Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC R O BHARDA KALAN P O TEH AKHNOOR PIN 181201 DISTT JAMMU J K | JAMMU | JAMMU AND KASHMIR | 181201 | L1 | Accepted-AOC DUE TO BEING L1 AND REASONABLE | |
| 2 | L2₹27.4 L+₹50,489 (1.87%)Rejected-Finance | L2 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 3 | L3₹27.6 L+₹66,056.25 (2.45%)Rejected-Finance | L3 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 4 | L4₹27.8 L+₹84,315.25 (3.13%)Rejected-Finance | L4 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 5 | L5₹28.6 L+₹1.6 L (6.03%)Rejected-Finance | L5 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
15 Aug 2022, 6:00 pmClosed
GE SOUTH AKHNOOR
GE SOUTH AKHNOOR C/O 56APO
SPECIAL REPAIR OF BATHROOMS OF BLDG NO T-86, SPECIAL REPAIR OF BLDG NO T-25, PROVN OF FIVE OF TWO AND FOUR WHEELER PARKING SHED IN MD ACCN AND OTHER SANCTIONED WORKS WITHIN AOR OF AGE B/R-II UNDER GE (SOUTH) AKHNOOR (SECOND CALL)
2022_MES_529965_2
GES/AKH-04/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH AKHNOOR
MES EN-LISTED CONTRACTOR WITH CLASS D WITH CATEGORY a(i)
9 documents required · 9 mandatory
₹50
GE SOUTH AKHNOOR
₹60,000
9 Oct 2022
30 Jul 2022
17 Aug 2022
30 Jul 2022
15 Aug 2022
2 Aug 2022
Amount
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each, complete all as specified.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each, complete all as specified.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), ncluding cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed by Engineer-In-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlars facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engineer-In-Charge.
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-In-Charge.
Dismantling timber scantlings 40 Sqcm and over in section, in any position, complete all as specified and as directed by Engineer-In-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed by Engineer-In-Charge.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and as directed by Engineer-In-Charge.
Providing and fixing board 4mm thick, designer, in ceiling fixed as per manufacturer’s instructions, including powder coated galvanised iron snap grid frame work of main and tee (weight not less than 240gm/Rm), angle (weight not less than 217 gm/Rm), grid size 595x595mm, for false ceiling all as specified, and hangers 6mm dia, galvanised iron (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of galvanised iron wire of 4.0mm dia, length as required at site and expansion hold fasteners 12.50mm dia, 40mm long, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) gully trap of 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, any radius, fixing with adhesive, complete all as specified and as directed by Engineer-In-Charge.
Septic tank for 20 users LLDPE (Linear Low Density Polyethylene) with upflow filter including media type with vent pipe, cowl etc. designed to carry sewage and sullage water, including excavation in any type of soil as per size of tank , PCC 1:4:8 Type D-2(using 40mm graded crushed stone aggregates)as bed concrete, lowering the septic tank and filling with water and return/filling with mix of coarse sand and Bajri around the septic tank and do inlet and outlet pipe connection etc complete all as specified and as directed. Make: Sintex /Comfort polymers/ Polycon.
Construction of soakage well of 1.2 mtrs dia and 3.0 mtrs in depth, in any type of soil including plain cement concrete M-10(1:3:6), type C-2 (using 40mm graded crushed stone aggregates) in foundation and honeycombed brick masonry in cement mortar 1:4 and reinforced cement concrete cover slab, M-25, type A-1 (using 20mm graded crushed stone aggregates), complete all as specified and as shown in drawing. Drawing No- CE/TD/1202/03 sheet 1/2 and 2/2 dated 09.10.03 revised 14.10.14 and 11.05.07.
Plain cement concrete M-10(1:3:6), type C-2 (using 40mm crushed stone aggregates) as in bed to drain pipes of 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; after laying, complete all as specified and as directed by Engineer-In-Charge.
Salt-glazed stoneware drain pipes, internal 150mm, laid in trenches and jointed in cement mortar 1:1, complete all as specified and as directed by Engineer-In-Charge.
Excavation in trenches n exc 1.5 metre wide & n. exc 1.5 metre in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes etc n. exc 10 Sqm on plan n. exc 1.5 metre in depth and getting out in any type of soil, complete all as specified.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil, omplete all as specified and directed.
Returning filling in incl spreading watering and well ramming in layers in hard/dense soil each not exceeding 25cm thick complete all as specified.
Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
Filling of earth under floor including spreading and levelling in layers n exc. 25cm thick & well ramming including watering as required, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge.
Hardcore of broken stone, gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified. Note: thickness of hard core shall not exceed from 100mm.
Plain cement concrete M-5.0(1:5:10), type E-2 (using 40mm graded crushed stone aggregate), as in sunken slab or as mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge.
Taking up or down steel tubing of 15mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed by Engineer-In-Charge.
Tubes, 'medium grade' galvanised, 15mm bore, ISI marked with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-In-Charge.
Refixing old steel tubing galvanised, 15mm bore, with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts and connections in new or old position (walls, ceiling, floors, etc.), complete all as specified and as directed by Engineer-In-Charge.
Taking up or down steel tubing of 20mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed by Engineer-In-Charge.
Tubes, 'medium grade' galvanised, 20mm bore, ISI marked with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-In-Charge.
Refixing old steel tubing galvanised, 20mm bore, with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts and connections in new or old position (walls, ceiling, floors, etc.), complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate), 50mm thick, as in plinth protection and providing the joints throughout the thickness, filled with mastic filling comprising bitumen 85/25 grade and sand mixture 1:3 by weight, complete all as specified and as directed by Engineer-In-Charge.
Glazed ceramic tiles in vertical surface/ dado, size 300x450mm/ 300x200mm, 6/7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, the shade/ colour of tiles including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
S&F Rotational moulded polyethylene water storage tanks of 500 liters capacity, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of Rotational moulded polyethylene water storage tanks of 1000 liters capacity, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) ‘P’ or ‘S’ trap, with grating of 100mm outlet dia including jointing to waste pipe fixed in plain cement concrete, M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and as directed by Engineer-In-Charge.
Non-skid, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) (Designer Pattern) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Non-skid, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Non-skid, joint free, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, set and fixing in skirting/ dado or any other vertical surfaces and pointed in white or coloured cement to match and including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed.
Non-skid, joint free, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, set and fixing in skirting/ dado or any other vertical surfaces and pointed in white or coloured cement to match and including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed.
Granite (of any type) work (table rubbed and polished), 15-18mm thick, as in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed by Engineer-In-Charge.
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-In-Charge.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-In-Charge.
Low density polyethylene (LDPE) pipes of 32mm bore, pressure rating 6.0 Kgf/Sqcm), 900mm long, complete all as specified and directed by Engineer-In-Charge.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 125x60mm, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-1, (using 20mm graded crushed stone aggregate), nominal mix, as in cills, steps; plinth courses, string courses, lacing courses, copings, kneelers, apex stones, bed plates and in hold fasts or filling in hollow of steel frame, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
Factory made steel window, box type, using ERW hollow 'P' section, comprising double frame for and including gauged and glazed skeleton shutter with wire mesh and plain sheet glass 3.0mm thick, 4mm thick frosted glass, jointed internally and made with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and as shown in drawing No- CEUZ/TD-1304, sheet No- 1/3 to 3/3 and as directed by Engineer-In-Charge. Note :- Cost of window shall include all members and spare parts as elaborated in the Drwaing and in the specifications and nothing shall be paid extra seperately.
Factory made, glazed and skeleton shutters in second class hardwood, 35mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats, complete all as specified and as directed by Engineer-In-Charge.
Factory made, 35mm thick, second class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new or previously untreated wood or wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed by Engineer-In-Charge.
Angle valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, fixed in repairs, complete all as specified and as directed.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed for 15mm bore pipe, fixed in repair, complete all as specified and as directed.
Solid PVC Door Frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specification and drawing, including making good to disturbed surface of walls, complete all as specified.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing in SSR, complete all as specified and as directed.
Butt hinges, size 100mm, medium weight, cold rolled mild steel, and fixed, complete all as specified and as directed by Engineer-In-Charge.
Aluminium anodised, barrel tower bolts of extruded Section, size 150mm long and fixed, complete all as specified and as directed by Engineer-In-Charge.
Aluminium handles, cast type, anodised, size 150mm, complete all as specified and as directed by Engineer-In-Charge.
Aluminium alloy, anodised, sliding door bolt, size 300mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed.
Mild steel spring for doors, 300mm, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-In-Charge.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, cverall length of cover plate 150mm, fixed in floor, complete all as specified and as directed.
Curtain rod, 20mm dia, mild steel, fancy type, any colour coated, pvc layered with fixing and including end knobs, fixing brackets/ clamps, stops, round rings to hold the curtain, fixing in repairs with wall plugs and screws, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed.
M&L for preparation of old painted steel surfaces of any description not other wise described over 10cm width or girth and applying one coat (finishing coat) of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
Galvanised mild steel wire cloth in repair, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, , complete all as specified and as directed by Engineer-In-Charge.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness M-40 Grade laid over and including 30mm thick well rammed sand cushion laid over and including sub base of 100mm thick of plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), with grey cement and no pigment, complete all as specified and as directed by Engineer-In-Charge. , complete all as specified and as directed by Engineer-In-Charge.
Dura tuff pave-n-park cement concrete coloured tiles size 300mmx300mmx10mm, with chequered finish, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:4 laid over and including sub base of 100mm thick of plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), with grey cement and no pigment, complete all as specified and as directed by Engineer-In-Charge., complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-15(1:2:4), type B-1, (using 20mm graded crushed stone aggregate), nominal mix, as in kerbs, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound @ 3% by weight in cement, rendering is to be finished even and smooth (without using extra lime or cement), complete all as specified and as directed by Engineer-In-Charge. Note: Cost of water proofing compound shall deemed to be included in quoted rates.
Precast reinforced cement concrete M-20(1:1.5:3), type A-1, (using 20mm graded crushed stone aggregate), nominal mix, as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs and similar articles with plain faces as specified in clause No- 4.11.16 of SSR Part-I (2009), set in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-In-Charge.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed by Engineer-In-Charge.
Stainless steel grating, chromium plated, size 125mm, heavy duty, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Stainless steel grating, chromium plated, size 125mm, heavy duty, complete all as specified and as directed by Engineer-In-Charge.
M&L RCC M-25 design mix using 20 mm graded stone aggregate in foundations, including rafts, footings, foundation beams, plinth beams, base for columns, basements slabs, Slab supported on walls, columns etc including necessary form work, complete all as specified and directed. Note: Cost of necessary form work shall be deemed to be included in the quoted rates.
Vitreous China wash hand basin, white, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper including brackets of any size, including cutting for and pinning in ends of brackets or erecting stand including fixing and supply of waste pipe of 32mm dia and waste coupling, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Vitreous China wash hand basin, white, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper including brackets of any size, including cutting for and pinning in ends of brackets or erecting stand including fixing and supply of waste pipe of 32mm dia and waste coupling, , complete all as specified and as directed by Engineer-In-Charge.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. but including concrete bedding layer fixed in repair, complete all as specified and as directed by Engineer-In-Charge.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. but including concrete bedding layer , complete all as specified and as directed by Engineer-In-Charge.
PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, capacity 10.0 liters and making good to dismantled/ damaged floor/ surfaces, fixing in repair, complete all as specified and as directed by Engineer-In-Charge.
PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, capacity 10.0 liters, complete all as specified and as directed by Engineer-In-Charge.
Flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Vitreous China urinal, half stall, flat back, size of 465x355x265mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern and flush pipe but including of waste pipe), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing flush pipe, grating and union for discharge pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, conforming to Fe-410 (Gde-E-250) quality-B, complete all as specified and as directed by Engineer-In-Charge.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
All as per srl item No 85.00 above but except bricks.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Rolled mild steel in Joist, channel, angle, or tee sections, fixed with connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) and similar work conforming to Fe-410 Gde E-250 complete with necessary welding for connecting each other, complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick, on any surface of brick or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick, on fair faces of brick or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Rendering 5mm thick on any type of surfaces, on ceiling, in cement mortar 1:3, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
PVC connections 15mm size with brass nuts of length 450mm, complete all as specified and as directed by Engineer-In-Charge.
Bib taps, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Bib taps, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
Stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 20mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
Stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
Soap dish, fancy type, fixed to plugs with chromium plated brass screws, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of cement paint , complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregate), 150mm thick, as in sub base of floors, finish even to recive floor finishes, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) bends of 75mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, any radius, fixing with adhesive, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) bends of 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, any radius, fixing with adhesive, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) pipes, 75mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, single socketed, in any length with rubber ring joints, laid in trenches/fixed to wall, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) pipes, 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, single socketed, in any length with rubber ring joints, laid in trenches/fixed to wall, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) junction single, (Single T) equal or unequal, of 110mm bore, fixing with adhesive, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) floor/Nahani trap of 75mm dia outlet, plain with grating including jointing with solvent cement, complete all as specified and as directed by Engineer-In-Charge.
S&F 75mm PVC (SWR) vent cowl, complete all as specified and directed
Forming Contraction (Dummy) joints 65mm deepx10mm wide, filled with sealing compound grade 'A', complete all as specified and as directed by Engineer-In-Charge.
Applying one coat of neat cement slurry with 3.0 Kg of cement per Sqm on cleaned surfaces of roof, evenly, and screed bed/rendering 10mm thick on fair faces of brick work or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound @ 3% by weight in cement, rendering is to be finished even and smooth (without using extra lime or cement) including Water proofing treatment on roof top with APP (Ataxic Poly Propylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density polyethylene film, minimum weight not less than 3.0 Kg/ Sqm, 2.0mm thick, centre core is sandwiched on both sides by high quality polymeric mix with properties of high softening point, high heat resistance and cold resistivity to make it ideal for all water proofing treatment, with polymeric mix protection on both sides with 20 micron HMHDPE film, laid over one coat of bituminous primer conforming to IS: 3384, applied @0.40 Kg/ Sqm and one coat of hot blown bitumen of 85/25 grade, conforming to IS:702, applied @1.20Kg/ Sqm on prepared surfaces of roof, overlap should be not less than 150mm at ends and 75mm at sides, joints and overlaps uniformly bounded with LPG torch flame including applying of one coat of semi hot blown bitumen of 85/25 grade, @1.20 Kg Sqm and fine screened sand in dry condition @0.50 Kg/ Sqm after laying the membrane and applying two coats of aluminium paint, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of water proofing chemical shall be included in quote rate.
M&L RCC M-20 nominal mix using 20 mm graded stone aggregate as in slab supported on walls, beams and columns in floors, roofs landings balconies, canopies, deck slabs and in shelves and the like incl necessary form work, complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whitening, preparatory to distempering, after making surface smooth with 3mm thick birla white wall care putty, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white washing, complete all as specified and as directed by Engineer-In-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed by Engineer-In-Charge.
Point wiring for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. Note: Wherever modular point wiring is required then Cost of modular boxes, modular cover plates and different types of modules including anti-corrosive screws shall be deemed included in quoted rate.
Description all as per serial item No- 113.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 113.00 here in before but for one 3-pin socket outlet 5-Amps on the independent board.
Point wiring for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheeathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. Note: Wherever modular point wiring is required then Cost of modular boxes, modular cover plates and different types of modules including anti-corrosive screws shall be deemed included in quoted rate
Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, one way, 15 Amps, complete all as specified and as directed by Engineer-In-Charge.
Socket outlet, 2-in-1, 3-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Socket outlet, 2-in-1, 3-pin, 5 and 15 Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Modular switch piano, single pole, one way, 5/10 Amps, 1/2 module complete all as specified and as directed by Engineer-In-Charge.
Modular switch 1 way 16A, 1/2 module 240 Volts, complete all as specified and directed by Engineer-In-Charge.
Shuttered Socket outlet modular type, 6A -5 pin combined 2 module, 240 Volts, complete all as specified and directed by Engineer-In-Charge.
Shuttered Socket outlet modular type, 6/16A -6 pin combined 2 module, 240 Volts, complete all as specified and directed by Engineer-In-Charge.
Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-In-Charge.
Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge.
Modular stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.
T bulb curve, 12 Watt LED base B22 cool day light, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged LED mirror light, including LED lamp capacity 5/6 Watt, wall mounted, 300mm long, complete all as specified and as directed by Engineer-In-Charge. Make: Havells/ Philips/ Osram/ Crompton.
LED tube light fitting, 18 watt, indoor decorative aluminium extruded T5 LED battens, including LED lamp 18 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- E-Lite LED Pride Plus Neo LHEXBTP7IN1W018/ Crompton cat part LCTL-18-CDL/ Bajaj product code-12410, luminaire type- BCLSB 18 NW.
Replacement of old unserviceable/ damaged LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection, including LED lamps of 45 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified. Make: Havells cat part No- Endura Pearl Neo SL45WLED757SASYTOPC/ Philips ordering code No- 910925866055 (Product Code- 871869634894900)/ Bajaj ordering code No- 169799 (Product Code- BRTFG 45W LED I).
LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection, including LED lamps of 45 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified. Make: Havells cat part No- Endura Pearl Neo SL45WLED757SASYTOPC/ Philips ordering code No- 910925866055 (Product Code- 871869634894900)/ Bajaj ordering code No- 169799 (Product Code- BRTFG 45W LED I).
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-40)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth and getting out, in any type of soil, for foundations/ laying of cables/pipes, complete all as specified and as directed by Engineer-In-Charge.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified.
S&F in replacement of Ceiling fan, mettalic, sweep 1200mm, with BLDC Motor, high speed, inclduing necessary fitting/fixtures such as Hook and clamps etc including connectig wire of suitable size and length from ceiling rose to fan connector, complete all as specified and as directed. Make: Havells / Crompton Greaves/ Usha / Orient Electric energy star Note: Old Ceiling fan taken out from the existing opening and shall be deposited at Store Yard of MES and shall be the property of Deptt.”
Supply, laying commissioning, testing of the XLPE LT cable 1100 volts grade of size 10 Sqmm 2 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches/fixing on wall in PVC conduit pipe with the help of clamp/shadels, under road crossing through protection pipe etc after taking out existing under ground cable, complete all as specified and directed.
S&F in replacement of MCB, Single Pole and Neutral, 40-63 Amps (up to), 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 4-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 12-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
S&F Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 2-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged Sub main wiring (concealed conduits to surfaces) for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 2.50 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
Exhaust fan, mettalic, sweep 250/ 230mm, superior rating for energy saving, mettalic blades, copper wounded motor complete with electronic fan regulator including hanging accessories i.e. U-clamp, down rod, canopy and nut bolts, washers, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- FHVDBMTGRY09 (Ventilair DB Neo)/ Crompton Greaves/ Usha/ Bajaj/ Orient. Note: Old Exhaust fan taken out from the existing opening and shall be deposited at Store Yard of MES and shall be the property of Deptt..
Exhaust fan, mettalic, sweep 250/ 230mm, superior rating for energy saving, mettalic blades, copper wounded motor complete with electronic fan regulator including hanging accessories i.e. U-clamp, down rod, canopy and nut bolts, washers, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- FHVDBMTGRY09 (Ventilair DB Neo)/ Crompton Greaves/ Usha/ Bajaj/ Orient.
Supply and fixing 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 4 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 metre apart Including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged Industrial Bulkhead luminaire environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head back-lit LED luminaire comprising of high brightness LED 10 Watt and fixing matrials such as clamps, nuts, bolts, washers etc completed including taking down old unserviceable fittings, complete all as specified and as directed by Engineer-In-Charge. Make: Havells Cat Part No- HEXAFT10WLED857SSYMBOPC or equivalent in Philips/ Bajaj.
Amount of Schedule of credit of for Rs 46,933.00 shall be deducted from quoted amount.
M/s Cosmos Builder and Developer
m/s vaid contractor and builders
M/s Vishal Engineers
KRISHNA BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .