| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.0 L+₹79,275 (6.01%)Rejected-Finance 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | VARDHMAN INTERNATIONAL L2 | DEV RAJ MAGOTRA L1 |
|---|---|---|---|---|---|
| 1.00 | Supply and fixing Air terminations Single pointed aluminium rod 12mm dia and 300mm long with necessary fixing through nut, bolts, washers or welding arrangement on roof including taking down of old rusted all as directed. | 35 | Each | 248 ₹8,680 | 100 ₹3,500 Lowest |
| 2.00 | Supply and fixing Air terminations Single pointed copper rod 12mm dia and 300mm long with necessary fixing through nut, bolts, washers or welding arrangement on roof including taking down of old rusted all as directed. | 18 | Each | 650 ₹11,700 | 150 ₹2,700 Lowest |
| 3.00 | Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm, drilled and screwed including 3 nos 8mm dia 25 mm hexogonal head screw including taking down old rusted as specified & directed. | 20 | Each | 460 ₹9,200 | 400 ₹8,000 Lowest |
| 4.00 | Supply and fixing rectangular Porcelein insulators for copper/aluminium/GI strip complete all as specified and directed. | 500 | Each | 160 ₹80,000 | 15 ₹7,500 Lowest |
| 5.00 | Supply and fixing solar water heater panel 100/200 LPD (Evacuated Tube Collector)servicing, cleaning, brazing, cutting, opening of glass etc with replacement of end caps & rubber cover complete all as specifed and directed. | 2 | Each Job | 28,500 ₹57,000 | 500 ₹1,000 Lowest |
| 6.00 | Supply and fixing Heating element capacity 2/3 KW for Solar water heater 1000/500 LPD. | 25 | Each | 520 ₹13,000 | 400 ₹10,000 Lowest |
| 7.00 | Supply and fixing solar flat plate collector complete all as specified and directed. Make : Recold/Inter solar pvt Ltd | 15 | Each | 18,000 ₹2,70,000 | 17,300 ₹2,59,500 Lowest |
| 8.00 | Supply and fixing solar water heater tank capacity 1000/500 LPD (Innet tank material - stainless steel 304,inner tank thickness 0.5mm, Insulation thickness 45mm, Insulation material - Polyurethene foam (PUF), end cap thickness 0.4mm & Pipe material - stainless steel 304 & pipe size 3/4") complete all as specified and directed. make - Inter Solar Pvt Ltd | 2 | Each | 60,000 ₹1,20,000 | 51,200 ₹1,02,400 Lowest |
| 9.00 | Supply and fixing solar water heater tank capacity 350/300 LPD (Innet tank material - stainless steel 304,inner tank thickness 0.5mm, Insulation thickness 45mm, Insulation material - Polyurethene foam (PUF), end cap thickness 0.4mm & Pipe material - stainless steel 304 & pipe size 3/4") complete all as specified and directed. make - Inter Solar Pvt Ltd | 15 | Each | 25,000 ₹3,75,000 Lowest | 44,700 ₹6,70,500 |
| 10.00 | Supply and fix GI tubing medium grade of 15 mm bore complete all as specified and directed. | 250 | Running metre | 160 ₹40,000 | 105 ₹26,250 Lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
21 Nov 2025, 6:00 pmClosed
CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
REPAIR AND MAINT OF EARTHING/ SOLAR HEATING APPLIANCES, LIGHTENING PROTECTION AND ELECTRIC ENERGY METERS OF VARIOUS CENTRAL INSTITUTE AND BLDGS UNDER GE (SOUTH) UDHAMPUR
2025_MES_738127_1
CWE/U(S)-65/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Udhampur
As per NIT
7 documents required · 7 mandatory
₹500
GE (South) Udhampur
₹30,000
Yes
26 Dec 2025
1 Nov 2025
27 Nov 2025
1 Nov 2025
21 Nov 2025
15 Nov 2025
Amount
Supply and fixing Air terminations Single pointed aluminium rod 12mm dia and 300mm long with necessary fixing through nut, bolts, washers or welding arrangement on roof including taking down of old rusted all as directed.
Supply and fixing Air terminations Single pointed copper rod 12mm dia and 300mm long with necessary fixing through nut, bolts, washers or welding arrangement on roof including taking down of old rusted all as directed.
Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm, drilled and screwed including 3 nos 8mm dia 25 mm hexogonal head screw including taking down old rusted as specified & directed.
Supply and fixing rectangular Porcelein insulators for copper/aluminium/GI strip complete all as specified and directed.
Supply and fixing solar water heater panel 100/200 LPD (Evacuated Tube Collector)servicing, cleaning, brazing, cutting, opening of glass etc with replacement of end caps & rubber cover complete all as specifed and directed.
Supply and fixing Heating element capacity 2/3 KW for Solar water heater 1000/500 LPD.
Supply and fixing solar flat plate collector complete all as specified and directed. Make : Recold/Inter solar pvt Ltd
Supply and fixing solar water heater tank capacity 1000/500 LPD (Innet tank material - stainless steel 304,inner tank thickness 0.5mm, Insulation thickness 45mm, Insulation material - Polyurethene foam (PUF), end cap thickness 0.4mm & Pipe material - stainless steel 304 & pipe size 3/4") complete all as specified and directed. make - Inter Solar Pvt Ltd
Supply and fixing solar water heater tank capacity 350/300 LPD (Innet tank material - stainless steel 304,inner tank thickness 0.5mm, Insulation thickness 45mm, Insulation material - Polyurethene foam (PUF), end cap thickness 0.4mm & Pipe material - stainless steel 304 & pipe size 3/4") complete all as specified and directed. make - Inter Solar Pvt Ltd
Supply and fix GI tubing medium grade of 15 mm bore complete all as specified and directed.
Supply and fix GI tubing medium grade of 20 mm bore complete all as specified and directed.
Supply and fix GI tubing medium grade of 25 mm bore complete all as specified and directed.
S&F Bib taps size 20mm , cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass errule and fixed complete all as specified and directed.
S&F Foot valves size 20mm,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F Stop valves size 20mm,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe 20mm (Minimum weight 20mm-210gms) and fixed complete all as specified and directed.
S&F flexible Rubber hose pipe of suitable size for hot water , of suitable length (set of two) for inlet/outlet connections of solar water tank with all accessories (like clamps,screws etc.) complete all as specified and directed. Note:- All the joints shall be made with nuts & bolts to get proper conductivity.
Supply and fix aluminium Strip 25 x 3.15mm and fixing screws from aluminium air termination rod to test point terminal as down conductor and roof conductor including taking down of old rusted all as directed. Note:- All the joints shall be made with nuts & bolts to get proper conductivity.
Supply and fix Copper Strip 20 x 3.15mm and fixing with screws as continuous lead from Copper air termination rod to test point ternimal as down conductor, roof conductor and continuous earth lead to test point terminal including taking down of old rusted all as directed. Note:- All the jonts shall be made with copper brazing to get proper conductivity.
Fixing only old aluminium/ copper strip of any size on insulator including straightening to old strip through nut, bolts and washer or welding and insulators as required on site etc complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6.00mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level with top edge of earth plate not less than 1.5 m below the normal ground level) connected to galvanised iron strip 25 x 4mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in elelctrical plalte No 3 including charcoal dust, commen salt, 20mm bore GI medium grade watering pipe, 40mm dia GI light grade protection pipe with funel and wire mesh, PCC Pit in 1:2:4 type B 1 using 20mm graded stone aggregate with angle iron 40x40x5mm frame, RCC pit cover of suitable size complete all as specified and directed by engineer encharge and testing for required value complete. Note :- (i) Item include the cost of earth lead and GI protection pipe upto 7.5 mtr length. (ii) On completion of Earthing Contractor should check Earthing Results and submit the Test Report to Engr-in-charge. If desired results are not obtained then Earthing shall be redone by the contractor at his own cost.
M & L for Earthing complete with galvanised steel earth plate electrode of size 600x600x6.00 thick as earth electrode burried directly in ground earth plate not less than 2.25m deep below normal groung level with top edge of earth plate not less than 1.5 m below ground level connected to and including galvnised steel earth lead wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed inculding providing earth wire protection pipe GI light grade 15mm dia from earth plate to main switch board / panel , watering GI pipe medium grade 20mm dia with mesh and funnel at top , earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of characoal dust and salt all around the earth plate , earth work in any type of soil, remaning surplus excavated material all as required at site and specified in EP no 3 of SSR part I 2009 or directed by Engineer-in-Charge.Note :- (i) Item include the cost of earth lead and GI protection pipe upto 7.5 mtr length. (ii) On completion of Earthing Contractor should check Earthing Results and submit the Test Report to Engr-in-charge. If desired results are not obtained then Earthing shall be redone by the contractor at his own cost.
M&L for rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part - I of capacity 250 Ltrs.
M&L for rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part - I of capacity 500 Ltrs.
M&L for rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part - I of capacity 2000 Ltrs.
Supply and fix single phase prepaid/electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH
Supply and fix three phase prepaid/electronic meters temper proof LCD display with polycarbonate cover 415 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH
VARDHMAN INTERNATIONAL (BID ID -3479236)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
BOQ_826513.xls
BOQ • 0.60 MB
tender65.pdf
Tender Documents • 1.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .