| 1 | L1₹38.5 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹46.7 L+₹5.1 L (12.2%)Rejected-Finance BYE PASS DALHOUSIE ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹48.6 L+₹6.9 L (16.7%)Rejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹48.8 L+₹7.2 L (17.2%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
31 Dec 2024, 6:00 pmClosed
GE Gurdaspur
Garrison Engineer, Gurdaspur (Tibri)
Repair/ replacement of sewage distribution and connected system incl pipe line, panels, valve etc and repair/ maint of lightening conductor works, high mast system, security light, garden light and allied works at Tibri Mil Stn under GE Gurdaspur.
2024_MES_686923_1
GE GSR-70/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE Gurdaspur
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹98,000
15 Jan 2025
4 Dec 2024
7 Jan 2025
4 Dec 2024
31 Dec 2024
19 Dec 2024
Amount
M & L for dismantling/taking down carefully by disconnecting of electric connection from pole/ walls of any heights and any situation/loction,place Street light fittings type of Tube Rod 36/40 watts,HPSV,HPMV, U/S LED Streedt lights any wattage of flood lights,post top lanterns etc. complete all as specified and directed by Engineer-in-Charge.
Supply & fixing LED Street light 90 Watt WARM WHITE 3000K with silicon gasket for IP 66 (no glue) protection suitable upto 50mm OD holder fixed on existing poles. LED street light shall be made up of pressure die cast alluminium LM 6 aloy housing with toughend glass and high power LEDs and secondary lenses with IP 66 protections ( LED viz; Havells,Wipro, Philips), top opening for separate driver compartment with frame, brand, logo embossed, toughened glass cover. High power ceramic base, CRI > 70,and bolted inside the luminaire panel. Average life class of 50000 hrs metal body fully coated phase to phase protection at 440 V upto 4 hours and > 300 V auto cut and restart feature. Luminaries and driver shall be of same make to avoid any dispute and service issue later, Lights are connecting up with twin core flexible copper conductor cable all as directed and specified The Make of : Havells,Wipro, Philips
All as per Srl item No 2.00 above but capacity 72 Watt all as directed by Engineer-in-Charge. Make : Havells,Wipro, Philips.
All as per Srl item No 2.00 above but capacity 60 Watt all as directed by Engineer-in-Charge. Make : Havells,Wipro, Philips.
Supply and fixing energy saving LED INVERTER TYPE STREET LIGHT 45 WATT AND BATTERY BACK UP OF MINIMUM 2 HOURS environmental friendly, long life , exclusive innovative die-cast aluminium IP 66 security light with high power LEDs as light source , Suitable for 40 mm GI pipe, 5700K LED of Havells of and ,connecting up with twin core twisted flexible copper conductor cable all as directed.
All as per Srl item No 5.00 above but capacity 60 Watt all as directed by Engineer-in-Charge
Supply and fixing in replacement of Unsv driver for LED street of capacity 90 to 120 Watt for any make and type all as specified and directed by Engineer-in-charge.
All as per Srl item No 7.00 above but 30 to 72 watt all as specified and directed by Engineer-in-charge.
Supply and fix in repair of Unsv Driver for LED inverter type capacity 45 Watt capacity with Lithium battery backup min 2 hours all as specified and dirrected.
All as per Srl item No 9.00 above but capacity 60 watt all as specified and directed.
Supply and fixing in replacement GI pipe bracket made out of GI pipe light grade 32 mm dia and bend to shape 1.5 mtr long, including MS clamps made out out of MS flat iron of size 40X4mm thick with nuts&bolts,washers complete including dismantling the existing GI pipe bracket and drilling of holes for nuts & bolts etc all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of single phase 5 KW Automatic street light control switch using Infrared Sensor based NATURE SWITCH for automatic switching of street lights. Nature switch operation should be based on Natural Light Lux level. Switching off illuminance level should be of minimum 30 Lux and Switching off illuminance should be greater than or equal to 10 LUX. The sensor should also have part night operation facility of min 4 hrs to maximum 12 hrs. The circuit shall have a provision for manual over ride operation. The sensor along with suitable power contactors and incoming outgoing MCBs should be enclosed in a pole/wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR grade with Hensel Enclosures, conforming to IP66 complete all as directed by Engr-in-charge. Make of Nature swithc Kaatiya Energy Systems/ Havells/Healer Enterprises. Contactor : BCH/L&T/Schneider, MCBs: Hager/Schneider/L&T/C&S, SMC enclosure and circuit sheet " Hensel.
M & L for painting the PCC pole of 05 Nos bands/ strips of 30cm wide each with two coats of synthetic enamel paint (black and yellow) at a distance of 30cm from the plinth block upto 1500mm height and marking / sign writing of pole number and feeders locations of pole with thick synthetic enamel paint (white) including all MS fitting street light brackets MS flate angle iron GI pipe etc complete all as specified and directed to match the existing poles.
Supply and fixing LED flood light 200 watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp in replaceemnt metal halide flood light hoarding light luminaire complete all accessories, connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed by Engr-in-Charge. Make of : Havells,Wipro, Philips
All as per Srl item No 14.00 above but 120 watt all as directed by Engineer-in-Charge.
Supply and fixing in replacement of 3 pole power contactor of amp rating 25 to 45 Amps as per existing make and rating all as directed by Engineer in charge.
Supply and fixing of LED post top lantern with die cast housing cum heat sink with PMMA diffuser in IP-66 fitting of 30 Watt all as directed by Engineer in charge. Make : Havells,Wipro, Philips.
Supply and fixing Bollard LED light cap 16 Watt all as specified and directed. Make : Havells,Wipro, Philips.
Supply and fix Alluminium lugs eye type suitable for cable size 6 sq mm to 10 including necessary crimping with crimping tool complete all as specified and directed .
All as per Srl item No 19.00 above but of size 16 sqmm to 35 sq mm.
Supply & fix LT straight through Cable joining kit heat shrinkabale complete with jointing materials suitable for LT Armoured cable 2/4 core of size 16 sqmm to 35 Sqmm all as directed.
Supply & fix LT straight through Cable joining kit heat shrinkabale complete with jointing materials suitable for LT Armoured cable 3.5/4 core of size sqmm 50 to 70 sq mm all as directed.
S & F in replacement of junction box Size 200X140X95mmpoly corbonate with glass fibre reinforced , environment friendly, recylable, UV resistant , halogen and silicon free anti acid and anti corrosive IP 66/67 in accordance with IE rule internally embedded gasket, junction box including 3 phase 415 volt aluminium bus bar and Din rail for fixing the MCB including one No. MCB SP 6A 10KA to control the street light including necessary clamps, nuts bolts to fix the junction box with poles all specified and directed.
M & L for preparation of old painted surfaces of electric pole removing complete dust and other deposited materials by cleaning from steel tubular pole of length upto 9 to 12 metres cross arms, bracing, clamps etc and painting with one coat of aluminium paint, retaining and repainting existing marking on pole and replacement of reflective band of 3M brand RED-YELLOW-RED alternate coloured 3 numbers of minimum 5 cm in height wrapped all around the pole all as specified and directed by Engineer in Charge.
S &F and commessioning of LT outdoor total enclosed/ Lt panel board size 0.75x0.50x0.30 meter approx tottaly enclosed made out of 3 mm thick CRCA sheet, dust and vermin proof with front opening 440V, 3 phase, 4 wire having 200 Amps capacity aluminium bus bar insulated with sleeves, incoming MCCB TPN 63 Amps 440 Volt 16 KA -01 No and copper wiring with multistranded cable including timer switch electronic type 01 No with necessary MCBs 6 Amps 09 Nos, contactor and stater to operate the motor for hosting and lowering the light to carry the repair, lugs and pedastal 300 mm grouting and 450 mm above the ground. Grouting the panel. (b) Provision of wiring from panel to light fitting with 2 Core 4 SQMM copper conductor cable drawn through M rigid/flexible conduit with necessary fitting etc.
Supply and fixing Weather proof flat twin core cable aluminium conductor of size 2.5 sqmm 2 core all as specified and directed by Engineer-in-Charge.
Supply and laying Weather proof flat twin core cable aluminium conductor 1100 volts grade size 10 Sqmm including taking out old one all as specified and directed.
Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out all as specified.
Returning, filling in, including spreading, leveling,watering and well ramming in layers each n.exc 25 cm thick in soft loose soil all as specified.
Removal of excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply and lay brick common burnt sub class "B" old size (compressive strength not less than 75 kg per sqcm) for protection of cable laid in trenches for under ground cable all as specified.
M & L for Sand cushioning trenches using fine sand to under ground cable, laid in two layers 15cm before laying the cable & 8cm after laying the cable complete all as specified and directed.
Supply and laying in replacement XLPE insulated armoured (under ground) heavy duty electic cablewith stranded aluminim conductor 1100 volts grade of crossectional area 16 Sqmm 4 core laid in trenches/ducts/through pipes/in floor road/along the pole etc all as specified & directed by Engr-in-charge. Make( Havells,KEI Industries, Rallison) Note : Contractor provide 01 year warranty of the Cable after completion of the work. Within one year found any fault of the cable contractor shall be replaced/rectify the same on own cost.
All as per Srl item No 33.00 above but of size 25 sqmm 4 core.
All as per Srl item No 33.00 above but size 35 sq mm 3.5 core.
Supply and fixing in replacement of cable protection GI tubing light grade fixed long the pole/under road/along the wall of size 50 mm bore with necessary clamps all as directed.
Supply and erecting in steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as pecified type 410 SP-55 (11.0 metres long) including dismantling existing pole complete all as specified and directed.
Providing PCC 1:4:8 type D:2 using 40mm graded crushed stone aggreate as in foundation for pole/stay assembly foundation etc all as specified and directed by Engineer-in-Charge.
Providing PCC 1:3:6 type D:2 using 40mm graded crushed stone aggreate as in foundation for pole/stay assembly etc all as specified and directed by Engineer-in-Charge.
Providing PCC 1:2:4 type B:2 using 40mm graded crushed stone aggreate as in coping of pole including necessary form work and fair finish to exposed surfaces complete all as specified and directed.
Supply and fix Replacement of aluminium strip 25 x 3.15 mm with saddles and fixing screws, insulators rawal plugs etc for conductor for roof and fixed on wall upto test point all as specified.
Supply and fix Replacement of galvanized iron strip 32 x 6mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground / drawn into hume pipe. NOTE : Excavation & earth work shall be measured and paid for seperately under relevant item of schedule.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
Supply and Fixing in replacement CI pipe of 200 mm ISI marked with flanged ends socket ends with push on rubber gasket joint etc all as directed
Supply and fixing in replacement CI pipe of 150 mm ISI marked with flanged ends socket ends with push on rubber gasket joint etc all as directed.
Supply and Fixing ductile iron centrifugally cast (span) pressure pipe class K-9 size 100 mm ISI marked with internal cement mortar lining and external zinc and bitumen coated pipe 100mm bore with all spogot and socket ends with push on rubber gasket joint etc all as directed.
All as per item Srl item No 46.00 above but size 150 mm bore.
Material and labour for CI specials such as Tees of any size and radious, collars, tapers, tail pieces, caps and plugs upto 200 mm bore.
A Schedule of Credit for old/unserviceable demolished/ dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit.
M/S GULATI ENGINEERING WORKS (BID ID -3203089)
HARPAL ENGINEERS AND BUILDERS (BID ID -3202754)
P S BUILDERS (BID ID -3202546)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .