Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC | L1 | Accepted-AOC AOC is awarded to L1 bidder i.e. M/s Trade Palace | |
| 2 | L2₹5.5 L+₹1.2 L (28.7%)Rejected-AOC | L2 | Rejected-AOC AOC is awarded to L1 bidder i.e. M/s Trade Palace | |
| 3 | L3₹6.5 L+₹2.3 L (53.9%)Rejected-AOC | L3 | Rejected-AOC AOC is awarded to L1 bidder i.e. M/s Trade Palace | |
| 4 | L4₹6.7 L+₹2.4 L (57.4%)Rejected-AOC | L4 | Rejected-AOC AOC is awarded to L1 bidder i.e. M/s Trade Palace | |
| 5 | Rejected-Technical | - | Rejected-Technical Didnot submit the Notarized copy of Annexure -IX |
Tender Value
₹8.2 L
EMD Value
₹16,452
Closing Date
3 Oct 2023, 2:00 pmClosed
HoS Maintenance
IPM Section, IIT Guwahati
Miscellaneous Electrical Works at Dhansiri Hostel in IITG Campus
2023_IITG_773746_1
IITG/IPM/NIT/R/2023-24/27
Open Tender
Electrical Works
Works
45 days
IIT Guwahati
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹16,452
Yes
8 Feb 2024
27 Sept 2023
4 Oct 2023
27 Sept 2023
3 Oct 2023
27 Sept 2023
Amount
Supply of 150watt LED flood light. (Make-Bajaj/Syska/Philips/Havells)
Supply of 45watt LED Steet Light. (Make-Bajaj/Syska/Philips/Havells)
Supply and installation of hot dip gavanized single arm bracket having 100mm long with 48.3mm OD pipe for installation of roadway lighting luminaries as required.
Supply of 15ltrs Geyser mounting as required. (Make-Racold/Bajaj/Venus/CG).
Supply of 50ltrs Geyser mounting as required. (Make-Racold/Bajaj/Venus/CG)
Installation of new geyser after dismantling of damaged geyser in desired locations etc. complete as required.
Supply of 20watt LED batten Light alongwith all accessories. (Make- Syska/ Philips/ bajaj/ havells/ CG)
Supply of 3core, 2.5 Sq.mm Cu Unarmoured Cable. (Make-Havells/ RR Kabel/ KEI/ Polycab/ Finolex)
Supply and installation of SMC junction box with 6Amp MCB, channel, etc as required. (Make-Sintex/Hensel or equivalent)
Supply of 18watt, surface mounted rimless square 1ft X 1ft down light moulded in engineering plastic. Input Voltage AC 90-300V, 50Hz/60Hz, Efficacy 100lm/w. (MAKE - Bajaj, Model No-BPSLR Surface 24W LED WH SQ SD or equivalent)
Supply and installation of 10mtr long SP 44MS tubular pole. (Make-Nezone or equivalent)
Supply of following types and sizes of 1.1kv grade PVC insulated aluminium conductor armoured underground cable. (Make-RR Kabel/KEI/Finolex/Polycab/Havells)
a) 4 X 6 Sq.mm
Supply of 90watt LED Steet Light. (Make-Bajaj/Syska/Philips/Havells)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed Conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
a) 5/6 amps switch
Installation, testing and commissioning of pre-wired,fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including onnections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
a) 6 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a) Single pole
b) Double pole
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
a) Upto 35 sq. mm (clamped with 1mm thick saddle)
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
20 amps. SPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed Steel/ PVC conduit as required
a) 2 run of cable
Erection of steel tubular or rail pole strut in cement concrete1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
M/S ANUSHREE CONSTRUCTIONS & ASSOCIATES
Mudoi Enterprise
jayaa enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .