Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹97.1 LAccepted-AOC | 1 | Accepted-AOC Being the Lowest one | |
| 2 | 2₹97.6 L+₹49,300 (0.51%)Rejected-AOC | 2 | Rejected-AOC Being not the lowest one | |
| 3 | 3₹98.1 L+₹98,600 (1.02%)Rejected-AOC | 3 | Rejected-AOC Being not the lowest one | |
| 4 | 4₹1.0 Cr+₹5.6 L (5.75%)Rejected-AOC | 4 | Rejected-AOC Being not the lowest one |
Tender Value
₹92.9 L
EMD Value
₹1.9 L
Closing Date
23 Jun 2022, 5:00 pmClosed
Er Pardeep Singh Kataria
Executive Engineer, BC and Township Division, BBMB, Nangal Township
Providing additional toilet in B-Type quarters at Nangal Township
2022_BBMB_85949_1
722/22/TS
Open Tender
Civil Works
Tender cum Auction
365 days
Nangal Township
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
₹1.9 L
17 Jan 2023
21 May 2022
24 Jun 2022
21 May 2022
23 Jun 2022
21 May 2022
Amount
PART-I (CIVIL ITEMS)
Dismantling brick work tile masonry or tile lining in mud with jibi face (CSR item Ref No. =8.5 (e))
Dismantling concrete or precast concrete reinforced cement concrete. (CSR item Ref No. =8.6 (e))
Scraping of bricks dismantled from bricks works in lime or cement. (CSR item Ref No. =8.31 ( e ))
Removing & Re-fixing of window as per the directions of engineer-in-charge. (AOR)
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres (CSR item Ref No. =6.6)
Cement concrete 1:6:12 with stone aggregate 40 mm gauge (ii) mixing by mechanical means using concrete mixer volumetric type. (CSR item Ref No. =10.8 (b)(ii))
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (Old & used bricks to be supplied by departmentally) based on CSR item 11.3 (i) (AOR)
Damp proof course 4 cm thick of cement concrete 1: 2: 4 with two coats of bitumen 20/30 penetration @ 1.65 kg per sqm laid hot and sanded. (CSR item Ref No. =10.26)
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 meters above plinth level. (Old & used bricks to be supplied by departmentally) based on CSR item no. 11.4 (i) (AOR)
115 mm thick brick wall laid in cement sand mortar 1:4 without reinforcement in super structure (CSR item Ref No. =11.36)
Centering and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels (CSR item Ref No. =9.6)
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. (CSR item Ref No. =9.8)
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. a) Size 75mmx75mm ( jointing RCC Slab with wall) (CSR item Ref No. =30.85 (a))
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. (CSR item Ref No. =10.20)
Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete (CSR item Ref No. =18.18)
Terracing consisting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc. (CSR item Ref No. =13.13 (i))
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. (CSR item Ref No. =13.55)
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. (CSR item Ref No. =13.45)
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (CSR item Ref No. =13.74)
Providing and fixing 110 mm dia U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge (a) upvc 110mm bend (CSR item Ref No. =13.75 (a))
Providing & fixing in position MS or heavy flat iron clamps made out of MS flat iron of the approved design for fixing UPVC pipes to walls compete in all respects (MR)
Plastering on under side of ceiling 10 mm thick cement plaster 1:4 (CSR item Ref No. =15.44)
12.5mm thick cement plaster 1:6 (CSR item Ref No. =15.11)
20mm thick cement plaster 1:6 in two coats work (CSR item Ref No. =15.28)
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm fine sand filling using machinecal mixxer for mixing of material (CSR item Ref No. =14.3)
Providing and laying Anti-skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. white cement slurry in joints including corners angles and beading. (CSR item Ref No. =14.72)
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/ Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (CSR item Ref No. =14.127)
Cement concrete 1:2:4 (ii) mixing by mechanical means using concrete mixer volumetric type (CSR item Ref No. =10.13 (ii))
Providing and fixing M.S. angle iron 40x40x6mm chowkat including iron hold fasts butt hinges fixed in position, finished with red lead non-setting primer complete in all respect a) For single rebate (CSR item Ref No. =18.29 (a))
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and panelling to be paid for separately) (a) For fixed in position & chowkhat (CSR item Ref No. =17.45 (a))
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and panelling to be paid for separately) (b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required. (CSR item Ref No. =17.45 (b))
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) Float glass panes of 5.5 mm thickness (CSR item Ref No. =17.47 (i))
Extra for Glazing frosting of glass (MR)
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless , stopper and screw etc. for these fittings (Excluding sliding bolt) (ii) For shutter area above 0.50 sqm (CSR item Ref No. =17.23 (ii))
Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250mmx16mm (CSR item Ref No. =17.49 B)
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35 mm thick (CSR item Ref No. =17.27 (A) (iv))
Providing and fixing 0.50mm thick aluminium sheet including cost of necessary fittings i.e. screws, etc. complete (CSR item Ref No. =17.44)
Providing & fixing L-iron (40x40x6mm) ventilator with wire gauge on it and 3mm thick flat iron 12.50mm width complete in all respect (AOR)
Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of Paris and chalk mitti including finishing the surface to the required finish complete. (CSR item Ref No. =16.6)
Distempering with Acrylic washable oil distemper (of approved manufacture) two or more coats over one priming coat to give an even shade (CSR item Ref No. =16.10)
Finishing walls with cement based paint water soluble exterior paint such as snowcem, robbiacem etc. two coats to give an even shade. (CSR item Ref No. =16.14)
Applying priming coat with metal primer on new steel or iron work including preparation of surface. (CSR item Ref No. =16.20)
Applying pink primer or aluminium priming coat on wood work including preparation of surface knotting and stopping etc. (CSR item Ref No. =16.16)
Painting two or more coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work. (CSR item Ref No. =16.21)
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. (CSR item Ref No. =16.17)
Carriage of Bricks lead 1 km including loading & unloading by manual means. (CSR item Ref No. =5.2 (vi) & 4.3)
Carriage of Bricks Bats lead 1 km including loading & unloading. (CSR item Ref No. =5.2 (i) & 4.1 A)
PART-B (WATTER SUPPLY ITEMS)
Excavation manually in trenches with straight or open cutting in built up street/lane having wall to wall width of straight/ lane upto 30.0 meter, for intramural sullage drains, extramural intercepting drains and outfall drains, storm water channels and other work contingent or incident thereto , to full dimensions and depth as shown on the drawings or as shall be required by engineer- in – charge including dressing to correct sections and dimensions according to templates and levels, dewatering of rain water, diversion of traffic, providing and fixing and maintenance of caution boards, fencing, night signals, for leads upto 15 m and for all the lifts and subsequent refilling, watering and dressing upto ground level, including removal of surplus spoil from the site upto 15meter distance complete in all respect a) For Ordinary gravel soil having gravel upto 40% (CSR item Ref No. =29.1 A (ii))
Cement concrete 1:8:16 (b) with stone aggregate 20 mm gauge (ii) mixing by mechanical means using concrete mixer volumetric type (CSR item Ref No. =10.7 (b) ii)
Providing, lowering, cutting & jointing salt glazed stone ware pipes and specials ISI marked as per IS: 651-2007 class 5p-1 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the supporting benching, hunching and envelopes are completed including jointing of pipes and specials in trenches, using cement sand mortar 1:1 and best spun jute yarn as per IS:1887, finishing and trowelling of each joint at an angle of 45 degree with the longitudinal axes of pipe watering, keeping the joint covered and wetted till the same are curd testing the sewerage line of leakage and defects good as laid in the contract specification and chipping and finish the cut surface to uniform finish to the entire b) 150mm i/d pipe (CSR item Ref No. =29.41 (b))
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. (B) Single Socket Type B (a) 110mm o/d SWR UPVC pipe lines laid complete (CSR item Ref No. =30.74 (iii) B (b))
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. (B) Single Socket Type B (c) 90 mm o/d SWR UPVC pipe lines laid complete (CSR item Ref No. =30.74 (iii) B (c ))
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. for 110 mm o/d pipe (i) vent Cowls (CSR item Ref No. =30.81 (iii) B (vi))
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. for 110 mm o/d pipe (ii) Coupler (CSR item Ref No. =30.81 (iii) (B) (viii))
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. for 110 mm o/d pipe (iii) Elbow 90 Degree (All side socketed) (CSR item Ref No. =30.81 (iii) B (v))
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. for 110 mm o/d pipe (iv) P Trap/Floor Trap 110mm x 75mm (CSR item Ref No. =30.81 (iii) B (x))
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. for 90 mm o/d pipe (iv) Coupler (Description changed) (CSR item Ref No. =30.81 (iii) (C) (viii))
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300 mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. (b) 100mm internal Diametre H.C.I. gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm (CSR item Ref No. =30.99 (b))
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) (b) 110mm o/d (CSR item Ref No. =30.77 (C) (b))
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) (c) 90 mm o/d (CSR item Ref No. =30.77 C (c ))
Providing and fixing in position M.S. or heavy flat iron clamps made out of M.S. flat iron of the approved design for fixing SWR UPVC, vent or antisyphonage pipes to walls complete in all respect. Including cutting and making good the walls and floors etc. and painting.(a) M.S. holder bats clamps for 110 mm o/d SWR UPVC pipes (CSR item Ref No. =MR)
Providing, laying, jointing , fixing and testing ISI marked G.I. pipe (as per IS 1239) B-class premium make such (Jindal Hisar) including cost of specials (such as tees, bends, sockets, elbows etc.) painting with anti-corrosive bitumastic paint, testing, cutting, threading inside building complete. (a) 15 mm i/d (CSR item Ref No. =28.35 (a))
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I. pipes line and making good the same to its original condition. a) Size 75mmx75mm (CSR item Ref No. =30.85 (a))
Providing and placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer-in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fittings and base support for tank. i) Double layer Tanks (CSR item Ref No. =30.97-A (i))
Providing and fixing in position automatic brass ball cock in tanks. b) Brass Ball cock with rod and Plastic i) 15 mm i/d (CSR item Ref No. =30.96 (b) (i))
Providing and placing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC water storage tanks complete in all respect. a) G.I. tank nipple 15mm i/d (CSR item Ref No. =30.98 (a))
Providing & fixing in position 15mm i/dia bib cock of approved make to the approval of the EIC complete in all respect. (a) C.P. brass Bib cock foam flow without flange (CSR item Ref No. =30.65 A (ii))
Providing & fixing in position 15mm i/dia bib cock of approved make to the approval of the EIC complete in all respect. (b) Brass bib cock/stop cock 15 mmx400grm (CSR item Ref No. =30.65 A (iv))
Providing and fixing in position stop cock/ Angle valve of approved make ( to the approval of Engineer-in-charge) complete in all respect. a) C.P. brass 15mm Concealed stop cock with flange (CSR item Ref No. =30.66 (b))
Providing, fixing and jointing G.I. Union couplings (of approval make with the approval EIC) as per IS 1879 in G.I. pipe lines complete in all respect. a) 15 mm i/d G.I Union (CSR item Ref No. =28.40 (a))
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. ii) Size 550mmx400mm (CSR item Ref No. =30.32 (ii))
Providing and fixing PVC waste pipe 32mm collapriable complete in all respect. (CSR item Ref No. =30.20)
Providing and fixing in position chinaware European type water closet with P trap or S trap size of approved make (to the approval of the Engineer-in-charge) consisting of 10 Letter. PVC flushing cistern ISI marked, PVC short bend 32mm die including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge (CSR item Ref No. =30.4)
Providing and fixing jet spray with 2’-6” long PVC pipe. a) With C.P brass nut (CSR item Ref No. =30.8 (a))
Providing and fixing in position PVC flexible tube connection of approved make ( to the approval of Engineer-in-charge) complete in all resprct. ( b) PVC tube connection of size 15mmx450mm with C.P. Brass nut. (CSR item Ref No. =30.72 (b))
Providing and fixing in position C.P. brass overhead shower 1 flow with shower arm with 15mm i/d inlet of approved make (to the approval of Engineer-in-charge) complete in all respect. (CSR item Ref No. =30.56 A)
Providing and fixing in position Looking mirror commercial quality (to the approval of Engineer-in-charge) complete in all respect. (MR)
Providing and fixing in position S.S. grating with frame of approved make (to the approval of Engineer-in-charge) complete in all respect. (CSR item Ref No. =30.80)
Providing and fixing in position towel rail/ ring of approved make (to the approval of Engineer-in-charge) fixed in with crawl plugs embedded in walls with brass screws complete in all respect. (b) C.P. Brass towel ring (CSR item Ref No. =30.58 (b))
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 (150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. a) Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal (CSR item Ref No. =29.60 (a))
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 (150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. (b) Size 450mm x600mm inside with 455mm x610mm cover and frame light duty double seal (CSR item Ref No. =29.60 (b))
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floor with cement concrete 1:2:4 mix (1 cement :2 concrete sand : 4 : graded stone aggregate 20mm nominal size) cement plastered on both side with cement mortar 1:2 (1cement : 2 coarse sand ) finished with a floating coat of neat cement and making necessary channals for the drain etc. complete. (a) For pipes 100 to 250mm Diameter (CSR item Ref No. =29.65 (a))
PART-III (ELECTRICAL ITEMS)
RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts (socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- (i) Wiring light point (CSR item Ref No. =34.04 (ii))
RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts (socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- (ii) Wiring 6 Amp. wall socket point (CSR item Ref No. =33.04 (iv))
RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts (socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- (iii) Wiring 16/20 amp. power plug control point (CSR item Ref No. =34.04 (vi))
PVC INSULATED SINGLE CORE FRLS COPPER CONDUCTOR CABLE:- Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- (i) Overall size 4 sq.mm (Un-sheathed) (CSR item Ref No. =34.09 (iv))
PVC INSULATED SINGLE CORE FRLS COPPER CONDUCTOR CABLE:- Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- (ii) Overall size 1.5 sq.mm (Un-sheathed) (CSR item Ref No. =34.09 (ii))
Bidder Name
Amount in Words
VINOD KUMAR SHARMA
SUBASH CHAND
SUDHIR ANAND
Sardari Lal Contractor
SUBASH CHAND
Sardari Lal Contractor
VINOD KUMAR SHARMA
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .