Loading…
Loading…
Tender ID
Tender Value
Refer Docs
Closing Date
18 Jun 2026, 3:00 pmClosed
Registrar BBAU
Registrar BBAU
Replacement of damaged water tank connection of water line from existing borewell to terrace tank of Guest House
2026_BBAU_912529_1
BBAU/Civil/2026/380
Limited
Civil Works
Percentage
30 days
BBAU
Please refer Tender documents.
1 document required · 1 mandatory
₹0
Exempted
11 Jun 2026
11 Jun 2026
19 Jun 2026
11 Jun 2026
18 Jun 2026
11 Jun 2026
11 Jun 2026 - 13 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. | 4 | each | 433.75 | ₹1,735 |
| 2 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore | 10 | metre | 149.8 | ₹1,498 |
| 3 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | 12,000 | per litre | 11 | ₹1,32,000 |
| 4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes | 120 | metre | 401.55 | ₹48,186 |
| 5 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25 mm nominal bore, weighing not less than 62 gms | 12 | each | 113.35 | ₹1,360.2 |
| 6 | Providing and fixing of 25 mm cpvc stop valve | 12 | each | 750 | ₹9,000 |
| 7 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore | 2 | each | 911.9 | ₹1,823.8 |
| 8 | Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 100 mm dia | 30 | metre | 713.2 | ₹21,396 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
BOQ_959009.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .