Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
₹8.0 L
EMD Value
₹15,970
Closing Date
23 Sept 2023, 6:00 pmClosed
Executive Engineer(C),
BSNL Civil Division MM Nagar No.65, Ganganagar 3rd cross, Kodambakkam, Chennai- 600 024
Structural repair work and external painting to Chrompet Telephone Exchange building, Chennai.
2023_BSNL_167289_1
NIT No 09/BSNL/CD-MMN/CH/2023-24
Open Tender
Civil Works - Others
Item Rate
90 days
Chrompet
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
AO(Cash), BSNL Chennai Telephones
₹15,970
25 Sept 2023
12 Sept 2023
25 Sept 2023
12 Sept 2023
23 Sept 2023
12 Sept 2023
12 Sept 2023 - 23 Sept 2023
Amount
Felling tree branches,climbers, bushes,small plants spread,grown up, projected over the terrace surface and building walls and destroying the roots using required acid/ chemicals and disposal of same all complete.
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge
25 mm average thickness
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge
Bars upto 12 mm diameter
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.
SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer.
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge.
12 mm average thickness
25 mm average thickness in 2 layers.
Providing, mixing and applying SBR polymer (of approved make @ minimum 2% by wt. of cement used) modified plain/reinforced cement concrete for structural members having minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness.
50mm thick in Grade M 25 with cement content not less than 330 kg per cum
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead :
With cement mortar 1:4 (1 cement : 4 fine sand).
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
40 mm thick with 20 mm nominal size stone aggregate
Providing and fixing double scaffolding upto Four storey height made with casurina posts of dia upto 100mm dia 1.50m centre to centre ( both horicontal and vertical casurina posts of dia upto 100mm dia ) joining with rope,nails etc.and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system should be provided with essential safety feautures of the workmen etc.complete all as directed by the Engineer-in-charge.(The elevational area shall be measured for payment.)
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Applying priming coat :
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works
Painting with Synthetic enamel paint of approved brand and manufacture of required colour to give an even shade. Two or more coats on old work.
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .