Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG 793009 MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | ₹7.3 L Quoted ₹7.5 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹7.8 L+₹33,800 (4.52%)Rejected-Finance BALIJAN PANIHARA GAON PO DINJOY CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | DIBRUGARH | ASSAM | 786184 | ₹7.8 L+₹33,800 (4.52%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹7.9 L+₹45,965 (6.14%)Rejected-Finance | ₹7.9 L+₹45,965 (6.14%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹8.0 L+₹51,765 (6.92%)Rejected-Finance SUDHA RANI VILA GROUND FLOOR 65 NASKAR PARA ROAD KOLKATA 700041 | KOLKATA | KOLKATA | WEST BENGAL | 700041 | ₹8.0 L+₹51,765 (6.92%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹8.0 L+₹54,950 (7.34%)Rejected-Finance | ₹8.0 L+₹54,950 (7.34%) | L5 | Rejected-Finance Being L5 |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
17 Jun 2020, 6:00 pmClosed
GE (AF) Mohanbari
GE (AF) Mohanbari
REPAIR AND MAINTENANCE TO CEILING FAN, EXHAUST FAN, WALL MOUNTED FAN, TABLE FAN AND OTHER CONNECTED E/M WORKS AT AFS MOHANBARI UNDER GE (AF) MOHANBARI.
2020_MES_346245_1
NIT No . 8001/229/01/E8 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AFS Mohanbari
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Mohanbari
₹14,000
Yes
8 Jul 2020
20 May 2020
19 Jun 2020
20 May 2020
17 Jun 2020
4 Jun 2020
Amount
Taking down ceiling fan any size from its location including disconnecting from ceiling rose, after removing carefully false celing wherever necessary and removing blades, opening of fan and cleaning of bush / ball bearing with kerosine oil, filling up ball bearing with grease and mobile oil and changing of bush bearing, locking nut, screw, split pin, check nut, rubber real wherever required tightening of stator up and bottom cover in position; washing body, blades, canopies with detergent soap powder; preparation of old painted surfaces by filling cavaties with suiatble filler ,testing and re - hanging fan and false ceiling in position and making electric connection using 0.5 Sqmm copper three core cable (length not exceeding 0.5 meter) from ceiling rose to fan complete all as specified and directed by Engineer-in-charge. (Spare wherever required to be renewed shall be measured and paid under relevant item here-in-after.)
Material and labour for checking of ceiling fans upto 1400 mm after taking down the fan carefully and removing from site to workshop including rewinding of fan coil with super quality, super enameled copper wire of suitable gauge and heat varnishing and refixing the same in original position including greasing of bearings & other moving parts and replacement of split pin, jam nut and rubber bush and testing complete all as specified and directed by Engineer-in-charge
Repair/maintenance of ceiling fan of any sweep at any height by replacing unserviceable capacitor, tightening the loose connections if any including testing for efficient functioning complete all as specified and directed by Engineer-in-charge (Note: Capacitor of required capacity shall be measured & paid under respective item.)
Taking down of exhaust fan/wall mounted fan/pedestal fan/table fan upto 450 mm sweep, opening, replacement of unserviceable accessories, oiling, greasing, complete overhauling of fan and re-assembling and testing complete for efficient functioning after fixing/hanging in position including provision of 0.5 sq mm copper three core cable (length not exceeding 0.5 metre) from ceiling rose to fan complete all as specified and directed by Engineer-in-charge
Repair/maintanance of exhaust fan/wall mounted fan/ table fan/pedestal fan (of any sweep) by replacing unserviceable capacitor/tightening the loose connections if any including testing for efficient functioning complete all as specified and directed by Engineer-in-charge (Note: Capacitor of required capacity shall be measured & paid under respective item.)
Material and labour for checking of Exhaust fans upto 450 mm after taking down the fan carefully and removing from site to workshop including rewinding of fan coil with super quality, super enameled copper wire of suitable gauge and heat varnishing and refixing the same in original position including greasing of moving parts and testing complete to make it fully fuctional complete all as specified and directed by Engineer-in-charge
Material and labour for checking of wall mounted fan any sweep after taking down the fan carefully and removing from site to workshop including rewinding of fan coil with super quality, super enameled copper wire of suitable gauge and heat vernishing and refixing the same in original position including greasing of moving parts and testing complete to make it fully fuctional complete all as specified and directed by Engineer-in-charge
Material and labour for checking of pedestal/ table fan any sweep after taking down the fan carefully and removing from site to workshop including rewinding of fan coil with super quality, super enameled copper wire of suitable gauge and heat vernishing and refixing the same in original position including greasing of moving parts and testing complete to make it fully fuctional complete all as specified and directed by Engineer-in-charge
Material and labour for painting of ceiling fans upto 1400 mm sweep carefully, dismantling fan blades and painting with one coat of synthetic enamel paint including filling cavities with filler after cleaning all dust etc complete all as specified and directed by Engineer-in-charge
Material and labour for painting of exhaust fan/wall mounted fan/ table fan/pedestal fan (of any sweep) carefully, dismantling fan blades and painting with one coat of synthetic enamel paint including filling cavities with filler after cleaning all dust etc complete all as specified and directed by Engineer-in-charge
Supply only ceiling fan capacitos 2.5/4 mfd ISI marked suitable for 230 Volts AC complete all as specified and directed by Engineer-in-charge. (Note: To be incorporated in item no. 3 and 5 above)
Supply only gun metal bush of sizes suitable for ceiling fan upto 1400 mm sweep complete all as specified and directed by Engineer-in-charge
Supply only gun metal bush of sizes suitable for exhaust fan / wall fan/ pedestal fan/table fan upto 450 mm sweep complete all as specified and directed by Engineer-in-charge
Supply only ball bearing suitable for Ceiling Fan / Exhaust Fan / Wall Fan / Table fan/ Pedestal fan complete all as specified and directed by Engineer-in-charge
Supply and fixing in repair stepped type electronic fan regulator flush type, single module complete all as specified and directed by Engineer-in-charge
Supply and fixing in repair Modular Fan step regulator, 120 watt, 2 module as per existing make and size. complete all as specified and directed by Engineer-in-charge
Supply and fixed in repairs MS clamp made out of 25 mm x 6 mm thick flat iron, including nuts and bolts, washers and "S" hook made out of 25 mm dia MS round bar complete all as specified and directed by Engineer-in-charge
Supply and fixed in repairs MS down rod heavy duty made out of 20mm dia MS tube 1mm thick wall thickness for hanging of ceiling fan and fixing including joist of suitable size, bolts, nuts, washers, 2 no. of rubber insulator and driliing holes as required. complete all as specified and directed by Engineer-in-charge
Supply and fixed in repairs plastic ventilation exhaust fan 200 mm sweep including necessary connection complete all as specified and directed by Engineer-in-charge
Supply and fixed in repairs plastic ventilation exhaust fan 250 mm sweep including necessary connection complete all as specified and directed by Engineer-in-charge
Material and labour for tubes 'Medium grade' galvanised of size 50mm bore in short lengths with all fittings and fixed complete between walls for hanging of ceiling fan etc complete all as specified and directed by Engineer-in-charge
Supply and fixed in repairs energy meter single phase two wire 240 V, 10-60 A Class 1.0 Prepaid meter as per IS 15884, 50 Hz, complying to IP51, with LCD display, KWh LED, encrypted STS based token system including CIU unit and enclosure complete all as specified and directed by Engineer-in-charge Make. L&T cat no. WM101BC7ASPREPAIDB or equivalent of Siemens/ Havells India Ltd/ Secure Meters/ Schneider (Note: 1. Old Energy meter will be deposited in MES store yard by contractor without any extra cost. 2. Rate quoted for prepaid meter shall be inclusive of software loading and training of MES personnel. )
Supply and fixed in repairs energy meter three phase four wire 240 V, 10-60 A Class 1.0 Prepaid meter as per IS 15884, 50 Hz, complying to IP51, with LCD display, KWh LED, DG sensing facility, encrypted STS based token system including CIU unit and enclosure complete all as specified and directed by Engineer-in-charge Make. L&T cat no. WR300BC7ASPREPAIDB or equivalent of Siemens/ Havells India Ltd/ Secure Meters/ Schneider (Note: 1. Old Energy meter will be deposited in MES store yard by contractor without any extra cost. 2. Rate quoted for prepaid meter shall be inclusive of software loading and training of MES personnel.)
Supply only split pin and jam nut of suitable size complete all as specified and directed by Engineer-in-charge
M/S D G ENTERPRISE
KP GHOSH AND CO
R K CHAKRABORTY AND CO
D N ENTERPRISE
FREEZCON
M/S N K SAI TRADING
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .