| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹25.0 L+₹11,333 (0.46%)Rejected-Finance PEMASAR ROAD WARD NO 04 UDASAR BIKANER RAJ 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-Finance High Rate Quoted | |
| 3 | L3₹25.2 L+₹25,813 (1.04%)Rejected-Finance | L3 | Rejected-Finance High Rate Quoted |
Tender Value
₹22.1 L
EMD Value
₹44,220
Closing Date
5 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Shery Goel, CWE Bikaner
HQ CWE Bikaner, Bikaner Mil Stn
Rehabilition of demaged structure of Bldg No. P-163 of main wksp for A Veh with store sec at Bikaner Mil Stn
2024_MES_636554_2
CA No CWE BKN-Token No. 71/2023-2024
Open Tender
Civil Works
Item Rate
180 days
GE N BIKANER
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (N) Bikaner
₹44,220
Yes
27 Mar 2024
13 Feb 2024
12 Mar 2024
13 Feb 2024
5 Mar 2024
20 Feb 2024
13 Feb 2024 - 17 Feb 2024
Amount
Note : The qouted rates should be irespective of hieght upto 12m contractor shall not made claim for the same.
Demolition of reinforced cement concrete of any description and in any position (reinforcement cut as required to facilitate demolition) not otherwise specifically provided for in this Schedule, complete all as specified & as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Taking down cement plaster or cement lime plaster, terrazo etc on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, as in roof coverings etc including ridges complete all as specified and directed.
Dismantling of cast iron, wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed.
Taking down and refixing of same opening of chowkat or frame or window/ventilator with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
Taking down old iron gate of size exceeding 6 sqm and refixing the same including fixing of necessary hold fast in PCC 1:2:4, type B1 (using 20mm graded stone aggregate) complete all as specified & as directed.
M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded crushed stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal for rough finished flat surfaces of concrete complete all as specified & as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified & as directed.
Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified & as directed.
Formwork to edges of concrete flats, roofs, floors etc and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for rough finished surfaces of concrete complete all as specified & as directed.
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framed signed boards, walk ways, railings, framework of water tanks and similar work including welding conforming to Grade E-165 (Fe 290), complete all as specified & as directed.
S&F mild steel butt hinges, holdfast, hook and pintle hinges, large hasp and staples, clamps, hooks for hanging fans and similar small articles conforming to Grade E-165 (Fe 290) including necessary welding etc. and fixed in position complete all as specified & as directed.
S&F framed work brackets of angles or tee with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. not exc 10 kg each brackets, conforming to Fe.290 Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified & as directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm and not exc 10cm long and dia of neck 11 to 15 mm complete all as specified & as directed.
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
M&L for mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 complete all as specified & as directed.
S&F Pre-painted galvalume aluminium zinc coating corrugated steel sheet 0.50mm thick with coating AZ-150 gsm of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & as directed. Note : Colour of sheet shall be as approved by the GE.
Re-Fixing only Pre-painted galvalume aluminium zinc coating corrugated steel sheet 0.50mm thick with coating AZ-150 gsm of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, obtained serviceable sheet vide serial item No. 5.00 here-in-before with self tapping screws complete all as specified & as directed. Note : Colour of sheet shall be as approved by the GE.
S&F Pre-painted galvalume aluminum zinc coating Plain steel sheet 0.50mm thick with coating AZ-150 gsm of any colour having tensile strength of 550 Mpa as in roof covering/ridge/fascia/cladding to wall, fixed with self tapping screws complete all as specified & as directed. Note : Colour of sheet shall be as approved by the GE.
Re-Fixing Pre-painted galvalume aluminum zinc coating Plain steel sheet 0.50mm thick with coating AZ-150 gsm of any colour having tensile strength of 550 Mpa as in roof covering/ridge/fascia/cladding to wall, obtained serviceable sheet vide serial item No. 5.00 here-in-before with self tapping screws complete all as specified & as directed. Note : Colour of sheet shall be as approved by the GE.
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.
M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified.
M&L for preparation of newly plastered / unplastered surfaces of walls & applying three coats of white wash complete all as specified.
M&L for preparation of newly plastered / unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint complete all as specified & as directed.
Hacking out old broken glass any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips complete all as specified and as directed.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, complete all as specified & as directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls including dismantling & taking out or down old unserviceable 110mm bore PVC pipe complete all as specified and directed.
S&F hard drawn steel wire fabric, weight not exc 4 Kg per sqm, cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia, supplied and fixed in reinforcement, complete all as specified & as directed.
M&L for scaffolding upto height 15m with iron props assembly fixed complete to support the existing structural components, concrete and brick work element of trusses to hold in position till the time, it is not required complete all as specified & as directed.
M&L for epoxy bonding agent for old concrete for bonding old with new concrete complete all as specified & as directed. (Dr Fixit 211 EBA/Sikka/Forsoc).
M&L for running welding in repairs with thickness/ dia of metal exc 20mm but not exc 25mm including provision for stopper of peg stay steel handle fitting complete all as specified & as directed.
Structural design for Roof Slab, Beams, Chajja and other connected RCC members required to be re-constructed under this Schedule with & including vetting of structural design from approved Govt Engineering College/NITTTR/CBRI, complete all as specified and as directed. Notes : (i) Tenderer shall carryout the site visit to ascertain the size of slab, other RCC members, arrangement of rooms, etc required for design purpose. (ii) Four sets of Structural drawings shall be provided to GE by the contractor duly vetted as above.
Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/ batten/ casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators, wooden boxes, MS sunken boxes, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for Modular point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular switches, sockets, regulators etc with and including modular cover plates with frame of requisite module, complete all as specified and as directed. Notes : (i) Cost of cutting/leaving forming chases for conduits, sinking for modular metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed to include for modular metal flush boxes of requisite module and modular cover plates with frame of requisite module of colour as approved by GE.
All as per serial item No. 43.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches complete all as specified and directed.
All as per serial item No. 43.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete all as specified and directed.
All as per serial item No. 43.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed.
All as per serial item No. 43.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed.
S&F Modular switch 1 way 6A, 1 module, complete all as specified and as directed.
S&F Modular switch, 1 way 16 Amp, 1 module, complete all as specified and as directed.
S&F Modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and as directed.
S&F Modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and as directed.
S&F ceiling rose, PVC/Polycarbonate insulated body, 65mmx50mm with three terminals, ISI marked, complete all as specified and as directed.
S&F electronic fan regulator, flush type, stepped type with 5 step control, 230 Volts, 120 Watt, 2 module, including making hole in sheet top cover and connecting up, ISI marked, complete all as specified and as directed.
S&F LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed. Make : Philips, Cat Part No. BN021 LED 20S PSU CW GR S2/ Crompton Greaves, Cat Part No. LDDR20-CDL Dazzle Ray/ Bajaj, Cat Part No. BCLAB 20W or equivalent make here-in-after in appendix 'B'
Supply and fixing LED industrial high bay light 200 watt, 230 Volts, AC indoor type with thermal management in multiple optics and equipped with IP 66 protection with impact and corrosion resistant including lumen efficiency of LED fittings shall not be less than 150 lumen/watt complete all as specified and as directed. Make : Crompton Greaves, Cat Part No. CIP325-200-57-60D-SL-GL-NSG or equivalent make here-in-after in appendix 'B'
NOTES FOR LED LIGHT FITTINGS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
S&F sheet metal enclosure for distribution boards flushed in wall, double door type, suitable for fixing MCBs/MCCBs, 415 Volts with 200 Amps rated bus bar, load line DB fitted with bus bar neutral links blank plates, TPN, vertical load line, 4 way, suitable for MCB, fitted complete all as specified and as directed including taking down old existing unserviceable DB with fixtures of any type & capacity :- Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F sheet metal enclosure, double door type, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 8 way, 240 Volts, fixed in repairs, complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, SPN, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCCB 4 Pole 100 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades & refixing ceiling fan of any make, any sweep, keeping side to store in safe custody for painting of ceiling fans complete, insitu with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and directed.
Supply, assembling, hanging, fixing & testing Ceiling Fan of size 1200 mm sweep, minimum air delivery 210 CMM with service value 6.00 BEE, 5 star rated, with brushless direct current (BLDC) motor, single phase, AC supply, 230 Volt, with & including down rod, canopies, three number blades, capacitor 2.5 mfd, hook, rubber reel, safety pins, nuts, bolts, washers, cable connector and making connection with PVC insulated & sheathed 1 Sqmm three core flexible copper multistranded conductor cable (ISI marked) from ceiling rose to connector of ceiling fan including marking of SM / MES number with thick synthetic enamel paint of approved tint complete all as specified and as directed. Note :- The font, style & place of writing SM/ MES number with synthetic enamel paint on ceiling fan shall be as directed by the Engineer-in-Charge and cost thereof shall deemed to be included in quoted rates.
Taking down Air circulator fan 750mm sweep, 230 Volts, Single Phase, wall mounting, sealing cable end, dismantling blades and removing fan and blades keeping side in store in safe custody and refixing after repairing such as motor winding, replacement of ball bearing and other required parts and painting of Air circulator fan, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust and reassembling the fan complete including writing MES No at the site complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with Four runs of 10 sqmm (nominal area) size main cable & Two run of 10 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 32mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 04 runs of 10 sqmm size main cable, 02 run of 10 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
SUBHAM ENTERPRISES
RAJENDER ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .