| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹13.4 L+₹86,350 (6.88%)Rejected-Finance | L2 | Rejected-Finance HIGHER | |
| 3 | L3₹14.4 L+₹1.8 L (14.5%)Rejected-Finance | L3 | Rejected-Finance HIGHER | |
| 4 | L4₹14.9 L+₹2.3 L (18.6%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance HIGHER | |
| 5 | L5₹15.7 L+₹3.1 L (24.8%)Rejected-Finance | L5 | Rejected-Finance HIGHER |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
11 Aug 2022, 6:00 pmClosed
GE Amritsar
GE Amritsar PIN-143001
REPAIR / MAINTENANCE OF INTERNAL WIRING , DBs, FITTING FIXTURE AT MILITARY HOSPITAL AT AMRITSAR CANTT
2022_MES_535605_2
GE/ASR-25/2022-23
Open Tender
Civil Works
Item Rate
150 days
GE Amritsar
Class E, category bi
8 documents required · 8 mandatory
₹500
GE Amritsar
₹36,000
Yes
12 Dec 2022
26 Jul 2022
12 Aug 2022
26 Jul 2022
11 Aug 2022
29 Jul 2022
Amount
Taking down carefully copper/aluminium point wiring light, fan, socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc. removing materials to store for keeping in safe costudy or for taking credit and making good disturbed surface of walls, floors etc. Complete all as specified and directed by Engineer-in-Charge.
Material & labour for Point wiring for one light point / fan point / bell point / 5 Amp socket outlet point (independent point), controlled by one, one way switch with 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) (using colour code as per IS) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing specifications) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) as in earth wire (using green colour) and connected to common earth dolly, including making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour ; complete all as specified & directed by Engineer-in-Charge.
Material & labour for Point wiring for one light point / fan point / bell point / 5 Amp socket outlet point (independent point), controlled by Two , two way switches with 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) (using colour code as per IS) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) as in earth wire (using green colour) and connected to common earth dolly, including making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour ; complete all as specified & directed by Engineer-in-Charge.
All as per item No 2.00 above but one 5 Amp 3 pin socket outlet on independent board complete.
All as per item No 2.00 above but one 5 Amp 3 pin socket outlet on the same board with other switches complete.
Material & labour for Point wiring for one 16 Amp socket outlet point (independent point), controlled by one, one way switch with 2.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) (using colour code as per IS) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of 2.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) as in earth wire (using green colour) and connected to common earth dolly, including making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour ; complete all as specified & directed by Engineer-in-Charge.
Material & labour for Point wiring for one light point / fan point / bell point / 5 Amp socket outlet point (independent point), controlled by one, one way switch with 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) (using colour code as per IS) drawn into and including medium grade PVC conduit concealed (not less than 25 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing specifications) and including sunk Metal flush box , cover plate with suitable size of frame for fixing/mounting fitting like modular switches, sockets, including one continuous run of 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) (using green colour) as in earth wire and connected to common earth dolly, and making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour ; complete all as specified & directed by Engineer-in-Charge. Note :- The quoted rates under this item includes the cost of Metal flush box , cover plate with suitable size of frame for fixing modular switches/sockets/regulator etc.
Material & labour for Point wiring for one light point / fan point / bell point / 5 Amp socket outlet point (independent point), controlled by two , two way switches with 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) (using colour code as per IS) drawn into and including medium grade PVC conduit concealed (not less than 25 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing specifications) and including sunk Metal flush box , cover plate with suitable size of frame for fixing/mounting fitting like modular switches, sockets, including one continuous run of 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) (using green colour) as in earth wire and connected to common earth dolly, and making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour ; complete all as specified & directed by Engineer-in-Charge. Note :- The quoted rates under this item includes the cost of Metal flush box , cover plate with suitable size of frame for fixing modular switches/sockets/regulator etc.
All as per item No 7.00 above but one 5 Amp 3 pin socket outlet on the same board with other switches complete.
All as per item No 7.00 above but for one 5 pin 5 amps socket outlet on the independent board.
Material & labour for Point wiring for 15 Amp socket outlet point (independent point), controlled by one, one way switch with 2.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) (using colour code as per IS) drawn into and including medium grade PVC conduit concealed (not less than 25 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing specifications) and including sunk Metal flush box , cover plate with suitable size of frame for fixing/mounting fitting like modular switches, sockets, including one continuous run of 2.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) (using green colour) as in earth wire and connected to common earth dolly, and making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour ; complete all as specified & directed by Engineer-in-Charge. Note :- The quoted rates under this item includes the cost of Metal flush box , cover plate with suitable size of frame for fixing modular switches/sockets/regulator etc.
Supply & fixing for switch piano 5 amps flush type single pole one way complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for switch piano 5 amps flush type single pole two way complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for socket outlet flush type 2 in one 5 pin 6 amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for switch piano 15 amps flush type single pole one way complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for socket outlet 2 in 1, 5 pin 16 amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for Modular plate switch 6 amps single pole one way one module complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for Modular plate switch 6 amps single pole two way one module complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for Modular plate switch 16 amps single pole one way one module with indicator complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for modular plate socket 6 Amps 2 in 1, 5 pin combined shuttered type two module complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for modular plate socket 16 Amps 2 in 1, 5 pin combined shuttered type two module complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for modular fan regulator step type 120 Watt two module complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for Ceiling rose surface bakelite 65 mm x 50mm, two to three terminals with back plate of 3mm thick bakelite laminated hylem sheet of suitable size ; complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for lamp holder PVC/ polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs of ding dong bell AC 230 V single pole fixed over and including and suitable size sunk cast iron or pressed steel terminal boxes covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs bell push flush type single pole 5 Amps ; complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs sheet metal enclosure single pole and neutral with two pin and earth plug and socket with & including one single pole 415 volts MCB 20 amps 10KA ; complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing in repairs MCB single pole 240 Volts, 50Hz,vrupturing capacity 10 kA, C curve , conforming to IS 8828 of rating 6 to 32 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs MCB double pole 240 Volts, 50Hz,vrupturing capacity 10 kA, C curve , conforming to IS 8828 of rating 40 to 63 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs MCB double pole 240 Volts, 50Hz,vrupturing capacity 10 kA, C curve , conforming to IS 8828 of rating 100 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs factory made Sheet metal Enclouser Distribution Board single pole and neutral , 4 way 240 volt with double door, IP - 43 & IK-09 protection system with having 200 Amps 2 Nos bus bar for neutral bar and earth bus bar, DBs fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs factory made Sheet metal Enclouser Distribution Board single pole and neutral , 8 way 240 volt with double door, IP - 43 & IK-09 protection system with having 200 Amps 2 Nos bus bar for neutral bar and earth bus bar, DBs fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 12 way with IP-43 and IK-09 protection, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified and directed by the Engr-in-Charge. Note : cost of removing old wooden box and making good of surface as existing specifications i.e. brick work, plastering, whitewash/colour/ distemper etc is included in quated rate) complete all as specified.
Supply & Fixing in repairs MCCB Incomer distribution board double door vertical type made out of CRCA MS sheet surface with insulated material like polyester or with epoxy powder coating surface mounting TPN 4 way, 415 volts with copper bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB and IP 43 - IK 09 protection with and including 100 Amp 36 KA 4 pole MCCB with thermal - magnetic setting and Icu = Ics = 100% , including suitable type MCb with blank plate complete all as specified. Note :- The cost of removing old wooden/steel any type box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quoted rate)
Material and labour in repairs submain wiring with two single core PVC insulated multi stranded copper conductor cable FR of size 6 Sqmm 1100 volt grade (ISI marked ) drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 25 mm dia) along with fittings and accessories all fixed concealed on wall and surface on ceiling, with one 6 Sqmm single core multi stranded copper conductor FR as earth continuity to common earth doly as earth wire (Green colour) complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire with PVC conduit shall be measured and paid as one length.
Material and labour in repairs submain wiring with two single core PVC insulated multi stranded copper conductor cable FR of size 10 Sqmm 1100 volt grade (ISI marked ) drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 25 mm dia) along with fittings and accessories all fixed concealed on wall and surface on ceiling, with one 10 Sqmm single core multi stranded copper conductor FR as earth continuity to common earth doly as earth wire (Green colour) complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire with PVC conduit shall be measured and paid as one length.
Supply & Fixing in repairs wall/ceiling mounting LED 18 Watts tube light complete with accessories 1 x 18 watts LED, CCT of 6500 K, CRI >=80, THD <=20%, and lumen output 1810 Lm having intergrated electronic driver (SMPS based) with open ckt/output short ckt protection and surge protection suitable for domestic application 240 volts internally prewired with 1.5 sqmm twin twisted copper wire and connection ; complete all as specified and directed by the Engineer in Charge.
Supply & Fixing in repairs wall / ceiling mounting LED 09 watts tube light complete with accessories 1x 09 watts LED, CCT of 6500 K, CRI >=80, THD <=20%, and lumen output 950 Lm having integrated electronic driver (SMPS based) with open ckt / output short ckt protection and surge protection suitable for domestic application 240 volts internally prewired with 1.5 sqmm twin twisted copper wire and connections ; complete all as specified and directed by the Engineer in Charge.
Supply & Fixing in repairs energy saving new generation 15 Watt LED built up made up to injection moulded Polycarbonate housing with High Quality Polycarbonate UV Protected Milky diffuser having CCT of 6500 K, THD<=15, CRI>=80, integrated electronic LED driver with APFC and 3.5 kv inbuilt surge protection with ; complete all as specified and directed by the Engineer in Charge.
Supply & Fixing in repairs electronic ballast suitable for 1 X TLD,36 watt / 36 watt PLL, type EBP 136 TLD, 240 volts 50 / 60 Hz ; complete all as specified and directed by the Engineer in Charge.
Supply & Fixing in repairs energy saving new generation 10 Watt LED built up made up of Injection moulded Polycorbonate housing with high Quality Polycarbonate UV Protected Milky diffuser having CCT of 6500 K, THD<=15, CRI>=80, integrated electronic LED driver with APFC and 3.5 kv inbuilt surge protection with complete accessories and connection ; complete all as specified and directed by the Engineer in Charge.
Supply & Fixing in repairs security light fitting LED 25 Watt made up of pressure die cast aluminium housing and toughned glass having bottom opening separate driver with IP 66 Protection and Impact resistance of IK07, THD<=10%, Lumen output – 2700 Lm, CCT 6500 K, CRI>=70, with & including suitable size GI light grade pipe 1metre long bend to shape with MS clams,nut , bolts and accessories complete including connection with 3 core PVC insulated overall sheated with flexible cable multistrand copper conductor of size not less than 1.5sqmm from ceiling rose to connector to fitting terminal including taking down old security light fitting ; complete all as specified and directed by the Engineer in Charge.
Supply & Fixing in repairs fan regulator electronic step type (5 step) socket size and making all necessary connections complete all as specified and directed by the Engr-in-Charge.
Material & Labour in repairs earthing complete with galvanised earth plate electrode 600mm X 600mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 metres below ground level) with top edge of earth plate not less than 1.5metres below normal ground level, connected to galvanised earth lead wire 4mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No.3 of MES SSR 2009 , Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge,50mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150mm both ways center to center with suitable lifting handle to cover, earth pit made of PCC 1:3:6 type C-1, GI protection pipe light grade 15 mm bore up to 7.5metres length from earth electrode & engraving of earth marking on nearby building with cement mortar (1:4) plate size 200mm X 150mm X 15mm & painting of earth result etc. including testing ; complete all as specified and directed by the Engineer-in-Charge. Note : - (i) Earth lead and protection pipe beyond 7.5 m shall be measured and Paid separately. (ii) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
Supply & Fixing in repairs ceiling mounting fitting LED type 36 Watt fitted in 2 X 2 ceiling including PVC wire upto 1.5 mtr from ceiling rose to fitting complete all as specified and directed by Engineer in Charge.
Supply & Fixing in repairs 25 mm bore light grade galvanised iron tubing with all necessary GI fittings as in protection pipe of cable, fixed to pole or laid under floor / ground / under road crossings for protection of cable ; complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs 1100 volt grade heavy duty electric power cable 10 sqmm twin core PVC insulated Aluminium solid conductor screwed with inner seathing of PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1metre apart including 4 mm suspension wirewith & including drawn through 25mm dia PVC conduit heavy duty , fixed to walls / pols ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs of LED flood light 50 Watt having 6500 K, colour temperature made out of Die-Cast aluminium housing (Heat Sink), Silikon gasket and cable gland is used for cable entry, no harmful UV & IR radiation, 35000 burning hours life, IP 66, IK 07, 6KV surge protection, Lumen efficiency of LED >=140Lm/ W, having polycarbonate cover with intergrated lens, total system lumens = 5000 LM, CRI >70, and PF >0.95 ; complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs decorative LED 15 Watts Post Top IP-65, made up of die cast aluminium for mounting LED driver and spun aluminium canopy with high quality polycarbonate opal diffuser used over LED module, to provide glare free light and clear acrylic diffuser having CCT 3000K, CRI>=70, THD<=10%, and lumen output 1320 Lm having with built in potted electronic driver with APFC, 4 KV inbuilt with accessories ; complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs GI bracket 1.2 metres long, made of GI pipe medium grade of 40 mm dia, 2 x clamps made of Flat iron 40 mm x 6 mm Incl nuts,bolts & washers, painting, fixing on wall of the building/ pole complete all as specified and directed by the Engineer in Charge.
Supply & Fixing in repairs bell push, Modular type, single pole 5 amps , one module ; complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs LED Blub 9 Watt Pin type 220 Volts including connection ; complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repairs Ceiling light fitting 12 Watt as per sample including connection ; complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repairs LED Blub 9 Watt Thread type 220 Volts including connection ; complete all as specified and directed by Engineer-in-charge.
Material & Labour for binding of loose wire in any numbers /of any size by using cable ties and cable clips flexible PVC pipes and PVC casing and caping of suitable size as required on site . Note :- Flexible PVC pipe and casing and caping will be measured and paid separtely.
Supply & Fixing in repairs flexible pipe 25mm dia ; complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repairs flexible pipe 40mm dia ; complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repairs PVC Casing / Caping 25mm including connection ; complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repairs PVC Casing / Caping 20mm including connection ; complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repairs Hylam sheet 7" x 4" including screw complete all as specified and directed by the Engr-in-Charge.
Supply & Fixing in repairs Hylam sheet 9" x 11" including screw complete all as specified and directed by the Engr-in-Charge. Notes for Srl Item No.1 to 61 of BOQ (i) The above said work is based on daily complaint based work and Contractor has to take daily complaint from MES complaint cell from Concern JE E/M on Daily Basis (Except Sunday & holiday). (ii) Contrcator has to attend the complaint within 24 Hrs after recived complaint from JE E/M. (iii) Contrctor has to provide the Mobile number of their Engineer or supervisor to Concerned JE E/M so that massges of complaint can also be send on the same mobile number. (iv) For non collection of daily complaits from JE E/M Rs.500/- per day will be recovered from contractor's dues. (v) For Non attendence of complaints within 24 Hrs Rs.200/- per day per complaint will be recovered from contractor's dues. (vi) Contractor or of their Engineer or supervisor has to return the complaint duly signed from the user within time & date to JE EM . (vii) The make/manufacturer shall be approved by the GE before incorporation in the work as per Appendix 'B' to Particular specification section-II of tender.
Bharat Builder
B S TRADERS
kailu construction co
Harai Sharan Govt Contractor
UNITED ENGINEERING CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .