| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹12.6 L+₹42,800 (3.51%)Rejected-Finance COLABA MUMBAI | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹12.7 L+₹54,750 (4.49%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L3 | Rejected-Finance Other than being lowest | |
| 4 | L4₹12.9 L+₹70,450 (5.78%)Rejected-Finance COLABA MUMBAI | L4 | Rejected-Finance Other than being lowest | |
| 5 | L5₹13.3 L+₹1.1 L (8.73%)Rejected-Finance COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | L5 | Rejected-Finance Other than being lowest |
Tender Value
₹11.6 L
EMD Value
₹23,200
Closing Date
2 Nov 2021, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR ROUTINE MAINT OF 04 NOS ELECTRIC LIFTS ( MAKE JOHNSON) OF G 13 STOREY BUILDING AT NAVY NAGAR COLABA MUMBAI UNDER GE(NW) NAVY NAGAR COLABA MUMBAI (3 RD CALL)
2021_MES_466225_3
8241/CWE(NW)MUMBAI/E8
Open Tender
Electrical and Maintenance Works
Item Rate
360 days
GE (NW) Navy Nagar
Class E
8 documents required · 8 mandatory
₹500
Yes
GE (NW) Navy Nagar
₹23,200
Yes
26 Nov 2021
14 Oct 2021
4 Nov 2021
14 Oct 2021
2 Nov 2021
21 Oct 2021
14 Oct 2021 - 20 Oct 2021
Amount
Repair/maintenacne of lifts including carrying out daily check and periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes,door cards,car door sills, landing door sills, door locks, control cards, and its contacts, hall push buttons and its spares, connector/links, welding of crack/broken and MS parts, Landing operating Panel of any size and capacity, repairs /maint of u/s damaged door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator, and all connected accessories, necessary wiring of hall push button assembly, repair/maintenance of broken COP/LOP buttons and display, including cover, Fire alarm, Firemen button glass, Intercom, alarm/hooters, Maintenance of damaged hand rail, Shaft, light/switches, complete with illuminated push button and direction indicator with LED display with LPT/LPC card of stainless steel inclusive of harness wiring for laminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement for safe operation of lifts ,
fixing of loose rail bracket with necessary masonry work ,cabin, minor repair of cabin light and minor repair of cabin fan , ensure safe and smooth functioning of lift and complete maint of car top, binding of loose wire at control panel and rust painting at car top and door and allied parts with testing, two coats of Painting of Gear motor, Traction motor and all mechanical parts which required painting all MS channels and Control panels using spray gun complete, dewatering of lift wells in case of any emergency arise all as directed by Engineer-in-Charge. for the following lifts :-
8 Ps Lift (554 Kg)capacity in R-40 bldg (G+13 Storey)(Total 02 No of Lifts)
13 Ps Lift (884 Kg)capacity in R-40 bldg (G+ 13 Storey) (Total 02 No of Lifts)
Note : - (i) The Contractor has to carry out the AMC of the Lifts through OEM only (ii) The AMC should cover any/all parts of Lifts if its fucntions found defective the same should be repaired or replaced by the OEM as per the timeline covered under norms. (iii) Two mechanic shall be available round the clock at lift complaint cell for safe & smooth functioning of the lift. (iv) Rewinding of motor if required will be done by the contractor and no extra cost will be given by the department. (v) The detailed lift mechanics of the firm shall report to the JE Concerned at the Lift complaint cell for receiving the complaints at round the clock daily including sunday and holiday. (vi) The detailed lift mechanics shall sign ( Their shift wise) in the attendence register kept with lift cell. (vii) Cost of minor spare parts / routine material required for above mentioned maintenance is deemed to be included in the quoted rate except items mentioned here-in-after. No additional cost of spares is admissible for the above maintenance. Decision of the Accepting Officer shall be final & binding regarding minor spares/ routine material
(viii) Monthly schedule for proper maintenance of lift and necessary documentation including all spare parts required to be replaced during the period shall be as directed by Engineer-in-Charge. (ix) All minor spare parts and parts required for repair / replacement for maintenance of lifts to be replaced during AMC at no extra payment. (x) Bidders are to submit license from Govt. of maharashtra for maintenace & erection of lifts issued by chief electrical inspector.
Part-II Disconnecting and taking out unserviceable COP assembly for G+5/G+14 storey building, supply and fix new car operating panel assembly completed with illuminated push button for floor position alarm, non stop door open , door close, cabin fan, cabin light stop, attend out key etc with direction indicator,with LED displey with CPI card of stainless steel face plate in and including necessary wiring for laminating push button of each floors and cutting wall, making good disturbed surface with machinary work to complete all as specified and directed by Engineer-in-charge.
Taking down old unserviceable cabin fan from car cabin and supply and fixing new cabin fan non oscilating type axial flow, single speed 300mm sweep, 240 volts ISI mark with grill complete all as directed by Engineer-in-charge. Make :- EMCO /VBM /CINI.
Replacement of automatic door drive unit with motor on car top with VVVF of 1 HP capaicity all as specified and directed by Engineer-in-Charge. Make : Yasakara / Sneider as approved by Engineer- in - Charge.
Dismantling and taking out unserviceable safety edge of any type supply and fixing full beam infrared sensor upto full length of car doors (2.00 mtr) complete all as specified and directed by the Engineer-in-Charge. Make : WECO)
Supply and fix in repair Emergency alarm with complete accessories including rechargeable batteries alongwith box including connecting cables for G+5/G+14 storey building all as specified and directed by Engr-in-Charge.
Taking down old unserviceable main steel wire rope after disconnecting old wire rope from counter weight, pulley and car cabin and supply and fix new main steel wire rope 13 mm dia, ungalvanised, 8/19 construction in and including necessary connection with counter weight, pulley and car cabin with clamps, nut, bolts and washers etc complete all as directed by Engineer-in-Charge.in 8/13 /Goods Lift, G+5/G+6/G+14 Storey buildings.Make : USHA MARTIN
Disconnecting and taking out old/unserviceable travelling cable from hoist way and supply and fix new travelling cable PVC Insulated 16/24 Core with stranded copper conductor, 1100 volts grade of size 0.75 Sqmm conforming to relevant IS including criping with lugs appropriate thimples complete all as specified and directed by Engineer-in-Charge.Make:- Polycab/Finolex
Disconnecting and taking out defective unserviceable main drive (any type) from existing control panel and supply and fixing new main drive VVVF drive suitable for 13 Ps lift G+14 storey building complete with all electric connection. Make : ESCON. Location :- R- 40 Bldg.
Disconnecting and taking out old/unserviceable Governer rope of size 8 mm dia(8/19 Construction) ungalvanised including necessery connection with pully in machine room and shaft pit complete with clamps, nuts bolts, and washers etc, for high rise building for 8/13 Ps lifts
Veer High Tech Solution
shakti engineering and electrical works
Monarch Enterprises
Escon Elevators Pvt Ltd
PHOENIX ELEVATOR INDIA PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .