| 1 | L1₹1.8 CrAccepted-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹1.8 Cr | L1 | Accepted-AOC Being lowest and reasonable. |
| 2 | L2₹1.8 Cr+₹5,512.78 (0.03%)Rejected-Finance | ₹1.8 Cr+₹5,512.78 (0.03%) | L2 | Rejected-Finance Other than lowest. |
| 3 | L3₹2.0 Cr+₹12.1 L (6.59%)Rejected-Finance 126 NARANG COLONY JANAKPURI NEW DELHI 110058 | WEST | DELHI | 110058 | ₹2.0 Cr+₹12.1 L (6.59%) | L3 | Rejected-Finance Other than lowest. |
| 4 | L4₹2.0 Cr+₹15.7 L (8.50%)Rejected-Finance RZ 31 222 J BLOCK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹2.0 Cr+₹15.7 L (8.50%) | L4 | Rejected-Finance Other than lowest. |
| 5 | L5₹2.0 Cr+₹18.9 L (10.2%)Rejected-Finance | ₹2.0 Cr+₹18.9 L (10.2%) | L5 | Rejected-Finance Other than lowest. |
Tender Value
₹2.4 Cr
EMD Value
₹3.1 L
Closing Date
1 May 2023, 6:00 pmClosed
HQ Chief Engineer Delhi Zone Delhi Cantt-10
HQ Chief Engineer Delhi Zone Delhi Cantt-10
SPECIAL REPAIR TO BLDG NOS P-64 P-199 P-200 P-201 P-202 P-203 AT COD UNDER GE NORTH DELHI CANTT-10
2023_MES_588066_1
CA No CEDZ/TOKEN-09 of 2023
Open Tender
Civil Works
Item Rate
270 days
Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹2,000
GE North
₹3.1 L
Yes
16 May 2023
3 Apr 2023
3 May 2023
3 Apr 2023
1 May 2023
24 Apr 2023
5 Apr 2023 - 12 Apr 2023
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic digital coloured tiles 7 to 8 mm thick joint free area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement. including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for double charged Vitrified coloured dark shade tiles of 8-10 mm thick (square/rectengular) polished, joint free area of each tile exc 0.18 sqm but n. exc 0.38 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the surface including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
Ditto- item No. 3 above but as in vertical surfaces such as skirting/ dado over and including 10 mm thick rendering in CM (1:4) complete all as specified and directed.
M&L glazed digital vitrified tiles (DVT) colour and shed as approved in vertical surface of size 600x300x7-8 mm thick with highlighter set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface incl rendering 10mm thick in CM (1:4) and finished rough, complete all as spd & directed.
Taking down chowkhats or frames n.exc 1.50 sqm with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats of frames exc 1.50 sqm but n. exc 4.0 sqm with shutters (without taking off shutters from the frames)complete all as specified and directed.
S & F Roll forming double shutter (glazed shutter and mesh shutters ) steel windows and ventilators with guard bars, fabricated from roll formed sections made galvanised steel sections colour coated/ powder coated sections including 4mm thick plain glass in glazing for glazed shutter and stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.40 mm complete for gauzed shutters, including two coat of synthetic enamel paint over a coat of red oxide on steel surface, all fitting and fixtures complete all as specified and directed.
S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar including fixing cantilever brackets connecting union to pipe and 32mm dia GI pipe duly painted upto Nahani Trap or Floor trap complete as directed at site, overall size 915mmx460mm bowl size 410mm x 330mm x160mm complete all as specified and directed.
S&F in repairs CP mixer for sink chromium plated, screwed down high pressure, mixing 'Hot' or 'Cold' water with long screwed shanks and fly nuts, screwed for iron pipe and fixed of bore dia 15mm complete all as specified and directed.Make :- Jaquar/Cera/Kohler
S&F aluminium powder coated three track window (two shutters glazed & one shutters wire gauge) with frame, glazed with 4mm thick tinted glass and wire guage with stainless steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.40mm including rubber bead joining cleat for fixing in position, concealed type lock for all three shutter, PVC roller etc all as specified below:- (a) Frame (top & side) section shall of size 92.00x31.75x1.50mm. (Section No 21447) (b) Frame (bottom) section shall of size 92.00x31.75x1.50mm. (Section No 21446) (c) Top & side members of shutter section shall be of size 18.00x40.00x1.50mm. (Section No 21455) (d) Interlock Section of Shutter shall be of size 18.00x40.00x1.50mm. (Section No 21454) (e) Bottom Members of shutter section shall be of size 18.00x40.00x1.50mm. (Section No 20844)
M&L for chipping of spalled and loose concrete and cleaning rust from re-inforcement by sand brushing scrubing down concrete surfaces with wire brushes cleaning with water allowed to dry applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bonding coat of a layer of epoxy adehessive on complete exposed surfaces of concrete and provide guniting over steel welded mesh 2 mm dia of wire and total aperture 75 mm, thickness of gunite n.exc 25 mm thick (average thickness) using cement mortar 1 :3 with OPC 43 grade cement mixed with polycrete admixture @ 2 % by wight of cement or as per manufactures instructions and finally applying cement plaster over gunite surfaces of required thickness to give an even uniform and smooth finish conforming to proper Geometrics in cement mortar 1:4 to match with the existing surface as in side and soffits of slabs,chajjas,fins,facias ,parapets ,columns and beams etc complete including necessary scaffolding ,shuttering necessary chased to brick work or RCC members at any height upto four storey buildings incl removing of small trees shrubs etc all as specified(Note: steel welded mesh to be welded with the existing reinforcement. The cost of welded meshis to be welded with the existing re-inforcement is deemed to be included in the quoted rate complete all as specified and directed.
M&L for preparing new plastered surfaces of ceiling and applying two coats of Oil bound distemper complete all as specified and directed.
M&L two coats of oil bound distemper on surface of ceiling including preparation of old plastered surface complete all as specified and directed.
S&F factory made single extruded WPC (wood polymer composite ) solid decorative door frame ofsize 50 X 100 mm comprising of virgin PVC polymer of K value 58-60 (suspension grade ) , calcium carbonate and natural fiber (wood powder/rice husk /wheat husk ) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS Screws having minimum frame density of 650 kg/cum and screw withdrawal strength of 2200 N (face ) & 1100 N (Edge ),minimum compressive strength 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardent and fixed in position with MS hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engr-in-charge ( Note : For WPC Solid door minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable.variation in profile dimensions on plus side shall be acceptable but no extra payments on this account shall be made )
S&F factory made single extruded WPC (woodpolymer composite ) solid decorative type flush door shutter of 35 mm size comprising of virgin polymer of K value 58-60 (suspension grade ), calcium carbonate andnatural fiber (woodpowder/rice husk /wheat husk ) and non toxic additives (maximum toxicity indexof 12 for 100 gms ) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (face ) & 900 N (Edge ),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardent. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both face of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws ,all as per direction of Engr-in-charge. ( Note : stainless steel butt hinges shall be paid seperately )
S&F 150 mm long Stainless steel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 75mm long stainless steel butt hinge in WPC doors with screws complete all as specified and directed.
S&F Stainless steel handles 125 mm size for WPC door with screws complete all as specified and directed.
S&F 250 mm Stainless steel sliding door bolt plate type and fixing clips of sheet, and fixing bolts and sliding bolts and fixed complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed to floor of size 140 mm complete all as specified and directed.
S&F 35 mm thick second class hardwood glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered beads for securing glass/ gauge complete all as specified in SSR Pt I-1991 section 8 clause 8.24 (a) and as directed.
M & L applying two coats of synthetic enamel paint on new wooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and directed.
M&L for two coats of synthetic enamel paint on old wooden painted surfaces including preparation of surfaces of any description not otherwise descriped over 10 cm width or girth complete all as specified and directed.
S&F stainless steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.40 mm, fixed with stainless steel wire staples beads, tinned tacks to wooden doors shutters complete all as specified & directed.
Supply and fix to chowkats 2nd class hard wood Plain, framed, panelled shutters 35 mm thick (any number of panels), with panels of timber flat on both sides (feather edged), or of plywood medium density , 12 mm thick plywood complete all as specified and directed.
S&F 200 mm long Stainless steel tower bolts of extruded section and fixed complete all as specified and directed.
S&F butt hinges, 100 mm size medium weight, cold rolled mild steel complete all as specified and directed.
S&F Stainless steel handles 150 mm size complete all as specified and directed.
S&F 300 mm Stainless steel, sliding door bolt plate type, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
S&F in repairs stainless steel chromium plated curtain rods 25 mm dia incl fancy type CP brackets wall to wall or flush to wall ), with both side end knobs/lattu as approved for securing to curtain rod , complete all as specified and directed.
Taking down cement or cement plaster on brick walls/ceiling etc including raking out joints, hacking for key, scrubing down with water etc complete all as specified and directed.
M&L 15 mm thick Ready mix plaster (Make:- Ultratech readiplast /Birla Aerocon RMP /ACC Suraksha RMP ) on brickwork or concrete surfaces of wall (internal surface )finished even and smooth incl necessary scafffolding upto 12.0 m height complete all as specified and directed (Working height upto 12 m ) complete all as specified and directed.
M&L preparation of newly plastered surface on walls and applying 1.50 mm thick wall care putty and 2 coat of OBD over a one coat of primer complete all as specified.
M&L for preparation of old surface after complete removal of existing treatment applying 1.50 mm thick wall care putty and making the surface smooth and applying two coat of oil emulsion distemper over a coat of primer complete all as specified & directed.
M&L 15 mm thick Ready mix plaster (Make:- Ultratech readiplast /Birla Aerocon RMP /ACC Suraksha RMP ) on brickwork or concrete surfaces of wall (external surface )finished even and smooth incl necessary scafffolding upto 12.0 m height (Working height upto 12 m )complete all as specified and as directed by engr-in-charge.
M&L Water proofing treatment walls of bathroom consisting of the following operation including demolition/taking down old treatment :- (i) Cleaning of surfaces by wire brushing brooming removing dust particles (ii) Filling of all brick joints with cement mortar 1:4 (iii) Applying a coat of Chemical Dr fixit Pidifin 2K (iv) applying fiber mesh setting with chemical Dr fixit Pidicrete URP (v) final coating with Pidifin 2K and sprinking of sand (vi) After the surface dried, plaster the surface with ready mix plaster 15 mm thick. (Note All water proofing treatment will be executed by the approved authorised representative).
M&L for finishing walls with applying plaster of paris putty of 1mm thickness over plastered surface to prepare the surface even and smooth and applying acrylic smooth exterior paint of required shade on New work (Two or more coat applied @ 1.67 ltr/10Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm complete all as specified & directed.
M&L Water proofing treatment on sunken floor consisting of the following operation including demolition/taking down old treatment :- (i) Cleaning of surfaces by wire brushing brooming removing dust particles (ii) M & L PCC 1:2:4 type (B0) using 12.5 mm graded stone aggregate 50 mm thick, finishing the surface even and smooth without using extra cement (iii) Applying a coat of Chemical Dr fixit Pidifin 2K (iv) applying fibe mesh setting with chemical Dr fixit Pidicrete URP (v) final coating with Pidifin 2K and sprinking of sand (vi) After the surface dried, screeding the surface with Ready Mix Plaster 15 mm thick including finishing even and smooth using extra cement. (Note All water proofing treatment will be executed by the approved authorised representative).
M&L for lean concrete 1:5:10 with broken brick aggregate in sunken of gauge n exc 63mm deposited spread and levelled in layers n exc 15 cm thick hand rammed to a true surface complete all as specified & directed.
Taking down brick tiles,terracing tiles or single layer APP from roof laid, bedded and pointed in any mortar complete all as specified & directed.
Demolition of mud phuska/cement concrete in roof any thickness, including plaster and leaping/whether full thickness removed on only a part thereof complete all as specified & directed..
M&L 40 MM thick cement concrete type B-1, 1:2:4 (20 MM graded aggregate) as in padding over roof complete mixed with water proofing compound (WPC shall be paid seperately) complete all as specified & directed.
M&L for water proofing treatment on roof slab consisting with following operations:- (i) Existing surface shall be cleaned of all dust, fungus, moss and other foreign material etc by using wire brush & dusting, Apply a layer of bituminous primer conforming to IS 3384 @ 0.4 Ltr/Sqm on the surface. Laying 3mm thick APP membrane having non-woven polyester matt at core and under surface coated with plastic polythene film. Laying shall be done using butane torch maintaining 100mm side overlap & 150mm end overlap, sealling all overlaps complete including treatment at all junctions & corners. The membrane shall be tucked into groove on vertical plane and groove sealed with cement mortar. The treatment shall be provided upto 200mm height above finished floor (Note- The membrane shall have tensile strength of 700N/5cm in longitudinal direction and 450N/5cm in transverse direction at 23 degree celcius, Flow resistance>120 degree celcius, dimensional stability, < 0.5% when tested as per ASTM D 5147. The laying of the membrane shall be done through authorized applicator of the manufacturers' (ii) Again applying hot bitumen 85/25 @ 1.2 Kg per Sqm over water proofing membrane. (iii) Dusting dry sand @ 0.75 Kg per Sqm and applying two coat of silver paint over the membrane. (iv) Prepration of surfaces and applying two coat of aluminium solar reflective paint of complete surfaces.
M&L for water proofing treatment on roof slab consisting with following operations:- (i) Existing surface shall be cleaned of all dust, fungus, moss and other foreign material etc by using wire brush & dusting, Apply a layer of bituminous primer conforming to IS 3384 @ 0.4 Lit/Sqm on the surface. Laying 3mm thick APP membrane having non-woven polyester matt at core and under surface coated with plastic polythene film. Laying shall be done using butane torch maintaining 100mm side overlap & 150mm end overlap, sealling all overlaps complete including treatment at all junctions & corners. The membrane shal be tucked into groove on vertical plane and groove sealed with cement mortar. The treatment shall be provided upto 200mm height above finished floor (Note- The membrane shall have tensile strength of 700N/5cm in longitudinal direction and 450N/5cm in transverse direction at 23 degree celcius, Flow resistance>120 degree celcius, dimensional stability, < 0.5% when tested as per ASTM D 5147. The laying of the membrane shall be done through authorized applicator of the manufacturers' (ii) Again applying hot bitumen 85/25 @ 1.2 Kg per Sqm over water proofing membrane.
M&L for precast cement concrete tiles 250 mmx250 mm x22mm thick with grey cement and pigment machine pressed set jointed and pointed in neat cement slurrry laid over and including cement mortar screed 15mm thick in CM 1:6 mixed with water proofing compound and jointed pointed in CM 1:3 mixed with 5% crude oil by weight of cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified & directed.
S&F in repairs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, ISI marked, three layered hoisted and fixed in position including connecting up pipes complete all as specified & directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilatate demolition) of any description and in any position not otherwise specially provided and removal of debris and rubbish out side MoD land complete all as specified and directed.
S&F FRP (fiberglass reinforced plastics ) chajja 4 mm thick of fibreways or equivalent in required colour size and design made by resin transfer moulding (RTM ) machine technology having smooth gradual slope curvature for easy drainage of water and duly reinforced by 2 nos vertically and 1 nos horizontally 50x2 mmthickM.S. flat with 12mm in built hole for grouting on the existing wall along with the 50 mm flanges duly inserted and sealed in the wall complete in one single piece casted monolithically including all necessary fitings. The FRP Chajja should be manufactured using unsaturated poyester resin as per IS:6746 duly reinforced with fiberglass chopped strand mat ( CSM) as per IS : 11551 complete with protective gelcat U/V coating on top for complete resistance from the extreme of temperature , weather & sunlight . NOTE :- All the gaps are sealed using silicon sealant from top and bottom to make it water proof incl grouting in existing wall and fitting with suitable screws and fixtures upto 3rd floor level incl all labour material tools and plants , scaffolding safety arrangements quality checks complete in all respect all as specified and directed .
Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
M&L Granite 18-20 mm thick colour as approved ( of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shed of granite over 15mm thick screed bed in cement mortar 1:6) including moulding and polishing the edges all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
M&L Mild steel conforming to Fe 410-0 or Fe 310-0 in framed work such as grills, gratings, ladder, hinges, door frame, desert cooler stand etc with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; ladders; railings, coolar stand and similar work complete all as specified and directed.
M&L applying two coats of synthetic enamel paint on new steel surfaces of any description over 10cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and directed.
M&L for one coats of synthetic enamel paint on old steel painted surfaces including preparation of surfaces of any description not otherwise descriped over 10 cm width or grith complete all as specified and directed.
M&L for providing and fixing stainless steel (Grade 304) frame for tubular structure made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature such as Dome structure architecture and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the frame with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc, of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
S&F 10 mm thick coloured polycarbonate multiwell sheet manufactured from high quality, UV stabilzed resins in roof covering incl necessary fittings & fixtures like aluminium strips coach screw and washers etc with silicon joints filler for fixing complete of any colour all as specified and directed by engineer in charge complete all as specified and directed.
M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc, of required size, on the top of floor or the side of waist slab with suitable arrangement.
Demolition of brick work or stone builder masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M & L Brickwork with subclass 'B' Brick straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 all as specified and directed.
S&F for stainless steel letters size approx 450mm height and 32mm depth made of 1mm thick stainless steel sheet with seemless welding rubbed, polished and edges made smooth with necessary fixing devices complete all as specified and directed.
Taking up or down 20 mm bore GI tubing and connections including cleaning for re-fixing complete all as specified and directed.
Supplying and laying of CPVC Pipes SDR 11 & Plain CPVC SDR 11 fittings including short lengths on wall/ceiling or laying in floors concealed in wall with all fittings (such as bends, Brass elbows, Brass Tee, short pieces, Male/female brass threaded adaptor , back nuts, diminishing pieces, caps and plugs, unions etc.) of outer diameter 20 mm complete all as specified including taking down existing GI Pipe complete all as specified and directed.
S&F 20mm bore GI tubing medium grade with all fittings and fixed to wall and ceiling or laid in floors etc complete all as specified and directed.Note :-The pipe shall be painted with bituminous paint of approved quality and the pipes should not come in contact with lime mortar or lime concrete as pipes are affected by lime etc complete all as specified and directed.
S & F in repair 20 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Demolition/taking down PVC/CI drain/Rain Water Pipe under floor or wall of internal dia 75/100 mm, set in cement mortar/ Bricket complete incl fittings.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 75mm bore complete all as specified and directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110 mm bore complete all as specified and directed.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 75 mm borecomplete all as specified and directed.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110 mm bore complete.
S&F PVC (SWR) bends with access door any radius, 75 mm bore,complete all as specified and directed.
S&F PVC (SWR) bends with access door any radius, 110 mm bore, complete all as specified and directed.
S&F PVC (SWR) junction single (single T), equal or unequal, with access door 75 mm bore, complete all as specified and directed.
S&F PVC (SWR) junction single (single T), equal or unequal, with access door 110 mm bore, complete all as specified and directed.
S&F PVC (SWR) junction single (double T), equal or unequal, with access door 110 mm bore, complete all as specified and directed.
S&F PVC (SWR) branch piece, double (double Y) equal or unequal of 110mm bore complete with access door all as specified and directed.
S&F PVC (SWR) vent cowl, 110 mm bore complete all as specified and directed.
S&F 75 mm PVC (SWR) floor trap, plain with grating with or without hole including jointing with solvent cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate mix with WPC complete all as specified and as directed.
S & F in repair CP Soap Dish Holder complete all as specified and directed. . Make :- Jaquar/Cera/Kohler
S & F in repair sheet Glass shelf assembly consisting of 5.5mmthick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed. Make :- Jaquar/Cera/Kohler
S & F in repair Corner glass sheet assembly consisting of 5.5mmthick sheet glass corner 45 cm wide both corner with chromium plated bracket guard and railing (with bracket) complete all as specified and directed. Make :- Jaquar/Cera/Kohler
S & F in repair Tubular towel rail of brass chromium plated, 20 mm dia, 'D' type, 60 cm long between flanges complete all as specified and directed. Make :- Jaquar/Cera/Kohler
S&F in repair of quarter turn bib tap with wall flange for iron pipe of size 15mm bore chromium plated all as specified and directed. Make :- Jaquar/Cera/Kohler
S & F in repair centre hole CP wash basin mixer for mixing hot & cold water screwed down for iron pipe 15 mm bore, screwed down high pressure, screwed for iron pipe and fixed complete all as specified and directed. Make :- Jaquar/Cera/Kohler
S & F in repairs wall mixers with provn for over head showers with 115 mm long bend pipe on upper side connecting legs and wall flanges complete. all as specified and directed. Make :- Jaquar/Cera/Kohler
S&F in repair CP towel rack with 3 nos hooks, 600mm long superior quality fancy type complete all as specified and directed. Make :- Jaquar/Cera/Kohler
S&F in repair 15 mm bore fancy type brass chromium plated shower rose with arm complete all as specified and directed. Make - Jaguar/Mark/Kohler complete
S&F in repair 10 litre capacity PVC low level flushing cistern with dual flush type‘ white’ with inlet, float valve including bracket with 32mm dia PVC waste/flush bend pipe appx 600 mm long complete all as specified and directed.
S & F in repair PVC connection pipe 600mm long and15 mm dia with brass fly nut/nozzle at both ends complete all as specified and directed.
S&F in repairs snow white vitreous china EWC single piece type 700X370X645 mm incl seat cover and flush fittings complete fixed in floor with brass screw complete all as specified and directed by Engr-in-Charge. Make :- Jaquar/Cera/Kohler
S&F in repair table top wash basin white, flat bottom size 525x415x140mm of Make :- Jaquar/Cera/Kohler excluding tap, chain, plug but including brackets, waste fitting 32mm dia brass chromium plated push type coupling with long screwed shanks and fly nuts flange, CP Bottle Trap plug type with wall flange Make :- Jaquar/Cera/Kohler end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F in repair Vitreous china wash down water closet pan (pedestal pattern), white including fixing bolts, flushing cistern and flush pipe connection to trap and to flushing pipe inbend cluding provn of cement concrete bedding complete all as specified and directed. Make :- Jaquar/Cera/Kohler
Supply only EWC Seat cover Black/white colour as approved of PVC closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device complete all as specified and directed. Make :- Jaquar/Cera/Kohler
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified Make :- Jaquar/Cera/Kohler
S&F in repairs vitreous China wash basin, white, flat back, padestal patern size 550x400mm including tap, chain, plug brackets, waste fitting 32mm dia ,brass chromium plated for glazed ware sink, basin,with long screwed shanks and fly nuts flange end bedded in red lead cement and other end fixed complete all as specified. Make :- Jaquar/Cera/Kohler
S&F in repair CP Stainless Seel Connection pipe 600mm long premium qualilty for Gyser, urinals, WHB etc complete all as specified and directed.
S&F in repair CP towel ring complete all as specified and directed by Engr-in-Charge Make - Kohler Cat Part No - K-5631IN-CP or equivalent in Jaquar/Cera.
S&F in repair CP Toilet Paper Holder with cover (Silver) complete all as specified and directed by Engr-in-Charge. Make - Kohler Cat Part NO 56331N-CP or equivalent in Jaquar/Cera.
S & F 32 mm dia bore Low density polyethylene pipes (LDPE)of pressure rating 6kgf/cm2 fixed complete to walls,ceilings or in floors etc for WHB and sink complete all as specified and directed .
S&F in repair Chromium plated brass angle valve including CP flanges for 15mm bore pipe, complete all as specified and directed. Make : Jaquar CON 059KN or equivalent in Kohler / Cera.
S&F in repair, two way angle valve cock chromium plated brass fancy type including cp flanges bore 15mm complete all as specified and directed.or equivalent in Jaquar/Cera/Kohler.
Dismantaling of existing boarding including fitting fixture etc complete all as specified and directed .
M&L for 18 mm thick PVC sheet of density 600 kg/cbm for kitchen cabinet and cubboard consisting of carcass one side decorative lamination and other side balancing white fixed with approved adhesive and self tapping screws for kitchen cup board or wardrobe all as specified and directed
M&L for 6 mm thick PVC sheet of density 600 kg/cbm for kitchen cabinet and cubboard consisting of carcass one side decorative lamination and other side balancing white fixed with approved adhesive and self tapping screws for kitchen cup board or wardrobe all as specified and directed
S&F for 20 mm wide & 1mm thick PVC EDGE BENDING pasted to edges of PVC furniture with suitable adhesive for kitchen cup board or wardrobe complete all as specified and directed
S&F stainless steel handle 100 mm fancy type for cub board shutter complete all as specified and directed
S&F Continuous (Piano) hinges, brass, 30 mm width of flaps (when open), bright finish complete all as specified and directed .
S & F Soft close heavy duty slow motion hinge steel nickel plated, 4 hole mounting plate, half overlay adjustment height/ depth fixed in repair completed all as specifed and directed. Make:- (Hettich, Ebco, Prime )
S & F soft close heavy duty steel nickel plated telescopic drawer channel size 20 inch full extension load capacity 50 Kgs including fixing arrangement to drawer/ baskets etc completed all as specified and directed.Make:- (Hettich, Ebco, Prime ).
S & F mild steel magnetic catches and striking plate of 50mm size for kitchen cup board or wardrobe fixed with screw including letting in and fixed completed all as specified and directed.
M&L for Preventive treatment against the danger of carbonation in exposed faces of wall:- (i) Cleaning existing surfaces of RCC members and making surface free of loose material, oil, grease etc. by vigorous wire brushing including light grit blasting where necessary as recommended by Engr-in-charge. (ii) Further, cleaning using biocide(as recommended by manufacturer) to ensure that surface is free of algae and fungus and no trace of paint (any type) left out. Sand blasting to be done to remove trace of paint. (iii) Cleaned surface to be allowed to dry. (iv) Spray a coat of primer (as recommended by manufacturer) over dry cleaned surface as required prior to final finish. Primer shall be diluted in proposition 2:1 with mineral turpentine. After application, primer shall be allowed to dry for 03 hours or as directed. (v) Apply a coat of neat Aliphatic Acrylic anti-carbonation (ACC) over the primed surface with air / spray gun at nominal rate of 3.5 ltrs per Sqm as recommended by manufacturer. (vi) Apply a more coat of Aliphatic Acrylic anti-carbonation (ACC) after 5-6 hours as recommended by manufacturer complete all as specified and directed.
M&L for following repair Treatment :- (i) Removing plaster & finishes all around the columns, slabs & beams (on all four sidescription of column to full height , three sidescription of beam to entire span & bottom of slab to area as directed) (ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible) (iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed) (iv) Cleaning exposed concrete substrate by using water jet. (v) Removing visible rust along the length of reinforcement using hand tools as approved. (The Engr-in-charge may order sand blasting if rust is approved) (vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
M&L for providing rust proof /anti corrosive treatment to bars :- (i) cleaning of all exposed bars (new & old) alround (ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer (iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating.
M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness. Note:- Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed.
M&L for treatement of cracks found in the core concrete :- (i) Opening of crack by making a ' V' notch/groove of size 12mm x 12mm over the entire length of the crack as identified by the Engr-in-charge. (ii) cleaning ' v' notch/groove of all dust/debris/loose material (iii) Drilling hole of 16mm dia and about 40mm deep along the length of crack @ (300 mm c/c or thickness of structural member whichever is less) Note : In case length of crack is found less than 300 mm then min 2 holes shall be drilled. (iv) Inserting 12 mm dia flexible PVC one way injection nipple in the hole drilled above and fixing the nipple with the help of fast setting epoxy putty. (v) Seal the surface around the nipple and the area of crack between successive nipples polymer modified mortar to ensure that there is no leakage from any gap. (vi) Allow the polymer modified mortar to cure for 24 hours and ensure that firmly fixed in postion. (vii) Cleaning nipple one by one commencin from the top to bottom in case of column and one by one in alternate direction incase of beam/slab using blow compressed air followed by water injection. An Ensuring that there is no obstruction in free flow of grouting materials complete all as specified and directed. (viii) Injecting " resin with very low viscosity monomer by mixing resin and hardener in proportions recommended by manufacturer by using injection gun equipped with pressure gauge & valves for controlling of flow of compressed air & resin. Note:- pressure shall be in the range of 1-2 kg/Sqm and shall be done in nipples one by one as per order recommended by manufacturer. Mixing of resin and hardenere shall be mixed in small quantities so as it is consumed with in 30 minutes. Before use mixer shall be stirred thoroughly. (ix) Allow entire effected surface to cure for 24 hours. (x) cutting out projected parts of the nipple & seal the hole in the nipple with epoxy putty as recommended by manufacturer. (xi) cleaning exposed surface complete all as specified and directed.
S&F 12mm dia steel sheer connector in grid pattern in between old core and new concrete as wherever directed by Engr-in-charge and as specifed by manufactuer including drilling hole of depth of 100 mm and chemical anchoring with pure epoxy resin anchoring complete all as specified and directed. (Note:- The cost of drilling hole &chemical anchoring with epoxy resin is inclueded in this item)
M&L for Providing & Pouring Micro concreting M-40 grade :- (i) Dry concrete substrate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for demolition of the column and beam, chajja, mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed. Note : The cost of micro concrete M-40 grade & Epoxy bond coat is inclueded in this item.
M&L for Drilling & chemical anchoring of new rebars/stirrups :- (i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :- 8 mm dia bar - drilling length 80 to 100 mm Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete all as specified and directed. Note:- The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item
M&L for Drilling & chemical anchoring of new rebars/stirrups :- (i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :- 16 & 20 mm dia bar - drilling length 160 to 180 mm Note:- Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete all specified and directed. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item)
M&L for use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed. Note:- Form work shall be 100% leak proof. For purpose of payment area in touch with concrete shall be measured.
S&F for stengthening existing reinforcement by use of mild steel bars of any dia , cut to length, bent to shape required, including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L cement concrete type B1 1:2:4 (20 mm graded aggregate in lintels upto 1.5 m clear span cills,holdfasts,steps,seismic and other similar bands,plinth courses , string courses lacing courses parapets and railings upto 60 cm in height copings,kneelers apex stones, bed plates,kerb not provided for water troughs and the like including weathering slightly rounded or chamfered angles and throating.
Demolition of cement concrete (unreinforced) of any description and in any position not specifically provided for complete all as specified and as directed.
M&L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate complete all as specified and directed.
M&L sand filing under floors or in foundations including watering and consoldation complete all as specified and directed..
M&L for Machine pressed precast concrete interlocking paver block of colour Red/Yellow glossy type any shape and size, as approved by Engr-in-Charge confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade over 40 mm thick sand cushion with pigment all as specified.
M&L cement concrete type C-1, 1:3:6 (using 20mm graded aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair without using extra cement incl making joints at every 2.5m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight including necessary form work and complete all as specified.
Description of Work / Item(s)
Amount
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete
Material & labour for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and modular metal flush box, modular white cover plate with frame, blanking plate etc suitable for up to required module etc complete and making good to the disturbed surfaces to match the existing complete all as specified and directed for for One light / bell point controlled by one, one way switch 06 Amps
All as per item No 2 here-in-before but for one light point controlled by two way switches
All as per item No 2 here-in-before but one Ceiling / exhaust fan point controlled by one, one way switch 5/6 Amps
All as per item No 2 here-in-before but one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, one way 06 Amps switch
All as per above item no 2 here-in-before but with point wiring 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sqmm single core FRLS cable for one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, one way 5/6 Amps switch
All as per above item no 3 above here-in-before one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board and independent MCB complete all as specified and directed
S&F modular switch, 06 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete all as specified and directed.
All as per item no 5 above but two way switch complete all as specified and directed.
S&F modular bell push with indicator, 06 Amps, single pole, one way, 230 volts complete all as specified and directed.
S&F modular switch, with indicator, 16 Amps, single pole, one way, 230 volts complete all as specified and directed.
S&F modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified and directed.
S&F modular socket outlet 02 in 01, 03 pin, 16 Amps, 02 module with shutter complete all as specified and directed.
S&F ding dong bell, AC, 230 volts, single pole incl connection complete all as specified and directed.
S&F ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 100 watts incl connection complete all as specified and directed.
S&F ceiling rose, 6 Amps, 250 volts, AC, ISI marked with three equal size terminals complete all as specified and directed.
S&F decorative wall mounting light SS finish fixture with extruded glass difuser suitable for upto 40 watt mini glass lamp, lamp holder, including 9 Watts LED bulb having minimum efficiacy at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@ operating voltage 170V-240V for fixing in decorative wall mounting light and all accessories pre-wired including connecting up including taking down of existing u/s light fitting complete all as specified and directed.
S&F surface mounting LED integrated aluminium housing batten luminaire not less than 18 W, 4 feet fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V and all accessories pre-wired including connecting up with copper conductor wire of suitable size with connector block complete all as specified and directed.
S&F sueface mounting LED integrated aluminium housing batten luminaire not less than 8 watt 2 feet fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V and all accessories pre-wired including connecting up with copper conductor wire of suitable size with connector block complete all as specified and directed.
S&F surface mounted LED building security light fitting in high pressure die cast aluminium housing not less than 20 watt fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V including light grade GI tube mounting size 40MM bracket of suitable size & length, bend to shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete and one coat of primer and one coat of synthetic enamel paint after coating of primer on GI bracket and pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core complete all as specified and as directed.
Supply and fix of exhaust fan made of moulded PVC body having 1300 RPM speed, 230 V, 50 Hz, complete with louvers shutter, Copper winding of sweep 200mm, CMH-450 including making of holes of suitable size and taking down old exhaust fan and depositing to MES store yard making good to the disturbed surfaces to match the existing complete all as specified and as directed.
Supply and fixing of exhaust fan, steel body, AC, single phase, 230 V of size 300mm sweep with blades, frame & louver having 1400 RPM speed, 1600 CMH and including making of holes of suitable size and taking down old exhaust fan and depositing to MES store yard making good to the disturbed surfaces to match the existing complete all as specified and as directed.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 220 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block to ceiling rose complete . and taking down old/unsv fan and deposit in E/M store yard complete all as specified and directed
M&L for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 20 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring complete all as specified and directed.
All as as above item No 21 but for 02 x 4 Sqmm for phase & neutral and 01 x 4 Sqmm for continuous earth wire complete all as specified and directed.
Supply and fix electric water heater, storage type 25 ltrs capacity, BEE star rated, vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adapter for inlet and outlet water connection, copper element corrosion resistance antiscaling magnesium anode having adustable knobe for temperature control and inner tank material of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure having heating element 2 KW and minium two year warranty on product, minimum three years on heating element complete all as specified and as directed (Note : Old/ unsvGeysers to be deposited in MES store)
S&F (in replacement) industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB SP, AC, 230 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed
S&F (in replacement) sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 12 way, with 200 Amps rated copper bus bar and sheet metal enclosure double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed.
S&F (in replacement) sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 08 way, with 200 Amps rated copper bus bar and sheet metal enclosure double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed.
S&F (in replacement) sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 415 volts, 04 ways with 200 Amps rated copper bus bar and metal double door suitable for MCCB 125 amps as incomer and MCB SP as outgoing along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed. (Note :- MCCB & MCB SP will be measured seperately)
S&F MCCB 125 amps, 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line/ VTPN DB & connection complete all as specified and directed.
S&F MCB, SP, AC, 240 volts of 6 to 32 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugscomplete all as specified and directed.
S&F RCBOs FOR EARTH LEAKAGE, OVERLOAD & SHORT- CIRCUIT PROTECTION DOUBLE POLE 100mA, AC, 240 volts of 63 Amps capacity and making connections by using suitable copper lugs complete all as specified and directed.
S&F RCBOs FOR EARTH LEAKAGE, OVERLOAD & SHORT- CIRCUIT PROTECTION DOUBLE POLE 100mA, AC, 240 volts of 40 Amps capacity and making connections by using suitable copper lugs complete all as specified and directed.
Supply of Digital Single phase SMART prepaid meter 10-60AMP, 50 Hz, KWH Energy meter withLCD display for, 10-60Amp, class 1.0Accuracy with all necessary control circuit & inbuilt required CT's as per IS: 16444 (Make Racemosa make RM-1000 smart Energy meter with GSM.) with GPS communication port suitable for prepaid metering, inbuilt Cut-off system with load manager, inbuilt interface for online monitoring with AMR (Automatic Meter Reading) ¢ralized control with low voltage& high voltage protection. Display all energy parameters like KWH & KVAH, Load setting, Phase wise KW & Cumulative KW, Phase wise voltage/current/frequency Racemosa make RM-3000 smart Energy meter with GSM. (Note : Old/ unsv meter to be deposited in MES store)
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete. (Note: On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.)
CHOUDHARY CONTRACTOR AND SUPPLIERS
Atish Builders LLP
M/S Chhavi Constructions Co
Adhunik Builders
JYOTI ENTERPRISES
MINHAS CONSTRUCTIONS
V r traders
Mohit Infratech
MINHAS CONSTRUCTIONS
Adhunik Builders
V r traders
M/S Chhavi Constructions Co
M/S ANIL KUMAR
JYOTI ENTERPRISES
Atish Builders LLP
Mohit Infratech
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .