| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹46.1 L+₹13.3 L (40.6%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹46.4 L+₹13.6 L (41.5%)Rejected-Finance LODHI NAGAR NEAR TEACHERS COLONY GALI NO 4 MAHOLI ROAD MATHURA U P 281004 | MATHURA | MATHURA | UTTAR PRADESH | 281004 | L3 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
20 Dec 2021, 6:00 pmClosed
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
REPAIR MAINT OF COOLING APPLIANCEs SUCH AS ACs WATER COOLERs REFRIGERATORs DESERT COOLERs VOLTAGE STABILIZERs ETC ALONGIWTH CONNECTED WORKS AND REPAIR MAINT OF SUMMER APPLIANCES SUCH AS CEILING FANs EXHAUST FANs FRESH AIR FANs ETC UNDER GE (E) MATHUR
2021_MES_490037_1
8200-1244
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE EAST MATHURA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE EAST MATHURA
₹1 L
27 Dec 2021
24 Nov 2021
22 Dec 2021
24 Nov 2021
20 Dec 2021
8 Dec 2021
24 Nov 2021 - 13 Dec 2021
Amount
Taking down of window/split AC 1.5/2.0 tonne of any make opening complete. Servicing of AC components carefully as cleaning with chemical solution and soft nylon brush and change of air filters,tightnining of loose screw, checking wiring connection and rectification complete assembling the same with body balancing and fixing in position and testing complete. Note :- (i) Cost of unserviceable major parts as required shall be measured and paid separetaly under relevant items under this BOQ. (ii) Servicing of same AC should be after minimum gap of six month of previous servicing.
Supply and fix in repairs compressor sealed unit of the following appliances. New compressor shall be of the same type (rotary/reciprocating) and make Hitachi/Voltas/LG/Carrier/ Blue star as per existing complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed by Engr-in-Charge.
Window type air conditioning of capacity 1.5 Ton.
Window type air conditioning of capacity 2.0 Ton.
Split type AC 1.5 Ton capacity.
Split type AC 2.0 Ton capacity.
Cutting of worn out bottom portion and fabricated welded properly of bottom tray & supply & fixing 20 guage MS CRC sheet for window type ACs capacity 1.5/2.0 ton complete all as specified and directed by Engr-in-Charge.
Re-alignment of split AC 1.5/2.0 ton capacity including cutting of wall and making hole and change of liquid lines position in wall/roof by means of making sufficient grooves/channels and making good the disturbed surface including surface finish to match the exising finish complete including testing all as specified
Supply & fix in repairs running/starting capacitors of the following capacities for Acs. Make :- Siemens/Epcos.
Supply & fix in repairs starting relay suitable for following items:-
Window type room air conditioners of capacity 1.5/2.0 Ton cap.
Split type AC 1.5/2.0 Ton cap.
Supply & fix in repairs thermostats of existing make for following :-
Window type room air conditioners of capacity 1.5/2.0 Ton cap.
Split type AC 1.5/2.0 Tonne cap.
Supply & fix in repairs overload protector of existing make/model for the following :-
Window type room air conditioners of capacity 1.5/2.0 Ton cap.
Split type AC 1.5/2.0 Tonne capacity.
Supply & fix in repairs condenser unit make of copper of the following appliances including making of all connections as specified and directed by Engr-in-Charge. Make :- as per existing
Window type room air conditioning of capacity 1.5/2.0 Ton capacity.
Split type AC 1.5/2.0 Ton capacity.
Supply & fix in repairs of evaporator coil for the following :-
Window type room air conditioning of capacity 1.5/2.0 Ton cap.
Split type AC 1.5/2.0 Ton capacity.
Supply & fix in repairs metal clad/sheet metal plug and socket with a 2 pin and earth plug and 20 Amps SP MCB including making all connections complete.
Supply & fix in repairs of indoor unit of split AC 1.5 ton single phase 230v, including cooling/condensing coil assembly, electric fan motor with blower drum, control panel, front grill, compressor complete set all as specified and directed by Engineer-in-charge.
Supply & fix in repairs of indoor unit of split AC 2.0 ton single phase 230v, including cooling/condensing coil assembly, electric fan motor with blower drum, control panel, front grill, compressor complete set all as specified and directed by Engineer-in-charge.
Supply & fix in repairs power transformer suitable for window/ split type air conditioning of 1.5/2 Tonne cap make as per existing
Complete servicing of voltage stabilizers AC single phase. upto 5 KVA of any make by opening of the body, cleaning of internally, checking and tigtening of all terminal connections including replacement of worn out terminal connectors, screws, bolts complete all as directed by Engr-in-Charge. Note : Unserviceable parts shall be measured & paid separtely as supply only under releavent items of this BOQ.
Supply only main transformer 5 KVA Copper wound 170 to 230V.
Supply only main transformer 3/4 KVA.
Supply only circuit board for time control/cut off for 12V system upto 10-25A suitable of 0.5 to 5 kVA
Supply only electromagnetic relay copper wound 12V ranging 10-25A Suitable for 0.5 to 5 kVA
Supply only voltmeter flush type 230V, 0-300V ranging complete
Supply & fix in repairs of voltage stabilizer 5kVA 230V complete all as directed. Make:- V guard or equivalent approved make given under list of makes
Supply & fix in repairs of voltage stabilizer 4kVA 230V complete all as directed. Make:- V guard or equivalent approved make given under list of makes
Supply & fix in repairs of blower motor double shaft, single/double speed, single phase, AC 230 V of suitable as per existing window type AC 1.5/2.0 TR all as directed.
Supply & fix in repairs of blower motor single shaft, single/double speed, single phase, AC, 230 V suitable as per existing for out door unit of split type AC upto 2.0 TR all as directed.
Supply & fix in repairs of blower motor single shaft, single/double speed, single phase, AC, 230 V suitable as per existing for in door unit of split type AC upto 2.0 TR all as directed.
Supply & fix in repairs heavy duty PVC flexible pipe with necessary fittings /split ACs/Window ACs drains of 15mm dia bore.
Supply & fix in repairs front cover grill suitable for window type room AC of any make and capacity Make as per existing
Supply & fix in repairs Air fillter suitable for 1.5 ton/2.0 ton window type AC .
Supply & fix in repairs air fillter suitable for 1.5 ton/2.0 ton split type AC .
Supply & fix in repairs copper tubing of following flare conforming to relevant IS
12mm dia
6mm dia
Supply & fix in repairs suction/discharge valve for 1.5/2.0 ton AC.
Supply & fix in repairs fan blade set suitable for window/split AC of any capacity
Supply & fix in repairs remote control with PC board complte suitable for 1.5/2.0 tonne capacity split type air conditioneer suitable for existing model
Supply & fix in repairs remote control with PC board complete suitable for 1.5/2.0 tonne capacity Window type AC suitable for existing model
Supply & fix in repairs remote of split/Window AC as per existing model and capacity complete all as specified and directed by engineer-in-chrage.
Supply & fix in repairs of outdoor unit of split AC 1.5 tonne single phase 230V, 5 star rated, inverter technology including compressor, heating coil ,fan motor ,condenser unit,control panel etc complete set all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs of outdoor unit of split AC 2.0 tonne single phase 230V, 5 star rated, inverter technology including compressor, heating coil ,fan motor ,condenser unit,control panel etc complete set all as specified and directed by Engineer-in-charge.
Material and labour for servicing of the following appliances and cleaning the body, storage tank, blow out the condenser coils with air blower, alignment and greasing cleaning of fan bushes thorough checking of wiring and rectification of defects and leakages, cleaning of blockages of drain out-let connections, testing for smooth operation all as specified and directed. Note :- Cost of Gas charging as in topping up as required to maintain desired gas pressure is deemed to be included in the unit rate quoted for this item.
Water coolers of any type and capacity.
Refrigerator of any type and capacity.
Deep Freezers of any type, any make upto 425 ltr capacity
Testing leakage in system by injecting Nitrogen gas upto 300 PSI,rectification leaking spots/joints with gas welding work, filter anti moistoring agent, soldering, brazing, copper capillary tubing of reqd size and cleaning and flushing out complete system with gas making the system leak proof,vaccumising the complete system and supply and charging R-22/R407 refrigerant gas qty as required the following :- Note:- No extra cost shall be paid to the contractor for gas charging (any numbers of times) in case of leakage with in six months of initial gas charging except in case where external damage to the plant is noticed.
Water coolers of any type and capacity.
Refrigerator of any type and capacity.
Deep Freezers upto 425 ltr capacity
Window type AC 1.5/2.0 Ton.
Split AC 1.5/2.0 Ton.
Supply & fix in repairs compressor sealed unit of the following appliances of existing make:- Blue star/voltas/LG or as per existing make complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and directed by Engr-in-Charge.
Water coolers of 40/80 ltr capacity.
Water coolers of 60/120 ltrs to 200 ltr capacity.
Refrigerator of 165-195 ltr capacity.
Refrigerator of 215 ltrs to 310 ltrs capacity.
Deep Freezers upto 425 ltr capacity
Supply & fix in repairs starting relay suitable for existing makes
Water coolers of 40/80/120/150/200 ltr capacity.
Refrigerator for any capacity upto 310 liters.
Deep freezers of any make and model upto 425 ltrs capacity.
Supply & fix in repairs thermostats suitable for existing makes
Water coolers of any make and capacity.
Refrigerator of any make and capacity.
Deep freezers of any make any model upto 425 ltrs capacity.
Supply & fix in repairs overload protector suitable for existing makes
Water cooler of any make and capacity.
Refrigerator of any make and capacity.
Deep freezers of cap any make any model upto 425 ltrs.
Supply & fix in repairs condenser unit of the following appliances including making of all connections as specified and directed by Engr-in-Charge.
Water cooler of any make and capacity.
Refrigerator of any make and capacity.
Deep freezers of any make and model upto 425 ltrs cap.
Supply & fix in repairs cooling coil of following appliances:-
Water cooler of any make and capacity.
Refrigerator of any make and capacity.
Deep freezers of any make and model upto 425 ltrs capacity.
Supply & fix in repairs float valve of water cooler of any capacity.
Supply & fix in repairs PVC insulated and sheathed circuler flexible 3 core 4 sqmm copper conductor cable.
Supply & fix in repairs blower/condenser fan motor complete with necessary mounting bracket to and base frames for Make as per exiting makes.
Water coolers of 40/80/120/150 ltr capacity.
Refrigerator of any type and capacity.
Supply & fix in repair Gun metal Globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed in pipe including taking out existing unserviceable globe or gate of valves.
15mm dia
20mm dia
Supply & fix in repairs push cock of brass chromium plated suitable for water cooler of any capacity including taking down existing cock
15mm dia
20mm dia
Supply & fix in repairs of water cooler inner tank made of stainless steel as per existing capacity (40/80 ltr) complete with drilling work with nuts and bolts complete.
Supply & fix in repairs of water cooler inner tank made of stainless steel as per existing capacity 60/120 ltr to 200 ltrs complete with drilling work with nuts and bolts complete.
Taking down/out desert cooler of any make and capacity from various locations, transporting to MES Store Yard and dismantling all unserviceable parts for repair/ overhauling/lubricating greasing and re-fixing the same back to its original position or in different locations as directed by Engineer-in-charge and making necessary connections with copper flexible cable 23/0.0076 Sqmm & commissioning & testing complete all as directed. Note- All major parts required for maint/ repair shall be measured and paid under relevant items mentioned as under. However, fixing charges of these items shall be deemed to be included in unit rate quoted for this item.
Supply only Wood wool pad 15mm thick made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire complete.
Supply only Cooler fan motor 230V with super enameled copper wire of existing size including testing.
Supply only Fan blades.
Supply only 3 pin plug top one way 5 Amp, 230V.
Supply only Water lifting pump 230 V, single phase, submersible type.
Supply only Front show grill as per existing/different sizes of desert cooler made of stainless steel.
Supply only Side grill as per existing/different sizes of desert cooler made of stainless steel for fixing wood wool pad including iron wire mesh complete all as specified and directed.
Supply only Flexible wire of 1.5 sqmm 3 core complete
Supply only Fan regulator suitable for any type any make of metal body desert cooler.
Supply only Four way distributor assembly along with 10 mm flexible PVC pipe of required length for one desert cooler.
M & L for painting of desert cooler of any capacity any type of steel/metal body with a coat of synthetic enamel paint of grey colour including prepartion of old painted steel surfaces and writing of MES No complete all as specified and directed by Engineer-in-charge.
M&L for replacement of desert cooler’s cabinet locally fabricated with three side panels front, top and tank including vertical mention made out 22 SWG PGI sheet of standard size with double diversion grills and grill box suitable for 450mm sweep fan and making holes with fixing arrangement incl 4 way PVC distributor, PVC pipe 3 to 4 Mtr for spray water, wood wool pads, electrical wiring, fan & pump set complete controlled separately with 5 amp Piano type switch and indicator etc complete all as specified.
Supply & fix in repairs of bottom water tank of water cooler made of MS CRC sheet 22 SWG PGI thick of as per existing size with rebated at corners nut, botls, joints sealed to make leak proof.
Taking down aluminium/copper point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, flourescent tube light fittings etc, removing materials to store for keeping in safe custody or for taking credit and making good to the disturbed surfaces of walls, ceilings and floors etc complete all as directed.
Taking down MCB distribution boards with incoming and outgoing controls any make and capacity after disconnecting of electric connections complete all as directed.
Taking down old unserviceable/burnt sub main wiring of any size including earth wire and making good to the disturbed surfaces and removing the material from site complete all as directed.
Supply and fixing switch socket combination 2 in 1, flush type 6 Amps.
Supply and fixing switch socket combination flush type 3 pin & 5 pin multipurpose 6 & 16 Amps.
Material and labour for submain wiring along with earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase-Red, Neutral-Black, Earth-Green) drawn in and including concealed rigid non metallic PVC conduit medium grade, ISI marked ivory colour alongwith accessorirs of following size:
2x4 Sqmm + 1x4Sqmm (earth) in 25 mm dia conduit. Note : Two runs of 4Sqmm one, One run of 4Sqmm earthwire & 25mm dia conduit shall be measured as one unit length.
2x6 Sqmm + 1x6 Sqmm (earth) in 25 mm dia conduit. Note : Two runs of 6Sqmm one, One run of 6Sqmm earthwire & 25mm dia conduit shall be measured as one unit length.
2x2.5 Sqmm + 1x2.5Sqmm (earth) in 25 mm dia conduit. Note : Two runs of 2.5Sqmm one, One run of 2.5Sqmm earthwire & 25mm dia conduit shall be measured as one unit length.
Supply & fixing powder coated CRCA steel sheet MCB distrbution board, IP-43 IK-09 protection, double door recess mounted for 240 volts, single pole and neutral 8 way with bus bar 200 Amp, type complete all as directed. Make :- Cat part No -507621 in Legrands or equivalent make given under list of makes.
Supply & fixing powder coated CRCA steel sheet MCB distrbution board, single door recess mounted for 240 volts, single pole and neutral 2 way complete all as directed.
Supply & fixing MCB Single pole 240 volts, C series of capacity 6 to 32 Amps of breaking capacity 10 KA including connections with copper lugs of suitable size in MCB DBs all as directed. Make :-Cat part No -408587 in Legrands or equivalent make given under list of makes.
Supply & fixing MCB Single pole and neutral 240 volts, C series of capacity 6-32 Amps of breaking capacity 10 KA including connections with copper lugs of suitable size in MCB DBs all as directed. Make :- Cat part No -408617 in Legrands or equivalent make given under list of makes.
Supply & fixing MCB triple pole and neutral 240 volts, C series of capacity 63 Amps of breaking capacity 10 KA including connections with copper lugs of suitable size in MCB DBs all as directed. Make :- Cat part No -408683 in Legrands or equivalent make given under list of makes.
Supply & fix in repairs of water heater storage type electric capacity 25 ltr, BEE 5 Star rated.
Supply & fix in repairs of water heater storage type electric capacity 3 ltr completed.
Supply and fixing rolled mild steel Joist, channel, angle or tee sections ( GDE Fe 290 ) as in framing for stand for Desert cooler, voltage stabilizer, ACs or for any other purpose with riveted bolted or welded attachment etc and inclusive of one primer coat , one under coat and one finishing coat of synthetic enamel paint including preparation of new steel surface complete all as specified and as directed.
Supply and fixing LT XLPE insulated heavy duty electric cables with aluminium condudctor, 1100 volts grade, 10 sqmm 2 core .
Supply and fixing LT XLPE insulated heavy duty electric cables with aluminium condudctor, 1100 volts grade, 16 sqmm 2 core .
Excavating in trenches n. exc 1.5m wide & n. exc 1.5mm depth for laying of cable and getting out in soft/loose soil complete.
Returning filling in including spreading, levelling, watering & well ramming in layer not exc 25cm complete all as specified.
Removing excavated material to distance n.exc 50m & depositing where directed at a level n.exc 1.5m above the starting point
M&L for sand cushioning to under ground cable in trenches in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. Note:- Measurement shall be taken after gentling puning of sand.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak, size 250 mm x 150mm x 40mm complete all as specified and directed.
Supply & fix in repairs 1/2''X1/4'' dia copper pipe including tubular heat/cold resistant rubber pipe / foam type insulation complete all as specified and directed. Note:- One run of 1/2''copper pipe, one run of 1/4'' dia copper pipe, one run of PVC pipe shall be measured as one unit length.
Supply & fix in repairs 5/8''X1/4'' dia tubular heat/cold resistant nitrile rubber pipe / foam type insulation complete for fixng from indoor to outdoor units of split AC all as specified and directed. Note:- One run of 5/8''internal dia , one run of 1/4'' internal dia shall be measured as one unit length.
Taking down unserviceable ceiling fans of any make and type and rectifying the defects including replacement of unserviceable parts and testing and reinstalling at same or any other location as directed at site by Engineer-in-charge. Notes: - (i). The unit rate is deemed to include the cost of taking down carefully fans from existing position after disconnecting electric connections, sealing cable ends, bringing to MES store yard and refixing in same as different locations after repair etc complete all as directed by Engineer-in-charge. (ii) Cost of major items such as ball bearing, gun metal bush, capacitors, canopy, blades and repair/ rewinding /painting etc shall be measured and paid separately under relevant item of this schedule as supply only. (iii) Minor items or works like tightening loose connections in switch, binding insulation tape to the naked wires, replacement of unserviceable clamps, nuts and bolts, split pins, rubber reel,greasing, washers, including flexible twin core copper wire of suitable size from existing ceiling rose to fan etc complete will be provided without any extra cost and cost of these minor items or works will be deemed to be included in the quoted rates against this item and nothing extra shall be paid on this account
Supply only capacitors 2.5 MFD suitable for all types of fans complete all as directed by Eng in Charge. Make: - Usha, Universal, Epcos.
Supply only capacitors 4.0 MFD suitable for all types of exhaust fans complete all as directed by Eng in Charge. Make: - Usha, Universal, Epcos.
Supply only ball bearing suitable for ceiling fan/exhaust fan/fresh air fan of any type as per existing required including proper alignment of shaft and testing complete all as directed by Eng in Charge.
Supply only bush made out of Gun metal suitable for ceiling fan/exhaust fan/fresh air fan as required at site all as directed by Eng in Charge.
Supply only shaft of approved quality as per existing for ceiling fan/ exhaust fan/fresh air fan any make complete as required at site all as directed by Engr in Charge.
Supply only canopy (set of two) suitable for ceiling fans of any make, type and size.
Supply only down rod MS grade 15 mm bore of length upto 90 cm suitable for ceiling fans of any type and size including cutting, drilling holes, making thread and painting complete all as directed.
Supply only ceiling fan blade of type and make as existing or as directed at site of 1200 mm sweep.
Supply only ceiling fan blade of type and make as existing or as directed at site of 1400 mm sweep sizes.
Taking down unserviceable exhaust fans of any make and type and rectifying the defects including replacement of unserviceable parts and testing and reinstalling at same or any other location as directed at site by Engineer-in-charge. Notes: - (i). The unit rate is deemed to include the cost of taking down carefully fans from existing position after disconnecting electric connections, sealing cable ends, bringing to MES store yard and refixing in same as different locations after repair etc complete all as directed by Engineer-in-charge. (ii) Cost of major items such as ball bearing, gun metal bush, capacitors, canopy, blades and repair/ rewinding /painting etc shall be measured and paid separately under relevant item of this schedule as supply only. (iii) Minor items or works like tightening loose connections in switch, binding insulation tape to the naked wires, replacement of unserviceable clamps, nuts and bolts, split pins, rubber reel,greasing, washers, including flexible twin core copper wire of suitable size from existing ceiling rose to fan etc complete will be provided without any extra cost and cost of these minor items or works will be deemed to be included in the quoted rates against this item and nothing extra shall be paid on this account
Supply only exhaust fan upto 300mm sweep blade of any type and make as existing or as directed at site all as directed by Engr in Charge.
Supply only exhaust fan upto 375/450mm sweep blade of any type and make as existing or as directed at site all as directed by Engr in Charge.
Supply only MS louvers with nuts, bolts and washers suitable to exhaust fan upto 350 mm sweep of any description/make/model complete all as specified and directed by Engr-in-Charge
Supply only MS louvers with nuts, bolts and washers suitable to exhaust fan upto 450 mm sweep of any description/make/model complete all as specified and directed by Engr-in-Charge
Supply only suitable frames of 300/375/450 mm sweep exhaust fan of any description/make/model complete all as specified and directed at site.
Material and labour for spray painting to ceiling fan (1200 mm/ 1400 mm) with one coat synthetic enamel paint by spraying machine including filling cavities with filler, after cleaning all dusts including writing of MES Nos in black paint all as directed by Engr-in-Charge.
Material and labour for spray painting to exhaust fan of any make, type and size with one coat of synthetic enamel paint by spraying machine including filling cavities with filler, after cleaning all dusts including writing of MES Nos in black paint all as directed by Engr-in-Charge.
Dismantling of worn out/burnt out windings of ceiling fan and re-winding the motor of ceiling fan with super enamelled copper wire of existing gauge, varnishing with approved quality insulating varnish complete including replacement of split/safety pins, locking nut, check nut and testing for original and consumption complete for following sizes:
1200 mm sweep.
1400 mm sweep.
Dismantling of worn out/burnt out windings of exhaust fan/fresh air any type and re-winding the motor with super enamelled copper wire of existing gauge, varnishing with approved quality insulating varnish complete and testing for original and consumption complete for following sizes:
150 mm sweep.
200/230/250 mm sweep.
300 mm sweep.
375 mm sweep.
450 mm sweep.
Supply and fixing in replacement of fresh air Fan with built in louvers of size 200mm, 230volt AC single phase 50Hz incl depositing the old one in MES store yard complete all as directed by Engr-in-Charge.
Supply and fixing in replacement of fresh air Fan with built in louvers of size 250mm, 230volt AC single phase 50Hz incl depositing the old one in MES store yard complete all as directed by Engr-in-Charge.
Supply and fixing in replacement of exhaust fan heavy duty metallic body AC 230Volt single phase including louvers and fixing accessories incl depositing the old one in MES store yard complete of following sizes :-
300 mm Sweep.
375 mm Sweep.
Supply and fixing in replacement of ceiling fan AC 230 Volt single phase five star rating and fixing accessories complete of 1200 mm sweep incl depositing the old one in MES store yard complete all as directed by Engr-in-Charge.
Supply and fixing in replacement of ceiling fan AC 230 Volt single phase five star rating and fixing accessories complete of 1400 mm sweep incl depositing the old one in MES store yard complete all as directed by Engr-in-Charge.
Supply and fixing in replacement of wall mounted fan AC 230Volt single phase five star rating and fixing accessories complete of 300 mm sweep incl depositing the old one in MES store yard complete all as specified and directed by Engr-in-Charge.
S&F in repairs fan regulator electronic step type as per existing type (switch or socket type) on the existing phenolic laminated sheet all as specified and directed by Engr-in-Charge.
Supply and fixing in repair step type electronic fan regulator (modular type as per exisiting 1M/2M) on the existing plate complete all as specified and directed by Engr-in-Charge.
M & L for Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed (FRLS) cable, multi-stranded, 1100 volts grade copper conductor, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) including with flush metal boxes with cover plates & frame for mounting switches, sockets, regulators etc or including sunk cast iron /pressed steel/terminal boxed for mounting flush type switches/sockets etc with 3 mm thick phenolic laminated sheet covers and including earth wire of PVC insulated (FRLS) copper conductor multistranded of 1.5 Sqmm size in green colour complete all as specified and directed by Engr-in-Charge.
One light point or one fan point or one bell point controlled by 1 way switch/ push button all as specified and as directed
One 3/5 pin switch-socket outlet, 5 Amps on same board all as specified and as directed
One 3/5 pin switch-socket outlet, 5 Amps on independent board all as specified and as directed
All as per item No 92 here-in-above but for one 15 Amp 3 pin switch socket outlet, independent, with 2.5 sq mm single core multi-stranded copper conductor along with 2.5 sq mm continuous PVC insulated unsheathed solid copper conductor cable for earth continuity wire, all as specified .
Supply and fixing switch piano fiush button, single pole one way 5 amps.
Supply and fixing socket out let 2 in 1 flush type 5 pin 5 Amp complete all as specified.
Supply and Fixing ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified.
Supply & fixing in replacement indoor decorative ultra slim surface/wall mounted T5 LED batten tube light with 1x24 watt tube light fitting complete fitting with polycarbonate channel housing & integrated electronic driver, energy efficient, 14V-270 volts complete with all accessories internally/pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete.
Supply & fix surface mounted bulk head LED light fitting including 10 watt LED lamp B22 base complete with all accessories and connection complete all as specified and as directed.
Supply & fix in repair recess type, 36 watt LED panel light (600x600 mm) complete with fittings integrated electronic driver,energy efficient, 230 volts,co- related colour temperature (CCT) of 6500K, warm white/ cool white/natural white complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge.
S&F of 30W LED building security light fitting with lens & driver, powder coated pressure die cast aluminium, top opening and maintainable with heat resistance toughened glass, built-in Short-Circuit Protection, Over voltage Protection and Surge Protection, IP-65 proction with luminaire efficiecy of greater than 80Lumen/Watt, Colour rendering (CRI) of ≥ 70 and co- related colour temperature (CCT) of 5700K (±500K) . The luminaire should have 10 KV surg protection, PF ≥ 0.9 and total harmonic distortion of THD ≤ 10%, voltage range of 140-280V including all connections complete all as specified.
S&F MCB distribution board, SPN 8 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified.
S&F MCB distribution board, SPN 4 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified.
Supply & fixing in replacement of MCB SP 6 - 32 Amps, ' C' series, breaking cap 10KA, 240V complete all as specified and directed.
Supply & fix in replacement of MCB SPN 6-32 Amps,' C' series, breaking cap 10KA, 240V complete all as specified and directed.
Supply, installing, commissioning and testing, hi split type air conditioner of nominal capacity 1.5 TR, inverter type compressor, remote operated suitable for working on 230 volts, single phase, 50 HZ supply and 5 star energy rated complete including cutting/ drilling of wall, providing stand for outdoor unit and making good disturbed surface of wall etc complete all as specified and directed by Engineer in charge. Make:- Cat part No JTK50TV16U of Daikin or equivalent in Carrier/ Hitachi/Blue star
Note:- Rate are included in quoted by contractor for following items are as under:- (a) fixing the cooling unit with grouting nuts, cutting groove to wall for gas pipe & water drainage pipe (b) S &F PVC Pipe 15/20 mm dia transparent flexible heavy duty for water drainage pipe of required length at site. (c ) Insulation of both the copper pipes with insulating material and covering the complete pipe with PVC casing & capping of size 75x75 mm/ reqd size of mechanical protection of copper pipe complete. (d) charging of correct qty of refrigerant gas after necessary brazing/fixing of both the outdoor/indoor unit and testing complete on load to obtain 18 degree Celsius temperature at specified amps. (e) Length of copper tubing as per site requirement shall be supply and fix by contractor. (f) All other connected civil work & other misc work reqd for installation of split AC for proper functioning as directed by EIC.
Ms Kamal Kant Agarwal
ISHWAR ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .