Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | ₹2.2 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹2.3 Cr+₹9.9 L (4.53%)Rejected-Finance | ₹2.3 Cr+₹9.9 L (4.53%) | L2 | Rejected-Finance Not Being Lowest Bidder. |
| 3 | L3₹2.3 Cr+₹10.2 L (4.68%)Rejected-Finance 201 PLOT NO 32 SHALAKA BLDG TPS II JUHU ROAD SANTACRUZ WEST MUMBAI SUBURBAN MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | ₹2.3 Cr+₹10.2 L (4.68%) | L3 | Rejected-Finance Not Being Lowest Bidder. |
| 4 | L4₹2.3 Cr+₹11.2 L (5.15%)Rejected-Finance 801 VENUS BENECIA PAKVAN DINING LANE OPP RAJPATH CLUB S G HIGHWAY BODAKDEV AHMEDABAD 380053 | AHMADABAD | GUJARAT | 380053 | ₹2.3 Cr+₹11.2 L (5.15%) | L4 | Rejected-Finance Not Being Lowest Bidder. |
| 5 | L5₹2.3 Cr+₹11.7 L (5.36%)Rejected-Finance 6 NEW SADGURU NANIK INDUSTRIAL ESTATE OFF WESTERN EXPRESS HIGHWAY GOREGAON E MUMBAI 400063 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400063 | ₹2.3 Cr+₹11.7 L (5.36%) | L5 | Rejected-Finance Not Being Lowest Bidder. |
Tender Value
₹2.5 Cr
EMD Value
₹5.0 L
Closing Date
11 Jun 2022, 6:00 pmClosed
AGM(E-E)-IX
Operational Offices, Chennai Airport, Chennai-60016.
FMC for Repair and Maintenance of Internal and External Electrical Installations at AAI (Metro) Residential Colony, Operational Office and Other Ancillary Buildings at Chennai International Airport(2022-2024)
2022_AAI_116300_1
AAI/CHE/AMED-IX/FMC/2022
Open Tender
Electrical Works
Item Rate
730 days
Chennai
As per NIT
10 documents required · 10 mandatory
₹1,180
Yes
₹5.0 L
Yes
13 Feb 2025
21 May 2022
13 Jun 2022
21 May 2022
11 Jun 2022
21 May 2022
21 May 2022 - 6 Jun 2022
Amount
SH:I FMC for Internal and External Electrical installations
FMC for all Internal and External Electrical installations at AAI (IAD) Residential Colony i/c Community hall& school, Ancillary buildings i/c Admin Office, Intake substation, Central Substations, Dog Kennels, All Power Houses, WTP, NEW WTP, STP, CCR Hall, CISF Barracks at Pazhavanthangal, Fire Stations, MT Sections (Old & New), Ceremonial Lounge and All Pump Houses,S2 Police station etc., to ensure satisfactory serviceability through providing repair/maintenance services for all Internal & External Electrical installations involving repairs and maintenance of connected LT feeders to the buildings switch rooms etc., repair/replacement of circuit wiring, switches, lamps, chokes, fixtures etc. (Required replacement of materials shall be issued by AAI free of cost) i/c providing consumable material like cotton waste, oil, grease, etc., & other sundry material required for cleaning at site etc. as required, including ensuring 100 % serviceability of External and Internal Electrical installations, preventive maintenance, routine maintenance; breakdown maintenance; etc., i/c maintenance of records / data entries and documentation including effective supervision etc. ,on all days including Sundays and holidays.
SH:II Painting, Repainting, Rewinding & Miscellaneous
Re-painting of L.T. panels, chequered plate, electrical installations etc. with approved quality enamel paint of required colour in two coats with spray gun i/c scrapping & cleaning the surface complete as per site requirement and direction of E-I-C.
Rewinding of following fans as per original characteristics with super enamelled copper wire and `E' class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangement for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc. (To be carried out as & when required).
Exhaust fan ( 300mm/450mm Sweep)
Ceiling fan (1050mm /1200mm Sweep)
Wall mounted fan/pedestal fan (300mm/450sweep)
Air Circulator (450mm/600mm Sweep)
Lettering with one coat of approved shade of synthetic enamel paint in following size s on different places in English or Tamil etc. as reqd.
1" size (one word / name including special characters & digits)
2" size (one word / name including special characters & digits)
Re-painting of cable tray of all sizes (upto 600 mm wide) i/c supports etc. with good quality of paint in one or more coats including scraping, cleaning etc. of outer surface only complete as per site condition and direction of EIC.
Rates for extra mandays for providing services as and when required basis
Skilled (Electrician/ Mason/ Cable Jointer)
Helper
Dismantling of existing LT Cubical panel i/c electrical wiring, cables, switch gears, measuring instrument etc. , as required at site and transporting to AAI stores.
Providing Labour and Hire Charges for deploying Excavator (JCB) i/c Operator for tracing the cable faults, excavation and refilling of Cable trench after work etc., as required.
Providing Labour and Hire Charges for deploying Gas Cutting MACHINE i/c Cutter, Gases in Cylinder etc., for cutting of Chequered Plates, MS Angles as required.
Providing labour and hire charges for deploying Crane (upto 10 Ton) i/c operator for lifting/ Shifting of Equipments/ Cable Drums, etc., as required.
Locating the Cable fault on LT feeder cables laid directly in ground/ duct/ pipe including providing Cable Fault Tracer (Rental) etc., as required.
LT CABLES [ONLY IN CASE OF EMERGENCY]
Cleaning of cable trenches by lifting the cables, supporting the cables, removing waste materials I/c malba, debris etc., and transporting and dumping the same to waste dumping yard etc. as required.
Cleaning of bus ducts I/c removing of covers, checking of bus bars, bus supports, tightening of busses and supports and re-fixing of covers, testing, commissioning etc., as required.
Retrievel of one number PVC/XLPE insulated and PVC sheathed power cable of 1.1KV grade of size upto 120 Sqmm from the existing RCC/ HUME/ STONEWARE/ METAL/ GI PIPES/ Duct/ TRAY/ TERRACE etc., as required.
Supply and Installation of maintenance free copper bonded single rod earthing system inclusive of earthing rod size dia 17.2 mm length 3000mm, copper bonded earth terminal with ultra safe ground enhancement material ( Min 25Kg) and construction of Earth pit chamber and CI Cover for earth pit chamber etc. as required.
Replacement light fittings / fans with the following including supply of light fitting/fans and connections with 1.5 Sq.mm. PVC insulated copper conductor cable as required:
Linear general purpose LED light fitting aluminium housing( Crompton CCS-100-20-65-HL2-DP-NWH OR EQUIVALENT model of Wipro/Bajaj/Philips/Havells) on wall/ceiling/suspension chain
Heavy duty Exhaust fan 300mm,900rpm in the existing opening ( Make:Usha 300mm Aero clean plus or equivalent)
Heavy duty Exhaust fan 450mm in the existing opening ( Make:Usha 450mm Turbo Heavy Duty or equivalent)
Ceiling fan 1200 mm sweep ( Make: Usha Technix Plus or equivalent approved make)
Ceiling fan 1050 mm sweep ( Make:Usha Striker or equivalent approved make)
Air circulators Wall type 450 mm sweep ( Make : Usha 450mm Dominaire or equivalent approved make)
80W LED Flood Light ( make:Crompton LCNP-80-CDL/60-M) or equivalent model of Wipro/Bajaj/Philips/Havells)
LED Downlighter 1500 lumens, minimum 100lm/Watt ( Crompton CDR-205-15-57-SL-NWH or Equivalent model of Wipro/Bajaj/Philips/Havells)
400mm pedestal fan( make: Usha 400mm Mist Air ICY or Equivalent approved make)
400mm Wallmount fan( make: Usha 400mm Mist Air ICY or Equivalent approved make)
SH:III SUPPLY OF SPARE PARTS FOR MAINTENANCE & REPAIR WORKS
Supply of LED Bulb; shape GLS; 09 watts;minimum 95lm/watt, 220-240 volts; B22(Pin type), 6500K, Make Havells LHLDEUEBML8R009 or equivalent model of Wipro/Bajaj/Philips/Crompton)
Supply of LED Bulb;shape GLS; 15 watts; 220-240 volts; B22(Pin type), 6500K, Make Havells LHLDEREEMK8X015 or equivalent model of Wipro/Bajaj/Philips/Crompton)
Supply of 2.5 MFD Capacitor for Fan operated on single phase, 230 V, complete as required.
Supplying of PVC Cassing & Capping as and when required.
4" x 2" inch for AC Refrigerant Piping
Supply of Instant Electric water Geyser of minimum 3 litres storage capacity, wattage : 3000 W with all standard accessories etc. (Havells instanio 3L or equivalent)
Supply of Aluminium Conductor, XLPE insulated, PVC sheathed, armoured power cable of 1.1 KV grade of following Sizes conforming to IS 7098 (Part-1) as amended upto date as required. [AS AND WHEN REQUIRED BASIS ONLY]
3 X 10 sq. mm
3 X 16 sq. mm
4 X 10 sq. mm
4 X 16 sq. mm
4 X 25 sq. mm
3½ X 35 sq. mm
3½ X 95 sq. mm
3½ X 120 sq. mm
Supply of Copper Conductor, FR PVC insulated, PVC sheathed, un-armoured power cable of 1.1 KV grade of following Sizes conforming to IS 694 as amended upto date as required. [AS AND WHEN REQUIRED BASIS ONLY]
3c x 1.5sq.mm
3c x 2.5sq.mm
3c x 4sq.mm
4c x 4 sq.mm
3c x6 sq.mm
1c x70sqmm(for earthing)
Supply of Single core flexible copper conductor Flame Retardent Low Smoke (FRLS) insulated wires, 1100 Volts confirming to IS:694 of following sizes:
1.0 sq.mm single core copper cable
1.5 sq.mm single core copper cable
2.5 sq.mm single core copper cable
4 sq.mm single core copper cable
6 sq.mm single core copper cable
Supply of Copper Conductor, XLPE insulated, PVC sheathed, armoured power cable of 1.1 KV grade of following Sizes conforming to IS 7098 (Part-1) as amended upto date as required.
3c x 2.5sq.mm
3c x 4sq.mm
5c x 4 sq.mm
Supplying following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply of following rating and breaking capacity and pole MCCB with micro processor LSI release and Adjustable overload current setting,complies with IEC 60947-2,Direct mounting arrangement for extended rotary handle etc. as required.
Supply of following Modular switches, Modular sockets, PVC boxes, Modular base & cover plates etc. as required.
Supply of 10A Modular Switch, Anchor Roma make code No.21011 or equivalent.
Supply of 20A Modular Switch, Anchor Roma make code No.21066 or equivalent.
Supply of 10A Modular Socket, Anchor Roma make code No.30373 or equivalent.
Supply of 25A & 10A Modular Twin Socket, Anchor Roma make code No.34374 or equivalent.
Dummy plate, Anchor Roma make code No.21598 or equivalent.
1 or 2 Module PVC box, Anchor Roma make code No.21281or equivalent.
3 Module PVC box ,Anchor Roma make code No.20449 or equivalent.
4 Module PVC box, Anchor Roma make code No.21292 or equivalent.
6 Module PVC box,Anchor Roma make code No.30511 or equivalent.
9 Module PVC box,Anchor Roma make code No.30704 or equivalent.
Supply of 1 or 2 Module base & cover plate , Anchor Roma make or equivalent. for modular boxes.
Supply of 3 Module base & cover plate , Anchor Roma make code No.21372 WH or equivalent. for modular boxes.
Supply of 4 Module base & cover plate ,Anchor Roma make code No.21339 WH or equivalent. for modular boxes.
Supply of 6 Module base & cover plate , Anchor Roma make code No.21340 WH or equivalent. for modular boxes.
Supply of 8/9 Module base & cover plate , Anchor Roma make code No.21431 or equivalent. for modular boxes.
SH: IV CMC & Lift License Items
Obtaining Lift license from lift licensing authority i.e govt of tamilnadu by applying three months prior to the date of expiry of the license as required and as per the direction of Engineer-in-Charge.
All inclusive Comprehensive maintenance contract charges for 10KVA 3ph-3ph Numeric make UPS system installed at Ceremonial lounge etc. complete as required.
SH: V DSR E&M 2018 ITEMS
Execution of works as per CPWD Delhi Schedule of Rate (E&M) 2018 as and when required for a fixed amount for 1 st year and 2 nd year as mentioned below. (Note: Rate shall be quoted for 1 st year and 2 nd year in the Indian Rupees only for a fixed amount of Rs.10,00,000/- as clarified below and as per techo-commerical specification P.No TCS -15 of tender document. For Example: If desired to quote 5% above on DSR-2018 rates, the rate column shall be filled as Rs.Rs.10,50,000/- If desired to quote 5% below on DSR-2018 rates, the rate column shall be filled as Rs.9,50,000/-
For 1st year - For a fixed amount of Rs.10,00,000/- on CPWD Delhi Schedule of Rate (E&M) 2018
For 2nd year - For a fixed amount of Rs.10,00,000/- on CPWD Delhi Schedule of Rate (E&M) 2018
SHRADDHA ENGINEERING AND FACILITY SERVICES
DElite System Engineering (India) Pvt. Ltd.
ABHISHEK INTEGRATIONS LIMITED
PREMIER ENGINEERING TECHNICS PVT. LTD.
CIS GLOBAL INFRATECH PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .