Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC | L1 | Accepted-AOC Quoted rates of lowest tender found reasonable hence accepted | |
| 2 | L2₹13.2 L+₹21,204.55 (1.64%)Rejected-AOC | L2 | Rejected-AOC Quoted rates are high hence rejected | |
| 3 | L3₹13.4 L+₹41,390.51 (3.20%)Rejected-AOC | L3 | Rejected-AOC Quoted rates are high hence rejected | |
| 4 | L4₹13.6 L+₹62,878.31 (4.86%)Rejected-AOC | L4 | Rejected-AOC Quoted rates are high hence rejected | |
| 5 | L5₹13.8 L+₹84,891.99 (6.56%)Rejected-AOC | L5 | Rejected-AOC Quoted rates are high hence rejected |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
3 Jun 2021, 6:00 pmClosed
Shri Rohan Sonkar, IDSE GE Tawang
GE TAWANG Pin- 900198 C/o 99 APO
REPAIR MAINT TO LT OH LINES,LT CABLES,LT PANELS OTHER CONNECTED WK AT MARATHA GROUND,APJD ZONG,CHUJE GG,22 RAJPUT,935 IFSU,18 KUMAON,112 ENGR REGT,IV DET,323 FD REGT,STN HQ,190 MTN BDE,725 AD PL,SIG COY,24 SIKH,277 TRANSIT CAMP,B DET UNDER GE TAWANG
2021_MES_441916_1
8420/GE/TWG OF 21-22
Open Tender
Civil Works
Item Rate
180 days
Tawang
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Tawang
₹24,000
5 Sept 2021
11 May 2021
11 Jun 2021
11 May 2021
3 Jun 2021
25 May 2021
11 May 2021 - 18 May 2021
Amount
Dismantling and taking up or down old Unserviceable service cable amd LT UG cable of any size complete all as specified and directed
Supply and Laying and connecting with appropriate lugs in replacement XLPE LT cable PVC insulated, heavy duty electric cables with Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of following cross-sectional area :-
2(a) 10 Sqmm 2 Core
2(b) 16 Sqmm 2 Core
2(c) 25 Sqmm 4 Core
2(d) 35 Sqmm 3.5 Core
2(e) 50 Sqmm 3.5 Core
2(f) 70 Sqmm 3.5 Core
2(g) 95 Sqmm 3.5 core
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foundation, etc or for shafts, wells, cess-pits, menholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out for soft and loose soil.
Returing, filling in, including spreading, levelling, waterring and wall ramming in layers not exc 25 cm. for hard/dense soil.
Removing excavated material n exc. 50m and depositing where directed at a layers not exc 25 cm. for hard/dense soil.
M & L for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers all as specified.
Supply and laying unreinforced precast concrete cable cover class LV, type 1 flat size 250 x 150 x 40 mm as specified.
M&L in replacement GI pipe light grade with all fittings complete grouted in ground all as specified for the 40 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified.
M&L in replacement GI pipe light grade with all fittings complete grouted in ground all as specified for the 50 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified.
M&L in replacement GI pipe light grade with all fittings complete grouted in ground all as specified for the 80 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified.
Supply and fixing in replacement MCCB 4 Pole, 415 V, 160 Amps with breaking capacity 35 KA complete with all accessories all as specified and directed.
Supply and fixing in replacement MCCB 4 Pole, 415 V, 100Amps with breaking capacity 35 KA complete with all accessories all as specified and directed.
Supply and fixing in replacement MCCB 4 Pole, 415 V, 63Amps with breaking capacity 35 KA complete with all accessories all as specified and directed.
Dismantling of old unserviceable steel poles of any size complete all as specified and directed.
Supply and fixing in replacement steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (8.5 metres Long)
M&L for earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to galvanised earth lead strip 32x6mm by means of volts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe, 50 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer,charcoal and testing on completion all as specified and directed..
Dismantling of old ACSR or AAC Conductor all as directed by Engr-in charge
Dismantling of insulator any type, any size all as directed by Engr-in charge
S & F for replacement of pin type insulator porcelain vitreous white/ brown or green including one galvanised mild steel spindle two GI washer and one GI nut 150mm height, 150mm dia for 11000 Volt grade complete all as specified and directed.
S & F for replacement of disc insulator porcelain vitreous 145rnm high and 225 mm dia ball & socket type with tension clamp suitable for conductor single disc assy working pressure 11000 volts complete all as specified and directed.
Supply and fix Shackle type insulator ISI marked porcelain vitreous white, 1100 volts grade , ISI marked of size75 x 90 mm, including galvanized mild steel straps 31x3 mm, washers, insulators bolts (12 mm dia), washers and nuts complete all as specified and as directed.
Supply only distilled water for lead acid batteries
Dismantling of old unserviceable, broken, unused steel tubler pole of any size and specification ( Note:- The rate inclussive of excavation if needed, cutting of pole under ground level and removal from site.
Labour for area cleaning at out door and indoor sub stns including removing herbs,shurbs and grass, removing bricks bats complete all as directed.
Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement all as directed by Engr -in-charge
M & L Air break, gange operated switch HT 11000 volts, Triple pole , mounted on insulators and steel frames with operating mechanism worked from ground level with operating rod, handle etc., for current rating upto 400 amps fixed on pole / structures complete all as specified and as directed by Engr-in charge.
M&L PCC (1:3:6) type C-2 using (40mm) graded stone aggregates as in foundation filling and mass concrete (for foundation bed concrete in stays /poles or any other directed site) .
M&L for PCC 1:2:4 type B-1 using 20 mm graded broken stone aggregate as in mass concrete in coping of existing and new PCC/steel poles etc complete all as specified and directed.
Dismantling stay assembly complete (demolition of concrete etc and excavation measured seperately complete all as specified and directed).
Stay assembly complete with accessories of size 20mm as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately)
M& L Loop type insulator, vitreous porcelain, white, brown or green, small size, with overall dimensions 65 x 90mm, clearance of hole 16mm
M & L Galvanised stay strand, 7/3.15mm, ditto
M & L for Paiting of Steel tubler pole up to 9 mtr long by using Two coats aluminium paint over one coat of red oxide primer.all as directed by Engr - in - charge
Supply and fix in repair LT Over over head line phase seperator of any size (2/3/4 way) in between distribution span of LT over head lines all as directed by Engr-in-charge
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for following sizes,Indoor/Outdoor type
42(a) 25 Sqmm 4 Core
42(b) 35 Sqmm 3.5 Core
42(c) 50 Sqmm 3.5 Core
42(d) 70 Sqmm 3.5 Core
42(e) 95 Sqmm 3.5 core
42(f) 120Sqmm 3.5 core
Supply and fix Off Load changeover switch side handle in sheet enclosure 415 V AC 50 Hz of Capacity 63 Amp 4 pole all as directed by Engr- in- charge Make : Havells ,L&T,and its equivalent
Supply and fix Off Load changeover switch side handle in sheet enclosure 415 V AC 50 Hz of Capacity 100 Amp 4 pole all as directed by Engr- in- charge Make : Havells ,L&T,and its equivalent
M & L for cable route marker with route indication on cast iron disc of 100mm dia and 10mm thick, marked / written for "LT CABLE 1100 VOLTS" embosed including indicating direction fixed / bolted to 40mmx40mmx6mm thick MS angle iron support of 0.5m long embedded upto 200mm depth in concrete block of size 200mm x 200mm x 500mm of mix PCC 1:3:6, type C-1 including painting with two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surfaces complete all as specified and directed.
Laying only old Precast concrete cable covers of Class LV type, Type 1, flat size 250mm x 150mm x 40mm
Laying only old serviceable XLPE LT cable PVC insulated, heavy duty electric cables with Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of following cross-sectional area :-
53(a) 10 Sqmm 2 Core
53(b) 16 Sqmm 2 Core
53(c) 16 Sqmm 4 Core
53(d) 25 Sqmm 4 Core
53(e) 35 Sqmm 3.5 Core
M/S L G BUILDERS
L T CONSTRUCTION
M/S NAVA BHARAT BUILDERS
M/S P N ASSOCIATES
M/S RHEGON CONSTRUCTION
SHELLUNG CONSTRUCTION
M/S TARAYANA BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .