Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-Finance BIRBHUM SANTINIKETAN | SANTINIKETAN | BIRBHUM | WEST BENGAL | L1 | Accepted-Finance ACCEPTED | |
| 2 | L2₹8.7 L+₹2,728.03 (0.31%)Rejected-Finance 9 ANATH BANDHU MUKHERJEE LANE SERAMPORE HOOGHLY 712201 | SERAMPORE | HOOGHLY | WEST BENGAL | 712201 | L2 | Rejected-Finance REJECTED | |
| 3 | L3₹8.8 L+₹4,980.53 (0.57%)Rejected-Finance 26A MAHARAJA TAGORE ROAD KOLKATA 700031 | KOLKATA | KOLKATA | WEST BENGAL | 700031 | L3 | Rejected-Finance REJECTED |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
2 Jun 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER BOLPUR MECHANICAL DIVISION PHED
SRINIKETAN ROAD NEAR HOTEL MARK MEADOWS PO SRINIKETAN DIST BIRBHUM PIN 731236
Providing and Installation of Submersible pumping Machineries at newly sunk Tube Well and allieds works at at ATKULIA Piped Water Supply Scheme (TW No-I, II and III ) within Block-NALHATI-II under Bolpur Mechanical Division.
2025_PHED_837141_10
PHED/05/EE/BOLMD/2025-26
Open Tender
MECHANICAL
Item Rate
30 days
ATKULIA BIRBHUM
Please refer Tender documents.
5 documents required · 5 mandatory
₹18,000
7 Jul 2026
21 Apr 2025
4 Jun 2025
22 Apr 2025
2 Jun 2025
22 Apr 2025
Amount
Supply and delivery at site of following vertical submersible pumping machinery directly coupled with wet winding type suitable size submersible motor with following specification: Shaft-S.S, Impeller- S.S / NYROL / Crome Steel / GM, Outlet - 50/65/80/100 mm dia . Motor : Operating Voltage : 415 V (± 10 %), Phase : 3ph, 50 Hz ± 6% Speed : 2900 RPM, Method of starting : Υ/Δ Discharge (Q) : 20mᶟ/Hr. Head (H) : 66mtrs. (Make : KSB / Grundfos / Texmo / CRI / KBL / MBH / or any approved vendor.) ( N.B : Manufacturer's test certificate along with charecteristics curve and gurantee certyificate have to be submitted at the time of delivery.)
Supply delivery at site of 4sqmm 3 core 1.1 KV Grade flat submersible copper conductor cable . (Make:- Finolex / Gloster / Polycab / Mescab / or any Approved Vendor list of PHED.)
Supply & delivery of 63 Amps re-wireable porcelain fuse unit type TPN Main Switch with steel sheet enclosure (Conforms: IS/IEC600947-1&3). (Make: Approved Vendor list of PHED.)
Supply and delivery of the following valves, pipes and gauges etc at site-- (Make: Approved Vendor list of PHED.)
3mtr long 80mm dia UPVC standard type column pipe [cream color] with both side threaded and one end side socketed with registered KPMG.
1.5 mtr long 80mm dia UPVC standard type column pipe [cream color] with both side threaded and one end side socketed with registered KPMG.
80mm dia. CI Top & Bottom adopter.
Heavy type suitable dia. MS suspension clamp along with nuts bolts and washers.
80mm dia. CIDF Non-Raising Sluice Valves, PN 1.0 rating (Conforming to IS:14846) for wash out line. (MOC & TC needed for valve).
80mm dia. CIDF single door swing Non Return Valve, PN 1.0 rating (Conforming to IS:5312) (MOC & TC needed for valve).
CIDF 90°bend- 1no., CI flanged tee- 1no., blank flange-1no., CI/ MS flanged short piece 0.50 mtr.-1no, CI/ MS flanged pipe 1mtr.- 1 no. etc (as per IS specification and certification registered) for construction of delivery pipe line and wash out line.
Heavy type 250mm dia./suitable Split type tube well cover with clamping arrangement including supply of nuts, bolts and washer as per departmental design.
Supply & delivery of Three Phase Submersible Pump Controllers (with Single Phase Preventer) for Submersible Pump with Realy Range (13-21)A. Coil voltage - 415V, [Model - MU-G10 DOL, (With Wideband Coil)], (Make-L&T/PHE dte approved make)
Anti snapping safety device for pump set by supplying suitable size of MS angle busket and nylon rope of required length including supplying of nuts, bolts and all other materials.
Making brick pillar 0.25 x 0.25 x 0.75 Mtr/Suitable hight for supporting of valves and pipes with 12mm thick plaster and net cement finish complete. (Both Pipe line)
Installation of Submersible pumping machinery to newly sunk tubewell along with column pipes (as required), top cover, valves, and specials of above with protection pipe and supply of MS clamp, nut bolt, cable gland socket etc. making inerconnection of the pump delivery line to pump collecting main line near tubewell with supply of all necceasary pipe, reducer/enlarger, GI/MS specials etc. including brick, sand, cement, rod etc and laying & drawing of all power cable properly on on wall / tray for layout & IE rules, installation of pump controllers, main switch etc. as required and all to complete the job including all connection, socktings & testing commissioning as per direction of EIC. [N.B: (1) Pump data is to be confirmed with the yeild test report of the tube well. (2) Third party inspection of the work is mandatory as per guidelines of NJJM and direction of EIC without any extra cost. (3) Drawing, design and make of the materials are to be approved from the EIC before procurement.]
Add: GST @ 18% on sum of Item No: 1.00 to 16.00
Add: Cess @1% on sum of Item No. 1.00 to 17.00
A. S. ENTERPRISE (BID ID -6494415)
DITHI ENTERPRISE (BID ID -6494427)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
cancelled_1.pdf
pdf • 0.07 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .