Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC NOT AVAILABLE | L1 | Accepted-AOC Being Lowest Tenderer | |
| 2 | L2₹46.3 L+₹4.9 L (11.9%)Rejected-Finance FLAT NO 002 MAHAVIR VILLA CHS LTD PLOT NO 259 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance Being Other than Lowest Tenderer | |
| 3 | L3₹1.0 Cr+₹63.5 L (153.3%)Rejected-Finance | L3 | Rejected-Finance Being Other than Lowest Tenderer |
| Sl No | Description | Qty | Unit | RAJENDRA CONSTRUCTION L2 | D S MADANE ENGINEERS AND CONTRACTORS L3 | SHREE JAGDISH FURNITURE CO. L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster of any description on brick, stone or concrete surfaces of walls including raking out joints, hacking for key, scrubbing down with water upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed. | 1,500 | Sqm | 100 ₹1,50,000 | 300 ₹4,50,000 | 47 ₹70,500 Lowest |
| 2.00 | M&L for Rendering 15mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement. Upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed. | 500 | Sqm | 301 ₹1,50,500 Lowest | 800 ₹4,00,000 | 365 ₹1,82,500 |
| 3.00 | M&L Plastering 5mm thick in CM 1:3 on concete surfaces as in ceiling finished even & smooth without using extra cement in ceiling. Upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed. | 100 | Sqm | 501 ₹50,100 | 750 ₹75,000 | 326 ₹32,600 Lowest |
| 4.00 | M&L for 10mm thick plaster on fair faces of brick work or concrete surfaces in cement mortar 1:3 in ceilings, to be finished even and smooth without using extra cement .Upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed. | 900 | Sqm | 555 ₹4,99,500 | 800 ₹7,20,000 | 326 ₹2,93,400 Lowest |
| 5.00 | M&L preparation of new plastered surface of ceiling and applying two coat of oil bound distemper on ceiling with alkali resistant primer .Upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed. | 1,000 | Sqm | 50 ₹50,000 Lowest | 500 ₹5,00,000 | 78 ₹78,000 |
| 6.00 | M & L for preparing new plastered surfaces of walls and applying two coats of oil bound distemper with priming plastered and other surfaces with alkali resistant primer with 3mm thk wall care putty on plastered surfaces. Upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed. | 500 | Sqm | 50 ₹25,000 Lowest | 550 ₹2,75,000 | 101 ₹50,500 |
| 7.00 | M&L for complete removal of existing treatment of old plastered surfaces on walls/ceilling including brooming down or steel wire brushing, scraping down and applying two coats of distemper oil emulsion over one coat of alkalic resistent primer complete.Upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed. | 2,155 | Sqm | 51 ₹1,09,905 Lowest | 450 ₹9,69,750 | 81 ₹1,74,555 |
| 8.00 | Material and labour for providing and applying approved epoxy resin EPI Bond of Krishna conchem or equivalent before polymer plaster/ Concrete to have the perfect bond between old concrete and new concrete/ polymer plaster surface confirming to ASTM-C-882-87 using nylon brushes Upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed . Make: Fosroc/ Sika/ Dr.fixit or as approved by GE | 1,400 | Sqm | 151 ₹2,11,400 Lowest | 650 ₹9,10,000 | 247 ₹3,45,800 |
| 9.00 | Material and labour for providing and applying priming cum bonding coat of polymer of approved make and quantity as approved by engineer-in-charge and cement slurry in 1:1 proportionate by weight to concrete area by brush or any other established method etc. Upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed . Make: Fosroc, Sika, Dr fixit or as approved by GE | 1,400 | Sqm | 151 ₹2,11,400 Lowest | 450 ₹6,30,000 | 222 ₹3,10,800 |
| 10.00 | Removing building material/debris exc. 5 km but n exc 25 km and depositing where directed complete all as specified and directed . . | 2 | Per load | 10,001 ₹20,002 Lowest | 20,000 ₹40,000 | 14,000 ₹28,000 |
Tender Value
₹48.2 L
EMD Value
₹96,380
Closing Date
4 Nov 2025, 6:55 pmClosed
LT COL ANIL KUMAR S
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8153 ADDITIONAL ALTERATION AND SPECIAL REPAIR OF GROUND FLOOR CEILING OF CENTER NO 45 OF EPS DEPT BUILDING NO 192 AT NAVAL DOCKYARD PROVISION OF AC AT ACC-1
2025_MES_736212_1
8153/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹96,380
Yes
18 Dec 2025
21 Oct 2025
6 Nov 2025
25 Oct 2025
4 Nov 2025
28 Oct 2025
21 Oct 2025 - 25 Oct 2025
Amount
Taking down cement plaster of any description on brick, stone or concrete surfaces of walls including raking out joints, hacking for key, scrubbing down with water upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed.
M&L for Rendering 15mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement. Upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed.
M&L Plastering 5mm thick in CM 1:3 on concete surfaces as in ceiling finished even & smooth without using extra cement in ceiling. Upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed.
M&L for 10mm thick plaster on fair faces of brick work or concrete surfaces in cement mortar 1:3 in ceilings, to be finished even and smooth without using extra cement .Upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed.
M&L preparation of new plastered surface of ceiling and applying two coat of oil bound distemper on ceiling with alkali resistant primer .Upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed.
M & L for preparing new plastered surfaces of walls and applying two coats of oil bound distemper with priming plastered and other surfaces with alkali resistant primer with 3mm thk wall care putty on plastered surfaces. Upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed.
M&L for complete removal of existing treatment of old plastered surfaces on walls/ceilling including brooming down or steel wire brushing, scraping down and applying two coats of distemper oil emulsion over one coat of alkalic resistent primer complete.Upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed.
Material and labour for providing and applying approved epoxy resin EPI Bond of Krishna conchem or equivalent before polymer plaster/ Concrete to have the perfect bond between old concrete and new concrete/ polymer plaster surface confirming to ASTM-C-882-87 using nylon brushes Upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed . Make: Fosroc/ Sika/ Dr.fixit or as approved by GE
Material and labour for providing and applying priming cum bonding coat of polymer of approved make and quantity as approved by engineer-in-charge and cement slurry in 1:1 proportionate by weight to concrete area by brush or any other established method etc. Upto 8 to 10mtr height of Ground floor of bldg incl scaffolding complete all as specified and directed . Make: Fosroc, Sika, Dr fixit or as approved by GE
Removing building material/debris exc. 5 km but n exc 25 km and depositing where directed complete all as specified and directed . .
S&F for aluminium deco grill 7.5mm size DG 102,fixed to F/H frames. 1.5mm thick bar size 6.2mm and 7.5mm thick in required size complete all as specified and as directed. Note: (i) Necessary scaffolding for high rise bldgs upto G+4 floor is included & complete all as specified and as directed. (ii) Outside area of bldgs covering with plastic/ tarpaulin (iii) All the safety precautions adopted by the contractor at the side (iv) All the passes will be submitted by the contractor after completion of the work. (v) The quoted rate shall be deemed to be inclusive of the above. (vi) If the contractor fails to follow the above conditions , charges will be levied as decided by the Engg in Charge.
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, ceiling roses, lamp holders, brackets, ,removing material to store for keeping in safe custody and making good to disturbed surfaces as complete all as specified and directed .
M&L point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC Casing capping with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth dolly incl suitable sizes moduler boxes with cover plate for mounting the moduler switches/regulators/sockets complete all as specified for (a) One light controlled by one 5A switch. Notes: a) Colour coding shall be followed as given below:- i) Phase - Red ii) Neutral - Black iii) Earth - Green
All as per item No. 13 above but for One fan point controlled by one 5A Switch complete all as specified and directed .
All as per item No. 13 above but for One 5A switch socket point on same board board complete all as specified and directed .
All as per item No. 13 above but for One 5A switch socket point on independent board complete all as specified and directed .
M&L point wiring complete with 4 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make drawn through & including PVC caping casing with Accessories fixed on wall/ceiling/truss etc with metallic ISI make terminal boxes fix on wall including one PVC insulated & unsheathed multistranded copper conductor 4.0 Sq. mm as earth continuity conductor connected to common earth dolly for single board having 3 x 5 Amps and 1 x15 Amp switch socket point on the same board complete including moduler box and cover plate complete all as specified and directed . Notes:- a) Colour coding shall be followed as given below:- i) Phase - Red ii) Neutral - Black iii) Earth - Green
Disconnecting & taking down, strip opening, cleaning all parts and packing of ceiling fan/wall mounted fan of any make and size & greasing ball bearing with specified quilty grease including Preparation of painted surfaces of ceiling fan & applying one coat of synthetic enamel white paint by spray painting complete & re-comissioning the same including making electric connection complete all as specified & directedall as specified. Note : Old damaged unserviceable fan handed over to dockyard authority.
S & F modular switch 1 way 6A, 1 module complete all as specified and directed .
S & F modular switch 1 way 16A, 1 module complete all as specified and directed .
S & F modular socket, 6A - 2/3 pin combined 2 modules complete all as specified and directed .
S & F modular socket 6/16A,2/3 pin, combined 2 module complete all as specified and directed .
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed .Make :
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed .
Supply and fixing in replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rosecomplete all as specified and directed .
M&L for sub-main wiring with 2 runs of 6.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing & caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 6.0 sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location,complete all as specified and directed . Note (i) : (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (ii) 2 runs of 6 Sqmm copper cable and one run of PVC casing & caping shall be measured as one unit.
M&L for sub-main wiring with 2 runs of 4.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing & caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 4.0 sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location,complete all as specified and directed . Note (i) : (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (ii) 2 runs of 4 Sqmm copper cable and one run of PVC casing & caping shall be measured as one unit.
Disconnecting & taking down old Unservicable cable & Supply laying & testing cable XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 100 volts grade with stranded aluminium conductor of size 10sqmm 4 core,complete all as specified and directed.
Disconnecting & taking down old Unservicable cable & Supply laying & testing cable XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 100 volts grade with stranded aluminium conductor of size 25sqmm 4 core, complete all as specified and directed .
S&F in repair Distribution Board double door, prewired type, made out of CRCA mild steel surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN DB 12 Way ,240V with bus bar rating 200Amps, dust and vermin proof suitable for incorporation of MCB'S and isolators etccomplete all as specified and directed .
S&F in repair Distribution Board double door, prewired type, made out of CRCA mild steel surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN DB 08 Way ,240V with bus bar rating 200Amps, dust and vermin proof suitable for incorporation of MCB'S and isolators etc complete all as specified and directed .
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting TPN 6 way, 440 volts with bus bar rating 100 Amps, dust and vermin proof suitable for incorporation of MCB’s etc complete all as specified and directed .
Supply and fix MCCB 4pole 125A, 16KA, complete all as specified and directed .
S & F in replacement of MCB, C Curve type suitable for 240 volts AC supply, SP 5 to 32A with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed .
S & F in replacement of MCB, C Curve type suitable for 240 volts AC supply, SPN 40 to 63A with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed .
S & F ceiling rose surface bakelite 65 x 50mm, flush type, 3 terminals complete all as specified and directed .
Supply and install hi wall split units indoor/outdoor of 2 TR capacity complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2.of capacity as shown. Note :(a) Rate of supporting brackets for outdoor unit is deemed to be included in rate quoted.
Supply and fix Single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240V complete all as specified and directed .
S&F for Rigid non-metallic PVC conduit 20mm dia with complete of all tees,bends,elbows, reducers, mouth tube ends fixing accessories such as GI saddles, full threded screws and (Narayan) nylon rawl plugs etc surfaced on walls/roofs complete all as specified and directed .
S&F for Rigid non-metallic PVC conduit 40 mm dia with complete of all tees,bends,elbows, reducers, mouth tube ends fixing accessories such as GI saddles, full threded screws and (Narayan) nylon rawl plugs etc surfaced on walls/roofs complete all as specified and directed .
S & F and clamping jointing copper tubing for suction line and for liquid discharge incl duly insulated with suitable insulation material including making hole in wall for passing through amd making to the disturb surface complete all as specified and directed.
RAJENDRA CONSTRUCTION (BID ID -3470208)
D S MADANE ENGINEERS AND CONTRACTORS (BID ID -3465927)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.27 MB
Tender Documents
Tender Documents • 1.18 MB
BOQ
BOQ • 6.97 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .