GE(AF) E/M CHAKERI
O/o GE(AF) E/M CHAKERI
REPAIR AND MAINT OF PACKAGE TYPE AIR CONDITIONER AND WATER COOLED AIR CONDITIONER PLANT AT VARIOUS LOCATION IN TECH AREA AT AFS CHAKERI KANPUR.
2026_MES_798975_1
8879/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AOR of GE(AF) E/M CHAKERI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE(AF) E/M CHAKERI
₹1 L
Yes
19 Nov 2026
19 Nov 2026
15 Dec 2026
19 Nov 2026
8 Dec 2026
2 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for servicing of indoor unit of package type air conditioner of capacity 5.5 TR, 8.75 TR, 11 TR or 16.5 TR by opening the front grill and bottom grill, cleaning the filters by water jet spray, removing dust and dirt from the entire unit, checking the electrical connections, checking all joints and the liquid and vapour lines for leakage by applying soap solution, checking the functioning of all spares and replacing defective spares under the relevant items of this schedule, and putting the air conditioner into operation, complete all as specified and directed by Engineer-in-Charge.
Note: (i) Spare parts shall be measured and paid separately under the relevant items of this schedule.
(ii) The filters shall be slid out, washed with water, dried in the shade and reinstalled.
(iii) The compressor shall be checked for oil leakage, the anti-vibration rubber mountings shall be inspected for wear and the mounting lugs shall be tightened. | 40 | Each Job | 1.25 | ₹50 |
| 2 | All as per item No. 1 above but for outdoor unit of package type air conditioner of capacity 5.5 TR, 8.75 TR, 11 TR or 16.5 TR. | 60 | Each Job | - | - |
| 3 | Supply and fixing in replacement of blower motor for 5.5 TR package type air conditioner, of voltage, rating and frame size matching the existing motor, including testing and commissioning, complete all as specified and directed by Engineer-in-Charge. | 7 | Each | 100 | ₹700 |
| 4 | Supply and fixing in replacement of blower assembly for 5.5 TR package type air conditioner, matching the existing assembly, complete all as specified and directed by Engineer-in-Charge. | 6 | Each | 53 | ₹318 |
| 5 | Supply and fixing in replacement of condenser fan motor, single phase, 230 V, 50 Hz AC, of rating 1/3 HP to 1/2 HP matching the existing motor, for outdoor unit of 5.5 TR package type air conditioner, complete all as specified and directed by Engineer-in-Charge. | 25 | Each | 10 | ₹250 |
| 6 | Supply and fixing in replacement of filter drier with flare nuts, of size matching the existing liquid line, for package type air conditioner, complete all as specified and directed by Engineer-in-Charge. | 60 | Each | - | - |
| 7 | Supply and fixing in replacement of thermostatic expansion valve of 5.5 TR capacity, suitable for refrigerant R-22, for 11 TR package type air conditioner, complete all as specified and directed by Engineer-in-Charge. | 20 | Each | 100 | ₹2,000 |
| 8 | Supply and fixing in replacement of thermostatic expansion valve of 5.5 TR capacity, suitable for refrigerant R-407C, for 16.5 TR package type air conditioner, complete all as specified and directed by Engineer-in-Charge. | 15 | Each | 53 | ₹795 |
| 9 | Supply and fixing in replacement of liquid line valve for 5.5 TR circuit, of size 1/2 inch, matching the existing sample, including leak testing of the system before and after fixing of the new valve, complete all as specified and directed by Engineer-in-Charge. | 30 | Each | - | - |
| 10 | Supply and fixing in replacement of liquid line valve for 5.5 TR circuit, of size 5/8 inch, matching the existing sample, including leak testing of the system before and after fixing of the new valve, complete all as specified and directed by Engineer-in-Charge. | 40 | Each | 100 | ₹4,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.35 MB
Workdetails.pdf
Additional Documents • 0.09 MB
Tender_Acceptance_Letter.pdf
Additional Documents • 0.08 MB
BOQ_896363.xls
BOQ • 0.84 MB
Schedule_of_Credit_8879.pdf
Additional Documents • 0.27 MB
Tender_Document_8879.pdf
Tender Documents • 0.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .