Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.9 L+₹1.8 L (6.87%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹30.8 L+₹4.7 L (18.0%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹32.1 L+₹6.0 L (22.9%)Rejected-Finance 47 VED NAGAR COLONY DEORI ROAD AGRA 282 001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹69,500
Closing Date
14 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Mathura
HQ CWE Mathura
As per tender documents
2021_MES_460632_1
CWE/MTR/E/24 OF 2021-22
Open Tender
Civil Works
Works
180 days
HQ CWE Mathura
Class D cat b(ii)
7 documents required · 7 mandatory
₹500
GE (East) Mathura
₹69,500
Yes
28 Aug 2021
16 Jul 2021
16 Aug 2021
16 Jul 2021
14 Aug 2021
31 Jul 2021
60 days
Amount
Disconnecting & taking out 11KV HT VCB of any description and any make of rating 400/630Amp, dismantling / opening of the VCB for preventive maintenance / servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etc and renewal of unserviceable parts with new one, re-assembling the VCB after overhauling / servicing and its testing complete and renewal of following unserviceable spare parts of make as approved by GE complete all as specified and directed by Engr-in-Charge. Notes :- (i) The quoted rate of contractor includes for fixing the serviceable parts in position and renewal of unserviceable parts with new parts. (ii) The new parts shall be measured and paid separately under appropriate item as supply only mentioned here-in-after (iii) Servicing to be carried out by service engineer of OEM.
Supply only Vaccum bottle suitable for 630 Amp, 11KV HT VCB.
Supply only Vaccum bottle suitable for 400 Amp, 11KV HT VCB.
Supply only Fixed arcing contact assembly suitable for 630 Amp 11KV HT VCB.
Supply only Moving arcing contact assembly suitable for 630 Amp 11KV HT VCB.
Supply only Fixed arcing contact assembly suitable for 400 Amp 11KV HT VCB.
Supply only Moving arcing contact assembly suitable for 400 Amp 11KV HT VCB.
Supply only Shunt trip coil 24-30 Volts DC suitable for 11KV VCB.
Supply only Spring charging motor 110-230 Volts AC 50 Hz suitable for 11KV VCB.
Supply only PVC spout assembly suitable for 11KV VCB/ Bus coupler.
M&L for checking tripping of 33/11KV circuit breakers through programming microprocessor based numerical relay/ IDMT over current and earth fault relays at plug setting intended in service by primary current injection in CT to ensure proper function of relays trip coil control circuit etc during fault condition complete all as specified and directed by Engr-in-Charge .
M&L for testing of over current & earth fault of programming microprocessor based numerical relay/ IDMT relays as per time/current characteristics by secondary injection test O/C 50%, 75%, 100%, 200% & E/F 20-80% plug setting and operating time at twice the set valve & TMS 1 including well cleaning and de-carbonizing of relay contacts complete all as specified and directed by Engr-in-Charge.
Disconnecting & taking out 33KV HT VCB of any description and any make of rating 400/630Amp, dismantling / opening of the VCB for preventive maintenance / servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etc and renewal of unserviceable parts with new one, re-assembling the VCB after overhauling / servicing and its testing complete and renewal of following unserviceable spare parts of make as approved by GE complete all as specified and directed by Engr-in-Charge. Notes :- (i) The quoted rate of contractor includes for fixing the serviceable parts in position and renewal of unserviceable parts with new parts. (ii) The new parts shall be measured and paid separately under appropriate item as supply only mentioned here-in-after (iii) Servicing to be carried out by service engineer of OEM.
Supply only Shunt trip coil 24-30 Volts DC suitable for 33KV VCB
Supply only Switch TNC (trip, neutral, close)
Dismantling insulators any type/ size from HT network complete all as directed by Engr-in-Charge.
Supply and fixing pin type insulator suitable for 11 KV, procelain vitreous white, brown or green of size 150 mm height and 150 mm dia, ISI marked including one galvanised steel spindle, two galvanised iron washers and one galvanised iron nut complete all as directed by Engr-in-Charge.
Supply and fixing post top insulator of 11 KV grade suitable for air break switch/ drop out fuse assy with necessary nuts, bolts, washers complete all as directed by Engr-in-Charge.
Supply and fixing in replacement lightning arrestor expulsion type complete with all fittings, transmission class discharge capacity 65 KA, 11000 volts including taking down existing unserviceable one complete all as directed by Engr-in-Charge.
M&L for repair/ Maint/ servicing of 33KV/ 400Amp GOD AB switch to made it proper functional by oiling/ greasing of mechanical operating mechanism and renewal of old rusted nuts/ bolts/ MS clamps/ handle and provide jelly between fixed and moving contacts complete all as specified and directed by Engr-in-Charge. Note :- (i) The rate quoted against this item shall be deemed to include cost of petroleum jelly, renewal of worn out nuts, bolts & washers, binding wire and PG clamps etc complete as required for proper functioning of GOD switch. (ii) Cost of item required to be replaced for making GOD switch serviceable will be measured and paid separately under appropriate item as supply only mentioned here in after.
Supply only female contact / fixed contact Jaw suitable for 33KV GOD AB switch of rating 400 Amp complete all as specified and directed.
Supply only male contact/ moving contact blade suitable for 33KV GOD AB switch of rating 400 Amp complete all as specified and directed.
Supply only tinned copper flexible jumper suitable for 33KV GOD AB switch of rating 400 Amp complete all as specified and directed.
Supply only MS jumper carrier suitable for 33KV GOD AB switch of rating 400 Amp complete all as specified and directed.
Supply only back connector plate suitable for 33KV GOD AB switch of rating 400 Amp complete all as specified and directed by Engr-in-Charge.
Material and labour for repairing /servicing of gang operating devices 11000 volts up to 400 Amps including cleaning, greasing all the moving parts and applying petroleum jelly at the contact points including dismantling and replacing all the unserviceable parts/ spares all as directed by Engr-in-Charge. Note :- (i) The rate quoted against this item shall be deemed to include cost of petroleum jelly, renewal of worn out nuts, bolts & washers, binding wire and PG clamps etc complete as required for proper functioning of GOD switch. (ii) Cost of item required to be replaced for making GOD switch serviceable will be measured and paid separately under appropriate item as supply only mentioned here in after.
Moving contact blades copper alloy (Male contact).
Fixed contact jaw copper alloy (Female contact).
Fault location of underground HT cable of any size or type with help of cable fault locator machine at site including removal of moisture content from the cable all as directed by Engr-in-Charge. Note :- The machine for fault location will be arranged by the contractor in the quoted rates. However, necessary excavation, earthwork, jointing materials will be measured and paid separately under relevant items of schedule.
Material and labour for taking out HT underground cable of any size or type from excavated trenches, repairing the same as required at site and relaying the cable after repair at same or another location as direcetd at site by Engr-in-Charge. Note - Necessary excavation, earthwork, jointing materials will be measured and paid separately under relevant items of schedule.
Disconnecting and taking down HT UG cable from HT pole/ transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, outdoor type with and including suitable size of heat shrinkable new jointing kit 11000 volts grade and aluminum lugs duly crimped with crimping tool for the following sizes of HT cables:-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm 3 core.
Disconnecting and taking down HT UG cable from HT pole/ transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, Indoor type with and including suitable size of heat shrinkable new jointing kit 11000 volts grade and aluminum lugs duly crimped with crimping tool for the following sizes of HT cables:-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm 3 core.
Supply and jointing HT cable with jointing kit for 11 KV (Earthed) grade cable for straight through heat shrinkable type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of following sizes of HT cables:-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm 3 core.
Dismantling unserviceable cross arms, clamps etc and removing from site all as directed by Engr-in-Charge.
Material and labour for cross arms, bracings, supports, clamps, hooks and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as directed by Engr-in-Charge.
Excavation in trenches for laying underground cable, erection of poles and stays in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed by Engr-in-Charge.
All as per item Srl No 18 here-in-before but in PCC/floor/road
Excavation in soft /loose soil in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth but not exceeding 3.0 mtr in depth and getting out complete.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing surplus excavated material to a distance not exceeding 50 meter above the starting point complete all as specified and directed by Engr-in-Charge.
Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr-in-Charge. Note :- Punned thickness shall be measured.
Supplying and laying un-reinforced precast concrete cable cover class HV type 1 with peak size 300 mm x 180 mm x 40 mm complete all as directed by Engr-in-Charge.
Supplying, laying, testing and commissioning in repair, XLPE insulated, screened, PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor ISI marked 11 KV grade (Earthed system) laid in trenches / on pole / in ducts or through sleeves of size 95 Sqmm 3 core complete all as directed by Engr-in-Charge.
All as per item 25 above but cross sectional area of size 120 Sqmm 3 core complete all as directed by Engr-in-Charge.
All as per item 25 above but cross sectional area of size 150 Sqmm 3 core complete all as directed by Engr-in-Charge.
All as per item 25 above but cross sectional area of size 185 Sqmm 3 core complete all as directed by Engr-in-Charge.
Dismantling steel tubular poles of any size complete all as specified and directed by Engr-in-Charge.
Supply and erecting steel tubular swaged pole with cast iron base plate, finial taper plug, bolts, nuts & washers as per IS 2713 (Part-II) 1980 made out of mild steel tubing, type 410 SP-55 (11 metre long) including marking pole No on pole including painting of poles with one coat of red oxide primer and two coat of aluminum paint (one coat before fixing and one coat of aluminum paint after fixing) over exposed surface and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enamelled paint upto 1.5m height complete all as specified and directed by Engr-in-Charge. Note : Earth work and PCC shall be measured separately.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping complete all as specified and directed by Engr-in-Charge.
M&L for painting of steel tubular HT pole 11 mtr including cross arms, clamps, back plates etc in situ with one under coat and one finishing coat of aluminum paint after cleaning/ preparation of surfaces including making yellow and black strips 30 cm wide 5 Nos with two coats of synthetic enamel paint all as directed by Engr-In-Charge.
All as per item No 34 here in before but for 2 pole structure including bracings.
All as per item No 34 here in before but for 4 pole structure including bracings.
Supply only electric rubber hand gloves 11 KV ratings.
Dismantling air break gang operated switch vertical/ horizontal mounted including insulators and operating mechanism and removing the same from site complete all as directed by Engr-in-Charge.
Material and labour for fixing air break gang operated switch outdoor type HT 11 KV triple pole mechanically operated mounted on HT insulators horizontal/ vertical type as existing at site including MS galvanised steel frame with operating mechanism worked from ground level including operating rod of size 32 mm dia GI medium grade for current rating of cap 200 Amps 11000 volts with locking arrangement, MS clamps, bolts, nuts and washers etc including two coats of aluminum paint over a coat of red oxide primer on MS work complete all as directed by Engr-in-Charge.
Supply and fixing in replacement drop out fuse assy single pole 11 KV, 25 Amps rating complete with expulsion fuse element mounted on four/two pole structures including necessary nuts, bolts and washers complete all as directed by Engr-in-Charge.
Supply and fixing in replacement galvanised steel tube, light grade laid along the pole/ in trenches / under road or floor of size 80 mm bore including removing the rusted old one complete all as directed by Engr-in-Charge.
Supply and fixing in replacement galvanised steel tube, light grade laid along the pole/ in trenches / under road or floor of size 100 mm bore including removing the rusted old one complete all as directed by Engr-in-Charge.
Supply and laying insulating mat for electrical installations, ISI marked of IS:15652 and of size 2 mtr x 1 mtr x 19 mm suitable for 11 KV system complete all as directed by Engr-in-Charge.
Material and labour for HT cable route indicators made out of PCC 1:2:4 type B1 duly rendered with plaster 10 mm thick of size 40 cm x 70 cm x 20 cm fixed & erected on PCC platform of size 40 cm x 40 cm x 10 cm grouted in ground duly painted on both sides with "HT cable Route" complete all as directed by Engr-in-Charge.
Material and labour for repair/rewinding to 0.16 HP three phase AOLTC electric motor (5 MVA transformer) including disconnecting and reinstallation after repair including testing and commissioning complete all as directed by Engr-in-Charge.
Vijay Electricals
Ms Kamal Kant Agarwal
neeraj electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .