and labour for rewinding of ceiling fans 1200 to 1400 mm sweep /wall mountedfans/pedestal fans of any size including dismantling the ceiling fan motor and removing the burnt out winding, cleaning the starter with CTC soloution to remove the burnt slots.Rewinding the same with super enameled copper wire of suitable gauge and size / number of turns including insulation varnishing and reassembling completely, complete all as specified and directed.
All as per Sl item No 73 here-in-before but exhaust fan size 300 to 450 mm sweep of any type.
Supply only following spare parts /items of ceiling fans /exhaust fans / wall mounted fans and pedestal fans of various types all as specified and directed:- (a) Flexible twin rwisted copper wire two core of size 23 / 0.0076 mm upto 1.5 metre length.
(b) Ball bearing suitable for Ceiling fan 1200/1400 mm sweep.
(c). Ball bearing suitable for exhaust fan 400-450 mm sweep.
(d). Ball bearing suitable for exhaust fan upto300mm sweep.
(e). Condensor 2.5 mfd, 230 V, suitable for ceiling fan / wall fan / exhaust fan of any sweep and size
(f). Condensor 4 mfd, 230 V suitable for wall mounting fan / exhaust fan / pedestalfan of any sweep / size.
(g). Rubber reel with MS nuts and bolts with appropriate size locking pins suitable for ceiling fan down rod of any size / dia as per requirment at site and to be fixed in position.
(h). PVC canopy top or bottom complete for ceiling fans down rod suitable for any size / sweep.
(j). Gun metal bushing for ceiling fan 1200 / 1400 mm sweep.
(k). Gun metal bushing for Exhaust fan upto 300 mm sweep.
(l). Gun metal bushing for Exhaust fan upto 450 mm sweep.
Material and labour for painting of ceiling fan / exhaust fan and wall mounted fans / exhaust fan / air circulators of any size or sweeps complete including fan blades, down rod, fan motor body after dusting, cleaning and painting with white syenthetic enamel paint by spray paint and pasting soft stickers indicating MES No of 25 mm size each letter with black syenthetic enamel paint all as specified and directed.
Supply and fix (in repair) energy saving 5 star rating Ceiling fan AC single phase 230/240 Volt 50 Hz, 50 watt power consumption, powerfull motor with CRNO lamination of size 1200 mm sweep with regulator including making required fixing arrangement on ceiling and depositing old fan to MES storer yard complete all as specifed and directed.
Supply and fix in replacement heavy duty rating Exhaust fan AC single phase 230/240 Volt 50 Hz, powerfull motor with CRNO lamination of size 300 mm sweep and depositing old fan to MES storer yard complete all as specified and directed
Supply and fix in repair pedestal air circulator with oscillation type, AC single phase 230/240 Volt 50 Hz, powerfull motor with CRNO lamination of size 600 mm sweep with built in speed regulator and depositing old fan to MES storer yard complete all as specified and directed
Supply and fix ( in repair) wall mounted Air circulator with oscillation type, AC single phase 230/240 Volt 50 Hz, powerfull motor with CRNO lamination of size 600 mm sweep with including making required fixing arrangement on wall and depositing old to MES storer yard complete all as specified and directed
Material and labour for Testing of conventional type lightning protection system as specified here under at various locations as directed by Engineer-in-charge and as specified :- (a) Before testing a visual check to be carried out jointly by the contractor, Engr-in-Charge and rep of users for the mechanical condition of all conductors, bonds, joints. (b) Testing continuity and resistance of conductors, ohmic resistance of lightning conductor system complete with air termination but without the earth electrode connection and recording results. (c) Testing of each earth electrode point without continuity conductors, air termination and ring conductor. (d) Testing the resistance to earth of the whole installations with all earth electrodes continuity, conductors, air termination and bonding of other services and results are to be recorded. (e) All above testing are to be done in accordance with STEC Pamphlate No. 7 and IS 2309, 1999 (2nd revision) and IS 3043, 1987. The results are to be recorded in a prescribed format duly signed by contractor, Engr-in-Charge and rep of users and to be submitted by contractor in triplicate. Notes : (i) The testing mentioned above will be conducted only after rectifying the defects observed during visual check. (ii) Unit rate quoted is deemed to be inclusive of writing board in white colour letters n.exc. 2 cm height on the black colour back ground on wall such as - Tested on, Due date of testing, E.g. EP No. 1-ER 10 ohms. EP No. should be mentioned on individual earth pits and ER value of installation etc. all as specified and directed and directed by Engr-in-Charge. (iii) Contractor has to make arrange for necessary testing instruments of suitable range duly latest calibrated (certificates to be produced). The rate quoted is deemed to be include the above provision. (iv) If ohmic resistance value exceeds 1 ohm the system to be rectified by cleaning with CRC solution, tightening, replacement of bolts / nuts, rivets, etc; to get value below 1 ohm.` (v) In case resistance value of earthing exceeding more than 10 ohms, the existing earthing to be replaced and shall be measured and paid under appropirate item here-in-after. (vi) Material and labour required for rectification of defects observed will be measured and paid separately under relevant items of sch 'A'.
Material and labour in repair of lightning protection system mounted on top of steel tubular poles/ PCC poles/ iron structure of any type and height 15m -18m above ground level including T & P and necessary arrangmentall as directed by Engineer-in-Charge and as specified. Note : LP system for complete bldg/magzine/shed/lab will be mesured as on unit.
Taking down / dismantling existing perished aluminium strip of size 25 x 3 mm from any height of roof top / on walls of conventional type lightening protection network system complete all as specifiec and as directed.
Re-fixing old serviceable aluminium strip of size 25 x 3 mm obtained from taking down on existing PCC block at any height on roof top, on existing insulators any type on walls including jointing the system of conventional type lightening protection network and making good the disturbed surface of walls / roof top match with existing surface complete all as specified and directed and as directed.
Taking down / dismantling existing perished GI strip of size 32 x 6 mm from on walls / buried in to ground of conventional type lightening protection network system complete all as specified and directed and as directed.
Fixing only old serviceable GI strip of size 32 x 6 mm as obtained from taking down, on existing walls / buried under ground, on existing insulators any type including jointing the system of conventional type lightening the system of conventional type lightening protection network and making good the disturbed surface of walls complete all as specified and directed and as directed.
Material and labour in repair for aluminium strip of size 25x3mm fixed on PCC block with epoxy based insulator of 35mm size at distance / interval not more than 1.0 m for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut and bolt, gutties, screws etc complete all as specified and directed. Note (i) Epoxy base insulator and PCC block will be measured and paid separately under relevant items of BOQ respectively. (ii) Unit rate quoted is deemed to be inclusive cost of one lead joint and 2 Nos GI nuts, bolts washers, screws and necessary T&P and machining work reuired at site.
Material and labour for galvanised iron strip in replacement of size 32 x 6 mm burried in ground or fixed on wall with suitable 35 mm size epoxy base insulator fixed on wall / floors fixed at distance / interval not more than 1.0 m and connected to test point including bending, jointing at test points with 2 Nos GI nuts, bolts, with lead washers, jointing strips at all joints as directed by Engr-in-Charge and specified.
Material and labour in repair for copper strip of size 25x3mm fixed on PCC block with epoxy based insulator of 35mm size at distance / interval not more than 1.0 m for down conductor air terminal network including drilling two Nos holes at each joint, one set of copper strips, two sets GI nut and bolt, gutties, screws etc complete all as specified and directed. Note (i) Epoxy base insulator and PCC block will be measured and paid separately under relevant items of BOQ respectively. (ii) Unit rate quoted is deemed to be inclusive cost of one lead joint and 2 Nos GI nuts, bolts washers, screws and necessary T&P and machining work reuired at site.
Supply and fixing in repairs of epoxy base insulator of suitable size, 35mm height fixed on PCC blocks/ wall or MS angle/ Pipe or on traverse etc. all as directed by Engineer-in-Charge and specified.
Material and labour in repair for PCC block of size 150mm x 150mm x 150mm in PCC (1:3:6) type C-1 with 20mm stone graded crushed stone aggregate including necessary form / mould for fair and even surfaces, air termination rod / GI strip etc., including removal of old concrete complete all as directed and specified.
Material and labour for dismentling of existing inspection box of any material shape and size including supply and fixing of new inspection box / cover box of size 250mm x 150mm x 100mm made out of 3 mm thick MS sheet with hinged front opening cover including provision of fixing 2 Nos epoxy insulators and insulating PVC sheathed for incoming and outgoing aluminium / GI strips for proper insulation etc compelte all as specified and directed.
Supply and fix in replacement of air termination single pointed aluminium rod of 12 mm dia 300 mm long fixed to aluminium strip 25mm x 3mm including drilling holes, nuts, bolts washers for resting/ supporting of air terminals etc, complete all as directed and specified.
Material and Labour for dismenltling and taking down from roof / poles air termiantion single pointed rod 12 mm dia 1000 mm long and keeping in safe custody including making good the disturbed surfaces after resuse at specfied location after replacement of PCC block, insulator, strip and connect to aluminium strip including 2 No drilling holes, nuts, bolts washers complete all as specified and directed
Supply and fixing in repairs air termiantion single pointed rod 12mm dia 300 mm long on roof top existing net work system or any other new net work system after replacement of PCC block, insulator, strip and connect to aluminium strip including 2 No drilling holes, nuts, bolts washers complete all as specified and directed.
Material and labour (in repair) for earthing with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground earth pit not less than 2.25 m deep below ground level with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised strip 32 x 6 mm by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No. 03 of SSR Part I connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber including necessary formwork / mould for fair and even surfaces, precast RCC 1:2:4 type B0 chamber cover slab, GI funnel, with GI watering pipe 20 mm bore light grade, wire mesh, protection pipe 40 mm bore GI pipe light gde for earth lead upto 7.50 m long including testing complete all as specified and directed. Note : Test report shall be prepared and submitted by the contractor in triplicate duly obtaining signatures of MES JE / AGE & PMG / user. Test results are to be written in letters of 20mm height in white colour on black paint back ground.
Material and labour (in repair) for earthing with copper earth plate electrode 300mm x 300mm x 3 mm thick buried directly in ground earth pit not less than 2.25 m deep below ground level with top edge of the plate not less than 1.5 m below normal ground level connected to copper strip 20 x 3 mm by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No. 03 of SSR Part I connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber including necessary formwork / mould for fair and even surfaces, precast RCC 1:2:4 type B0 chamber cover slab, GI funnel, with GI watering pipe 20 mm bore light grade, wire mesh, protection pipe 25 mm bore GI pipe light gde for earth lead upto 7.50 m long including testing complete all as specified and directed and directed by Engineer-in-Charge. Note : (i) Test report shall be prepared and submitted by the contractor in triplicate duly obtaining signatures of MES JE / AGE & PMG / user. Test results are to be written in letters of 20mm height in white colour on black paint back ground. (ii) Copper strip beyond 7.5 metre will be measured and paid for seperately
Material and labour in replacement of GI funnel, wire mesh, earth pit Precast RCC (1:2:4) type B0 cover complete all as specified and directed.
Material and labour (in repair) for GI tubing light grade of size 40 mm bore for connecting to air termination rod / protection to GI strip complete tncluding Brackets for fixing all as directed and specified.
Material and labour in repair to 3D LED sign alumininum English letters made with the process of automatic channel letter bending machine in flanging & notching in 1mm aluminium coil with 1mm aluminium backing fibre laser cut and clinched to the coil using clinching machine front will be 3mm arcylic (Astarglas Indoneia) locked in 30mm aluminium extruded profile bent on automatic channel bending machine. Light source LEDs with waterprof drivers inclduing wiring of havells/polycab/finolex complete design size english letters ARDE-72" and rest proportion complete all as specififed and directed.
Baljeet Singh Choudhari
M/S - KRUPA ELECTRICALS
M/S - FRONTLINE ELECTRO SYNDICATE
R. K. Industrial Fabricators
MAYUR ELECTRIC SERVICES
Borole Electricals
Neha Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .