Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹30.1 L
EMD Value
₹60,160
Closing Date
27 Oct 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
EE, ADA Ajmer
ADA, Ajmer
Remaining Work of Fouth Floor at New Collectrate Building, Ajmer.
2026_ADA_604145_1
NIT 30/2026-27(1)
Open Tender
Electrical Works
Percentage
60 days
ADA
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
ADA, Ajmer
₹60,160
Yes
16 Oct 2026
16 Oct 2026
28 Oct 2026
16 Oct 2026
27 Oct 2026
16 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, U/UTP (Unscreened/ Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest amendments of ANSI/TIA/EIA-568, The copper conductors should be balanced twisted in pairs, separated by a cross-member fluted pair divider & protected by LSZH Jacket. Certified performance in a 4- connector configuration up to 100 Mtrs channel requirements & transmission frequencies ranging from 250 to 500 Mhz. in existing MS/PVC Conduits/ casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. | 7,500 | MTR | 44 | ₹3,30,000 |
| 2 | Supply, Drawing and OLTS Testing, of OM2 Multi mode (50/125 µm) glass optic fiber cable, as per latest amendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974- 2, 2-20, 2-21/ ITU G.651 with outer sheath, cable should be used for LAN and WAN back bones, for indoor/outdoor installations these sheathed cable be placed in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect. | - | - | - | - |
| 3 | 6 fiber | 500 | MTR | 107 | ₹53,500 |
| 4 | Supply & fixing of square Faceplate for Flush/ Surface Mount Information Outlets Single/Dual or Quad Aperture with dust cover, material should be High-impact, flame retardant, thermoplastic, UL listed material, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. | - | - | - | - |
| 5 | Dual Aperture | 230 | EACH | 97 | ₹22,310 |
| 6 | Supply, Installation, Testing and Commissioning of Rack mounted 19" 1U, 24 Port loaded, CRS chassis, powder coated, sheet steel, High-impact, flame retardant, thermoplastic, UL Listed, Modular Patch Panels with Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required. All as per pre approved by Engineer in charge. | - | - | - | - |
| 7 | Modular Patch Panel Loaded with Cat -6 1/0 | 3 | EACH | 7,128 | ₹21,384 |
| 8 | Supply, Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest amendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IECС 60603-7-51, EN 60603-7, IEEE 802.0an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.0af / IEEE 802.0at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocol (VOIP). | - | - | - | - |
| 9 | Cat 6, U/UTP (Unscreened/Un-shielded Twisted Pair) Patch Cord | - | - | - | - |
| 10 | 1 Mtr | 230 | Nos. | 204 | ₹46,920 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
1.pdf
Tender Documents • 10.72 MB
BOQ_1071563.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .