Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC NARMADA COLONY BARADARI CHOURAHA MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹40.2 L+₹52,929.40 (1.33%)Rejected-Finance UDAIPUR GOMATI GOMATI TRIPURA 799120 | GOMATI | TRIPURA | 799120 | L2 | Rejected-Finance Other than L1 Bidder | |
| 3 | L3₹42.3 L+₹2.6 L (6.61%)Rejected-Finance | L3 | Rejected-Finance Other than L1 Bidder | |
| 4 | L4₹43.5 L+₹3.8 L (9.59%)Rejected-Finance C O PRAMOD KUMAR SHAH BUS STAND NANDPRAYAG NANDPRAYAG CHAMOLI UTTARAKHAND 246429 | NANDPRAYAG | CHAMOLI | UTTARAKHAND | 246429 | L4 | Rejected-Finance Other than L1 Bidder | |
| 5 | L5₹46.2 L+₹6.5 L (16.4%)Rejected-Finance 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L5 | Rejected-Finance Other than L1 Bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
17 Mar 2023, 6:00 pmClosed
Garrison Engineer Gwalior
Garrison Engineer Morar Cantt Gwalior
8834/GWL/E8 REPAIR REPLACEMENT OF UNSERVICEABLE PCC LIGHT POLES AT DIFFERENT LOCATION OF AGE BR-I AREA UNDER GE GWALIOR
2023_MES_576762_2
8834/GWL/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
Garrison Engineer Gwalior
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer Gwalior
₹96,000
Yes
29 Mar 2023
23 Feb 2023
20 Mar 2023
23 Feb 2023
17 Mar 2023
2 Mar 2023
Amount
Dismantling existing PCC LT Poles/rail poles, struts, any size carefully street light brackets including necessary excavation demolition of concrete transportation cost etc. and removing the old unserviceable rubbish etc
Dismantling existing PCC HT Poles/rail poles, struts, any size carefully including necessary excavation demolition of concrete transportation cost etc. and removing the old unserviceable rubbish etc
Dismantling ACSR conductor of any size from existing overhead service feeder etc all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m
Dismantling insulators any type, any size.
Dismantling stay assembly complete. (demolition of concrete, etc. and excavation measured separately)
S&F Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 50mm height, 65mm dia complete.
S&F Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts.
M&L for GI Brackets bending & shaping of size 32 mm dia galvanised iron pipe light grade over all length 0.60 mtr including necessary clamps, brackets and bolts etc to fixing on pole complete.
Excavation in trenches n exc. 1.5 m wide and exc 1.5m deep and n.exc 3.0 m deep for foundation beyond the first 1.5 m ,etc. or for shafts, wells cesspits, manholes, pier holes, etc. n exc.10 sq m on plan and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and as directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed.
M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete all as specified and directed.
M&L for PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded BT stone aggregate as in bed block for hold fast or coping including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L, Steel tublar swaged poles, complete with cast iron base plate, finials taper plug , bolts, nuts & screws as specified type 410 SP-31 (9.00 mtr long). Note : Earth work and PCC shall be measured & paid separately under respective items .
M&L, Steel tublar swaged poles, complete with cast iron base plate, finials taper plug , bolts, nuts & screws as specified type 410 SP-55 (11.00 mtr long). Note : Earth work and PCC shall be measured & paid separately under respective items .
M&L for ACSR conductor on existing or new poles all as directed.
M&L for refixing of ACSR conductor on existing or new poles all as directed.
Restringing and stretching of existing sagged LT ACSR conductor of any size on OH electric line of any length on existing poles after disconnection of binding wires (dismantling & taking down) service connection etc and making, binding and service connection complete all as directed.
M & L for GI Pipe light grade complete with fittings laid in floor/ trenches/ wall as cable protection of 100 mm dia all as specified and directed.
All as per item No. 21 but size 80 mm dia.
All as per item No. 21 but size 40 mm dia.
M&L for taking out the XLPE Cable of size 35 Sqmm to 185 Sqmm from existing PCC Pole and refixing with new Tublar Pole as per direction of Engr-in-charge.
M&L for taking out the XLPE Cable of size 185 Sqmm to 300 Sqmm from existing PCC Pole and refixing with new Tublar Pole as per direction of Engr-in-charge.
M&L for loop type insulator, vitreous porcelain white ,brown or green large size over all dimension 90 X 140mm, clearance of the hole 25.5mm for stay assembly complete all as specified and directed.
Fixing only of cross arm of any size on existing or new poles complete after drilling, cutting, scrabbing & 2 coat of aluminium painting etc retrieved against above said item complete.
M & L for cross arms, bracing, supports, clamps and back plated fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross arms complete all as specified and as directed.
M&L for stay assembly 16/20mm dia rod complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps, excavation and concrete measured separately) all as directed.
M&L for Galvanised steel wire 3.15 or 4mm stranded 7/1.6mm or 2.24mm
M&L for Earthing of machinery/equipment Installed at power house/substation, using 32 x 6 mm galvanized MS strip and MS galvanized plate of size 600 x 600 x 6 mm ,as earth electrode
M&L Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm
M&L Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 150sqmm
M&L Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 400sqmm
M&L LT Cable insulation protection sleeve Heat shrink type singal Core sleeve for LT Cable of size 25 sqmm to 50 sqmm .
M&L LT Cable insulation protection sleeve Heat shrink type singal Croe sleeve for LT Cable of size 70 sqmm to 150 sqmm .
M&L LT Cable insulation protection sleeve Heat shrink type singal Croe sleeve for LT Cable of size 185 sqmm to 400 sqmm .
S&F Cradles, hexagonal/rectangular,fabricated with galvanised steel wire 3.15 or 4mm dia
M&L Anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered (clamps measured separately
Anti-climbing device; spikes type fabricated out of M.S. bars (round,square and flat) including nuts,bolts,washers and welding in two halves made to shape to suit the cross section of the pole
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT,25x20cm size
Supply, laying and testing of cable XLPE insulated, armoured,heavy duty, electric LT UG cable with multi stranded aluminium conductor, 1100 Volts grade, of following size:-
16 Sqmm 4 core.
25 Sqmm 3.5 core.
35 Sqmm 3.5 core.
50 Sqmm 3.5 core.
70 Sqmm 3.5 core.
95 Sqmm 3.5core.
120 Sqmm 3.5core
240 Sqmm 3.5 core
400 Sqmm 3.5 Core
10 Sqmm 2 Core
Felling of trees exc 30 cm girth including cutting of trunk, and branches and stacking of serviceable material and disposal of unserviceable material to a distance of exc 50 m and clearing site.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed.
M&L for sand filling/cushioning in trenches for cable protection including consolidation complete all as directed.
Supplying and laying un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique of size 100mm dia.
M&L for painting of existing HT/LT pole/Security light pole of any size with one Coat of Aluminium paint over two coat of red oxide primer complete including Pole numering(6" Letter size with 4 digit/letter) fabrication work reqd complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe including provn of earth test point made of 50 x 5 mm MS Flat in 'D' shape 500 mm legth grouted in wall complete 01 x 6 mm multistrand PVC insulated copper conductor ( Green Colour) to be provided from test point to DB through 20 mm dia concealed non metallic conduit complete all as specified and directed.
M&L for refixing of street light brackets and light fitting on steel tublar pole with connection complete.
M&L for Fixing only Street light fittings with connection complete.
Maa Durga Electricals
Om Electricals
M/S SANJAY AGARWAL
M/s Shanti Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .