Assistant Engineer, P.W.Dte. High Court Elecl. SD
Office of the Assistant Engineer, P.W.Dte. High Court Electrical Sub Division 1st Floor, Sesqui-Centenary Building, High Court, Calcutta, KOLKATA 700001
Electrical Installation cum renovation and modification type Electrical work for converting the reading room at the ground Floor situated just right side of the Judges Lift into one full-fledged Conference Room at Main Building of the Honorable HC...
2026_WBPWD_5015117_1
WBPWD/AE-HCESD/NIQ-11/2026-27
Open Tender
ELECTRICAL WORKS M/R
10 days
High Court Electrical Sub-Division PWDte.
Please refer Tender documents.
6 documents required · 6 mandatory
₹9,400
8 Jun 2026
8 Jun 2026
22 Jun 2026
8 Jun 2026
19 Jun 2026
8 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 0.0 | Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall Inverter split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC
Cooling Capacity- 6.1 kW (Minimum) , Air Flow Rate:800 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min) [Draft SOR Final Copy Item no. 2/2.2] M: O-General/Mitsubishi Heavy Duty/Daikin | 6 | Each | - | - | Dismantling the existing defective pipe line 5'' MS pipe after cutting by skilled manpower, not causing any damage to near by line and gadgets incl. providing of all other accessories as per instruction of EIC. |
| 0.0 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
a) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm [Draft SOR Final Copy Item no. 3/3.04] | 32 | RM | - | - | S & F of 5'' dia 3mm thick MS pipe after cutting, polishing, grinding & leathing as per requirment by making proper bending, jointing as required for proper execution of work. |
| 0.0 | b) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm [Draft SOR Final Copy Item no. 3/3.01] | 32 | RM | - | - | Charge for hiring of welding machine in this occesion including transportation cost. |
| 0.0 | Supply & Laying of 4 core 2.5 sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c.(Make- Havells/Finolex/KEI/Polycab as approved by E.I.C) | 35 | Mtr | - | - | Charge for the following skilled & unskilled man power to be required for the work. |
| 0.0 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. [Draft SOR Final Copy Item no. 5] | 12 | Mtr | - | - | b) Fitter - 1 no (For 2 days). |
| 0.0 | Supplying, fabrication & fixing 2 Nos. M.S. Angle of size (50 mm x 50 mmx6mm) for making platform for installation of outdoor unit of 3.0/4.0 TR ceiling concealed AC incl. drilling 2 nos holes in each Angle including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 40 mm x40mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (40 mm x 40 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be baricated & safe for ODU maintenance. Area of the platform is 2Mtr. x 1Mtr. or as per Machine configuration & load with adequate service access as per direction of EIC. | 4 | no. | - | - | c) Helper -1 no (For 2 days). |
| 0.0 | Supply & laying 1.1 KV grade 3 core 4 sqmm flexible copper Cable with screw, saddle,drill machine nut bolt etc all necessary items needed for connection. (from starter to A.C outdoor Connection)(make: Havels/ Polycab/ Finolex/ ee/ Gloster as per approved by EIC) | 38 | Mtrs | - | - | Supply & delivery of materials for above work. (2 nos. occassions) |
| 0.0 | Supply & fixing automatic single phase AC starter of 21Amp capacity equipped with Timecheck, Voltcheck & Ampcheck and 3-digit display (Make- Electron-model no.-OPL-3+ or equivalent model of LT/Legrand as per dierction of E.I.C) to be fixed on wall and S & F 4 module a1 modular type switchboard on wallincl. making necessary connections with PVC cu. wire and earth continuity wire etc. | 2 | Each | - | - | Supply & delivery of materials for above work. (2 nos. occassions) |
| 0.0 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene / PVC rigid pipe and by the prelaid GI fish wire and making necy. connection as required [E-9/1] a) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [ E-9/1(v)] | 150 | Mtr | - | - | Supply & delivery of materials for above work. (2 nos. occassions) |
| 0.0 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works (E-16 / 7) a) 25 mm size | 150 | Mtr | - | - | Supply & delivery of materials for above work. (2 nos. occassions) |