Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹12.6 L+₹1.1 L (9.61%)Rejected-Finance | L2 | Rejected-Finance Rejected being not lowest bidder | |
| 3 | L3₹12.9 L+₹1.4 L (12.4%)Rejected-Finance | L3 | Rejected-Finance Rejected being not lowest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected due to not found enlisted in required category as per NIT | |
| 5 | Rejected-Technical NAGPADA MUMBAI 10TH LANE KAMATHIPURA S P ROAD TELANG BLDG NO 23 ROOM NO 5 10TH LANE MUMBAI 400008 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | - | Rejected-Technical Rejected due to not found enlisted in required category as per NIT |
Tender Value
₹14.6 L
EMD Value
₹29,300
Closing Date
21 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
PROVN OF STANDBY HT ELECTRICAL CABLE FROM MAIN FEEDER PILLER AT TAKE OFF POLE AT KIRKEE TO TRG BN-I UNDER GE (CENTRAL) KIRKEE
2022_MES_529036_3
CWE/KKE/TOKEN-08 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KIRKEE
AS PER TENDER DOCUMENTS
5 documents required · 5 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹29,300
Yes
12 Aug 2022
4 Jul 2022
23 Jul 2022
4 Jul 2022
21 Jul 2022
8 Jul 2022
60 days
Amount
Excavation in trenches nexc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in hard/dense soil for laying cables, erection of poles complete all as specified and directed by Engr-in-Charge
Returning, filling including spreading, levelling, watering and ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed by Engr-in-Charge
Removing surplus excavated soil n-exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge
Supply, laying and testing in trenches or passing through pipe or duct , XLPE PVC insulated (heavy duty) galvanised steel strip or wire armoured electric cable 11000Volt (E) Grade with stranded aluminium conductor for cross sectional area 185 sqmm 3 core for passing the cable through duct complete all as specified and directed by Engr-in-Charge.
M&L Stone dust cushioning of thickness 18 cm for underground cable protection complete all as specified and directed by Engr-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover, Class HV duly embossed “11 KV”, type 1 with peak, size 300mm x 180mm x 40mm all as specified and directed
Supply and fixing cable route indicator for HT UG Cable of 11000 Volts 80 mm dia CI Plate marked on HT cable bolted with 40 x 5 mm flat iron member of height 0.4 mtr, embedded in PCC 1 : 3 : 6 type C2 of size 20 x 20 x 30 cm block complete all as specified and directed.
S&F Cable joining kit for 11 KV (Earthed) grade cable for Indoor end joint termination heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable suitable for 185 sqmm. Make: Raychem/Denson/M-Seal
S&F Cable joining kit for 11 KV (Earthed) grade cable for outdoor end joint termination heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cablesuitable for 185 sqmm. Make: Raychem/Denson/M-Seal
M&L for GI pipe light grade laying in trenches/ under floor/on walls for protection of UG cables all as specified and directed of size 100mm dia. Make: TATA /Parkash/ Surya/Jindal
Labour for cleaning of mud, sand, etc in duct passing through below the road between Depot Bn MRS and BEG Side complete all as specified and as directed by Engr In Charge
Supply , install, testing and commissioning of indoor 1 x IC, 1 x OG CPRI approved tested panel type vacuum circuit breaker for capacity 11 KV, 630 Amp, 3 Phase, 3 wire, 50 Hz, 26.3 kA for 1 sec breaking capacity, totally enclosed single bus bar for each phase, floor mounting, Draw out type,110V DC shunt tripping & closing coil, Inbuilt Anti-pumping feature, Spring charging motor rated 230V AC with Spring charge indicator, Auxiliary contacts: 6No+6NC, Automatic Safety shutters, Mechanicaly on/off push buttons, operation counters, True close door operation, Test/Service indication, Internal Arc flash tested Panel with accessories : Rack in rack out handle, Spring charge Handle, Trip Rod. incl all manufacturer's standard fitting and accessories of following specification all as specified and as directed by Engr-in-charge including necesarry civil work for VCB. Make:L&T (Cat No. (CDBBN311OOBN1D)/Simens/ Crompton Greeves/ABB/Schneider
A) Specification for VCB (i) Bus bar chamber with 3 phase copper bus bar of suitable rating duly insulated - 01 set ( set of three). (ii) Electrical trip coil 110 V DC - 1 No (iii) Electrical shunt coil 110 V DC – 01 No iv) CT Chamber incorporating 3 Nos single phase rasin cast current transformer ratio 150/1A- class 1.0, 15VA for metering & class 5P10, 15VA for protection and burdon -3 Nos Make: (ECS/Pragati/NPTL/Saviour) (v) 3 Phase, potential transformer, ratio 11KV/√3/110V/√3 AC Core1: CL 1.0, 50VA and Core 2: CL 3P, 50 VA fixed type - 03 No. Make: (ECS/Pragati/NPTL/Saviour)
(vi) Three phase over current (O/C) and One earth fault (E/F) relay digital numerical Communicale Non-Directional with protection (50,50N,51,51N) and Aux. Voltage 110V DC - 01 No Make: (Avana/Ashida/C&S) (vii) Three phase Over Voltage and under Voltage realy with protection (27,59) and Aux Voltage 110V DC -01 No Make:(Avana/Ashida/C&S) (viii) Aux relay for Transformer Protection with protection (63) Aux. Voltage 110 DC- 02 No Make:(Avana/Ashida/C&S) (ix) Master Trip relay with protection (86) and Aux voltage 110 DC-01 No Make:(Avana/Ashida/C&S) (x) Trip Circuit Supervision relay with protection (95) and aix Voltage 110 DC - 01 No Make:(Avana/Ashida/C&S) (xi) Digital Multifunction Meter for amps, volts, KW, KVA, KVAR, and PF type - 01 No Make: L&T/Secure
(xii) Plug and Socket 5/15Amps - 01Nos Make:Anchor/Havells (xiii) Power Pack unit, I/C 230V AC,O/G:110V DC-01 No (xiv) Thermosate- 1 Nos (xv) Space heater- 2 Nos (xvi ) Emergency Push Button - 1 No Make:Teknic (xvii) Indicating lamp - 8 No Make: teknic/L&T (xviii) 8 window Annunciator. Make: Alan/Minilec (xix) Hooter - 01 No Make: Alan/Minilec (xx) L/R Switch- 01 Make:Salzer/Teknic (xxi) TNC Switch, Pistol grip handle, Spring return to neutral -01 No Make:Salzer/Teknic
(xxii) Door Limit Switch 2A, Push to Off - 01 No Make:Salzer/Teknic (xxiii) DC Control Contractor-110V DC- 02 Nos. Make: L&T (xxiv) 16A DP MCB -01 No Make: L&T (xxv) 6A DP MCB- 5 No Make : L&T (xxvi) 2A P MCB- 02 Nos Make: L&T
(xxvii) Fabrication with Powder Coating including Wires and Electrolytic grade Al. Bus Bar and Miscellaneous Items - One Job (xxviii) All internal wiring should be FRLSH of suitable size recommended by OEM (xxiv) Contractor has to submit 5 years warranty for VCB and one year warranty for panel
Supply, fix and laying of DWC pipe of size 120/103mm dia including passing the HT 11KV Cable of size 185 sqmm 3 Core through the DWC pipe all as per direction of Engr-in-Charge.
Suplly install ,testing and commissioning of Battery bank unit having input voltage 215-250 and out put voltage 30 to 110 Volt DC Supply for operating of 5 Nos of VCB rating 630 Amps including connections with backup 6 Hrs all as per specified and directed by Engr-in-Charge.
M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 mtr long buried directly and vertically in ground with top edge not less than 1.25 mtr below ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised steel earthing strip of 32x6 mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2 with pit cover, funnel, wiremesh, 32 mm dia light grade GI tubing for protection of GI strip 32x6 mm, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
MANGAL ELECTRICAL STORES
Techmat trading solution
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .