Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.7 L+₹37,570 (1.55%)Rejected-Finance | L2 | Rejected-Finance Being L2 |
Tender Value
₹24.3 L
EMD Value
₹48,640
Closing Date
10 Jul 2023, 2:00 pmClosed
Executive Engineer University Works Department
Office of the Executive Engineer University Works Department University of Jammu
Creation of Electrical Sub-Station for providing the LT power supply to different buildings at Reasi Campus of Jammu University Reasi
2023_UDJK_219166_2
Fresh eNIT 835 dated 23-6-2023 (3rd Call)
Open Tender
Electrical Works
Item Rate
90 days
University of Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
Executive Engineer University Works Department
₹48,640
27 Jan 2025
28 Jun 2023
12 Jul 2023
28 Jun 2023
10 Jul 2023
28 Jun 2023
Amount
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel,making connections, etc. as reqd. (Make Legrand/I.A/L&T/HPL/Havells) 400 AMP 35 KA TPMCCB
Supply and making straight through cable joint with heat shrinkable jointing kit complete with all accessories including Ferrules suitable for following size of XLPE Al. conductor cable of 11 KV grade as required. (Make ISI polymer) 3.5 core 185 sqmm
Earthing with G.I earth plate(600x600x3) mm copper earth including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required.
Supply laying 4mm dia copper wire earth wire on surface/recess for loop earthing.
Supply & laying 25X5MM copper strip on surface/recess for connection.
Erection of steel tubular pole or rail pole strut in cement concrete 1:3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc. as required.
Supply and Erection of 11 KV pin type insulator complete with large steel head G.I pin, nuts, washers etc. as required.
Erection of ACSR Conductor of following size including binding etc. as required. 7/2.11 MM TO 7/3.00 MM
-------------------do---------------------- 7/3.35 MM TO 7/4.00 MM AND ABOVE
Supply and erection of Stay Set complete with 19/20 mm dia x 1.8 meter long stay rod, Anchor plate of 45 cm x 45 cm x 7.5 mm, thimble stay clamps, bow tightener, 7/3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 foundation including excavation and refillIng etc as required.
Laying of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. ABOVE 95 SQMM & UPTO 185 SQMM
Supply and errection of 30 Amp Aerial fuse complete as required.
Providing & fixing M.V danger notice plate of (200x150)mm made of Mild Steel at least 2mm thick and vitreous enameled white on both side and with inscription in single red colour on front side as required
Supply and erection of galvanized ‘D’ iron clamps complete with shackle insulator (100 mm x 110 mm), G.I bolts, nuts and washers, coach screws etc. as required.
Providing & erection of channel iron (75mm x 40mm x 6) 7.14 kg per metre, cross arm for 4 wire overhead line conductor complete with clamps, bolts, nuts including drilling holes for pin insulators etc. painting with primer and finish paint.
Supply of swaged type steel tubular pole of following height duly painted with two coats of red oxide and two coats of silver paint made of Mild Steel conforming to IS 2713 part III of 1980 designated as 410 SP15 panted in 1/6th the height of the pole deep welded with (300x300x6) mm base plate. The pole shall be provided with suitable clamps for fixing the cross arms/ M.S. channels. The planting depth of the pole shall be 1.5 mtr & height above Ground level shall be 7.50 mtr. The length of the bottom, middle and top sections shall be 5 mtr, 2 mtr & 2 mtr. The outer dia and thickness of the sections shall be (139.7x4.50) mm, (114.3x3.65) mm & (88.9x3.25) mm respectively including Providing and making steel pole collar with cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 stone aggregate 20mm) of specified size and shape including formwork, plastering if required, curing etc. as required. (Volume of pole/pipe not to be deducted). AS PER SITE 8 mtr height
Supply installation testing and commissioning of following rating , 11/0.433 KV, three phase, 50 HZ, outdoor type, Dynll, ONAN, copper wound distribution transformer with off load tap changing arrangement on HV side in steps of ± 2.5%, ± 5%, ± 7.5% complete with all accessories viz. Buchholz relay for Alarm & Trip, Marshalling Box for alarm and trip, Conservator, oil & winding temperature indicators, magnetic oil level indicator, lifting lugs, earthing studs, name plate and winding connections diagram and Bi-directional rollers etc. The transformer to be designed for an ambient temperature of 45C and winding temperature rise of 50C over ambient. Transformer to be as per IS 2026 Part I to Part V power transformer including first filling of filtered dehydrated transformer oil and conforming to IS 2026 (Part II & 5) of 1977 (Make Bharti/ Electric field/ crompton) 200 KVA
Providing fixing testing and commissioning of heavy duty 11KV link set.
Providing fixing testing and commissioning of heavy duty 11 KV station type lightening arrestor set of three piece non linear resistor, suitable for 3 wire, 11KV overhead lines with rated voltage 9KV (rms) with normal discharge current rating of 5KA complete with G.I clamping arrangement G.I bolts, nuts washers etc as required. (Make Jayshree/ Crompton/Oblum NP)
Supply installation testing and commissioning of post type/ Horn gap type 11KV Triple Pole drop fuse unit fitted with fuse element. (D.O. Set)
Supply of ACSR weasel conductor of required aluminum and steel strands including binding etc. as required as per IS O 398 part 2 (6/2.59MM + ½.59MM)
Supply of ACSR Rabbit conductor including bending etc as required as per IS 398 part 2 of (6/3.35MM + 1/3.35MM)
Supply of following size of single core XLPE insulated power cable of 1.1 KV grade including end termination excavation, sand cushioning, protective covering and refilling the trench etc as required. (Make Havells/CCI/Ecko) 185 Sqmm Single core
-----------------do------------- 185 Sqmm 3.5 core
Providing fixing hexagonal/ring type/cradle type guard netting under H.T line with suitable size angle iron where Reqd. of (40x40x5)mm size
Providing & laying PCC platform 1:4:8 (1 cement :4 coarse sand : 8 graded stone aggregate 20mm nominal size) with 20% boulder for construction of platform of size (5x8x4 ft.) for Electric sub-station and 1ft below ground including cost of earth work , shuttering and curing etc. complete.
Providing & fixing brass lock type clamps/thimbles of required size for L.T/H.T transformer bushings
Supply& installation of flat iron braced (50x6) mm as per the site requirement.
Supply& fixing of 20mm dia G.I pipe for street light bracket including bending to shape, (40x3) mm flat iron clamp and wiring with 1.5 sqmm PVC insulated wire complete as required.
Providing & fixing welded mesh around the transformer alongwith the angle iron of (40x40x5)mm size approximately 2’-0” height (04 Nos.) above the transformer fixed at corners of the platform including priming and painting etc. complete.
S D SALES AND ENGENRING CONCEPTS
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .