Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52.4 CrAccepted-AOC | ₹52.4 Cr Quoted ₹52.2 Cr | L1 | Accepted-AOC Qualified L1 - AOC |
| 2 | L2₹52.2 CrRejected-Finance OFFICE NO 515 PLOT NO 194 NMS ICON SECTOR 19 ULWE NAVI MUMBAI MAHARASHTRA 410206 | NAVI MUMBAI | THANE | MAHARASHTRA | 410206 | ₹52.2 Cr | L2 | Rejected-Finance Not L1 |
| 3 | L3₹52.4 CrRejected-Finance THIRD FLOOR AMIT CRYSTAL SENAPATI BAPAT ROAD PUNE 411 016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹52.4 Cr | L3 | Rejected-Finance Not L1 |
| 4 | L4₹53.8 CrRejected-Finance 503 4 BHOSALE DYNASTY SHITOLE NAGAR OLD SANGVI PUNE 411027 | PUNE | PUNE | MAHARASHTRA | 411027 | ₹53.8 Cr | L4 | Rejected-Finance Not L1 |
| 5 | Not Admitted-Fee/PreQual/Technical S NO 280 2 A GALO NO 1 2 3 PLOT NO 358 2 MANIK ELITE BARAMATI DIST PUNE 413102 | PUNE | MAHARASHTRA | 413102 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹50.3 Cr
EMD Value
₹25.1 L
Closing Date
6 Aug 2024, 6:55 pmClosed
Executive Engineer, Public Works Division, Pune 1.
Executive Engineer, Public Works Division, Pune 1., Central Building Campus, Pune 411001
14-1 - Construction of New S.P. (Rural) Office Building at Pashan Road, Chavan Nagar, Pune. (Including Electrical Work)
2024_PWDRP_1057482_1
E-Tender Notice No. 14 for 2024-2025
Open Tender
Civil Works - Buildings
730 days
Pashan
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
₹25.1 L
Chief Engineer, Public Work Region, Pune.
24 Jun 2025
23 Jul 2024
9 Aug 2024
23 Jul 2024
6 Aug 2024
23 Jul 2024
30 Jul 2024
Amount
CIVIL WORK - Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming , watering including shoring and strutting etc. complete. (For all leads and lifts) By Mechanical Means
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming , watering including shoring and strutting etc. complete. (Lift upto 1.50 metre) By Mechanical Means
Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming , watering including shoring and strutting etc. complete. (Lift upto 1.50 metre).) By Mechanical Means
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming , watering including shoring and strutting etc. complete (lift upto 1.5 metre) By Mechanical Means
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5 metre To 3.0 metre) By Mechanical Means
Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 3.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per squaremetre of surface area covering ten years guarantee on bond paper. Stilt Floor
Filling in plinth and floors with approved excavated material in 15 centimetre . to 20 centimetre . Layers including watering and compacting etc. complete. Stilt Floor
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 centimetre to 20 centimetre including watering and compaction etc. complete. Stilt Floor
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete.(LABOUR RATE ONLY) Stilt Floor
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete.
Smart Care Preapply HDPE 80 for Raft and Uncofined Retaining Walls 1- Supplying and Installing of Asian Paints Smarteare 1.20 millimetre thick pro applied HDPE fully bonded membrane or equivalent make having puncture resistance of HOON as per ASIMI 154), tensile strength of 21 Mpa, and hydrostatic head resistance not less than zom water head as per ASTM D 545 elongation of 500% as per ASTM D412, peel adhesion to concrete of 1200 N/m as per ASTM D 901, Lap peel adhesion 450N/m as per ASTM D1876. The size of the membrane should be 1.2 metre x 20 metre. The pre-applied, fully bonded HDPE sheet membrane shall be loosely laid on Plain cement concrete and gets bonded to the underneath of the poured concrete of base/ raft slab and confined retaining wall. The fully bonded HDPE sheet membrane shall consist of a high performance PE film, self adhesive polymer layer and unique particulate layer with pressure sensitive adhesive, which bonds fully to the poured concrete of base slab/confined retaining wall. The membrane shall have minimum of 75 millimetre side laps and end laps which shall be sealed with double sided adhesive tape, plc complete as per manufactures specification and Instructions. This shall include cleaning & removal of all the dust, dirt, oll, grease, coment laltance, loose particle & prepare the P.cement concrete Substrate for laying of waterproofing system, as directed by Engineer Incharge and covering 10 years Guarantee against leakages on Court fee stamp paper of Rs. 500/- etc. complete. Stilt Floor
Smart Care Ultron (Hybrid Polyurea) for Retaining Walls -Providing and laying liquid based Asian Paints Smartcare Ultron or equivalent make (Polyurea-Polyurethane seamless/jointless treatment) for waterproofing on the Un-confined vertical surface by cleaning the external surface, removal of loose concrete and filling cracks with polymer modified mortar & treatment of tie rod holes, bracing angle etc with plugging mortar, as per manufacturers' recommendation , thereafter, providing & applying one coat of two component solvent free epoxy primer @ 0.15-0.20 kilogramme /m2, followed by providing & applying 2 component high performance hybrid polyurea elastomeric waterproofing coating cold applied of spray / brush applied, liquid membrane with an elongation of 600% and tensile strength of 12.6 N/ millimetre 2 as per ASTM D 2370, crack bridging ability of 3 millimetre as per ASTM C1305, shore A Hardness of min. 75 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying in two coats at 1.5 kilogramme per Sqm etc, complete as per Manufacturer specifications. HDPE Termination at Raft with Aluminium strip of width min. 75 millimetre , with the turnkey execution to be done by the manufacturer through its in house subsidiary execution company and as directed by Engineer incharge with covering 10 years Guarantee against leakages on Court fee stamp paper of Rs. 500/- etc. complete. Stilt Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor basedProgrammable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Stilt Floor
Providing and laying in situ /Ready Mix cement concrete M-20 of trap metal for Reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced cement concrete columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor basedProgrammable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap metal for Reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced cement concrete columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor basedProgrammable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Stilt Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap metal for Reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced cement concrete columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Stilt Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap metal for Reinforced cement concrete columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor basedProgrammable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Stilt Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap metal for Reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC without SCAD Aenabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap metal for Reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor basedProgrammable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap metal for Reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Stilt Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap metal for Reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor basedProgrammable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap metal for Reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Stilt Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap metal for Reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap metal for Reinforced cement concrete Chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Stilt Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap metal for Reinforced cement concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Stilt Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap metal for Reinforced cement concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap metal for Reinforced cement concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap metal for Reinforced cement concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap metal for Reinforced cement concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing in position Thermo Mechanically Treated (TMT) - FE - 500 bar reinforcement of various diameters for Reinforced cement concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and applying external mineral cement plaster with natural concrete & stone look of KEMTEX - ARAVA SERIES as detailed below i) Using a trowel, apply an initial coat of 1-3 millimetre (depending on substrate), flatten, and smooth out the coat in a uniform manner.Leave 24 hour to dry. ii) Using a trowel,apply a second coat approximately 1.5 millimetre . Remove any excess to receive a uniform coating and wait for it to partially dry.For the best result, the material should be slightly moist before the final application.To Receive a smooth appearance, work with a trowel at 45 degree angle to smooth out and compress the material. For a cloudy - coarse appearance, gently tap the surface with a moist spongein a circular motion (take care to remove any excess moisture ) iii) Wait 24 hours (depending on the thickness of the coa) for final drying. iv) For additional protection agaisnt moisture absorption and water penetration. Nano sealer 755 or a transferant Aqua top Protective coating (that block out water vapor) can be applied, either by spray with a roller. This protective layer should be applied 14days after completing the application of the ARAVA Coat etc complete as per directed by Engineer Incharge. Stilt Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing internal / external 20 millimetre thick Ready Mix plaster confirming to IS:4031(Part-4) 1988 and IS 383- 1970 in a single coat using Cement mortar of proportion 1:4 containing special type of polymer additives about 0.4%, to all type of surfaces in all positions including scaffolding and curing complete Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetre thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and applying gypsum plaster ( with Gypsum material) with finishing with gypsum material in 10 to 13 millimetre thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing internal cement plaster 12 millimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Stilt Floor
Providing and applying a base coat comprising of 1 Kilogramme Polydee-MC and 1 kilogramme fresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A : 1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete. Stilt Floor
Fourth floor
Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. Stilt Floor
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre . width at the junction of Reinforced cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / burnt brick masonry and or tying by binding wire etc. complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC‘s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 kilogramme /15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Stilt Floor
Providing and fixing mild steel grill work for windows, ventilators, etc. 15 kilogramme /Square Metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. Stilt Floor
Providing and applying Apcolite All Protek matt finish (Asian apaint or equivalent make) revolutionary water based paint of approved shade for internal wall surfaces as detailed below i) Sand the surface with sand paper 180 and wipe clean. Ii) Apply decoprime cement primer with mineral water with brush 50% and roller 60% and allow dry for 4 to 6 hour iii) apply acrylic wall putty with addition of water as per requirement with the help of putty knife and allow dry for 4 to 6 hour. iv) Then sand the surface with sand paper 180 and wipe clean v)Apply decoprime cement primer with mineral water with brush 50% and roller 60% and allow dry for 4 to 6 hour vi) Then sand the surface with sand paper 180 and wipe clean vii) Apply first coat of APCOLITE All Protek with addiion of mineral water with brush 30% and roller 40% and allow dry for 4 hour. viii)Apply second coat of APCOLITE All Protek with addiion of mineral water with brush 30% and roller 40% and allow dry for 4 hour.etc complete as per directed by Engineer Incharge. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (HeatReflective Paint). Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. Stilt Floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Stilt Floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar 1:3 admixed with approved water proofing compound and finally top finishing with average 20 millimetre . thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 millimetre x 300 millimetre . making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Stilt Floor
Fourth floor
Providing waterproofing in Water closet and bath including brick bat coba in all position including providing and laying 12 millimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in centimetre 1:5 with waterproofing compound 1 kilogramme /bag of cement grouting and finishing the top layer with 20 millimetre thick brick bedding in centimetre mortor 1:3 with waterproofing compound 1 kilogramme /per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing water proof bedding for flooring of Bath and Water closet 25 millimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. Ground floor
Providing and laying vitrified matt fininsh tiles having size 590 millimetre to 605 millimetre x to 605 millimetre of 8 to 10 millimetre thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, fillingjoints, curing and cleaning etc. complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and laying vitrified matt finish tiles having size 590 millimetre to 605 millimetre x to 605 millimetre of 8 to 10 millimetre thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 millimetre to 20 millimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in cement mortar 1:3 curing and cleaning etc. complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing machine cut machine polished 18 millimetre to 20 millimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 millimetre thick for door frame/ dado/ window boxing etc. On cement mortar 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and laying machine cut machine Polished Kota stone flooring 25 millimetre to 30 millimetre thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 millimetre to 30 millimetre thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Solid Core Flush door Single leaf Providing and fixing factory made solid core flush door in single leaf 35 millimetre thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face Laminate on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) commercial Hard Wood shutter Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Solid Core Flush door Double leaf Providing and fixing factory made solid core flush door shutters in double leaves 35 millimetre thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 – 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) commercial Hard Wood shutter Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat having size 65 x 150 millimetre comprising of virgin Poly vinyl chloride polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying Poly vinyl chloride solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kilogramme / cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/ millimetre 2, modulus of elasticity 900 N/ millimetre 2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Fourth floor
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35 millimetre thickness of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kilogramme /cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/ millimetre 2, modulus of elasticity 850 N/ millimetre 2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) Fourth floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimetre x 450 millimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimetre thick supports with kadappah top 35 to 40 millimetre thick and polished granite 16 to 20 millimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 metre x 0.60 metre and height is 0.75 metre) Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing machine cut mirror polished 18 millimetre to 20 millimetre thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and Fixing 50 millimetre thick sliding folding door 25X50 aluminum door profile for shutters wrapped with 12 millimetre thick ply finished with 4 millimetre thick veneer on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary necessary matt finish stainless steel fixtures fastenings, finishing with french-polish/ waxing and door lock and other hardware with Hafele make complete. (without door frame) etc complete as per directed by Engineer In charge.(including all leads and lifts) Ground floor
Stilt Floor
a) Door Frame: Supplying & Fixing frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 kilogramme /cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70 millimetre spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10 millimetre x 4 millimetre affixed in the slit of the Frame for fire and smoke sealing, etc. complete." Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
b)Shutter : Supplying & Fixing of 55 millimetre thick asbestos free 'TUFWUD' brand - 3 criteria checked - fire, heat and smoke resistant composite Fire check Door Shutter complying with with fire performance - FD 120 as per IS:3614 (part - II) comprising of 2x8 millimetre Calcium Silicate boards over Chemically treated (with Fire retardant chemicals in vaccum pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141) internal timber (Malaysian Hard Wood, densified to 810 kilogramme /cum) frame work of 100x32 millimetre with 32 millimetre thick infill of ceramic fiber (density 128 kilogramme /cum), vermaculite mix faced with 3 millimetre Fire retardant High Density fibre board, internally lipped with hardwood beading and pasted in Hydraulic Press under 25 MPa, spray quoted with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush- Type intumescent strip of size 10 millimetre x4 millimetre affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 millimetre x 40 millimetre x 5 millimetre with oil painting, etc. complete Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and applying french polish to new wood work, for required finishing including. knotting, preparing the surfaces, scaffolding etc. complete as directed. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimetre x 1.22 millimetre box type, 5 millimetre thick sheet glass louvers, of approved quality etc. complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Two Track Two Glass Shutter Window : Providing and fixing aluminium color anodized system sliding window of various sizes. Window will be made from YKKAP/ FENESTA/ MALWIN/ UTILITY, 25 to 27 millimetre slim series or equivalent System. Windows will be of specially extruded aluminium 2 Track - 2 Glass shutter window/ ventilator, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202 screws. Glass shutter will be made from specially extruded aluminium section, glass considered is 5 millimetre clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joint. All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single point self pressing lock. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Three Track Three Glass Shutter Window :Providing and fixing aluminium system color anodized sliding window of various sizes. Window will be made from YKKAP/ FENESTA/ MALWIN/ UTILITY 25 to 27 millimetre slim series or equivalent System. Windows will be of specially extruded aluminium 3Track - 3 Glass shutter, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202 screws. Glass shutter will be made from specially extruded aluminium section, glass considered is 5 millimetre clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joint. All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single point self pressing lock. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. complete. Ground floor
First floor
Second floor
Third floor
Fourth floor
Alluminium System colour anodized Fixed window - Providing and fixng alluminium system colour anodized fixed window of various sizes.Casement will be made from YKKAP/ FENESTA/ MALWIN/ UTILITY,40 millimetre series or equivalent system window will be of specially extruded alluminium section,joints will be of 45 degree joints,joints will be fixed with specially developed clits.Track frame will be fixed to the masnory opening of windows with S S 202 wood screws.Fixed glass casement will be made from specially extruded alluminium section,glass considered is 5 millimetre clear toughned glass. All shutter will be having 45 degree joints,joints will be fixed fixed with specially developed clits to form uniform hairline joints.All fixing screws will be of SS 202 windows will be sealed with weather sealant from outer periphery etc complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15 millimetre Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20 millimetre , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated galvanised iron channel on XL2 Clip having a web height of 32 millimetre with 15 millimetre wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 millimetre and 600 millimetre Cross Tees with a web height of 32 millimetre and a load carrying capacity of 7.7 kilogramme s/M2 and minimum pull out strength of 100 kilogramme s.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and Fixing Soft Fibre Acoustical Suspended Ceiling System with Optra (Bevelled Tegular) Edge Tiles of size 15 millimetre Exposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ?85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15 millimetre , suitable for Green Building application, with Recycled content of 66% GW and 74% RW. The tile shall be laid on precoated G.I channel 32 with 15 millimetre wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 millimetre and 600 millimetre Cross Tees with a web height of 32 millimetre and a load carrying capacity of 7 kilogramme per square metre with a minimum pull out strength of 100 kilogramme s. The T Sections have a Galvanizing of 90 grams per square metre and need to be installed with Suspension system The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Ground floor
Fourth floor
Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600 millimetre Lay in tiles of pre coated galvanized steel in 0.5 millimetre thickness in Global white color tile to be laid on grid systems with 15 millimetre wide T - section flanges color white having rotary stitching on the Main Runner, 1200 millimetre and 600 millimetre Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600 millimetre Lay in tiles of pre coated galvanized steel in 0.5 millimetre thickness in Global white color tile to be laid on grid systems with 15 millimetre wide T - section flanges color white having rotary stitching on the Main Runner, 1200 millimetre and 600 millimetre Cross Tees.products approved as per GRIHA and BS 476 etc. complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing in position Gypsum board false ceiling with 12.5 millimetre thick Gypsum boards, screwed/fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 millimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Supply, fixing and installation of 4 millimetre thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 millimetre thick, total thickness of aluminium composite panels not to be less than 4 millimetre , the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 millimetre X25 millimetre X 3 millimetre thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 millimetre X 1200 millimetre and fixed to the building structure as per design through 50 millimetre X50 millimetre X5 millimetre MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. Second floor
Third floor
METAL FALSE CEILING WITHOUT SUSPENSION SUPPORT FROM TRUE CEILING: Providing & fixing horizontal level suspended metal ceilings comprising of Metalworks F-H 600 Hook-on corridor system manufactured by Armstrong Ceiling Solutions with Rectangular panels made of 0.7 millimetre thick Galvanised Steel (GI) of 120gsm, post coated to Global White colour, suitable for Interior applications and architectural finishes, double grid concealed system and butt joint panels. The panel width shall be 300 millimetre , length ranging from 1500 millimetre to 2660 millimetre . General Specifications:Entire system to be designed for Interior applications, and concealed Grid, Butt joint panels. Panel Specifications: Material: The F-H 600 rectangular Hook-on panels to be made of galvanized steel (GI) of minimum 120gsm hot dipped galvanization (both sides included) as per IS 277 (2003), zero or minimum spangled, in minimum base material thickness of 0.7 millimetre as per in IS:513 (1994). Dimensions: The panel Length varies between 1500 millimetre to 2660 millimetre , panel Width shall be 300 millimetre . The dimensional tolerances for length shall be ±1.0m up to 1000 millimetre L; ±1.5 millimetre between 1001 to 2000 millimetre L; ±2.0 millimetre between 2001 to 3000 millimetre L. The dimensional tolerances for width shall be ±0.5m up to 300 millimetre W. Dimensional Tolerances for panel Thickness / panel width / panel length - to be measured in accordance with TAIM standards. Edge detail: the panels shall ha+A3ve Square Edge, with a 3 millimetre (W) x 8 millimetre (H) black foam gasket glued at the edges, typically on one long and one short side. All adjacent panels shall touch each other forming a butt joint and concealed grid visuals. Upturns: The short side of the panel shall have vertical upturns of minimum 30 millimetre (H) and shall be bent appropriately bent as per the manufacturer‘s specifications for providing hook-on ends. The long side shall have inside horizontal bends of 5-15 millimetre for rigidity and vertical upturns of 40 millimetre (for length ranging from 1251-2660 millimetre ). Surface Finish: Plain: The panels shall be in plain unperforated finish (without any acoustical backing / felt). Colour and finishes: The panel surface shall be electrostatically powder coated (post coat) on visible side after mechanical production, using RoHS compliant powder, to achieve coating thickness ranging from 60-80µ and architectural quality finish. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017, 250 hours of condensation test (as per DIN 50017 or DIN EN ISO 6270-1 Norms), UV resistance of 500 hours and 50% gloss retention (as per ASTM G 154 UVB-313 Norms). The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E (∆e) <1 measured using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523.The colour / shade to be Global White (Polyester for Interior) as approved by the Architect or Engineer-in-charge. Surface Protection: The visible panel surface shall be protected using a guard film made of LDPE of 50µ thickness, having appropriate surface adhesion (or tackiness) corresponding to surface gloss level. Light reflectance: The panel shall have a Light Reflectance of ≥ 63% in accordance to ASTM 1477-98. Flatness and Sag limit: Panels shall be flattened by precision leveller to minimize sag to less than Length/400 millimetre . The difference between the two diagonal dimensions of the panel to be less than 1 millimetre . The sag to be measured at the center in accordance with TAIM standards. Access and Plenum space: The panels to be Fully Accessible, with system height of 98 millimetre , and would require a plenum height of a minimum 450 millimetre clear space from bare ceiling / rigid structure for installation. Packaging: The Panels shall be packed in wooden crates of appropriate dimensions based on panel sizes. The wooden planks for rates shall have thickness of approx.15 millimetre , width of around 4‖ and gap between two planks around 3‖. Crates to have layer separators of 1‖ x 2‖ dimensions to prohibit load transfer on bottom panels, and the crates lifting to be 2way or 4way. The bottom of crates shall be completely closed, and the panels kept inside shall have cushioning of corrugated sheets or other appropriate material. Installation Specifications: Primary and secondary runners Installation: U-Profiles, spaced at 1200 millimetre , to be suspended from ceiling using clamping brackets and threaded rods OR hanger wires. Hanger wires must be wrapped tightly with 3 full wraps. The J-Bars (directional) shall intersect the U-profile at 90° at every module dictated by the panel length. The J-Bar is connected to the U- Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
METAL OPEN CELL CEILING : Providing & fixing horizontal level Open cell Aluminium lay-in ceiling tiles with border panels forming board edge of size 600x600x38 millimetre (Nominal) having cell size of 100x100 millimetre made of AA-3003-H14 (Tempered) grade Aluminium suitable for architectural finishes in 0.35 millimetre thickness as per in IS:2676 (1981) in Global white color. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 hours as per ASTM B117, QUV –A Test for 1000 hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000 hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E<1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. Tile shall have a Fire Performance class A as per GB 8624-2012. SUSPENSION: The tile shall be laid on 15 millimetre wide T - section flanges colour global white (matching to tile colour) having double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 millimetre & 600 millimetre Cross Tees with a web height of 38 millimetre (all sections). The deflection loading of the system shall be 12.5 kilogramme /m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kilogramme /m. The end details of the cross tee shall be made of pre hardened steel clip fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kilogramme . The T Sections shall be made of hot dipped galvanized steel 90 gsm and pre-painted steel with baked polyester paint of 0T bending capability. , The Tile & Grid system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a Manufacturing Test Certificate. INSTALLATION: To comprise main runner spaced at 1200 millimetre securely fixed to the structural soffit using suspension system (specifications below) at 1200 millimetre maximum. The First/Last suspension system at the end of each main runner shall not be greater than 450 millimetre from the adjacent wall along with the first and the last main beam shall be at less than 600 millimetre from the wall. Flush fitting 1200 millimetre long cross tees to be interlocked between main runners at 600 millimetre to form 1200 x 600 millimetre module. Cut cross tees longer than 600 millimetre require independent support. 600 x 600 millimetre module to be formed by fitting 600 millimetre long flush fitting cross tees centrally between the 1200 millimetre cross tees.Perimeter trim to be wall angles of size 3000x19x19 millimetre , secured to walls using screws at 450 millimetre centre to centre maximum. All border cut tiles shall be laid, using lay-in end cap for installation to have a Microlook effect on perimeters. Installation shall be carried out as per Manufacturer recommended procedure. SUSPENSION SYSTEM accessories manufactured and supplied by Manufacturer consisting of M6 Anchor Fasteners with hanger hole, pre Straightened Hanger wire of dia – 2.5 millimetre of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kilogramme s. Additionally, adjustable hook clips made of 0.7 millimetre thick Grade 1 C55 galvanized spring steel of dimension 100 x 20 millimetre and 4 millimetre aquiline wire to be used for level adjustment during installation purpose in main runners. Ground floor
CHANNELLED WALL PANELLING OF SIZE: 192X2400X15 millimetre - Providing and Fixing Channelled perforated panels of width 192 millimetre , thickness of 15 millimetre and length 2400 millimetre , made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White, Alumina Pearl) and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the reverse surface has a “Helmholtz” fluted perforation with consecutive 3 millimetre wide groove followed by 13 millimetre or 21 millimetre of visible pane (G-13/ G-21). The edges of the panel shall be “tongue-and-grooved” to fix special clips for installation and seamless visual. The back of the perforated panel shall have sound absorbing non-woven Soundtex acoustical fleece hot pressed to achieve NRC of 0.5. for G-21 and 0.6 for G-13. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1 millimetre /1000 millimetre and bow less than 1 millimetre /300mOne Metric Tonnehe panels shall be mounted on special aluminium splines (keel) using inside clips provided by Manufacturer and approved by the Architect/ Engineer-in-Charge. Ground floor
Providing & fixing in position false ceiling made up of 19 millimetre Plywood Conforming to ISI-303 finished with 3/4 millimetre thick veneer of approved make, shade on one side, with 4 millimetre grooves in veneer, including with support framework, pasting, screwings, cutting, jointing, finishing, fixing to the walls etc. as shown in the drawing and design provided by the Architect, and antitermite treatment to wood, plywoods etc. complete as directed by Engineer -In-Charge. Ground floor
Second floor
Fourth floor
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc.complete. Second floor
Providing and laying in situ cement concrete M20 with tremix treatment for 100 millimetre thickness for flooring with groove cutting of 4 millimetre wide and 20 millimetre deep with necessary refilling with bitumen etc. complete. Stilt Floor
Providing and laying Vitrified tiles (Matt and Antiskid Finish) in floor in 600 millimetre x 1200 millimetre sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid on 20 millimetre thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kilogramme per square metre including grouting the joints with white cement and matching pigments excetra. The tiles must be cut with the zero chipping diametermond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.as directed by engineer-in-charge. Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and laying matt finish ceramic tiles of having size 30 centimetre x 30 centimetre confirming to I.S.15622/2006 (group D II-A) and 7 to 8 millimetre thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. Fourth floor
Providing and laying ceramic tiles of having size 30 centimetre . x 30 centimetre . and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Ground floor
Second floor
Second floor
Fourth floor
Providing & laying wooden based matt finished Vitrified tiles of approved colour having size 190 to 200 millimetre x 1200 millimetre and 8 to 10 millimetre thick for flooring. Required sample is needs to get approved from the project Architect before execution on site. Work shall be carried our including all lead and lifts etc as directed by Engineer-In-Charge. Ground floor
FABRIC MESH: Design, Supply, Fabrication and Installation of Membrane Panels including scafolding. Membrane of Make Serge Ferrari/Verseidag having High Tenacity Polyester 1100Dtex multifilament Polyester with Low wick treatment for anticapillarity having minimum Weight of 460 g/m2. The Fabric should have Precontraint Technology with LEED and Green Guard certificate having 28%-50% openness porosity for Maximum Light Visibility with minimum Tensile Strength (Warp/ Weft) - 3300/ 3300 N/5 centimetre , minimum Tear Strength (Warp/ Weft) -700/700 N/5 centimetre . Fabric Flame Retardancy Rating to be Euro Class - Bs2, d0, Micro Organism Resistance-Degree 0 Excellent - EN ISO 846-A and Warranty of 10 years and Life span of 30 plus years with proven track record. The design complies with the requirements of BS and, EU Standards. The tension membrane structure shall include engineering design of structural members and accessory parts. Membrane system shall include Poly vinyl chloride / PVDF coated Membrane Fabric, Clamps and tensioning hardware as per specification, drawings and engineers' approval. Vendor to provide OEM certificate for authorisation. The Mesh must withstand its Self-load and windspeed resistance of upto 200kmph.Brackets to be fixed to the substructure or civil work considering the weathering effects. The Mesh facade to be connected to the brackets and MS Frames and sub structures. Steel of approx. 2.5kilogramme /sqft should be considered. The entire system has to be backed up by a structural stability report from a Chartered Engineer. Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on site. Work shall be carried out including all lead and lifts etc as directed by Engineer-In-Charge. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing glass door size 1.0m/1.2m x 2.7m single leaf shutter of 12 millimetre thick toughen glass frosting and edge polish as shown in the drawings or as directed , including all necessary fittings like hydraulic patch fitting, top patch fittings, Top pivot, door handle, door lock, door stopper, door soft central 180 weather seal for door edges etc. complete as directed by Engineer -IN-Charge Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing double shutter glass door of required size of 12 millimetre thick toughen glass frosting and edge polish as shown in the drawings or as directed , including all necessary fittings like hydraulic patch fitting, top patch fittings, Top pivot, door handle, door lock, door stopper, door soft central 180 weather seal for door edges etc. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete Ground floor
Fourth floor
Providing and fixing 12 millimetre thick toughen glass and edge polish as shown in the drawings or as directed, including all necessary fittings like Upper glazing profile, bottom locking glazing profile, standard gasket for profile, locking Gasket 12 millimetre , door soft central 180 weather seal for glass edges as per drawings having glass fixing sections at all sides concealed in partitions etc. complete as directed by Engineer -IN-Charge. gaps between glass panels should be filled by clear silicon weather proofing sealant , EPDM gaskets, handles all necessary fasteners and accessories complete Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing & fixing Luxalon SL4 84R plain panel sun louvers Of approved color consisting of panel 84 millimetre wide 16 millimetre deep x 0.6 millimetre thick with round edges panel length up to 6 metre coil coated on continues paint Line double baked & roll formed from enameled corrosion resistance. Aluminium Alloy AA3005 (Al. Mg.) for higher strength & good roll forming characteristics Panel shall be clipped to baked enameled aluminium SL-4 panel stringer of 33 millimetre wide & 86 millimetre deep X 0.95 millimetre thick in a standard Length of 5 metre made of double baked enameled Aluminium alloy AA5050 (Al. Mg.) black with cut-outs to hold the panel in a module of 86 millimetre center to center at a distance of 1 metre. The Carrier shall be fixed to suitable structure by means of rigid fixing details including Paint Finish : Aluminium panels shall be cromotised for maximum bond between metal & paint enameled twice under high temperature one side with full primer & luxacoat finish. The other side (Inner side) with a primer coat & skin coat on a continuous paint line etc.complete as directed by Engineer-in-charge. Ground floor
First floor
Second floor
Third floor
Fourth floor
S.S. Railing : Providing and Fixing matt finished stainless steel (Grade 304) railing with 60 millimetre x 40 millimetre and 1.6 millimetre thick pipe as handrail at top, 40 millimetre x 8 millimetre vertical patti placed at 1148 millimetre center to center, 40 millimetre x 8 millimetre horizontal patti placed at bottom 100 millimetre above the flooring,12 millimetre diametermeter pipe placed vertically in between handrail and bottom patti at 150 millimetre c/c and 75 millimetre c/c alternately as shown in the drawing. including buffing, fabricating fixtures and fastening including base or cover plate of appropriate size as directed by Engineer in charge excetra. Complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing Aluminium anodised logo of required size with building name including all fittings and fixing as per selction of project Architect. Logo image must be approved and verified by project Architect. etc complete as per direction of the Engineer-in-Charge Fourth floor
Providing and fixing in position to the exact profile and prestressing the high tensile strands to specified ultimate strength, standard end anchorages, cable ducts, grouting ducts after prestressing and bearing plates with wedges as per detailed drawings including necessary plant and machinery for prestressing etc. complete. Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing bituminous pad 25 millimetre thick for expansion joints in retaining wall, compound wall etc. complete.
Providing and fixing 50 millimetre . diameter medium class galvanised iron pipe gate with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in cement concrete block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete.
Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
Providing soling using 80 millimetre size trap metal in 15 centimetre . layer including filling voids with Crushed sand/grit, ramming , watering etc. complete.
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed.
Providing earth work in embankment with approved materials obtained from other sources upto lead of 50m. including all lifts, laying in layers of 20 centimetre . to 30 centimetre . thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97 % of standard proctor density etc. complete ( Material obtained from Other sources)
Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader/ Paver on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- By Mix in Place Method and Grading - III Material
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) millimetre Aggregate)
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 millimetre ) Aggregate)
Providing and constructing 75 millimetre . thick Modified Penetration Macadam (MPM) road surface including all materials, preparing the existing road surface, spreading 40 millimetre . stone metal layers 100% crusher broken metal with conical crusher plant heating and spraying the bitumen of specified grade @ 2 kilogramme per square metre , spreading 12 millimetre .size chips compacting with three wheel static roller having weight 8 to 10 metric tonne to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. Including picking of existing WBM surface. ( Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates)
Providing and laying bituminous macadam using crushed aggregate of Grading 1, premixed with bituminous binder, transported at site with Vehicle tracking system (VTS) , laid over a previously prepared surface , finished to the required grade ,level, alignment,and rolling to achieve the desired density for 80/100 millimetre compacted thickness with drum mix type hot mix plant with SCADA having complying essential features of Hot mix plant as per IRC-27 2009 specified conditions and attachments such as electronic load sensor based belt conveyers,automatic synchronization of bitumen and aggregate fedder,built in dust controller system and PLC for Drum Mix plant ,Sensor paver,and Vibratory roller excluding prime/Tack coat etc. complete --Bitumen 3.30% of specified grade ( Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates)
Providing and laying bituminous concrete using crushed aggregate of grading 1, premixed with bituminous binder @5.40% by weight of total mix and filler, transported at site with Vehicle tracking system (VTS) , laid over a previously prepared surface, finished to the required grade ,level, alignment, and rolling to achieve the desired density for 50 millimetre compacted thickness with drum mix plant with SCADA, Sensor paver and Vibratory roller excluding prime/Tack coat etc. complete --Bitumen of specified grade with stone dust filler. ( Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates)
Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen set footed in bitumen boller on black topped surface 2.5 kilogramme per 10 square metre ( Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates)
Providing and Laying of Rumble strips with Plastirib 2K, or equivalent 2 component cold plastic profiled material to give total width of 500 millimetre and height of 10 millimetre . Ramp provided to give width of 145 millimetre , width of ribs to be 55 millimetre laid at centre to centre distance of 35 millimetre , with reflective glass beads @ 350 gm / One Square Metre. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etc. complete.
Providing and fixing heavy duty inter locking concrete Grey paving blocks of 60 millimetre thickness of having a strength of 300 kilogramme /Sq. centimetre . of approved quality and shape on a bed of crushed sand of 25 to 30 millimetre thick including skirting joints and cleaning etc. complete.
Proving and casting in situ or precast tapering Reinforced cement concrete M-20 Mountable type Kerb without gutter ( as per IRC 86, 1983) embedded 125 millimetre below ground level over M-10 PCC finished neatly with cement mortar 1:2 , including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specificed and directed by Engineer-in-charge. Using Concrete Batching and Mixing Plant.
Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavated area of 30 centimetre. (consolidated thickness).(As per P&G DSR 2022-23 Items of garden work, Sr.No. 36a).
Suppying on site well decomposed Farmyard Manure for excavation area of depth of 30 centimetre. (Consolidated thickness) (As per P&G DSR 2022-23 Items of garden work, Sr.No. 36b).
Excavation for planting Lawn / shrub/ flower bed/ hedges/ edges/ canna bed in earth, soil of all types, soft murum, including removing the excavation material upto a distance of 50 metres for a depth of 30 centimetres. (As per P&G DSR 2022-23 Items of garden work, Sr.No. 3).
Filling fresh garden soil / silt & manure in excavated area of depth 30 centimetre (As per P&G DSR 2022-23 Items of garden work,Sr No.13)
Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting required plant species as directed etc. complete for required depth 30 centimetre for planting lawn / shrubs/ flower bed/ hedges/ edges/ canna bed / ground cover. (1/10 of semiskilled labour) (As per P&G DSR 2022-23 Items of garden work,Sr. No. 23)
Preparation of Shrubbery (Depth 30.00 centimetre ) Providing on site required variety of Shrubs (free from weeds /diesease etc.) 30 centimetre s. apart c/c.Name:- Murraya(Kamini);Bag Size 7'' x 8'',(plants list) 1(a) serial no 15.
Maintenance of Newly Developed Shrubs Area. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.31)
Plantation of Trees (Ht.1-2 mtrs) Supplying on site fresh Garden soil (i. e. 3 part soil) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 0.60 x 0.60 x 0.60 metre (consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.44a)
Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 0.60 x 0.60 x 0.60m (consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.44b)
Providing on site required variety of Tree (free from weeds /diesease etc.) 30 centimetre s. apart c/c.Name:- Bahava;Bag Size 13 x13'', ht 6-8'(plants list sr no1,item no 5B)
Excavation pit size 0.60 x 0.60 x 0.60 metre for planting small & medium ornamental plants/ large flowering/ shady trees (plant height 1 to 2 mtr.)/ palm varieties upto height 1 to 2 mtrs. in earth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 mtrs. (As per P&G DSR 2022-23 Items of garden work,Sr No.11)
Filling fresh garden soil / silt & manure in excavated pit size area of 0.60 x 0.60 x 0.60m (1/10 of unskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.21)
Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting required plant species as directed etc. complete for required pit size 0.60 x 0.60 x 0.60m. (1/10 of semiskilled labour) (As per P&G DSR 2022-23 Items of garden work,Sr No.26)
Maintenance of Newly Planted tree varieties having height 1mtr. - 2mtr. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.34)
C P & Sanitary Fixtures & Fittings Providing and fixing Ivory Opal series European type wall-hung of size 400 millimetre X 370 millimetre X 575 millimetre with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100 millimetre dia cast iron plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing Orissa Pan of size 580 X 445 X 260 millimetre with approved make flush valve including trap, cast iron soil and vent pipe upto outside face of wall including 100 millimetre diameter cast iron plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing Ivory wash basin with half pedestal of size 515 millimetre X 615 millimetre X 460 millimetre including pillar cock auto-closing system chromium plated angular stop cock long thread of approved make continental including stainless steel bottle trap of necessary pipe connection upto the outside face of the wall. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 millimetre size with pillar cock, Chromium plated Angular stop cock, long thread of approved make continental including stainless steel bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 millimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing Ivory glazed urinal with Pressmatic auto closing valve having flow rate up to 4.0 Litr/Minute of Jaquar / Cera / Hindware / Perryware or equivalent make with Poly vinyl chloride waste pipe with fitting arrangement etc.complete as directed by Engineer in charge. ( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing Chromium plated Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing Chromium plated BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing Chromium plated 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing 15 millimetre diameter Poly vinyl chloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc complete Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing sink cock with regular swinging spout (Wall / floor Mounted Model) with wall flange having flow rate up to 6.0 Litr/Minute of Jaquar / Cera / Hindware / Perryware or equivalent make incluidng other necessary fitting, etc. complete as directed by Engineer in charge. (Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing 450 millimetre x 550 millimetre size superior type Belgium mirror with 16 millimetre diameter nickel plated towel rod etc. complete. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 millimetre and of DIA: 32 millimetre and thickness 1.5 millimetre of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of SIZE - 600 millimetre (H) X 600 millimetre (D) and 32 millimetre diameter and thickness millimetre of the approved brand and make. 27c) Straight grab bar (2 NOS) Providing S.STEEL 304 GRAB RAIL (600 millimetre ),32 millimetre diameter and thickness 1.5 millimetre of the approved brand and make. Stilt Floor
Ground floor
First floor
Second floor
Third floor
Fourth floor
Terrace Floor
Internal & External SWR System Providing and fixing 75 millimetre dia stabiliser pipe/ Poly vinyl chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete Stilt Floor
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing 100 millimetre dia stabiliser pipe/ Poly vinyl chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Stilt Floor
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing Poly vinyl chloride Rain water pipes of 160 millimetre & above (preffitied 250 millimetre ) outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to I.S. 13592-1992 including proper rainwater receiving recess with Poly vinyl chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimetre to 40 millimetre from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on cement concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly vinyl chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Stilt Floor
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing Poly vinyl chloride Rain water pipes of 160 millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to I.S. 13592-1992 including proper rainwater receiving recess with Poly vinyl chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimetre to 40 millimetre from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on cement concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly vinyl chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Stilt Floor
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing 15 centimetre rigid Poly vinyl chloride Nahani trap including Poly vinyl chloride grating ,bend,connectingpiece of UPoly vinyl chloride pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete Stilt Floor
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Water Supply System Providing and fixing on walls/ceiling/floor 20 millimetre diameter Chlorinated Poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Stilt Floor
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing on walls/ ceiling/ floor 25 millimetre diameter Chlorinated Poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Stilt Floor
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing on walls/ ceiling/ floor 32 millimetre diameter Chlorinated Poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Stilt Floor
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing on walls /ceiling/ floor 40 millimetre diameter Chlorinated Poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Stilt Floor
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing on walls/ ceiling/ floor 50 millimetre diameter Chlorinated Poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Stilt Floor
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and laying in trenches 50 millimetre dai. Chlorinated Poly vinyl chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Ground Floor
Providing and laying in trenches 50 millimetre diameter heavy grade having embossed as ISI Mark galvanised iron pipes of 6.33 kilogramme per metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Ground Floor
Providing and laying in trenches 80 millimetre diameter heavy grade having embossed as ISI Mark galvanised iron pipes of 10.15 kilogramme per metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Ground Floor
Providing and fixing screw down for 20 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing screw down for 25 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing screw down for 32 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Stilt Floor
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing screw down for 40 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Stilt Floor
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing screw down for 50 millimetre diameter wheeled stop tap of brass including necessary sockets/ union nut complete. Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing 50 millimetre diameter water meter with non-return valve including strainer,sockets/ union nut and including water meter box making locking arrangement and lock. [without chamber] Ground Floor
Terrace Floor
Providing and fixing 80 millimetre diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock.[Without chamber]. Ground Floor
Terrace Floor
Providing and fixing 100 millimetre diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangements and lock. [Without chamber]. Ground Floor
Providing and making ISI Mark ferrule connection of 50 millimetre diameter to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. Ground Floor
Providing and fixing 40 millimetre diameter Ball cock medium type with Poly vinyl chloride float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Ground Floor
Terrace Floor
Providing and fixing 45 centimetre wide mild steel ladder of 40 millimetre x 6 millimetre mild steel flat stringers and steps of 18 millimetre diameter mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60 centimetre x 30 centimetre x 30 centimetre and painting the ladder complete. (AntiCorossive Paint) Ground Floor
Terrace Floor
Providing and fixing High density Polythyler (HDP) container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres
External Drainage & Rain Water System Providing , constructing and fixing 250 millimetre diameter Inspection chamber made up of UPoly vinyl chloride material of thickness 3.5 millimetre and height of 259 millimetre with inlet and outlet of 110 millimetre diameter with 75 millimetre diameter U Trap, Ultra shaft pipe of UPoly vinyl chloride material having height of 470 millimetre and fixing Ultra 250 millimetre diameter UPoly vinyl chloride cover and frame in 150 millimetre thick in cement concrete 1:2:4, having crushed sand bed of 100 millimetre thick of size 550 millimetre diameter Including excavation and refilling the sides of chamber by crushed sand cushioning 150 millimetre thickness, connecting all required UPoly vinyl chloride fittings with rubber lubricant etc. complete.
Providing , constructing and fixing 450 millimetre diameter Inspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 millimetre and height of 388 millimetre with 160 or 200 millimetre main inlet (s) outlet and 110 and / or 160 millimetre branch inlets, with 450 millimetre diameter Ultra shaft pipe of HDPE material having height of 460 millimetre , having Reinforced cement concrete cover and frame fixing in 150 millimetre thick in cement concrete 1:2:4, having crushed sand bed of 150 millimetre thick of size 750 millimetre diameter Including excavation and refilling the sides of chamber by sand crushed cushioning 150 millimetre thickness, connecting all required UPoly vinyl chloride fittings with rubber lubricant etc. complete.
Providing , constructing and fixing 600 millimetre diameter Inspection chamber made up of Polypropylene / polyethylene material Having 315 millimetre diameter inlet(s)/outlets and with eccentric reducers as per requirement to connect 160 millimetre and 200 millimetre pipes having thickness of 5 millimetre and 600 millimetre in height, with inbuilt shaft achieve the invert depth as per site condition of wall thickness of 5 millimetre having Reinforced cement concrete cover and frame fixing in 150 millimetre thick in cement concrete 1:2:4, having crushed sand bed of 150 millimetre thick of size 750 millimetre diameter Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150 millimetre thickness, connecting all required UPoly vinyl chloride fittings with rubber lubricant etc.complete.
Providing and fixing 15 centimetre x 10 centimetre salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and laying concrete pipes of I.S.NP. class of 225 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipes of I.S.NP. class of 300 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450 millimetre diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600 millimetre diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 900 millimetre diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and fixing Ductile iron Man Hole Covers/ Strom Water Grating and Grating with frame of Various sizes, weight and types and load bearing capacity as per EN-124, equivalent NECO with prior approval of concerned Superitending Engineer.
RWH - Recharge Pit Providing and constructing recharge pit of 2.0 metre deep and 1.0 metre diaameter of pre-cast Reinforced cement concrete rings with 6.5 inch diameter x 25 metre deep borewell at the floor of recharge pit including installation of combination of solid/perforated Poly vinyl chloride casing pipe wrapped around with netlon mesh including 300 millimetre thick sidefilling around outside of Reinforced cement concrete rings (annular space) with 40 millimetre size boulders including filling of recharge pit up to 0.5m depth with 25-75 millimetre clean washed gravels from bottom up followed by 0.5m depth of 10-25 millimetre of clean washed stones followed by 0.5 metre of washed river fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) media layer including covering with Reinforced cement concrete slab, manhole frame & cover, Poly vinyl chloride rungs, Poly vinyl chloride end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized Poly vinyl chloride medium well-casing pipe of 150 millimetre dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge.
MJP 22-23 Providing and constructing on sewer, Burnt brick masonry circular manhole with concentric cone 1.2 Metre diameter at bottom and 0.5 M diameter at top and upto a depth of 2.00 metre with 23 centimetre brick work in centimetre 1:4 proportion excluding excavation including foundation concrete 250 millimetre thick and haunches and channels in cement concrete 1:2:4 proportion, finishing channels in smooth rendering, providing cast iron dapuri type steps each weighing 5.5kilogramme., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C. frame and cover of 56 centimetre diameter etc. complete as directed by Engineerin-charge.
Providing and constructing on sewer, Burnt brick. masonry circular manhole with concentric cone 1.2 metre diameter at bottom and 0.5 M diameter at top and upto a depth of 1.5 metre with 23 centimetre brick work in centimetre 1:4 proportion excluding excavation including foundation concrete 250 millimetre thick and haunches and channels in cement concrete 1:2:4 proportion, finishing channels in smooth rendering, providing cast iron dapuri type steps each weighing 5.5 kilogramme ., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C. frame and cover of 56 centimetre diameter etc. complete as directed by Engineerin-charge.
Providing and constructing on sewer, Burnt Brick masonry circular manhole concentric cone 1.5 Metre diameter at bottom and 0.5 M diameter at top and upto a depth of 5.00 metre with 23 centimetre brick work, upto depth of 2 metre from top and 35 centimetre thick brick work for balance depth in centimetre 1:4 proportion with 20 millimetre thick smooth plaster on both sides in centimetre 1:2 proportion excluding excavation including foundation concrete 250 millimetre thick and haunches and channels in cement concrete 1:2:4 proportion, finishing channels in smooth rendering, providing cast iron dapuri type steps each weighing 5.5 kilogramme., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C frame and cover of 56 centimetre diameter etc. complete as directed by Engineerin-charge.
Providing and constructing on sewer, Burnt brick masonry circular manhole concentric cone 1.5 metre diameter at bottom and 0.5 M diameter at top and upto a depth of 4.5 metre with 23 centimetre brick work, upto depth of 2 M from top and 35 centimetre thick brick work for balance depth in centimetre 1:4 proportion with 20 millimetre thick smooth plaster on both sides in centimetre 1:2 proportion excluding excavation including foundation concrete 250 millimetre thick and haunches and channels in cement concrete 1:2:4 proportion, finishing channels in smooth rendering, providing cast iron dapuri type steps each weighing 5.5 kilogramme ., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C frame and cover of 56 centimetre diameter etc. complete as directed by Engineerin-charge.
Providing and constructing on sewer, Burnt brick masonry circular manhole concentric cone 1.5 metre diameter at bottom and 0.5 M diameter at top and upto a depth of 4.0 metre with 23 centimetre brick work, upto depth of 2 M from top and 35 centimetre thick brick work for balance depth in centimetre 1:4 proportion with 20 millimetre thick smooth plaster on both sides in centimetre 1:2 proportion excluding excavation including foundation concrete 250 millimetre thick and haunches and channels in cement concrete 1:2:4 proportion, finishing channels in smooth rendering, providing cast iron dapuri type steps each weighing 5.5 kilogramme ., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C frame and cover of 56 centimetre diameter etc. complete as directed by Engineerin-charge.
Providing and constructing on sewer, Burnt brick masonry circular manhole concentric cone 1.5 metre diameter at bottom and 0.5 metre diameter at top and upto a depth of 3.5 metre with 23 centimetre brick work, upto depth of 2 metre from top and 35 centimetre thick brick work for balance depth in centimetre 1:4 proportion with 20 millimetre thick smooth plaster on both sides in centimetre 1:2 proportion excluding excavation including foundation concrete 250 millimetre thick and haunches and channels in cement concrete 1:2:4 proportion, finishing channels in smooth rendering, providing cast iron dapuri type steps each weighing 5.5 kilogramme ., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C frame and cover of 56 centimetre diameter etc. complete as directed by Engineerin-charge.
Providing and constructing on sewer, Burnt brick masonry circular manhole concentric cone 1.5 M diameter at bottom and 0.5 M diameter at top and upto a depth of 3.0 M with 23 centimetre brick work, upto depth of 2 M from top and 35 centimetre thick brick work for balance depth in centimetre 1:4 proportion with 20 millimetre thick smooth plaster on both sides in centimetre 1:2 proportion excluding excavation including foundation concrete 250 millimetre thick and haunches and channels in cement concrete 1:2:4 proportion, finishing channels in smooth rendering, providing cast iron dapuri type steps each weighing 5.5 kilogramme ., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C frame and cover of 56 centimetre diameter etc. complete as directed by Engineerin-charge.
Providing and constructing on sewer, Burnt brick masonry circular manhole concentric cone 1.5 M diameter at bottom and 0.5 M diameter at top and upto a depth of 2.5 M with 23 centimetre brick work, upto depth of 2 M from top and 35 centimetre thick brick work for balance depth in centimetre 1:4 proportion with 20 millimetre thick smooth plaster on both sides in centimetre 1:2 proportion excluding excavation including foundation concrete 250 millimetre thick and haunches and channels in cement concrete 1:2:4 proportion, finishing channels in smooth rendering, providing cast iron dapuri type steps each weighing 5.5 kilogramme ., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C frame and cover of 56 centimetre diameter etc. complete as directed by Engineerin-charge.
Valve chamber with cast iron manhole frame and covers Providing and constructing Burnt brick masonry valve chamber 90 x 60 centimetre internal size and depth upto 1.2 M with 90 x 60 centimetre size CI manhole frame and cover of 50 kilogramme . with 15 centimetre thick 1:3:6 proportion Plain cement concrete bedding, excluding excavation, Burnt brick masonry in centimetre 1:5 proportion, 12 millimetre thick cement plaster in centimetre 1:4 proportion on both sides with providing and fixing cast iron manhole frame and cover in Reinforced cement concrete 1:2:4 coping or Reinforced cement concrete 1:2:4 proportion x 15 centimetre thick slab, etc. complete as directed by Engineer-in-charge.
Valve chamber with cast iron manhole frame and covers Providing and constructing Burnt brick masonry valve chamber 90 x 90 centimetre internal size and depth upto 1.2 M with 15 centimetre thick 1:3:6 proportion Plain cement concrete bedding, excluding excavation, Burnt brick masonry in centimetre 1:5 proportion, 12 millimetre thick cement plaster in centimetre 1:4 proportion on both sides with providing and fixing cast iron manhole frame and cover in Reinforced cement concrete 1:2:4 coping or Reinforced cement concrete 1:2:4 proportion x 15 centimetre thick slab, etc. complete as directed by Engineer-in-charge.
Valve chamber with cast iron manhole frame and covers Providing and constructing Burnt brick masonry valve chamber 90 x 90 centimetre internal size and depth upto 1.5 M with 15 centimetre thick 1:3:6 proportion Plain cement concrete bedding, excluding excavation, Burnt brick masonry in centimetre 1:5 proportion, 12 millimetre thick cement plaster in centimetre 1:4 proportion on both sides with providing and fixing cast iron manhole frame and cover in Reinforced cement concrete 1:2:4 coping or Reinforced cement concrete 1:2:4 proportion x 15 centimetre thick slab, etc. complete as directed by Engineer-in-charge.
Valve chamber with cast iron manhole frame and covers Providing and constructing Burnt brick masonry valve chamber 90 x 90 centimetre internal size and depth upto 1.8 M with 15 centimetre thick 1:3:6 proportion Plain cement concrete bedding, excluding excavation, Burnt brick masonry in centimetre 1:5 proportion, 12 millimetre thick cement plaster in centimetre 1:4 proportion on both sides with providing and fixing cast iron manhole frame and cover in Reinforced cement concrete 1:2:4 coping or Reinforced cement concrete 1:2:4 proportion x 15 centimetre thick slab, etc. complete as directed by Engineer-in-charge.
Valve chamber with cast iron manhole frame and covers Providing and constructing Burnt brick masonry valve chamber 90 x 90 centimetre internal size and depth upto 2.1 M with 15 centimetre thick 1:3:6 proportion Plain cement concrete bedding, excluding excavation, Burnt brick masonry in centimetre 1:5 proportion, 12 millimetre thick cement plaster in centimetre 1:4 proportion on both sides with providing and fixing cast iron manhole frame and cover in Reinforced cement concrete 1:2:4 coping or Reinforced cement concrete 1:2:4 proportion x 15 centimetre thick slab, etc. complete as directed by Engineer-in-charge.
Supplying and erecting 50 millimetre diameter cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 65 millimetre diameter cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 80 millimetre diameter cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 100 millimetre diameter cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 20/25 millimetre dia gun metal air release cock, with necessary galvanised iron coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and erecting 75/80 millimetre dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting non return valve 25 millimetre dia in position made of gun metal complete.
Supplying and erecting non return valve 40 millimetre dia in position made of gun metal complete.
Supplying and erecting non return valve 50 millimetre dia in position made of gun metal complete.
Supplying and erecting non return valve 65 millimetre dia in position made of gun metal complete.
Supplying and erecting pump protection relay comprising current sensing phase failure and UV+OV relay with dry run and overload protection suitable for 3 phase pumps.
Supplying & erecting Water level controller 230/415 V, A.C. , Two way under ground tank operation only.
Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only.
Supplying & erecting Poly vinyl chloride coated 5 millimetre diameter Brass sensor/ electrode duly wired with nuts & bolts complete (Set of 3 Nos)
Supplying & erecting minimum three & above star rated Centrifugal water pump (Monoblock), 415 V, three phase 50 cycles A.C. supply of 7.5 KW/10 HP with discharge 1150/600 Litres per Minute (LPM) for head of 24/69 m and 65 millimetre suction/ 50 millimetre delivery pipe of size, on provided cement concrete foundation as per specification No. WP-CGP
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 28-42 AMP,S.P.P., Combined a millimetre eter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 5.625 KW/7.5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 57 to 22 m and discharge from 120 to 900 litres. . per minute & pipe of Suction 75 millimetre /Delivery 65 millimetre diameter erected with necessary H type clamps as per specification No. WP-OSP
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65 millimetre /Delivery 50 millimetre diameter erected with necessary H type clamps as per specification No. WP-OSP
Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined a millimetre eter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes of 65 millimetre nominal inner dia Pipes, having thermal stability for hot & cold water supply, including all Chlorinated Poly vinyl chloride plain & brass threaded fittings. This includes jointing of pipes & fittings with one step Chlorinated Poly vinyl chloride solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer.
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes of 80 millimetre nominal inner dia Pipes, having thermal stability for hot & cold water supply, including all Chlorinated Poly vinyl chloride plain & brass threaded fittings. This includes jointing of pipes & fittings with one step Chlorinated Poly vinyl chloride solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer.
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes of 100 millimetre nominal inner dia Pipes, having thermal stability for hot & cold water supply, including all Chlorinated Poly vinyl chloride plain & brass threaded fittings. This includes jointing of pipes & fittings with one step Chlorinated Poly vinyl chloride solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer.
Providing & Fixing 40 millimetre Dia Y Strainer (screwed / flanged) with stainless steel fin wire mesh perforated sheet basket with necessary flange / uionons nuts, bolts and wahsers complete as required. All work Complete as per direction of the Engineer-in-Charge.
Providing & Fixing 50 millimetre Dia Y Strainer (screwed / flanged) with stainless steel fin wire mesh perforated sheet basket with necessary flange / uionons nuts, bolts and wahsers complete as required. All work Complete as per direction of the Engineer-in-Charge.
Providing & Fixing 65 millimetre Dia Y Strainer (screwed / flanged) with stainless steel fin wire mesh perforated sheet basket with necessary flange / uionons nuts, bolts and wahsers complete as required. All work Complete as per direction of the Engineer-in-Charge.
Providing & Fixing 80 millimetre Dia Y Strainer (screwed / flanged) with stainless steel fin wire mesh perforated sheet basket with necessary flange / uionons nuts, bolts and wahsers complete as required. All work Complete as per direction of the Engineer-in-Charge.
Providing & Fixing 100 millimetre Dia Y Strainer (screwed / flanged) with stainless steel fin wire mesh perforated sheet basket with necessary flange / uionons nuts, bolts and wahsers complete as required. All work Complete as per direction of the Engineer-in-Charge.
Supplying, fixing, testing and commissioning of 65 millimetre diameter sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required.
Supplying, fixing, testing and commissioning of 50 millimetre diameter sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required.
Providing and Fixing it in position, Alighning to correct position, testing and commissioning of chromium plated brass Grating (Viking 41615) of Rectangular type with openable circular lid 150 millimetre nominal size square 100 millimetre diameter of the inner hinged round grating. including setting in floor with cement motor to match with floor finish as per architect requirement complete including all accessories. All work Complete as per direction of the Engineer-in-Charge.
Providing and Fixing it in position, Alighning to correct position, testing and commissioning of chromium plated brass Grating of Close on Top type (Viking 45290) with openable circular lid 150 millimetre nominal size square 100 millimetre diameter of the inner hinged round grating. including setting in floor with cement motor to match with floor finish as per architect requirement complete including all accessories. All work Complete as per direction of the Engineer-in-Charge.
Providing and Fixing it in position, Alighning to correct position, testing and commissioning of chromium plated brass P Trap 40 millimetre Size for wash basin, Urinal & Kitchen Sinks. (Viking-5898 V6 H12) with all necessary fixtures and fitting etc complete as directed by the Engineer-in-Charge. (Fixtures and fittings as per Approved C.P & Sanitary Product sheet). All work Complete as per direction of the Engineer-in-Charge.
Providing and fixing 600 millimetre long mild steel hot dip galvanized Puddel Flange fabricated out of 6 millimetre thick MS plates of 25 millimetre dia pipe size and pipe shall be confirming to IS:1239 heavy class pipes properly fixed in walls / top slab of tanks. The entire fittings shall be hot dipped galvanized after fabrication. Length shall be minimum 600 millimetre or wall thickness plus 200 millimetre on either side (which ever is more). Each Puddle shall be flange at outer side for connection of pipe / fittings. All work Complete as per direction of the Engineer-in-Charge.
Providing and fixing 600 millimetre long mild steel hot dip galvanized Puddel Flange fabricated out of 6 millimetre thick mild steel plates of 50 millimetre Dia Pipe size and pipe shall be confirming to IS:1239 heavy class pipes properly fixed in walls / top slab of tanks. The entire fittings shall be hot dipped galvanized after fabrication. Length shall be minimum 600 millimetre or wall thickness plus 200 millimetre on either side (which ever is more). Each Puddle shall be flange at outer side for connection of pipe / fittings. All work Complete as per direction of the Engineer-in-Charge.
Providing and fixing 600 millimetre long mild steel hot dip galvanized Puddel Flange fabricated out of 6 millimetre thick mild steel plates of 65 millimetre Dia Pipe size and pipe shall be confirming to IS:1239 heavy class pipes properly fixed in walls / top slab of tanks. The entire fittings shall be hot dipped galvanized after fabrication. Length shall be minimum 600 millimetre or wall thickness plus 200 millimetre on either side (which ever is more). Each Puddle shall be flange at outer side for connection of pipe / fittings. All work Complete as per direction of the Engineer-in-Charge.
Providing and fixing 600 millimetre long mild steel hot dip galvanized Puddel Flange fabricated out of 6 millimetre thick mild steel plates of 80 millimetre Dia Pipe size and pipe shall be confirming to IS:1239 heavy class pipes properly fixed in walls / top slab of tanks. The entire fittings shall be hot dipped galvanized after fabrication. Length shall be minimum 600 millimetre or wall thickness plus 200 millimetre on either side (which ever is more). Each Puddle shall be flange at outer side for connection of pipe / fittings. All work Complete as per direction of the Engineer-in-Charge.
Providing and fixing 600 millimetre long mild steel hot dip galvanized Puddel Flange fabricated out of 6 millimetre thick mild steel plates of 100 millimetre Dia Pipe size and pipe shall be confirming to IS:1239 heavy class pipes properly fixed in walls / top slab of tanks. The entire fittings shall be hot dipped galvanized after fabrication. Length shall be minimum 600 millimetre or wall thickness plus 200 millimetre on either side (which ever is more). Each Puddle shall be flange at outer side for connection of pipe / fittings. All work Complete as per direction of the Engineer-in-Charge.
Providing and fixing 600 millimetre long mild steel hot dip galvanized Puddel Flange fabricated out of 6 millimetre thick mild steel plates of 150 millimetre Dia Pipe size and pipe shall be confirming to IS:1239 heavy class pipes properly fixed in walls / top slab of tanks. The entire fittings shall be hot dipped galvanized after fabrication. Length shall be minimum 600 millimetre or wall thickness plus 200 millimetre on either side (which ever is more). Each Puddle shall be flange at outer side for connection of pipe / fittings. All work Complete as per direction of the Engineer-in-Charge.
Providing and fixing 600 millimetre long mild steel hot dip galvanized Puddel Flange fabricated out of 6 millimetre thick mild steel plates of 200 millimetre Dia Pipe size and pipe shall be confirming to IS:1239 heavy class pipes properly fixed in walls / top slab of tanks. The entire fittings shall be hot dipped galvanized after fabrication. Length shall be minimum 600 millimetre or wall thickness plus 200 millimetre on either side (which ever is more). Each Puddle shall be flange at outer side for connection of pipe / fittings. All work Complete as per direction of the Engineer-in-Charge.
Providing and fixing 600 millimetre long mild steel hot dip galvanized Puddel Flange fabricated out of 6 millimetre thick mild steel plates of 250 millimetre Dia Pipe size and pipe shall be confirming to IS:1239 heavy class pipes properly fixed in walls / top slab of tanks. The entire fittings shall be hot dipped galvanized after fabrication. Length shall be minimum 600 millimetre or wall thickness plus 200 millimetre on either side (which ever is more). Each Puddle shall be flange at outer side for connection of pipe / fittings. All work Complete as per direction of the Engineer-in-Charge.
Providing and Fixing it in position, Alighning to correct position, testing and commissioning of Paper / Tissue Holder With Cover (Silver) (Kohler-5633IN-CP) with all accessories upto the satisfaction of the Architects / Engineer in chrge and making corrections/ modifications up to acceptable limit inlcuding all accessories as per manufacturers guideline/ product installation and operational manual. All work Complete as per direction of the Engineer-in-Charge.
Providing and Fixing it in position, Alighning to correct position, testing and commissioning of Square 610 millimetre single towel (Kohler-25065IN-CP) with all accessories upto the satisfaction of the Architects / Engineer in chrge and making corrections/ modifications up to acceptable limit inlcuding all accessories as per manufacturers guideline/ product installation and operational manual. All work Complete as per direction of the Engineer-in-Charge.
INTERIOR WORK SINGLE SEATER SOFA Providing and fixing Frame in Hardwood fully Cushioned in Seat & Back, with ar mild steel . Stainless Steel frame/Legs at the base. Single Seater Sofa of dimentions 840 millimetre W x 850 millimetre D x 750 millimetre H Armrest 150 millimetre with Curve- Seat 550 millimetre , as per the sample approved by Architect, etc complete as directed by Engineer In Charge. FORUM LEGS, SQUARE PIPE,REGULAR POWDER COAT FINISH, FORUM END SOFA LH SUPERSTRUCTURE,WW AST FAB FORUM END SOFA RH SUPERSTRUCTURE,WW AST FAB Stilt Floor
Ground floor
TWO SEATER SOFA Providing and fixing Frame in Hardwood fully Cushioned in Seat & Back, with ar mild steel . Stainless Steel Legs at the base. Two Seater Sofa - 1350 millimetre W x 750 millimetre D x 750 millimetre H Armrest 150 millimetre with Curve- Seat 550 millimetre , as per the sample approved by Architect, etc complete as directed by Engineer In Charge. Ground floor
Third floor
Fourth floor
THREE SEATER SOFA Providing and fixing Frame in Hardwood fully Cushioned in Seat & Back, with ar mild steel . Stainless Steel Legs at the base. Three Seater Sofa - 1950 millimetre W x 750 millimetre D x 750 millimetre H Armrest 150 millimetre with Curve- Seat 550 millimetre , as per the sample approved by Architect, etc complete as directed by Engineer In Charge. Stilt Floor
Ground floor
Second floor
Fourth floor
THREE SEATER SOFA Additional SP Officer Cabin and Police Superitendent Office Cabin - Providing and fixing Frame in Hardwood fully Cushioned in Seat & Back, with ar mild steel . Stainless Steel Legs at the base. Three Seater Sofa - 1950 millimetre W x 750 millimetre D x 750 millimetre H Armrest 150 millimetre - Seat 550 millimetre Seat Height 425 millimetre as per the sample approved by Architect, etc complete as directed by Engineer In-Charge. Second floor
Fourth floor
SIDE TABLE 600X600 - Providing and fixing Table With Top in BSL of 25 millimetre thk with all Sides Edge Banding, Frame in Stainless Steel / M.S Powder Coating with 25 millimetre square pipe of 16g, table Size 600 millimetre L x 600 millimetre W x 450 millimetre height, as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground floor
First floor
Second floor
Fourth floor
CENTER TABLE 750X750 - Providing and fixing Table in Stainless Steel Square pipe frame of 25 millimetre x 16g. Top & bottom with Smoke Glass with polished edges of 12 millimetre thick Size:- 750 millimetre L x 750 millimetre W x 450 millimetre height as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Second floor
Fourth floor
Center Table in Waiting Area (750 millimetre x 750 millimetre) - Providing and fixing Table Table With Top in BSL of 25 millimetre thk with all Sides Edge Banding, Frame in Stainless Steel / M.S Powder Coating with 25 millimetre square pipe of 16g.table Size 750 millimetre L x 750 millimetre W x 450 millimetre height as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Stilt Floor
Ground floor
Second floor
Fourth floor
High Back Revolving Chairs - Providing and fixing High Back Revolving Chair Chair in Moulded Ply with Head rest, PU foam in Back & Moulded PU Seat, "T" Adjustable Ar mild steel , Synchronized Multi Lock Mechanism, Aluminium Base, & Gas Lift. as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Back Height - High Back Back Finish - Mesh with Adjustable Lumber Support Back Mesh Color - Black Seat Finish - Fabric (with centimetre Foam) Seat Fabric Color - Black Seat Height Adjustment - Pneumatic Mechanism Type - Synchronized Tilt Back Tilt Lock - Upright Position Back Tilt Tension - Adjustable Armrests Type - 1-D Adjustable Armpads Type - Polyurethane Base Type - 5-Star in Black Nylon Ground floor
First floor
Second floor
Third floor
Fourth floor
MEDIUM BACK CHAIR WITH SLEDGE BASE - Providing and fixing Medium Back Chair with SS sledge base Chair in Moulded Ply, PU foam in Back & Moulded PU Seat, "T" Adjustable Ar mild steel , with SS sledge base.as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. SPECIFICATIONS: Back Height - Medium Back Back Finish - Mesh with Adjustable lumber support Back mesh colour and seat colour - Black Seat Height Adjustable with gas Lift. Mechanism Type - Synchronized Tilt Back Lock - Upright position Back Tilt Tension - Adjustable Armrests Type -1D PU Ar mild steel Ground floor
First floor
Second floor
Third floor
Fourth floor
Mid Back Revolving Chairs - Providing & Arrangemnt of Mid Back,ECO CTS Mechanism,Fixed Armrest,Gasliftfor Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery Ground floor
First floor
Second floor
Third floor
Fourth floor
FIX CHAIR FOUR LEGS - Providing and fixing Fix Lounge Chair Chair With Stainless Steel Frame in front 25 millimetre diameter & Back Leg Rectangle pipe . 12 millimetre Moulded ply in Seat & Back duly Cushioned with PP Ar mild steel as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground floor
First floor
Second floor
Third floor
Fourth floor
L-SHAPE TABLE - Providing and fixing table in "L" shape of size 1.35 metre x 0.6 metre, side table 1.05 m x 0.38 metre, having height of 750 millimetre as shown in drawing made up of 12 millimetre / 19 millimetre thick plywood conforming to ISI-303, The top shall be finished with 4 millimetre thick veneer with wooden beading 12 millimetre x 40 millimetre finished with neutral matte polish, all the support Plywood Conforming to ISI-303 19 millimetre thick finished with partly grey and white laminate, internal surfaces finished 0.8 millimetre thick internal laminate, including provision for cable manager, raceways for cables and wires, plywood foot rest finished with 0.8 millimetre thick laminate, including shutter & drawers with telescopic sliders , handles , lock, magent, cable manager, hinges etc. as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods etc.complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground floor
First floor
Second floor
Third floor
Fourth floor
CORNER WORKSTATION 1350x1350x600x1200 millimetre height. (CLUSTER OF 1) - Providing and fixing of workstations System 50 millimetre thick Tile Base Partition System at 1200 millimetre height, 1st Module with Prelam particle board Tile, 2nd Module Pin-up, Marker & Fabric Tile, Electrical connection below the worktop on Raceway & Skirting Level, Table Top considered in 25 millimetre thick prelam particle board finish with Poly vinyl chloride lipping 2 millimetre thick having height 727 millimetre from Ground Level, Understructure with Prelam Gable Ends with Brackets and Return Prelam Combo Storage having size 750x400x 727 millimetre etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground floor
First floor
Second floor
Third floor
Fourth floor
TABLE 1200X600 - Free Standing Table @ 1200Lx600Dx750HT Providing and fixing Table of Size 1200 x 600 x 750 millimetre . Top: made from 25 millimetre Prelaminated Particle board. All edges are covered by 2 millimetre . thick Poly vinyl chloride edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18 millimetre both side prelaminated particle boards.All edges are covered by 0.8 millimetre Poly vinyl chloride edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. millimetre . with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 millimetre prelaminated particle board, Ground floor
First floor
Third floor
CONFERENCE TABLE - Providing and fixing conference room table of size 5.0 metre x 1.2 metre, having height of 750 millimetre as shown in drawing made up of 12 millimetre / 19 millimetre thick plywood Conforming to ISI-303 , The top shall be finished with veneer, all the support Plywood Conforming to ISI-303 19 millimetre thick face finished with white laminate, as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods and melamine polishing 2 coat to all veneer and wooden surface etc.complete as directed by Engineer -In-Charge. Second floor
CONFERENCE TABLE C SHAPE - Providing and fixing conference room table top of 'C' shape size 5.3 metre x 0.75 metre, and 2.13metre x 0.75metre having height of 0.75 m with verticle supports, footrest, architectural shape as shown in drawing made up of 12 millimetre and 19 millimetre thick plywood of Century make commercial ply BWR grade Conforming to ISI-303 or equivalent make, The top and facia shall be finished with solid surface 6 millimetre thick, veneer finish to ply surface as per detailed drawing,inner sides to be finished with 1 millimetre thick laminate , foot rest to be finished with 0.8 millimetre thick laminate of royal touch or equivalent make confirming to (ISI 2046), , antitermite treatment, melamine polishing two coat to all veneer surface, fevicol, nails, cable manager, labours,material testing charges . All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground floor
Fourth floor
WAITING AREA CHAIRS - Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. - Second floor
Third floor
DINING TABLE SET - Providing and fixing Cafe table in "Square" shape of required size 900x900 as shown in drawing made up of 12 millimetre / 19 millimetre thick plywood/Prelam boards conforming to ISI-303, Trio 03 : Square Cafe Table Table with BSL Top of 25 millimetre thk & Round finished with Side Edges finished with Poly vinyl chloride Edge banding, Frame in S. Steel / M.S of 60 millimetre dia Centre Pipe supported by 4 legs of 45 millimetre T pipes, fitted on M.S. bracket. Sizes:- 900 millimetre x 900 millimetre Squareetc. as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods and polishing 2 coat to all surface etc. complete as directed by Engineer -In-Charge Ground floor
ROUND DINING TABLE - Providing and Fixing 4 Seater Round Dining Table of Size :600 millimetre and 750 millimetre height. Main table tops to be made up of 25 millimetre thick prelaminated particle board positioned at 750 millimetre high from ground level. understructure Legs should be made of CRCA pipe with round shape with Powder coated etc. complete as directed by Engineer -IN-Charge. Ground floor
First floor
DINNING CHAIR - Providing and placing injection molded Polypropylene without handle chair of size 450 millimetre x 560millimetre and height 815 millimetre made up of primarily of 7/16" diameter steel rod with fire retardant power coating, injection molded Polypropylene seat and back etc. complete as per drawing and image and as directed by Engineer-In- Charge. Ground floor
First floor
Double Faced Mobile Unit for Compactor 2150 millimetre H x 2745 millimetre W x 900 millimetre D - Providing and fixing Double Faced Mobile Unit for Compactor 2150 millimetre H x 2745 millimetre W x 900 millimetre D - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 millimetre thick mild steel Sheet Size of Channel 25 millimetre x 100 millimetre x 45 millimetre . GUIDE RAILS : The guide rails shall be made out of 28 millimetre Bright bar placed on 1.2 millimetre thick M.S. Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition etc. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 kilogramme s. VERTICAL PANEL : Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together, central lock when operated gets locked with the floor & does not allow access to the units. DRIVE MECHANISM : Driving Mechanism will be provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000 millimetre x 200 millimetre x 60 millimetre . DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification & retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns). Second floor
Third floor
Double Faced Mobile Unit for Compactor 2150 millimetre H x 1830 millimetre W x 900 millimetre D - Double Faced Mobile Unit for Compactor 2150 millimetre H x 1830 millimetre W x 900 millimetre D Providing and fixing Double Faced Mobile Unit for Compactor 2150 millimetre H x 1830 millimetre W x 900 millimetre D - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 millimetre thick mild steel Sheet Size of Channel 25 millimetre x 100 millimetre x 45 millimetre . GUIDE RAILS : The guide rails shall be made out of 28 millimetre Bright bar placed on 1.2 millimetre thick M.S. Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition etc. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 kilogramme s. VERTICAL PANEL : Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together, central lock when operated gets locked with the floor & does not allow access to the units. DRIVE MECHANISM : Driving Mechanism will be provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000 millimetre x 200 millimetre x 60 millimetre . DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification & retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns). Second floor
Third floor
Single Faced Fixed Unit for Compactor 2150 millimetre H x 2745 millimetre W x 457 millimetre D - Providing and fixing Single Faced Fixed Unit for Compactor 2150 millimetre H x 2745 millimetre W x 457 millimetre D - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 millimetre thick mild steel Sheet Size of Channel 25 millimetre x 100 millimetre x 45 millimetre . GUIDE RAILS : The guide rails shall be made out of 28 millimetre Bright bar placed on 1.2 millimetre thick M.S. Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition etc. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 kilogramme s. VERTICAL PANEL : Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together,central lock when operated gets locked with the floor & does not allow access to the units. DRIVE MECHANISM : Driving Mechanism will be provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000 millimetre x 200 millimetre x 60 millimetre . DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification & retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns). Second floor
Third floor
Single Faced Fixed Unit for Compactor 2150 millimetre H x 1830 millimetre W x 457 millimetre D - Single Faced Fixed Unit for Compactor 2150 millimetre H x 1830 millimetre W x 457 millimetre D - Providing and fixing Single Faced Fixed Unit for Compactor 2150 millimetre H x 1830 millimetre W x 457 millimetre D - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 millimetre thick mild steel Sheet Size of Channel 25 millimetre x 100 millimetre x 45 millimetre . GUIDE RAILS : The guide rails shall be made out of 28 millimetre Bright bar placed on 1.2 millimetre thick M.S. Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition etc. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 kilogramme s. VERTICAL PANEL : Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together, central lock when operated gets locked with the floor & does not allow access to the units. DRIVE MECHANISM : Driving Mechanism will be provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000 millimetre x 200 millimetre x 60 millimetre . DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification & retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns). Second floor
Third floor
RECEPTION TABLE - Providing and fixing table in "Rectangular" shape of size 2.4 metre x 0.750 metre having height of 750/1050 millimetre & side cabinate/Pedestal 0.7mx0.55mx0.70 metre deep as shown in drawing 12 millimetre / 19 millimetre thick plywood conforming to ISI -303 , The 50 millimetre thick top of made up of 19+19 millimetre Ply fitted to 50x12 millimetre tickwood frame on either sides shall be finished with veneer to top and edge, 50 millimetre thick section made up from ply for hand rest with frame finished with white uni-core laminate, 19 millimetre /12 millimetre thick ply for drawer externally finished with grey laminate, & internally finished with white laminate, all the support,horizantal members of plywood, 19 millimetre thick conforming to ISI -303 finished with veneer/ internal surfaces finished with 0.8 millimetre thick internal laminate/External Laminates as shown indrawings, powder coated Aluminium skirting at bottom matching to Veneer/ white uni-core laminate with veneer ,including provision for cable manager, raceways for cables and wires, ply foot rest finished with veneer, including shutters and drawers with telescopic sliders of required sizes, hinges, handles, lock , magnet, cable manager, knobs, including pasting,screwings, cutting, jointing, finishing etc. as shown in the drawing and antitermite treatment to all plywoods and polishing 2 coat to all veneer and wooden surface etc. complete as directed by Engineer -In-Charge. Ground floor
Second floor
Third floor
TV UNIT 1800X350X300 - Providing and fixing TV Unit of size 1.8 m x 0.350 m, having height of 300 millimetre as shown in drawing made up of 19+19 millimetre thick plywood conforming to ISI-303, The top shall be finished with veneer, all the support Plywood Conforming to ISI-303 19 millimetre thick finished with white laminate, internal surfaces finished 0.8 millimetre thick internal laminate, including provision for cable manager, raceways for cables and wires,including shutters, handles, lock, hinges, cable manager, magnet etc. as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods etc. complete as directed by Engineer -In-Charge.- Ground floor
Second floor
Fourth floor
Carpet-Providing and fixing in position, heavy duty 100 % polypropylene Carpet , 980 gsm, 4 mtr width, fire retardant, plain backing, needle punch technology, stain proof as per Architectural & Acoustical design, instructions and complete in all aspects. Ground floor
Fourth floor
90 millimetre thick Plywood Panelling with One side Veneer -Providing and fixing plywood Panelling of appropriate size having thickness of 90 millimetre , made up of 70 millimetre x 38 millimetre teakwood supporting members at a vertical distance of 0.6 m c/c and horizontal distance of 0.6 m c/c covering on one face with 19 millimetre thick Plywood Conforming to ISI-303 finished with 3/4 millimetre thick veneer of approved make, shade on one side, with 4 millimetre grooves in veneer, & 63 millimetre high. aluminum skirting finished with powder coating matching to veneer including pasting, screwings, cutting, jointing, finishing, fixing to the walls etc. as shown in the drawing and design provided by the Architect, and antitermite treatment to wood, plywoods and MDF etc. complete as directed by Engineer -In-Charge. Ground floor
Second floor
Fourth floor
Providing & Fixing in position, Fabric wrapped Compressed polyester fibre nonwoven 9 millimetre panels above the wood wool board panelling or existing sal wood frame, using adhesive, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc complete - Ground floor
Fourth floor
Curtains/Blinds MAC - BLACKOUT TORINO TR 5408 - Providing and fixing Curtains/Blinds MAC - BLACKOUT TORINO TR 5408 for windows, including all necessary fixtures and fittings, as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. - Ground floor
First floor
Second floor
Third floor
Fourth floor
Providing and fixing Roller Blind MAC - BLACKOUT GRACIA BGR5606 for windows, including all necessary fixtures and fittings, as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground floor
Fourth floor
CURTAIN MAC - Zebrano NS-73 - Providing and fixing curtains MAC - Zebrano for windows, including all necessary fixtures and fittings, as per the sample approved by Architect, etc complete as directed by Engineer In Charge. Fourth floor
Medium Height Storage Cabinate - Providing and fixing "Rectangular" Shaped Medium high storage cabinate of sizes 1350 millimetre x 450 millimetre x 1200 millimetre as shown in drawing, made up of 12 millimetre / 19 millimetre thick plywood conforming to ISI-303 , 4 door storage unit with both side laminates & all side edge bending in, all the support, horizantal members made of plywood,19 millimetre thick finished with external laminate, internal surfaces finished with 0.8 millimetre thick internal laminate, including shutters and drawers with telescopic sliders of required sizes, handles , hinges, lock, knobs, magnet etc as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods and polishing 2 coat to all veneer and wooden surface etc.complete as directed by Engineer -In-Charge. Ground floor
First floor
Second floor
Third floor
Fourth floor
Full Storage Cabinate - Providing and fixing "Rectangular" Shaped Full storage cabinate of sizes 1800 millimetre x 600 millimetre x 2100 millimetre as shown in drawing, made up of 12 millimetre / 19 millimetre thick plywood conforming to ISI-303 , 4 door storage unit with both side laminates & all side edge bending in, all the support, horizantal members made of plywood,19 millimetre thick finished with external laminate, internal surfaces finished with 0.8 millimetre thick internal laminate, including shutters and drawers with telescopic sliders of required sizes, handles , hinges, lock, knobs, magnet etc as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods and polishing 2 coat to all veneer and wooden surface etc.complete as directed by Engineer -In-Charge. - First floor
Third floor
Fourth floor
PAINTINGS IN SQM - Providing And Fixing In Position Various Type And Size Of Paintings In All Suites / Areas, From Recognised Artists, Including The Materials Of Painting Like Canvas, Colours, Design, Frames Etc, Complete To Be Displayed In All Respect On The Areas Allotted, On Stretched Canvas, As Per The Sizes And Designs Approved By The Principal Architect To All The Involved Artists. Stilt Floor
Second floor
Fourth floor
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 500kVA, Mineral oil immersed and naturally cooled Intdoor type, Copper wound Non-sealed transformer delta/star connected additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, having 7 number of tap positions , with standard accessories complete with test certificate with losses below 1860 Watts at 50% load, 5300 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL. NOTE 1
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 250 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 42.30 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 425 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG
Supplying , erecting & terminating XLPE insulated, galvanised steel formedwire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT For 11 kV (E) by 28%
Providing and erecting Heat shrinkable indoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT
Supplying, erecting, testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 50/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation.
Supplying and erecting 150 kVAr, 3 phase, 50 Hz., Power contactors Derated for microprocessor APFC controller with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 kV
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP.
Supplying and erecting G.I. strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joint required. as per specification No (EA-EP).
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door,1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no.SW-SWR/MCCB NOTE 1 & 2
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR/MCB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (NOTE 3)
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (NOTE 3)
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiseling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 800mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2.
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF - NOTE
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware.
Supplying and erecting PVC slotted box trunking of size 100x100 mm. with accessories on wall/ceiling as per specification No: WG-MA/SLBOX
Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave, with backup time of 0.5 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/26Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority
Supply, Installation, testing and commissioning of cubical type MV Panel conform to IEC:61439-I as per technical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation Name - MAIN LT FP - Duty -Duty: Indoor Type (IP 42) - Incomer-1 Nos of 800A FP MDO ACB, - Busbar - 800A FP Al Busbar - Outgoings - 400A FL MCCB 3 NOs, 630A FP MCCB 1 NOS, 200A FP MCCB 2 Nos, 100A FP MCCB with SPD, MFM, all indicators showing status of ON, OFF, TRIP, complete as per schematic
Supply, Installation, testing and commissioning of cubical type MV Panel conform to IEC:61439-I as per technical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation Panel Details :- Name - MAIN LT PANEL 01 - Duty -Duty: Indoor Type (IP 42) - Incomer-2 Nos of 630A FP MCCB - Busbar - 630A TPN Al Busbar - Outgoings - 1 NOS 400A FP MCCB & 100A FP MCCB 9 NOS, 250A FP MCCB 1 NOS, with dual sourse MFM, indiicators SPD and all accessories complete as per schematic
Supply, Installation, testing and commissioning of cubical type MV Panel conform to IEC:61439-I as per technical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation Panel Details :- Name - DG PANEL - Duty -Duty: Indoor Type (IP 42) - Incomer-1 Nos of 400A FP MCCB, - Busbar - 400A TPN Al Busbar - Outgoings - 1 NOS 400A FP MCCB & 200A FP MCCB as per schematic
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP-WCR/WC
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
Supplying & erecting Dewatering Monoblock pump set 415V, 3 phase, 50C/s, A.C. supply of 2.25KW/ 3 H.P., of 12 to 26 m head with 560 to 70 LPM discharge, 10.5mm Solid Handling Capacity, non clogging minimised abrasive wear, large impeller clearance & maintenance free pump set with water proof cable duly sealed with epoxy material built in protection to prevent the motor from burn out due to abnormal operation. specially designed high efficiency motor with F class insulation & the pump mechanically sealed in the oil chamber,. etc. complete as per specification no. DWP- SMP
Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 H.P.
Supplying and erecting pump protection relay comprising current sensing phase failure and UV+OV relay with dry run and overload protection suitable for 3 phase pumps.
Supplying & erecting Water level controller 230/415 V, A.C. , Two way under ground tank operation only.
Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only.
Supplying & erecting PVC coated 5 mm dia. Brass sensor/ electrode duly wired with nuts & bolts complete (Set of 3 Nos)
Supplying & erecting minimum three & above star rated Centrifugal water pump (Monoblock), 415 V, three phase 50 cycles A.C. supply of 7.5 KW/10 HP with discharge 1150/600 Litres per Minute (LPM) for head of 24/69 m and 65 mm suction/ 50 mm delivery pipe of size, on provided C.C. foundation as per specification No. WP-CGP
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 28-42 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 5.625 KW/7.5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 57 to 22 m and discharge from 120 to 900 litres. . per minute & pipe of Suction 75 mm/Delivery 65 mm diameter erected with necessary H type clamps as per specification No. WP-OSP
Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .
SITC of Triplex Lift control system for three nos. microprocessor / PLC - based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication /control / data cabling laying in rigid PVC conduits / trunking etc. complete.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.
Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OHPL/HM (excluding luminaries)
Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TP contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete.
Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast).
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multistra nded copper Industrial cable for voltage grade up to 1.1 kV
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Supplying and erecting integrated LED flood light fitting Max. 155W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 18600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench / pipe as per specification no. CB-LT/AL
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following : - (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump (MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears:
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting ISI mark GI pipe 32 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting ISI mark GI pipe 40 mm. dia ‘C” class position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting ISI mark GI pipe 50 mm. dia ‘C” class position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.
Supplying and erecting 75/80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 75/80 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting 50 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and installing one piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FFFFA/NZ
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FMC
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no.FF-FFA/ACT
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
13-8-14 Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Supplying, installing, testing, and commissioning of portable fire extinguishers of ABC dry powder stored pressure type fire extinguishers of 6 Kgs. capacity Complete with standard discharge valve with tube, CI bracket for wall mounting etc. complete as per confirming to IS: 15683 complete all the work upto the satisfaction of the Engineer in charge.
Supplying, installing, testing, and commissioning standard response Pendent / Upright type sprinkler (Standard coverage) quartzite bulb type with 15mm screwed end connection of 68 deg. C.tempersture rating K-80 and orifice shall not be less than 6mm sprinklers shall be UL listed approved with chrome finished. complete all the work up to the satisfaction of the Engineer in charge.
Supply and Installation of CP Brass, 15mm inlet spray pattern, open standard response sidewall type sprinkler heads with quartzoid bulb with temp rating of 79 deg. C .K value of sprinkler shall be 80, Sprinkler head shall be UL approved.
Providing and fixing in position statutory Signage's made out of 3mm thick opaque PVC foam board, machine cut, non reflective, auto glow (type & Make), with silicon adhesive for safe evacuation of occupants in case of emergency. Sign indicators should be provided at prominent places as per Fire Provisional NOC (As per - IS-9457, IS-12349, IS-12407). complete all the work up to the satisfaction of the Engineer in charge.
Providing, laying, testing & commissioning of 80mm dia resilient rubber neoprene lined single arch Vibration eliminators (Expansion bellows) suitable for Design Pressure 16 kg/sq cm and test pressure 24 kg/sq cm. complete all the work up to the satisfaction of the Engineer in charge.
Providing, laying, testing & commissioning of 150mm dia resilient rubber neoprene lined single arch Vibration eliminators (Expansion bellows) suitable for Design Pressure 16 kg/sq cm and test pressure 24 kg/sq cm. complete all the work up to the satisfaction of the Engineer in charge.
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete.
Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.
Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/SD .
Supplying, installing, testing and commissioning of intelligent addressable thermal / heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, erecting testing and commissioning multi sensor heat detector with smoke and heat combination (RoR + fix temperature) with base on back box, necessary connections complete as per specification no. FF-FAS/HD
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable fire ontrol/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54/FM or UL Listed with 3 yrs equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With PVC accessories on wall /ceiling as per specification No: WG-MA/CON.
Supplying and fixing 17U floor mount rack (Dimension-DxWxH – 800x600x954mm) as per specification No. WG-NAS/RAK
Supply, installation, testing & commissioning of 6 Watt Cone type Ceiling Mounted metal grill Speakers with line matching transformer, Power tapping: 1.5W/3W/6W, Frequency response: 100-20000 Hz. SPL (1W 1m) 92 dB, including screw clamp mounting with required accessories. (Colour - White)
Supply, Installation, testing and commissioning of 6 Watt Box type Wall / Surface Mount Speaker with line matching transformer, Power tapping: 1.5W/3W/6W, ABS or metal body, Frequency response: 100-20000 Hz. SPL (1W 1m) 92 dB, including required mounting accessories.
Supply, Installation, testing and commissioning of 10 Watt column/wall mount Projector Speaker (uni directional) with line matching transformer, Power tapping: 5W/10W, fire protected ABS or Metal cabinet, includes a steel U-bracket, with adjustable inclination and easy installation with required accessories.
Supply, installation, testing & commissioning of 8 Zone Voice Alarm PA Controller with built in audio message generator (multi message), 6 Zone 70/100V live outputs for Speaker circuit, Fireman Microphone, Pre-recorded evacuation messages, Should be able to send 2 different pre-recorded messages simultaneously (message should be in 2 languages English & Hindi), Phased evacuation, 6 supervised input contact relays for integration with Fire Alarm Control Panel, Up to 6 call stations can be connected together with controller. The controller should integrates multiple functions such as audio storage, playback, zone control, audio monitoring, scheduled broadcast and fault diagnosis, audio playing, zone control, fault monitoring, log recording, volume control and amplifier switchover etc. complete with cords, connectors & required accessories.
Supply, installation, testing & commissioning of 480 Watt, high efficiency Power amplifier, 70/100V loudspeaker output voltages, RMS output power limiter, high temperature, DC, short circuit, mains undervoltage protection, DC supply undervoltage protection, inrush current limiter with cords, connectors, power supply & required accessories.
Supply, installation, testing & commissioning of Audio Music Player with built in USB port, SD card, support MP3 & other audio formats, complete with cable, cords & required accessories.
Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit
Supplying and erecting PVC box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX .
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying & erecting 50 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW
Supplying and erecting 5m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC
Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, core dia 50/125 μm (OM3), suitable upto 10 GBPS, ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-COC/OFC LSZH
Supplying and plugging 3 m fibre patch cord LC-SC MM (50) OM3 LSZH duplex complete as per specification no. WG-COC/FPC
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete
Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete.
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WGNWC/GBS
Supplying, fixing, and configuring 24 ports + (4 SFP+) POE switch, 370W, 6KV surge protection on ethernet port and console port for management on provided rack as per specification No. WG-NWC/ENS
Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying and fixing Tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 12 ports light guide unloaded interconnect unit,rack mounted type, with adapter panel for termination of optical fibre cables in provided U rack complete as per specification no. WG-NAS/ LIU
Supplying and fixing SC/LC type multimode pigtails (OM3) for LIU to terminate OFC in LIU as per specification No. WG-NAS/LIU2
Supplying and fixing Power Distribution Unit for networking rack comprises of 6/16A (6 Nos. sockets), 25 A modular MCB, appropriate rating fuse and indicator lamp, enclosed in black powder coated metal with necessary arrangement for fixing as per specification No. WG-NAS/RAK
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x767 mm) as per specification No. WG-NAS/RAK
Supplying and fixing 42U floor mount server rack (Dimension-DxWxH – 800x600x1866 mm) as per specification No. WG-NAS/RAK
Supplying and fixing dual-band manageable wireless 3x3 Mesh Router, high performance, 802.11 n/ac unified, concurrent access point with POE in networking as per specification no. WG-NAS/LAP2
Supplying, installing and activating physical license pack software for multiple access point with management, configuration and trouble shooting for all access point in network complete.
Supplying and installing, testing & commissioning of Digital (Hybrid) type EPABX of 10 Digital + 250 analog extensions, built in Compatible Software Server, USB Ports, internal Storage upto 64GB, Group Conference facility. Voice Messages, ethernet ports, Universal Slots for Interface expansion Cards, Single Line Analog Telephones port, Trunk line, BRI ports, GSM/3GPorts, SIP Trunks port complete with required accessories. (Make- Matrix / Panasonic / Alcatel or equivalent)
Supply, installation, testing & commissioning of Ceiling Mounted Smart LED Projector- Full HD, 1920 x 1080 Resolution, 3800 ANSI Lumens white/color output, Varifocal lens, 16 watt audio output, 10000:1 contrast ratio, Built-in wireless and miracast, HDMI 2 inputs, VGA, 6000 hours unwoven filter, 12000 hours lamp life, HDCR/Accentualizer, RJ-45 port, including Remote control, power cord, cable, lens cover & required accessories with Ceiling mounted brackets.
Supply & fixing of 150" Diagonal Motorized white Screen for projector with motor, fixing brackets & required accessories.
Supply, installation, testing & commissioning of Smart TV, Wall mount 55" Ultra HD Flat LED TV having minimum 2 HDMI, 2 USB & 1 RJ 45 port, AV port with inbuilt Wi-Fi including wall mount accessories.
Supplying, Erecting, Testing & Commissioning 5 MP Full IP Dome/Bullet Camera Complete. Camera Sensor 1/2.7", 5.0 megapixel, progressive scan, CMOS Lens [email protected] Distance 60 Meter Detect Shutter Auto/Manual, 1 ~ 1/100000s Colour: 0.01Lux (F2.0, AGC ON)Minimum Illumination 0Lux with IR on Digital noise reduction 2D/3D DNR Day/Night IR-cut filter with auto switch (ICR)S/N >52dBIR Range Up to 30m (98ft) IR range Wavelength 850nmIR On/Off Control Auto/Manual Defog Digital Defog WDR DWDR Video Compression Ultra 265, H.265, H.264, MJPEGH.264 code profile Baseline profile, Main Profile Frame Rate Main Stream: 5MP (2592*1944), Max 20fps; Sub Stream: 720P (1280×720), Max 20fpsVideo Bit Rate 128 Kbps~16 Mbps OSD Up to 4 OSDs Privacy Mask Up to 4 areas ROI Up to 2 areas Motion Detection Up to 4 areas Image White Balance Auto/Outdoor/Fine Tune/Sodium Lamp /Locked/Auto2Digital noise reduction 2D/3D DNR Smart IR Support Flip Normal /Vertical/Horizontal/180°Dewarping NAHLC Supported BLC Supported Network Protocols IPv4, IGMP, ICMP, ARP, TCP, UDP, DHCP, RTP, RTSP, RTCP, DNS, DDNS, NTP, FTP, UPnP, HTTP, HTTPS, SMTP, SSL, QoS Interface 10/100M Base-TX Ethernet Compatible Integration ONVIF (Profile S, Profile T), API Certifications CE: EN 60950-1/UL: UL60950-1/FCC: FCC Part 15(Include – 12 Month Fully Compressive Warranty
Supply of 64 Channel professional series 4K HD Network Video Recorder Smart H265+/H265/Smart H264+ Max 320Mbps Incoming Bandwidth upto 12MPResolution for Preview and Playback. Bit Rate 16Kbps-20Mbps per channel. 2HDMI/2VGA simultaneous video output to enhance the storage liability when the network break down, Quad- Core embedded processor. 8 STATA III Ports upto 6 TB for each HDD for 2 RJ45 port (10/100/1000Mbps) independent of joint Networking. Analytical Features like - ANPR, People Count, Face Detection, Missing/Abonded Objects, Tripwire and Intrusion alarms, Smart FAN to achieve high cooling effects. Automatic Network Replenishment (ANR) Technology - Network Video Recorders with ANR function automatically store video data on an IP camera SD card when the Network is disconnected. After recovery of the network, the NVR automatically retrieves the video data stored on the camera.
Supply and Installation of 8 TB (7200 RPM) Surveillance hard disk 8 TB storage capacity with SATA support 6GB/s NCQ 64 MB cache 3.5 inches. (for 30 days recording)
Supplying, installing, testing & commissioning cassette type room Air conditioning unit 2.8TR to 3.3TR capacity with refrigerant R32/R410A 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, dust filter, noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying, installing, testing & commissioning cassette type room Air conditioning unit 3.4TR to 3.9TR capacity with refrigerant R32/410A 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, minimum dust filter, noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying, erecting, testing and commissioning of 7HP to 8HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
Supplying, erecting, testing and commissioning of 10HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
Supplying, erecting, testing and commissioning of 12HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
Supplying, erecting, testing and commissioning of 18HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56°C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type room / indoor unit (IDU) of nominal capacity 1.8TR (594 cfm) to 2.2TR (655cfm) having EER asper BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, inbuilt drain pump, expansion device, cordless remote control with necessary controls with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting. The indoor unit shall also have an electronic control console. The unit shall be suitable for wall mounting and provided with suitable mounting brackets with any additional refrigerant and oil charge as per requirement during installation complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 way cassette room / indoor unit (IDU- compact / standard size) of nominal capacity 4.1TR (1218 cfm) to 5.0TR (1624cfm) having EER asper BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant piping, cordless remote control and fresh air post etc. IDU shall have anti-corrosive coating suitable for coastal area in all respetcs suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation complete.
Supplying and installatiing of high pressure grade required size copper connection Y or T - joints / refnet complete erected on wall/ ceiling with supports/raceways, nitrile rubber insulation, painting, etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditing system,
Supplying and erecting aluminium powder coated exhaust air grille with call damper for toilet exhaust of 150x150 mm having matching colour with the existing false ceiling
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6mm dia. (OD) for liquid line / suction line of suitable gauge ( hard pipe for liquid main line and soft copper pipe for refrigerant along with necessary supports, hanger,s clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damage,s fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV / VRF air conditioning system complete.
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia. (OD) for liquid line / suction line of suitable gauge ( hard pipe for liquid main line and soft copper pipe for refrigerant along with necessary supports, hanger,s clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damage,s fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV / VRF air conditioning system complete.
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9mm dia. (OD) for liquid line / suction line of suitable gauge ( hard pipe for liquid main line and soft copper pipe for refrigerant along with necessary supports, hanger,s clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damage,s fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV / VRF air conditioning system complete.
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5mm dia. (OD) for liquid line / suction line of suitable gauge ( hard pipe for liquid main line and soft copper pipe for refrigerant along with necessary supports, hanger,s clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damage,s fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV / VRF air conditioning system complete.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, rivetin (Ducting = 24G )
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supply, installation, testing and commissioning of Vane Axial lift Staircase pressurization fan complete with direct drive and Supports system with vibration isolators. F Class motor,Motor shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase AC supply and shall have high efficiency motors, smoke sensors based auto operation DOL starter/control panel with power and control cabling, with all supporting structures and accessories, waether proof external intake louvers. Sound level shall not be more than 55 dBA from 3 m AMCA Certified only. Capacity = 17000CFM / 25mmWg
Supply, installation, testing and commissioning of Vane Axial lift well pressurization fan complete with direct drive and Supports system with vibration isolators. F Class motor,Motor shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase AC supply and shall have high efficiency motors, smoke sensors based auto operation DOL starter/control panel with power and control cabling, with all supporting structures and accessories, waether proof external intake louvers. Sound level shall not be more than 55 dBA from 3 m AMCA Certified only. Capacity = 11000CFM / 25mmWg
Supplying, erecting, testing & commissioning exhaust air system, ductable circular inline exhaust air fan inlet unit having 600 cfm capacity with maintaining the static pressure minimum 30mm suitable to operate on 1ph, 230 V, 50Hz, A.C. supply complete.
OMKAR CONSTRUCTION
Shubham EPC Private Limited
S S SATHE INFRA PRIVATE LIMITED
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid