Tender Value
₹10.2 L
EMD Value
₹12,800
Closing Date
12 Sept 2025, 5:00 pmClosed
Shri. Deenabandhu Sethi
The Office of Staff Officer EandM Jagannath Area Talcher-759103
Day to day repair and maintenance of Air Conditioner of N.S. Central Hospital and Regional Hospital of CH Area, Talcher for the period of two (02) years.
2025_MCL_342414_1
GM(JA)/EnM/e-Tender/25-26/ E-779/44 DTD. 26/08/2025
Open Tender
Electrical and Maintenance Works
Item Rate
730 days
NSCH, Talcher/Regiopnal Hospital Dera
As per NIT
4 documents required · 4 mandatory
₹12,800
17 Feb 2026
26 Aug 2025
15 Sept 2025
27 Aug 2025
12 Sept 2025
27 Aug 2025
27 Aug 2025 - 1 Sept 2025
Amount
Dry AC maintenance, also known as AC dry service, involves cleaning and drying the AC's internal components without using water: 1) Cleaning Filters: Remove and clean the air filters with water, vacuum cleaner, or a cleaning brush. 2) Cleaning the Indoor Unit: Clean the indoor drain tray and exterior components with a dry cloth or blower. 3) Outdoor Unit Cleaning: Clean the outdoor unit with a blower to remove dust and debris. (2 times a year for 2 year for 81 nos AC = 2 X 2 X 81= 324 each);
Wet maintenance of installed Air Conditioners: A. Clean the indoor unit:Remove the filter and wash it with water or vacuum it. Clean the indoor unit's outer shell and fan blades with a cloth and cleaning solution, if needed. Use a water jet pump (if available) to clean the evaporator coils, ensuring water flows freely. B. Clean the outdoor unit:Clean the condenser coils with a soft brush or cloth to remove dirt, debris, and leaves. If using a water jet pump, gently spray the condenser coils to remove stubborn dirt and debris. Check for any blockages in the drainage line and clear them with a mixture of water and mild detergent. C. Dry the unit:Use a clean cloth or towel to wipe down the unit and remove any excess water. Let the unit air dry completely before reconnecting the power. (Once a year for 2 years for 81 nos AC = 2 X 81= 162 nos.)
Supply & fixing of new compressor for replacement in a 1.5 Ton Air Conditioner
Supply & fixing of new compressor for replacement in a 2.0 Ton Air Conditioner
Supply & fixing of compressor starting relay in Air Conditioner
Supply & fixing of compressor starting capacitor 80/100/120mF, 400 volts in Air Conditioner.
Supply & fixing of running capacitor 50mF, 400 volts in Air Conditioner
Supply & fixing of fan capacitor 4/6 mfd, 400 volts in Air Conditioner.
Supply & fixing of temperature sensor (cool & hot) in Air Conditioner.
Supply & fixing of condenssor in 1.5/2.0T Air conditioner; in case of leakage in aluminum or unrepairable existing condenser.
Rewinding & fixing of fan motor complete as required including dismantling and installation of the same.
Supply and fixing of indoor fan motor (1.5/2.0Ton split type, complete sets) in Air Conditioner.
Supply and fixing of outdoor fan motor (1.5/2.0 Ton split type, complete sets) in Air Conditioner.
Supply & fixing of fan blower for split type Air Conditioners.
Supply & fixing of fan blade for split type Air Conditioner.
Painting with black Enamel paint on body of a single outdoor unit split type Air Conditioner.
Supply & fixing of Remote kit in a split type Air Conditioner.
Supply & fixing of Indoor PCB for 1.5/2 Ton (inverter Model) in a split type A.C
Supply & fixing of outdoor PCB for 1.5/2 Ton (inverter Model) in a split type Air Conditioner.
Supply & fixing of outdoor PCB for 1.5/2 Ton (non-inverter Model) in a split type Air Conditioner.
Supply and charging of Gas Freon R-22/R-32/R-410 as per requirement in a split type Air Conditioner after detecting and sealing the leakage or on replacement of pipe/ compressor/ condenser.
Supply & fixing of insulation foam tape in Air Conditioner
Supply & fixing of wrapper tape in Air Conditioner.
Supply & fixing of Copper pipe 1/2 inch in Air Conditioner.
Supply & fixing of Copper pipe, 1/4 inch in an Air Conditioner
Supply & fixing of Drain pipe in an Air Conditioner
Attaining breakdown of Air Conditioners such as wire/circuit damage by rat or short circuit, water leakage from indoor unit, low cooling, no cooling and clear oil/lubricant of compressor mixed with the refrigerant etc. by a Skilled Technician.
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/S. R.K. ELECTRICAL (BID ID -1182797)
JEET ELECTRICALS (BID ID -1181417)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.25 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 1.04 MB
Tendernotice_2.pdf
PDF • 1.69 MB
BOQ_354968.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .