Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC NO 5 3 JJ KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | TAMIL NADU | 600014 | ₹20.5 L Quoted ₹21.1 L | L1 | Accepted-AOC Being the lowest |
| 2 | L2₹28.3 LRejected-Finance | ₹28.3 L | L2 | Rejected-Finance HIGHER THAN L1 BIDDER |
| 3 | L3₹29.8 LRejected-Finance N NO 6 OLD NO 10 1ST STREET KASTHURI BAI NAGAR AVADI CHENNAI 600054 | CHENNAI | CHENNAI | TAMIL NADU | 600054 | ₹29.8 L | L3 | Rejected-Finance HIGHER THAN L1 BIDDER |
| Sl No | Description | Qty | Unit | G.JANAKIRAMAN CO L1 | MONISH CONSTRUCTIONS L2 | Sri Lakshmi and Company L3 |
|---|---|---|---|---|---|---|
| 1.00 | Comprehensive maintenance of sewage system consisting of sewage line, manholes of various sizes and depth.cleaning and removal of blockages of floortrap, Nahani/ trap and gully trap etc., water closet of various sizes in buildings including removal of blockage/ clogging in sewage lines of entire sewage system of (CGRA Meenambakkam (Thalkancherry)) area by cleaning of sewage drains of dia exc 100mm and not exc 300mm dia including blocked manholes by rodding from manholes and well flushing after cleaning and removal of blocked/ decomposed sludge/ dirt and other materials to a place exc 50m and n.exc. 500m and burning the same including removing and refixing manhole covers without damaging complete as and when required basis complete all as specified and as directed by Engineer-in-charge
Notes:- (i)The unit rate quoted by the tenderer shall be inclusive of employing sufficient number of person/ T&P for attending day to day maintenance of sewage lines and other items mentioned accordingly the unit rate shall be arrived at. No extra cost what so ever shall be admissible on this account. However it is expected to employ minimum one safaiwala and one helper on daily basis for the above item (for CGRA Meenambakkam (Thalkancherry) area) irrespective of complaints. For every group of areas a register shall be maintained to show the date and time of complaints and date and time of rectification duly signed by a rep of users of the unit concerned and countersigned by JE/AGE. Failure to rectify and blokage/ complaints in 05 hours from the time of intimation, a penalty of Rs 600/- per complaint shall be imposed and effected from the payment due to the contractor.
(ii) The rate quoted by the contractor shall be deemed to include for Maintenance of entire sewage system in functional condition at CGRA Meenambakkam (Thalkancherry) | 9 | Per Month | 28,000 ₹2.5 L | 32,000 ₹2.9 L | 32,000 ₹2.9 L |
| 2.00 | Comprehensive maintenance of sewage system consisting of sewage line, manholes of various sizes and depth. cleaning and removal of blockages of floortrap, Nahani/ trap and gully trap etc., water closet of various sizes in buildings including removal of blockage/ clogging in sewage lines of entire sewage system of (ICGAS Chennai) area by cleaning of sewage drains of dia exc 100mm and not exc 300mm dia including blocked manholes by rodding from manholes and well flushing after cleaning and removal of blocked/ decomposed sludge/ dirt and other materials to a place exc 50m and n.exc. 500m and burning the same including removing and refixing manhole covers without damaging complete as and when required basis complete all as specified and as directed by Engineer-in-charge
Notes:- (i)The unit rate quoted by the tenderer shall be inclusive of employing sufficient number of person/ T&P for attending day to day maintenance of sewage lines and other items mentioned accordingly the unit rate shall be arrived at. No extra cost what so ever shall be admissible on this account. However it is expected to employ minimum one safaiwala and one helper on daily basis for the above item (for ICGAS Chennai) irrespective of complaints. For every group of areas a register shall be maintained to show the date and time of complaints and date and time of rectification duly signed by a rep of users of the unit concerned and countersigned by JE/AGE. Failure to rectify and blokage/ complaints in 05 hours from the time of intimation, a penalty of Rs. 600/- per complaint shall be imposed and effected from the payment due to the contractor.
(ii) The rate quoted by the contractor shall be deemed to include for Maintenance of entire sewage system in functional condition at ICGAS Chennai | 9 | Per Month | 28,000 ₹2.5 L | 32,000 ₹2.9 L | 32,000 ₹2.9 L |
| 3.00 | M&L for Cleaning of septic tank including removal of sludge/waste water outside MD land and washing with water etc including applying disinfectant etc of various capacity of tanks complete all as specified and directed. | 1,600 | Cum | 410 ₹6.6 L | 550 ₹8.8 L | 545 ₹8.7 L |
| 4.00 | M&L for Demolition and breaking up drain pipes set in cement mortar (salt glazed stoneware/asbestos cement/reinforced) including bed concrete and removal of debris to low lying area to a distance not exceeding 100m, of the 150mm bore complete all as specified and directed by Engr-in-Charge. | 300 | Rm | 120 ₹36,000 | 650 ₹1.9 L | 362 ₹1.1 L |
| 5.00 | M & L for salf glazed stoneware drain pipes of Grade 'A', of the 150mm bore laid in trenches and jointed in CM complete all as specified and directed by Engr-in-Charge. | 150 | Rm | 550 ₹82,500 | 720 ₹1.1 L | 650 ₹97,500 |
| 6.00 | M & L for cement concrete bed type C2 (1:3:6, using 40mm graded stone aggregate) to drain pipes including packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete of the following 150mm bore complete all as specified and directed by Engr-in-Charge. | 150 | Rm | 150 ₹22,500 | 230 ₹34,500 | 250 ₹37,500 |
| 7.00 | M & L for salf glazed stoneware drain pipes of Grade 'A', of the 180mm bore laid in trenches and jointed in CM complete all as specified and directed by Engr-in-Charge. | 150 | Rm | 450 ₹67,500 | 620 ₹93,000 | 685 ₹1.0 L |
| 8.00 | M & L for cement concrete bed type C2 (1:3:6, using 40mm graded stone aggregate) to drain pipes including packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete of the following 180mm bore complete all as specified and directed by Engr-in-Charge. | 150 | Sqm | 380 ₹57,000 | 230 ₹34,500 | 450 ₹67,500 |
| 9.00 | Cutting Salt glazed stone ware drain pipe 150mm bore in position including jointing socket end of new pipe to same with packed spun yarn and cement mortar (1:1) complete all as specified and as directed. | 20 | Each | 150 ₹3,000 | 550 ₹11,000 | 350 ₹7,000 |
| 10.00 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for 150mm bore pipe, all as specified and as directed. | 15 | Each | 200 ₹3,000 | 700 ₹10,500 | 450 ₹6,750 |
Updated dates
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
29 Nov 2025, 6:00 pmClosed
Garrison Engineer (I) (CG) Chennai
Garrison Engineer (I) (CG), P-16, CGRA Meenambakkam 4th Street NGO Colony, Nanganallur, Chennai 600 061
REPAIR/ RENEWAL AND CLEANING OF BLOCKAGES IN SEWAGE LINES, SOIL WASTE AND SANITARY PIPES MANHOLES, SEPTIC TANKS IN HIGH RISE AND OTHER BUILDINGS AT CGRA MEENAMBAKKAM AND ICGAS UNDER GE (I) (CG) CHENNAI
2025_MES_738032_1
8254/E8
Open Tender
Civil Works
270 days
CHENNAI
As per tender documents
7 documents required · 7 mandatory
₹500
₹50,000
Yes
25 Mar 2026
1 Nov 2025
1 Dec 2025
1 Nov 2025
29 Nov 2025
16 Nov 2025
1 Nov 2025 - 7 Nov 2025
Amount
Comprehensive maintenance of sewage system consisting of sewage line, manholes of various sizes and depth.cleaning and removal of blockages of floortrap, Nahani/ trap and gully trap etc., water closet of various sizes in buildings including removal of blockage/ clogging in sewage lines of entire sewage system of (CGRA Meenambakkam (Thalkancherry)) area by cleaning of sewage drains of dia exc 100mm and not exc 300mm dia including blocked manholes by rodding from manholes and well flushing after cleaning and removal of blocked/ decomposed sludge/ dirt and other materials to a place exc 50m and n.exc. 500m and burning the same including removing and refixing manhole covers without damaging complete as and when required basis complete all as specified and as directed by Engineer-in-charge Notes:- (i)The unit rate quoted by the tenderer shall be inclusive of employing sufficient number of person/ T&P for attending day to day maintenance of sewage lines and other items mentioned accordingly the unit rate shall be arrived at. No extra cost what so ever shall be admissible on this account. However it is expected to employ minimum one safaiwala and one helper on daily basis for the above item (for CGRA Meenambakkam (Thalkancherry) area) irrespective of complaints. For every group of areas a register shall be maintained to show the date and time of complaints and date and time of rectification duly signed by a rep of users of the unit concerned and countersigned by JE/AGE. Failure to rectify and blokage/ complaints in 05 hours from the time of intimation, a penalty of Rs 600/- per complaint shall be imposed and effected from the payment due to the contractor. (ii) The rate quoted by the contractor shall be deemed to include for Maintenance of entire sewage system in functional condition at CGRA Meenambakkam (Thalkancherry)
Comprehensive maintenance of sewage system consisting of sewage line, manholes of various sizes and depth. cleaning and removal of blockages of floortrap, Nahani/ trap and gully trap etc., water closet of various sizes in buildings including removal of blockage/ clogging in sewage lines of entire sewage system of (ICGAS Chennai) area by cleaning of sewage drains of dia exc 100mm and not exc 300mm dia including blocked manholes by rodding from manholes and well flushing after cleaning and removal of blocked/ decomposed sludge/ dirt and other materials to a place exc 50m and n.exc. 500m and burning the same including removing and refixing manhole covers without damaging complete as and when required basis complete all as specified and as directed by Engineer-in-charge Notes:- (i)The unit rate quoted by the tenderer shall be inclusive of employing sufficient number of person/ T&P for attending day to day maintenance of sewage lines and other items mentioned accordingly the unit rate shall be arrived at. No extra cost what so ever shall be admissible on this account. However it is expected to employ minimum one safaiwala and one helper on daily basis for the above item (for ICGAS Chennai) irrespective of complaints. For every group of areas a register shall be maintained to show the date and time of complaints and date and time of rectification duly signed by a rep of users of the unit concerned and countersigned by JE/AGE. Failure to rectify and blokage/ complaints in 05 hours from the time of intimation, a penalty of Rs. 600/- per complaint shall be imposed and effected from the payment due to the contractor. (ii) The rate quoted by the contractor shall be deemed to include for Maintenance of entire sewage system in functional condition at ICGAS Chennai
M&L for Cleaning of septic tank including removal of sludge/waste water outside MD land and washing with water etc including applying disinfectant etc of various capacity of tanks complete all as specified and directed.
M&L for Demolition and breaking up drain pipes set in cement mortar (salt glazed stoneware/asbestos cement/reinforced) including bed concrete and removal of debris to low lying area to a distance not exceeding 100m, of the 150mm bore complete all as specified and directed by Engr-in-Charge.
M & L for salf glazed stoneware drain pipes of Grade 'A', of the 150mm bore laid in trenches and jointed in CM complete all as specified and directed by Engr-in-Charge.
M & L for cement concrete bed type C2 (1:3:6, using 40mm graded stone aggregate) to drain pipes including packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete of the following 150mm bore complete all as specified and directed by Engr-in-Charge.
M & L for salf glazed stoneware drain pipes of Grade 'A', of the 180mm bore laid in trenches and jointed in CM complete all as specified and directed by Engr-in-Charge.
M & L for cement concrete bed type C2 (1:3:6, using 40mm graded stone aggregate) to drain pipes including packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete of the following 180mm bore complete all as specified and directed by Engr-in-Charge.
Cutting Salt glazed stone ware drain pipe 150mm bore in position including jointing socket end of new pipe to same with packed spun yarn and cement mortar (1:1) complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for 150mm bore pipe, all as specified and as directed.
Removing plants /herbs grown on duct /wall portion, SWR pipes joint area for multistoried buildings at any storeyed. Cleaning with steel brush and rubbish down all dirt, mud and shabby materials from the SWR pipe joints & duct / wall portion complete and applied neat cement slurry/cement mortar on the leakages of SWR pipe joints /vertical stacks and applying one coats of cement based paints on duct wall portion all as specified and as directed by Engr-in-charge.
Removing plants / herbs grown on walls/junctions with roots using herbicide chemical and of existing brick and concerte in high raised building at any storeyed complete all as specified and directed by Engr-in-Charge.
Taking up and set aside the drain cover slabs and refixing the same with cement mortar 1:6, after cleaning the drain complete all as specified and as directed. (cleaning of drains shall be measured and paid separately)
Cleaning of open/Closed/storm water drain and removing all debris from the drain off the premises complete all as specified and as directed.
Demolition of Brick work or stone /boulders masonary , built in cement mortar or cement lime mortar including all quoions,arches,pillars etc, but excluding ashlar facings dressed stone work and precast concrete articles complete all as specified and as directed.
M & L cement concrete in 1:4:8 mix type D2 using (40 mm graded stone aggregate) as in foundatione etc complete all as specified and directed.
M & L for brick work with Fly ash bricks straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Rendering on fair faces of Brick surfaces or surface other than fair face of brick work or one side of lathing, 15 mm thick, in CM 1:4 finished even and smooth with using extra cement complete all as specified and as directed.
Supply only Water proofing compound
M&L for Preparing newly plasterd surfaces of walls and applying three coats of white wash complete all as specified and as directed.
M&L for PCC(1:2:4) mix type B2 (using 40mm graded aggregate) as in surface channels and drains complete all as specified and as directed.
M&L PCC(1:2:4) using 20mm graded aggregate as in bed block coping , or similar work and setting in cement mortar 1:6 complete with joint to match all as specified and as directed inclduing necessary form work , complete all as specified and as directed.
Demolition of cement concrete (reinforced) of any descritpion and in any position not otherwise specifically provided all as specified and as directed and depositing of the debris out of the premises complete all as specified and as directed.
M&L for precast reinforced cement concrete(1:2:4) mix type B1 using 20mm graded stone aggregate set in cement mortar (1:6)as in cover slab shelves etc complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape required inclduing cranking binding etc.., and including binding with mild steel wire (annealed) not less than 0.9mm dia all as specified and directed.
M&L for mild steel TMT bars 6mm to 8mm dia and over cut to length bent to shape required inclduing cranking binding etc.., and including binding with mild steel wire (annealed) not less than 0.9mm dia all as specified and directed.
M&L for Rough excavation not exc 1.5m deep and getting out in soft /loose soil all as specified and as directed.
M&L for Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soil etc complete all as specified and as directed.
M&L for Removing excavated Soil n.exc 50 m distance and deposited where directed at a level n.exc 1.50 m above the starting point all as specified and as directed.
S&F PVC grating 125mm size of PTMT dia fixed in repairs (minimum weight 100gms).
M&L for Demolition of plain cement concrete n.exc 15cm thick as in floors and plinth protection below and above ground level and disposting of debris off the premisses all as specified and directed.
M&L for 75mm thick PCC(1:3:6) type C2 (using 40mm graded stone aggregate) as plinth protection finished fair and even complete all as specified and directed.
M&L cleaning and removing all scale and dirt etc. from tanks and from mouths of circulating pipes etc exc. 250 litre and not exc. 500 litre and writing date of cleaning with white paint on each tanks complete all as specified and as directed.
M&L cleaning and removing all scale and dirt etc. from tanks and from mouths of circulating pipes etc exc. 500 litre and not exc. 1000 litre and writing date of cleaning with white paint on each tanks complete all as specified and as directed.
M&L cleaning and removing all scale and dirt etc. from tanks and from mouths of circulating pipes etc exc. 1000 litre and not exc. 2000 litre and writing date of cleaning with white paint on each tanks complete all as specified and as directed.
M&L cleaning and removing all scale and dirt etc. from tanks and from mouths of circulating pipes etc RCC Water Tanks upto 15000 litre capacity and writing date of cleaning with white paint on each tanks complete all as specified and as directed.
M&L for repairing the joints of WC by white cement mixed with WPC compound to stop the leakage complete all as specified and directed by Engineer -in- Charge.
M&L for repairing the sides of WC/Bath by white cement mixed with WPC compound to stop the leakage complete all as specified and directed by Engineer -in- Charge.
MONISH CONSTRUCTIONS (BID ID -3485251)
Sri Lakshmi and Company (BID ID -3479538)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
8254TENDER.pdf
Tender Documents • 0.57 MB
BOQ_826392.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid