Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC HNO 365 STREET NO 12 TALAB TILLO JAMMU RISHI TRADING CO TALAB TILLO ROAD OPP FRIENDS LANE JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹7.6 L+₹58,223 (8.32%)Rejected-Finance | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹8.6 L+₹1.6 L (23.5%)Rejected-Finance JHARIA BENIGANJ HARDOI | BENIGANJ | HARDOI | UTTAR PRADESH | L3 | Rejected-Finance 3rd Lowest |
Tender Value
Refer Docs
EMD Value
₹7,000
Closing Date
18 Apr 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER
ELECTRICITY URBAN DISTRIBUTION CIRCLE, BUNGLOW NO.-9, OLD POWER HOUSE COLONY, RAILWAY STATION ROAD, GORAKHPUR
WORK AGAINST SANCTIONED PACKAGE
2022_PVVNV_686923_1
06/EUDC(G)/2022-23
Open Tender
Electrical Works
Lump-sum
90 days
AREA OF EUDD-I GKP
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SUPERINTENDING ENGINEER EUDC
₹7,000
25 May 2022
11 Apr 2022
19 Apr 2022
11 Apr 2022
18 Apr 2022
11 Apr 2022
180 days
Amount
fo|qr uxjh; forj.k [k.M&izFke xksj[kiqj ds vUrxZr tek ;kstuk esa Lohd`r iSdst la[;k 46@2021&22 ¼ftyk fpfdRlky; xksj[kiqj esa ih0,l0,0 vkWDlhtu la;a= dh LFkkiuk gsrq 125 fd0ok0@139 ds0oh0,0 ds vko';d fo|qrhdj.k dk dk;Z½ ds dk;ksZ dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %&
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
ST Pole 9 meter long.
ST Pole 11 meter long.
ACSR Dog Conductor
33 KV Polymer Disk insulator with fitting
33 KV Fuse set complete
33 KV structures for Fuse set
33 KV Bus Isolator 400 Amp
33 KV Structure for Bus Isolator
33 KV Line Isolator
33 KV Line Isolator Structure
33 KV Lightening Arrestor
Structure for 33 KV Lightening Arrestor
33 KV Post Insulator
33 KV Post Insulator Structure
33 KV Top Channel 125x65x3200mm
33 KV Dropper angle 100x50x2600
LT AB Cable (3x120+1x95+1x16)sq mm
LT PVC cable (1x400)mm
Copper control cable 4x2.5 mmsq (Armoured)
Copper control cable 2x2.5 mmsq (Armoured)
24V Battery and battery charger wirh cabinet
Stay complete with 5 kg wire
Earthing complete
33 KV VCB with Single T/F Control panel and CT 200/100/1 A with Structure [1-33KV VCB, 2- Control Panel I/C for 33 KV single T/F, 3- CT 200/100/1-1A, 4- Steel Structure for CT and VCB]
Supply of following material/fitting complete in all respect :-
PG Clamps for ACSR DOG Conductor
Suspension clamp with I hook (insulated)
Dead end clamp with I hook (insulated)
Z-Clamps copper
Aluminium crimping lugs for LT side
Aluminium crimping lugs for HT side
Clamps for top channel Dropper angle etc.
Nuts & Bolts of different sizes.
T-Connectors,lugs (ACSR Dog) etc
The excavation of 2 No foundation pit of size 750mmX450mm and having depth of 1/6th of the full length of the pole. Fabrication & erection of double Pole with fixing of necessary clamps & accessories (Top Channel, Dropper Angle etc.) as per required. All required materials such as Holding clamp/STP clamp, Nuts & Bolts off size etc will be provided by the contractor. Grouting of Pole in cc 1:4:8 (Cement, sand & 40 mm brick ballast), Grouting will be done in the block of size 450x450 mm x depth upto ground level and backfilling of pits with mud completely and leveling etc (Material provided by Contractor). Making plinth around Pole height 300 mm above ground level with top 100 mm is kept tapered so that No rainwater gets accumulated on the top. All work will be done as per RESPO Norms & relevent IS Specification.
The excavation of foundation pit of size 750mmX450mm and having depth of 1/6th of the full length of the pole. Fabrication & erection of ST Pole with fixing of necessary clamps & accessories as per required. All required materials such as Holding clamp/STP/LT clamp, F-Bracket, LT shacle insulator, Nuts & Bolts off size etc will be provided by the contractor. Grouting of Pole in cc 1:4:8 (Cement, sand & 40 mm brick ballast), Grouting will be done in the block of size 450x450 mm x depth upto ground level and backfilling of pits with mud completely and leveling etc (Material provided by Contractor). In case of ST Pole making Plinth around Pole height 300 mm above ground level with top 100 mm is kept tapered so that No rainwater gets accumulated on the top. All work will be done as per RESPO Norms & relevent IS Specification.
Digging out old 33 KV cable in switchyard and again Re-laying of 33 KV XLPE Cable as per RESPO Norms.
Laying, stringing, sagging, binding and jumpering of ACSR Dog conductor for HT Line with fixing of clamps and nuts&bolts off size as per required.
Installation, commissioning & Testing of 33 KV VCB with single T/F control panel and CT 200/100/1A with structure including making plinth and foundation of VCB. Complete all connection in all respect.
Installation, commissioning & Testing of 33 KV Bus isolator (400 Amp) along with its structure including making plinth and foundation of Bus isolator structure. Complete all connection in all respect.
Installation, commissioning & Testing of 33 KV Line isolator along with its structure including making plinth and foundation of Line isolator structure. Complete all connection in all respect.
Installation, commissioning & Testing of 33 KV Post isolator along with its structure including making plinth and foundation of Post isolator structure. Complete all connection in all respect.
Painting of Pole by double coating Aluminum & Red oxide paint. Paint will be provided by contractor
Earthing of ST Pole by MS earthing Rod & 6 SWG earthing Wire as per RESPO Norms.
Painting of Substation Structure & equipment
Errection of 33 KV Lightening Arrestor alongwith structure
Installation of 33 KV Fuse set along with structure
Fixing of control cable 4X2.5 sq.mm. (Armoured) for suitable to VCB with complete connection in all respect
Fixing of control cable 2X2.5 sq.mm. (Armoured) for suitable to VCB with complete connection in all respect
Erection and grouting of stay in CC ratio 1:4:8 of Cement, Sand and Stone Ballast including cost of grouting material with Nozelling and binding of stay wire (Complete work)
Construction of T/F plinth of size 2x2x1.2 M with the help of first class brick & 9" masonary in the ratio 1:4 cement & sand coarse. Filling the structure completely and plastering outer surface as per RESPO Norms. Top of the plinth covered with 4" RCC Slab of ratio 1:1.5:3 (Cement, sand & concrete) grouting with 2 No ISMC size 125X65X6 MM (confirming to IS 808:1989) of 2000 mm long for resting. All required materials will be provided by the contractor.
Fabrication, errection, commissioning & Testing of existing T/F on Plinth with all accessories including make its LT and HT connection. All neessary materials will be supplied by the Contractor.
Chemical earthing of Transformer (Body+Neutral) as per IS Code 3043 - 1987 specification (Materials will be provided by contractor)
Earthing of Switchyard (Outdoor) equipments as per IS Code 3043 - 1987 specification
Laying, stringing, sagging, binding and jumpering of LT ABC (3x120+1x95+1x16) Sq.mm. Cable of LT Line with fixing of Distribution Box with Clamp, Insulated Dead end clamp with I hook, Suspension clamp with I hook(Insulated), LT insulated Piercing connector, XLPE 1X35 Sq.mm. Al. cable for enerzing DB, etc.
Renovation (Repairing/Plastering/Painting of damaged wall) of an existing old meter room and making way facing towards the main road in the room for the installation of entry gate which should be made up of an iron sheet size (3.5X6) ft.
Fencing of Switchyard (Construction of foundation i.e fencing base boundary wall of size (42X25X2) ft with the help of first class brick & 9" masonry in the ratio 1:4 cement & sand coarse. After that Grill fencing of Switchyard shall be made of (42X25) ft of size & height approx 4 ft as per site requirement with fabrication 50X50X5 mm angel the frame is also have 1 No Horizontal runner of MS flat 40x5 welded in middle to support of grill, having a gate on road side must have provision of locking arrangement. The work is including painting of fencing as per norms. Work will be done as per RESSPO specification.
Construction of Fire protection wall/Partition between Transformers of size (2.5X4.5) mtr with the help of first class brick & 9" masonry in the ratio 1:4 cement & sand coarse.
Cemented Flooring of Switchyard as per norms size (42X25) ft & (42X48) ft.
Manish Traders
M/s Anil kumar singh
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .