Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC H NO 959 SECTOR 3 ROHTAK | L1 | Accepted-AOC accepted |
Tender Value
₹14.2 L
EMD Value
₹28,320
Closing Date
12 Oct 2021, 5:00 pmClosed
Executive Engineer
Electrical Division PWD BnR Br. Rohtak
Construction of Hospital Laundry in Pt. B. D. Sharma University of Health Sciences, Rohtak (Providing E.I. only)
2021_HRY_190069_1
PWD/Electrical/163612
Open Tender
Electrical Works
Item-rate/Agreement basic
60 days
Rohtak
Please refer to tender documents as per DNIT conditions.
3 documents required · 3 mandatory
₹1,000
₹28,320
Yes
7 Jan 2022
28 Sept 2021
13 Oct 2021
28 Sept 2021
12 Oct 2021
28 Sept 2021
Amount
20.71 Supply, Erection, Testing of Ceiling Fan IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-Charge
20.72 Supply, Erection, Testing of Exhaust Fan IS marked (as per IS code 374)having a capacity of 45 cubic meter per minute complete with suitable GI sheet ducting in structure confirming to latest IS specifications complete in all respects complete to satisfaction of Engineer-in-Charge
23.1.6 Wiring main sub mains and circuit wiring in Two single core for phase and neutral wire and one single core for each wire PVC insulated copper conductor cable 1100 volts grade in MS conduit etc complete as required
23.1.6.1 1 run of size 1.50 Sqmm (1/1.40 mm)
23.1.6.3 1 run of size 4 Sqmm (1/2.24 mm)
23.2 Copper Wiring with Modular Switches in MS Conduits
23.2.1 Wiring for Light/Fan/Call Bell point with modular typer switch / socket and GI box, Modular type face plate etc. in 1.5 Sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe
23.2.1.3 Group C
23.2.2 Wiring for Twin control light point with 2 Nos., 2-ways, 5 Amp. Modular switch GI Box and Modular face plate in 1.5 Sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe.
23.2.2.3 Group C
23.2.4 Wiring for in MS conduit system for 3 pin 5 amp. plug point by using 2 no. 1.5 sqmm FRLS copper wire and 1 No. 1.5 Sqmm FRLS copper wire, including providing 1 no. 5/6 Amp 3/5 pin modular type socket and 1 no. 5/6 Amp modular type switch required GI Box, Modular face plate etc. complete as required
23.2.4.3 Group C
23.2.5 Wiring in MS conduit system for 3 pin 15 amp. plug point by using 2 no. 4 sqmm FRLS copper wire and 1 No. 4 Sqmm FRLS copper wire for earthing, including providing 1 no. 15/16 Amp 3/6 pin modular socket and 1 no. 15/16 Amp modular switch required GI Box, modular face plate etc complete as required
23.2.5.3 Group C
23.6.6 Supply and Erection of MS conduit pipe 1.6 mm thick, ISI marked surface / recessed in slab / wall / ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of work
23.6.6.1 M S Pipe of 20 mm dia
23.6.6.2 M S Pipe of 25 mm dia
23.8 Fittings and Accessories.
23.8.1 Providing and fixing Paino type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connection, complete in all respect
23.8.1.12 Bakelite angle / straight button holder large size.
23.8.1.13 Socket size rotary step type Electronic regulator for AC ceiling fan
23.8.4 Supply and erection of 10.5 cm dia MS Fan box including 8 mm dia 30 cm long MS road made into suitable suspension hook and erected in RCC slab for the erection of fan complete with all labour and material required to complete the job
23.11 Making suitable hole in the wall suitable for exhaust fan upto 450 mm sweep including finishing the same and fixing of stainless steel wire mesh 2 mm thick having about 50 meshes per inch at exhaust side complete as required
23.22 MCCB, Distribution Boards, MCB's, RCCB's, Change Over etc.
23.22.1 Supply and erection of modular case circuit breaker single pole / 4 pole on existing wall / pedestal / panel including bounding to earth and making necessary connections required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge of the work.
23.22.1.3 Triple Pole MCCB 16 to 100 Amp., 25 KA
23.22.1.11 4 Pole MCCB 200 to 250 Amp., 25 KA
23.22.1.12 4 Pole MCCB 300 to 400 Amp., 50 KA
23.22.2 MCCB enclosure made of sheet steel suitable for mounting MCCB of following ratings
23.22.2.1 MCCB upto 125 A FP
23.22.4 Supply and erection of double door sheet steel enclosure distribution boards suitable for MCB's & ELCB's recessed in wall including bonding to earth complete with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work.
23.22.4.6 TPN DB Horizontal type Double Door 6 way (8 incoming and 3 phase * 6 outgoing)
23.22.4.7 TPN DB Horizontal type Double Door 8 way (8 incoming and 3 phase * 8 outgoing)
23.22.5 Supply and erection of miniature circuit breaker 240/ 415 V in the existing distribution board including making necessary connections
23.22.5.1 6 Amp. to 32 Amp. Single Pole
23.22.5.5 6 Amp. to 32 Amp. MCB's Triple Pole
23.22.5.6 40 Amp. to 63 Amp. MCB's Triple Pole
23.24.4.1 Load Bank 4 way 250 Amp.
23.24.4.4 Load Bank 8 way 400 Amp.
24.1 Earthing and Lightening Arrestor
24.1.1 Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. (but without charcoal or coke and salt) as required
24.1.2 Extra for using salt and charcoal/coke for earth electrode as required.
24.1.3 Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt ) complete as required
24.1.5 Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode
24.1.7 Supplying and laying of 25 mm x 3 mm G.I. Strip at 40 mm dia, GI Pipe as from earth electrode including soldering etc. as required
24.1.11 Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required
24.5.2 S/E of mark double walled corrugated (DWC) HDPE pipe10 Kg./Cm2 laid 0.75 mtr. below ground level including digging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-incharge of the work
24.5.2.3 DWC/HDPE pipe 63/50 mm outer dia / inner dia
24.5.2.4 DWC/HDPE pipe 90/75 mm outer dia / inner dia
M.R. items
NS-1 Supply & erection of double door (Indo Asian / Havells / standard make) sheet steel enclosure distribution board (Suitable for MCCB as incomer and MCB for outgoing circuit but without cost of MCCB / MCB etc. The distribution board duly recessed in wall / surface mounting necessary connections with all labour & material required to complete the job in all respect up to entire satisfaction of Engineer-in-charge of the work
i) 4 way TPN D. B.
ii) 6 way TPN D. B.
NS-2 S/E of underground cable loose in existing pipe or trenches complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work.
i) 10 Sqmm 4 Core Cable (Armd.)
ii) 16 Sqmm 4 Core Cable (Armd.)
iii) 25 Sqmm 3.5 Core Cable (Armd.)
iv) 70 Sqmm 3.5 Core Cable (Armd.)
v) 95 Sqmm 3.5 Core Cable (Armd.)
vi) 120 Sqmm 3.5 Core Cable (Armd.)
NS-3 Supply and Erection of LED Tube Fittings 18/20 W as supplied by the manufacturer complete in all respect. Make: - Crompton / C&S Electric/ Havells
NS-4 Supply and Erection of LED Tube Fittings 40 W as supplied by the manufacturer complete in all respect. Make: - Crompton / C&S Electric/ Havells
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .