Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC | ₹1.0 Cr Quoted ₹1.1 Cr | L1 | Accepted-AOC Being 1st lowest |
| 2 | L2₹1.1 Cr+₹1.8 L (1.72%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.1 Cr+₹1.8 L (1.72%) | L2 | Rejected-Finance Being 2nd lowest |
| 3 | L3₹1.1 Cr+₹2.5 L (2.32%)Rejected-Finance | ₹1.1 Cr+₹2.5 L (2.32%) | L3 | Rejected-Finance Being 3rd lowest |
| 4 | L4₹1.1 Cr+₹4.3 L (4.00%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | ₹1.1 Cr+₹4.3 L (4.00%) | L4 | Rejected-Finance Being 4th lowest |
| 5 | L5₹1.1 Cr+₹4.3 L (4.03%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹1.1 Cr+₹4.3 L (4.03%) | L5 | Rejected-Finance Being 5th lowest |
| Sl No | Description | Qty | Unit | somnath engineering corporation L1 | BRITE INDUSTRIES L3 | pk Enterprises L4 | Shree Ayyappa Engineering L2 | cooltech engineering services L5 | Veer High Tech Solution L6 | RADHA ENTERPRISE L7 | DARSHAN CONSTRUCTION Co. L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | PART - I :
(a) B/R Works
Taking down chowkats or frames exc 1.5sqm but not exc 4 sqm each but with shutter (without taking off shutter from the frame), complete all as specified and as directed by Engr-in-Charge. | 7 | Each | 250 ₹1,750 | 220 ₹1,540 | 150 ₹1,050 | 347 ₹2,429 | 352 ₹2,464 | 120 ₹840 Lowest | 150 ₹1,050 | 357 ₹2,499 |
| 2.00 | Dismantling structural steel work including doors, gates but excluding framed truss etc, complete all as specified and as directed by Engr-in-Charge. | 14.5 | Qtl | 580 ₹8,410 | 400 ₹5,800 | 150 ₹2,175 Lowest | 603 ₹8,743.5 | 608 ₹8,816 | 320 ₹4,640 | 444 ₹6,438 | 617 ₹8,946.5 |
| 3.00 | Material and Labour for greasing and easing in position of mild steel rolling shutters of area not exc 10sqm each for full movement and for easy operation for shutters including taking down of old Shutter , complete all as specified and as directed by Engr-in-Charge. | 6 | Each job | 925 ₹5,550 Lowest | 2,100 ₹12,600 | 1,487 ₹8,922 | 1,414 ₹8,484 | 1,419 ₹8,514 | 1,551 ₹9,306 | 1,600 ₹9,600 | 1,500 ₹9,000 |
| 4.00 | Material and Labour for greasing and easing in position of mild steel rolling shutters of area exc 20sqm and not exc 50sqm each for full movement and for easy operation for shutters including taking down of old Shutter, complete all as specified and as directed by Engr-in-Charge. | 4 | Each job | 2,200 ₹8,800 Lowest | 3,323 ₹13,292 | 2,951 ₹11,804 | 2,887 ₹11,548 | 2,892 ₹11,568 | 3,057 ₹12,228 | 2,900 ₹11,600 | 2,979 ₹11,916 |
| 5.00 | Material and Labour in repair for Opening of rolling shutter hood cover, greasing to gears, helical spring and guide channels and refixing all accessories back in position of area not exc 10sqm each, complete all as specified and as directed by Engr-in-Charge. | 5 | Each job | 920 ₹4,600 | 900 ₹4,500 | 533 ₹2,665 | 527 ₹2,635 Lowest | 532 ₹2,660 | 543 ₹2,715 | 1,200 ₹6,000 | 535 ₹2,675 |
| 6.00 | Material and Labour in repair for Opening of rolling shutter hood cover, greasing to gears, helical spring and guide channels and refixing all accessories back in position of area exc 20sqm and not exc 50sqm each, complete all as specified and as directed by Engr-in-Charge. | 4 | Each job | 1,150 ₹4,600 | 778 ₹3,112 | 697 ₹2,788 | 691 ₹2,764 Lowest | 696 ₹2,784 | 717 ₹2,868 | 1,100 ₹4,400 | 707 ₹2,828 |
| 7.00 | Supply and Fix Steel rolling shutters, with out ball bearing, thickness of laths 1.00mm as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type including taking down of old Shutter, complete all as specified and as directed by Engr-in-Charge. | 10 | Sqm | 3,750 ₹37,500 | 3,270 ₹32,700 | 2,571 ₹25,710 | 2,515 ₹25,150 Lowest | 2,520 ₹25,200 | 2,610 ₹26,100 | 3,450 ₹34,500 | 2,583 ₹25,830 |
| 8.00 | Supply and Fix Steel rolling shutters, with out ball bearing, thickness of laths 1.00mm as specified including top cover, anchoring rod, hasp and staple and erected in position as indicated, complete: gear operated type with bevel gear box and crank handle including taking down of old Shutter complete all as specified and directed by Engr-in-Charge | 60 | Sqm | 4,200 ₹2,52,000 | 3,144 ₹1,88,640 | 2,837 ₹1,70,220 | 2,800 ₹1,68,000 Lowest | 2,828 ₹1,69,680 | 2,919 ₹1,75,140 | 2,872 ₹1,72,320 | 2,873 ₹1,72,380 |
| 9.00 | Material and Labour for preparing new or previously untreated steel surface of any description over 10cm in width or girth and applying 2 coats of aluminium paint over one coat of red oxide primer, complete all as specified and as directed by Engr-in-Charge. | 154 | Sqm | 90 ₹13,860 Lowest | 100 ₹15,400 | 123 ₹18,942 | 117 ₹18,018 | 145 ₹22,330 | 101 ₹15,554 | 92 ₹14,168 | 127 ₹19,558 |
| 10.00 | Material and Labour for preparing old painted steel surface of any description over 10cm in width or girth and applying one coats of aluminium paint, complete all as specified and as directed by Engr-in-Charge. | 40 | Sqm | 60 ₹2,400 | 78 ₹3,120 | 78 ₹3,120 | 53 ₹2,120 Lowest | 81 ₹3,240 | 71 ₹2,840 | 66 ₹2,640 | 63 ₹2,520 |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
5 Aug 2025, 6:00 pmClosed
CWE Karanja
CWE Karanja, Naval Station Karanja, Uran, Raigad, Maharashtra
COMPREHENSIVE REPAIR / MAINTENANCE OF CHILLERS, AHU UNIT, COOLING TOWER, COMPRESSOR, CONDENSOR, EXPANSION VALVES OF AC PLANT ALONGWITH ALLIED B/R WKS OF ZONE I LOCATIONS OF NAD EXPLOSIVE AREA AT NAVAL STATION KARANJA
2025_MES_719200_1
84461-K/E8
Open Tender
Electrical and Maintenance Works
Item Rate
420 days
Naval Station Karanja
Please refer Tender Documents
8 documents required · 8 mandatory
₹1,000
GE (NW) Karanja
₹1.9 L
29 Sept 2025
8 Jul 2025
7 Aug 2025
8 Jul 2025
5 Aug 2025
29 Jul 2025
Amount
PART - I : (a) B/R Works Taking down chowkats or frames exc 1.5sqm but not exc 4 sqm each but with shutter (without taking off shutter from the frame), complete all as specified and as directed by Engr-in-Charge.
Dismantling structural steel work including doors, gates but excluding framed truss etc, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for greasing and easing in position of mild steel rolling shutters of area not exc 10sqm each for full movement and for easy operation for shutters including taking down of old Shutter , complete all as specified and as directed by Engr-in-Charge.
Material and Labour for greasing and easing in position of mild steel rolling shutters of area exc 20sqm and not exc 50sqm each for full movement and for easy operation for shutters including taking down of old Shutter, complete all as specified and as directed by Engr-in-Charge.
Material and Labour in repair for Opening of rolling shutter hood cover, greasing to gears, helical spring and guide channels and refixing all accessories back in position of area not exc 10sqm each, complete all as specified and as directed by Engr-in-Charge.
Material and Labour in repair for Opening of rolling shutter hood cover, greasing to gears, helical spring and guide channels and refixing all accessories back in position of area exc 20sqm and not exc 50sqm each, complete all as specified and as directed by Engr-in-Charge.
Supply and Fix Steel rolling shutters, with out ball bearing, thickness of laths 1.00mm as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type including taking down of old Shutter, complete all as specified and as directed by Engr-in-Charge.
Supply and Fix Steel rolling shutters, with out ball bearing, thickness of laths 1.00mm as specified including top cover, anchoring rod, hasp and staple and erected in position as indicated, complete: gear operated type with bevel gear box and crank handle including taking down of old Shutter complete all as specified and directed by Engr-in-Charge
Material and Labour for preparing new or previously untreated steel surface of any description over 10cm in width or girth and applying 2 coats of aluminium paint over one coat of red oxide primer, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for preparing old painted steel surface of any description over 10cm in width or girth and applying one coats of aluminium paint, complete all as specified and as directed by Engr-in-Charge.
Supply and Fix for Providing and fixing in repair ball bearing for rolling shutters, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for mild steel Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for mild steel Framed work for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. conforming to Fe.290 Gde-E-165, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for clean sawn timber fixed Second class soft-wood in scantlings, complete all as specified and as directed by Engr-in-Charge.
Supply and Fix Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws , complete all as specified and as directed by Engr-in-Charge.
Material and Labour for 4 mm thick ACP cladding, in wooden flush doors or WPC Doors and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and as directed by Engr-in-Charge.
Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183. Density 16 kg/m³, 50 mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling or inside door frames and held in position by criss-crossing GI wire, complete all as specified and as directed by Engr-in-Charge.
Supply and Fix Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note:- For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Supply and Fix Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note:- stainless steel butt hinges and necessary SS screws shall be paid separately)
Supply and Fix extruded aluminium alloy handles fabricated type anodized 150 mm size, complete all as specified and as directed by Engr-in-Charge.
Supply and Fix Mild steel pressed handles, oval type, stove enamelled black 150 mm size, complete all as specified and as directed by Engr-in-Charge.
Supply and Fix mild steel work, Grade Fe-410-0 or Fe- 310-0, as in flat iron (for holdfast), complete all as specified and as directed by Engr-in-Charge.
Material and Labour for Providing and fixing IS : 12817 marked stainless steel butt hinges of size 100 x 58 x 1.90mm with stainless steel screws etc, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for mild steel Butt hinges, heavy weight, cold rolled mild steel, and fixed 125 mm long, complete all as specified and as directed by Engr-in-Charge.
Supply and Fix 200mm long aluminium anodized barrel tower bolts of extruded sections, complete all as specified and as directed by Engr-in-Charge.
Supply and Fix 300 mm Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, complete all as specified and as directed by Engr-in-Charge.
Supply and Fix 300mm long aluminium alloy, anodized sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet cost of extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for 375 mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for PCC 1:3:6, type C1 (using 20 mm graded aggregates) coping or filling for hold fast without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for preparation of new or untreated steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for greasing and easing in position of mild steel gate of area .exc 15 sqm and n.exc 40sqm each for full movement and for easy operation for shutters , complete all as specified and as directed by Engr-in-Charge.
Complete Removal of existing water proofing treatment any description up to concrete surface of roof slab including cleaning, with wire brushing, watering, removal of debris upto 1500 m distance, complete all as specified and as directed by Engr-in-Charge. Note :- Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work
Demolition of cement concrete (unreinforced) roof or chajja padding of any description and any position not otherwise specifically provided for complete and PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in roof/chajja padding for maintaining roof/chajja slope, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for applying oil bound primer @ 0.40 Litre/Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg/Litre at 25 degree Celsius on the prepared dry roof surface and provide and lay 4mm thick APP modified water proofing membrane reinforced with non-woven polyester matt with physical properties as given in particular specification. The laying shall got be done through authorized applicator of manufacturer as specified in particular specifications. Provide over the membrane finishing with two coats of solar reflective bituminous aluminium paint @ 0.10 Kg/sqm as prescribed by manufacturer of membrane including Ten years guarantee on prescribed form complete all as per particular specification , manufacturers instructions and as directed by Engineer-in-Charge.
Material and Labour for rendering 10mm thick cement plaster in CM (1:3) on roof top surface including WPC by weight of 3% of total cement content, complete all as specified and as directed by Engr-in-Charge. Note : WPC will be measured separately
Supply only liquid water proofing compound, complete all as specified and as directed by Engr-in-Charge.
Supply and Fix in repair 4 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/ GI/ Aluminium framework with screws in ceiling flat or sloping, complete all as specified and as directed by Engr-in-Charge. Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.
Material and Labour for preparing asbestos & ceiling board surfaces and applying two coats of oil bound distemper over a coat of chalk whitening on plastered surfaces, complete all as specified and as directed by Engr-in-Charge. Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.
Dismantling wall and ceiling boards or insulation boards, any thickness, any description, including cover fillets , complete all as specified and as directed by Engr-in-Charge. (Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.)
Supply and Fix Anodised aluminium snap grid of size 600x600 mm frame work for false ceiling complete all as specified and directed by Engr in Charge.
Supply and Fix Hangers 6 mm dia GI ( upto 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long , complete all as specified and as directed by Engr-in-Charge.
Supply and Fix 4 mm thick asbestos cement plain building board fixed to aluminium grid frame work in ceiling , complete all as specified and as directed by Engr-in-Charge. (Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.)
Demolition of cement concrete in ground floor and paving not exceeding 15cm thick below or above ground level un re-inforced , complete all as specified and as directed by Engr-in-Charge.
Material and Labour for PCC 1:4:8 type D2, using (40 mm graded aggregates) ,100 mm thick as in sub base of flooring, complete all as specified and as directed by Engr-in-Charge.
Supply and Fix in repairs PVC tiles /sheets, of 2mm thick laminated plain coloured homogenous, laid with approved rubber based adhesive in floors, complete all as specified and as directed by Engr-in-Charge.
Material and Labour PCC 1:2:4 type B2, using (40 mm graded aggregates) ,100 mm thick as in flooring, complete all as specified and as directed by Engr-in-Charge.
Material and Labour PCC 1:3:6, type C2 (using 40 mm graded aggregates) 75 mm thick as in plinth protection without using extra cement complete, complete all as specified and as directed by Engr-in-Charge.
Taking down cement plaster on brick walls or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc including removing debris directed for a distance max upto 500m , complete all as specified and as directed by Engr-in-Charge.
Material and Labour for rendering 15 mm thick on fair faces of brick/concrete surfaces cement plaster in CM (1:4) , finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Material and Labour rendering 15mm thick on fair faces of brick work or concrete surfaces of walls in cement mortar 1:6 finished even and smooth (with out using extra cement), complete all as specified and as directed by Engr-in-Charge.
Material and Labour rendering 5mm thick in CM 1:3 on ceiling finished even and smooth including sagol finish, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for preparation of new or previously untreated plastered surfaces of walls and applying two coats of acrylic antifungal paint exterior grade paint plain or camouflage pattern on one coat of primer, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for preparing new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whitening on plastered surfaces, complete all as specified and as directed by Engr-in-Charge.
Material and Labour preparation of new plastered surface of ceiling and applying three coat of white wash on ceiling, complete all as specified and as directed by Engr-in-Charge.
Demolition of pre-cast concrete block masonry built in cement mortar including all quoins, arches, pillars etc. and pre cast concrete articles, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for pre-cast cement concrete block masonry with solid blocks in 10cm in width in type B1 (1:2:4) and setting in mortar (1:6) , complete all as specified and as directed by Engr-in-Charge.
Supply and Fix rubber sponge gasket of 20mm thick and 40mm width fixed with and including approved adhesive, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for preparation of old wall surfaces of any description & applying one coat of acrylic (antifungal) exterior grade paint of camouflage pattern, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for preparation of old plastered / decorated surfaces of walls and applying one coat of oil bound distemper on plastered/decorated wall surfaces including preparing surfaces with application of putty wherever required, complete all as specified and as directed by Engr-in-Charge.
PART - I : (b) E/M Works Taking down carefully copper /aluminium point wiring (light, fan socket or power) through stove enamelled steel conduit/pvc conduits including complete fittings such as switches, ceiling roses, pendants, regulators, sockets,, switch sockets, electrical fittings etc removing and making good disturbed surfaces of walls/ceiling etc, complete all as specified and directed by Engr-in-Charge.
Material and Labour for point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by Eng-in-charge, with PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire, ISI marked of green colour for continuous earth, including sunken box made out of suitable thickness and not less than 60 mm in depth GI/MS/ pressed steel terminal box to be concealed in wall, duly painted including 3mm hylam /masonite sheet cover, for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer, complete all as specified and directed by Engr-in-Charge, for One light point or one fan point controlled by one switch. Note : Wiring to be done as per approved colour code.
-Ditto - all as per item No 61.00 here-in-before but One light point controlled by 2 way switch SP, 5 Amp, 240 Volts
-Ditto - all as per item No 61.00 here-in-before but one 5 amp socket point on same board
-Ditto - all as per item No 61.00 here-in-before but one 5 amp multi socket, independent
-Ditto - all as per item No 61.00 here-in-before but using 2.5 sqmm (nominal area) multistranded FRLSH copper conductor cable/wire & 2.5 sqmm size PVC insulated unsheathed copper conductor cable for earth continuity ( green colour) for one 5 pin socket outlet 5 / 15 Amp multi purpose independent point controlled by 15 Amp switch, SP one way, 240 Volts & Socket, complete all as specified and directed by Engr-in-Charge.
-Ditto - all as per item No 61.00 here-in-before but using 4 sqmm (nominal area) FRLSH multistranded copper conductor cable/wire for one 5/15 Amp socket point controlled by 15 Amp switch, SP one way 240 Volts & Socket, complete all as specified and directed by Engr-in-Charge.
Supply and fixing switch piano type flush button type single pole one way 5 Amps 240V front operated, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Switch socket combination 2 in 1 3 pin, 5 A and 15Amp flush type universal, complete all as specified and directed by Engr-in-Charge.
Supply and Fix socket 3 pin 5 A flush type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Bell buzzer 240V 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Bell push 240V 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix ceiling rose PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals, complete all as specified and directed by Engr-in-Charge.
Supply and Fix repair/replacement switch piano flush button single pole one way, 6 Amp (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Switch socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Switch bell push flush type 5 Amp (ISI marked) all as per complete all as specified and directed Engineer-in-Charge.
Supply and Fix in repair/replacement Switch socket combination outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Switch flush button, single pole two way, 6 Amp (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Socket type EME fan 5 step regulator switch/socket type for ceiling fan of suitable size, complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Lamp holder/angle holder insulated body with black/white plate for batten fittings, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping/ suitable size , ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly in surfaces/ recess complete including taking down all as specified and directed by Engr-in-Charge.
Material and Labour for cutting of wall/ceiling/column for laying submain of any size including plastering ,white wash, complete all as specified and directed by Engr-in-Charge.
Supply and fixing repair/replacement LED building security light fitting with suitable size bracket/angle with three core flexible wire to fit security light of 45 W, IP 66 protection LED, complete all as specified and directed by Engr-in-Charge.
Supply and fix repair/replacement LED batten with 20/22W LED tube light in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified by Engr-in-charge.
Supply and Fix double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 12 way double door open able, including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 8 way double door open able, including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB VTPN DB 4 Way made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 4 way ,including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB VTPN DB 8 Way made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 4 way ,including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement 6 to 32 AMP MCB single pole 240 V 10 KA (C-Series), complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement SPN 32 AMP ,240 V 10 KA (C-Series) , complete all as specified and directed by Engr-in-Charge.
Supply and fix LED Bulk head fittings 9/10W luminaire including LED light driver holder 220 V, AC,50HZ connecting up with three core flexible copper conductor cable of suitable size complete with all accessories complete all as specified and directed by Engr-in-charge.
Supply and Fix in repair/replacement LED tube rod 20/22 watt, 220V,AC, 50Hz change with existing any tube rod including flexible wire and connected accessories , complete all as specified and directed by Engr-in-Charge.
Supply and Fixix in repair/replacement Batten MS suitable for 18/22/24W LED rod 220V,AC, 50Hz with accessories including suitable 1.5 sqmm 2 core wire for connecting with ceiling rose, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement LED batten 10W, 2 feet with LED tube light 220V,AC,50HZ in wall/surface connecting with all required accessories like flexible cable from ceiling rose etc as directed and specified by Engr-in-charge.
Supply and Fix in repair/replacement MCCB 4 pole, thermal magnetic release range 100 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement MCCB 4 pole, thermal magnetic release range 125 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Material and Labour for daily complaint checking & repairing of DBs/meter panel board/circuits/submain wiring/switches/sockets etc and other connected work including rectification of faults , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement MCCB 4 pole, thermal magnetic release range 63 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement MCCB 4 pole, thermal magnetic release range 40 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement PCRD plug of capacity 15 amp , AC, 220V, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size approx 10x10cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size approx 15x7.5cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size approx 20x15cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size approx 20x25cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement emergency bulb LED 10W, 230V, 50Hz, with 2/4 hour backup, complete all as specified and directed by Engr-in-Charge.
Material and Labour for taking out and refixing of tube light, mirror light etc after cleaning and any type rectifying defect, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement LED batten with 20W LED tube light (four feet) with inverter type with 2 hrs backup in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified by Engr-in-charge.
Material and Labour for checking ceiling fan of size 1200/1400mm and change defective part quarter pin/ nut bolt , capacitor ,rewinding, bearing and minor items etc, complete all as specified and directed by Engr-in-Charge.
Material and Labour for earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanised iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point all as specified and indicated including testing on completion, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair GI strip 32mm x 6 mm saddle in wall for loop earthing and ground grid , complete all as specified and directed by Engr-in-Charge.
Supply and fix fan rod repair/replacement of size 1/1.5 feet suitable for mounting ceiling fan of size 1200/1400 mm, complete all as specified and directed by Engr-in-Charge.
Supply and fix repair/replacement flexible wire 1 sqmm x 2 core including taking out, complete all as specified and directed by Engr-in-Charge.
Supply & fixing, jointing, connecting & testing in saddle on wall 10 sqmm x 2 core, XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminium conductor in trenches / ducts/ of the following sizes including taking out cable cover & cable, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repairs/replacement air termination single pointed aluminium rod 12 mm dia and 300 mm long with necessary fixing arrangement on blocks on roof, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repairs/replacement air termination single pointed aluminium rod 12 mm dia and 1000 mm long with necessary fixing arrangement on blocks on roof, complete all as specified and directed by Engr-in-Charge.
Supply and Fix test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm thick drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws fixed to GI strip bracket fixed to porcelain insulator in wall as in repairs, complete all as specified and directed by Engr-in-Charge. Note :- Porcelain insulator will be measured & paid for separately.
Supply and Fix repair/replacement vitreous china porcelain insulator with busbar support white type, complete all as specified and directed by Engr-in-Charge.
Removing existing worn out CI cover with angle iron frame of earth chamber and supply and fix new CI cover of size 30 cm x 30 cm x 6 mm thick fixed in frame made out of mild steel angle iron 40 mm x 40 mm x 6 mm thick with and including locking and lifting arrangement, painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement 40 mm dia GI pipe medium grade for post not exceeding 3 metres in length truly vertical position embedded in PCC including not exc and earth work as in repairs, complete all as specified and directed by Engr-in-Charge. Note -: PCC of pole embedded will be measured and paid separately under relevant items of Sch.
Material and Labour for PCC (1:2: 4) type B0, using (12.5 mm graded stone aggregate) of blocks size and IE rules including necessary use and waste of form work as in grounting of porcelain insulator, complete all as specified and directed by Engr-in-Charge.
Material and Labour for PCC (1:2:4) type B1, using (20 mm graded stone aggregate) for earth chambers as in repairs, coping for GI pipe post including necessary form work, excavation in soft loose soil, returning in filling and removing surplus soil to a distance not exc 50 metre and deposing where directed, complete all as specified and directed by Engr-in-Charge.
Removing & refixing of air termination single pointed aluminium rod 12 mm dia and 300 mm long by tightening with necessary fixing arrangement fixed on existing/new PCC blocks on roof and making good complete all as specified and directed, complete all as specified and directed by Engr-in-Charge.
Material and Labour repair/replacement Submain wiring with two core 1100 volts 1.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including PVC conduit 20 mm dia with accessories like bend, junction box etc complete all as specified in and including 1.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuity conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement aluminium strip of size 25 x 3.15 mm fixed with suitable saddle, screw etc on roof with rubber & bitumen washer & fixed to insulator on wall for down conductor as fixed in repairs, complete all as specified and directed by Engr-in-Charge.
Re-fixing in repair only aluminium strip of size 20/25 mm x 3.15 mm fixed to porcelain insulator fixed with suitable saddle, screws etc for roof with rubber & bitumen washer & fixed to insulator only on wall for down conductor, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement two way sheet metal enclosure with three pin socket and plug top and 20 amp single pole MCB, complete all as specified and directed by Engr-in-Charge.
PART - I : (c) AC Works Supply and fix in repairs cooling tower fan Assembly with fan speed not exceeding 60m/s, out let air velocity not less than 610 m/min and noise level not exceeding 75 dBA made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades alongwith galvanised steel guard protection to protect fan and out side area suitable for 61 to 120 TR capacity AC plants, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs cooling tower fan Assembly with fan speed not exceeding 60m/s, out let air velocity not less than 610 m/min with noise level not exceeding 75 dBA made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades alongwith galvanised steel guard protection to protect fan and out side area suitable for upto 60 TR capacity AC plants, complete all as specified and directed by Engr-in-Charge.
Material and labour for taking out all old unserviceable PVC fills from cooling tower of capacity upto 100 TR and supply and fix in replacement of eliminator of cooling tower upto 100 TR, complete all as specified and directed by Engr-in-Charge.
Cleaning the cooling tower by applying wire brush, washing powder and other solvent by removing the deposited impurities such as silt, dust particles mud/ sand inside the dome and around the fins, cleaning of base tray & grills, pot strainer, main shaft etc and other connected items, servicing of fan motor including changing of bearings and greasing refixing the fan, frill & top cover including testing commissioning after reassembling complete including painting, complete all as specified and directed by Engr-in-Charge :-
(a) cooling tower of capacity upto 35 TR
(b) cooling tower of capacity 66 TR to 250 TR
Supply and fix in repairs Sprinkler Assembly complete with Header Nozzles made out of Galvanised iron suitable to fix in cooling towers of 61 TR and above Capacity AC plant, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs Sprinkler Assembly complete with Header Nozzles made out of Galvanised iron suitable to fix in cooling towers of upto 60 TR capacity AC plants, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Charging of refrigerant gas R- 407C / R134 / R22 in sealed cylinder after making system leak proof , complete all as specified and directed by Engr-in-Charge Note:-Refrigerant shall be issued to contractor for each AC plant from AGE E/M -II store yard. Transportation as well as loading/unloading of cylinder from AGE E/M store yard to AC plant will be the responsibility of the contractor.
Supply and fixing of filter drier for chiller as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Supply and Fix of supply / return / exhaust air grilles /of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core complete all as specified and directed by Engr-in-Charge.
Complete Servicing of AHUs installed in Zone-01 AC plants, removing of air filters and refixing after cleaning with air blower and water with suitable cleaning agent , cleaning of cooling coil with wire brush ,air blower and water spraying pump with gun and mixing the chemical suitable for removing of scales on aluminium fins and straighten the fins of cooling coil by using suitable brush for capacity upto 10000 CFM, complete all as specified and directed by Engr-in-Charge.
Complete Servicing of AHUs installed in Zone-01 AC plants, removing of air filters and refixing after cleaning with air blower and water with suitable cleaning agent , cleaning of cooling coil with wire brush ,air blower and water spraying pump with gun and mixing the chemical suitable for removing of scales on aluminium fins and straighten the fins of cooling coil by using suitable brush for capacity10000 CFM to 20000CFM , complete all as specified and directed by Engr-in-Charge.
Material and Labour for repairs to condenser of AC plant by blocking the damaged/corroded tubes, complete all as specified and directed by Engr-in-Charge with the following instructions :- (i) Disconnecting the side covers of the condenser from their existing positions. (ii) Leakage testing of the condenser using pressurised nitrogen gas and finding the leaked tubes. (iii) Blocking the damaged/leaked tubes by brass plugs. (iv) Re-fixing the side covers of the condenser and the condenser valves from their existing positions with new nuts, bolts, rubber gasket and washers etc and painting the surface with approved shade of synthetic enamel paints for following capacities of condenser :-
(a) up to 35 TR Capacity
(b) 35TR and above capacity
Supply and fix regenerable coarse type, dust proof AHU air filter, complete all as specified and directed by Engr-in-Charge for following sizes:-
(a) AHU air filter of size 60cm x 60 cm x5 cm
(b) AHU air filter of size 60cm x 50 cm x 5 cm
(c) AHU air filter of size 60cm x 40 cm x 5 cm
(d) AHU air filter of size 60cm x 30 cm x 5 cm
Dismantling and removing old unserviceable compressor sealed unit of Scroll Type Compressor carefully and supply, installation, testing new sealed Compressor unit of capacity 12.5 TR Model No SZ185S4RC of Make Blue Star/ Danfoss or equivalent complete with all standard accessories as per existing model installed at AC plant, complete all as specified and directed by Engr-in-Charge. Notes:- (i) Sealed unit shall be purchased from authorised dealers/agents (ii) Cost of labour for fixing and testing of leakage alongwith initial charging of suitable refrigerant & T&P shall be deemed to include in the quoted rate of this item. (iii) Unit rate quoted shall include for the necessary electrical check i.e. checking of panel wiring to run the compressor smoothly. (iv) Before opening/ dismantling of unserviceable compressor the refrigerant to be taken in empty cylinder as directed by Engr-in-Charge.
Dismantling and taking down defective parts of chiller/condenser pump set of capacity 7.5 to10HP,replacement of defective parts like-bearing, bushes, impeller and shaft including lathe work and reassembling complete set including connecting and testing in presence of MES rep with entire satisfaction of Engr-in-Charge. Notes:- (i) bearing, bushes and impeller and shaft shall be measured and paid separately (ii) Quoted rates are also deemed to be included for replacement of gaskets, packing with bearing grease, glands with graphite packing , nuts bolts , washers etc. (iii) Cost of transportation shall be deemed to be included in the rate quoted for these items. (iv) While taking out pump for repairs , the contractor will make arrangement plugging suction and discharge line with dead flanges, so that pumping of installation is not disturbed and there is no leakage of water.
Supply only in replacement the following spare parts for servicing and repairs of pump set under item No 141.00 here in before, complete all as specified and directed by Engr-in-Charge :-
Ball bearing suitable for 7.5 HP pump set
Ball bearing suitable for 10 HP pump set
Bronze impeller suitable for 7.5 HP pump set.
Bronze impeller suitable for 10 HP pump set.
Bronze bush suitable for 7.5 HP pump set
Bronze bush suitable for 10 HP pump set
Bronze shaft suitable for 7.5 HP pump set
Bronze shaft suitable for 10 HP pump set
Dismantling and taking down defective parts of chiller/condenser pump set of capacity 3 to 5HP, replacement of defective parts like-bearing, bushes, impeller and shaft including lathe work and reassembling complete set including connecting and testing in presence of MES rep with entire satisfaction of Engr-in-Charge. Notes:- (i) bearing, bushes and impeller and shaft shall be measured and paid separately (ii) Quoted rates are also deemed to be included for replacement of gaskets, packing with bearing grease, glands with graphite packing , nuts bolts, washers etc. (iii) Cost of transportation shall be deemed to be included in the rate quoted for these items. (iv) While taking out pump for repairs , the contractor will make arrangement plugging suction and discharge line with dead flanges, so that pumping of installation is not disturbed and there is no leakage of water.
Supply only in replacement the following spare parts for servicing and repairs of pump set under item No 143.00 here in before, complete all as specified and directed by Engr-in-Charge.
Ball bearing suitable for 3 HP pump set
Ball bearing suitable for 5 HP pump set
Bronze impeller suitable for 3 HP pump set.
Bronze impeller suitable for 5 HP pump set.
Bronze bush suitable for 3 HP pump set
Bronze bush suitable for 5 HP pump set
Bronze shaft suitable for 3 HP pump set
Bronze shaft suitable for 5 HP pump set
Material and Labour for painting of motor & pump for removing the existing deteriorated paint by scrapping the complete body along with complete foundation of Pump and Motor and filling the cavities with filter spray painting with Anti corrosive paint, two coats over a coat of red oxide zinc chrome and marking of SM/MES No. with black/white paint for the following :-
(a) Capacity 7.5 HP and above
(b) Capacity below 7.5 HP
Material and Labour for rewinding of induction motor 900RPM, 3 phase, 50 Hz, 415 volt of compressor motor and AHU Blower , chiller , condenser motor comprising of the following activities for induction motor of following capacities complete all as specified and directed as per manufacturer's instructions. :- Notes :- (i) Any adjustment in the pump set if required, the same shall also be carried out by the contractor without any extra payment. (ii) Any damage to the pump set occurs due to improper installation of motor, contractor shall be liable for repair.
(a) Capacity 20 HP and above
(b) Capacity 15 HP
(d) Capacity 10 HP.
(e) Capacity 7.5 HP.
(f) Capacity 5 HP.
(g) Capacity upto 1 to 3 HP.
Dismantling electrically and mechanically electric motor any size, dismantling part, taking out unserviceable bearing capacity upto 15 HP including supply and replacement of new bearing, reassembling, reinstallation and testing complete all as specified and directed by Engr-in- Charge.
Dismantling electrically and mechanically electric motor of any size of AHU , taking out unserviceable Parts like-shaft, Impeller, bushes, fan blade, coupling and fan belt, replacement with new one, reassembling, reinstallation and testing the following size all as directed by Engr-in- Charge.
Supply only in replacement the following spare parts for servicing and repairs of AHU unit under item No 148.00 here in before, complete all as specified and directed by Engr-in-Charge :-
Bronze shaft suitable upto 60 TR AHU Unit
Fan belt suitable as per existing
Supply and Fix gland packing in 10/12.5 HP pump set, complete all as specified and directed by Engr-in-Charge.
Supply and Fix gland packing in 5/7.5 HP pump set, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 4.5 to 7.5 Amp with single phasing protection including taking down old unserviceable relay, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 9 to 15 Amp with single phasing protection including taking down old unserviceable relay, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 14 to 23 Amp with single phasing protection including taking down old unserviceable relay, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement electronic timer 800SQA of working voltage 240V 50 Hz including taking down old unserviceable timer, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement Air break contactor Model No 3TS3500-0A with Auxiliary 3TX400--2A 1 NC 415 V, 50 Hz, AC including taking down old unserviceable contactor, complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCB SP 6 to 32 amp rating 240V, 10KA 'C' curve including taking down old unserviceable MCB, complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCB TP 40 to 63 AMP 415V 10KA 'C' curve including taking down old unserviceable MCB, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA including taking down old unserviceable MCCB , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB 3 Pole, 415 V, fixed type, 25 to 400 Amps with breaking capacity 36 KA including taking down old unserviceable MCCB, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB 4 Pole, 415 V, Adjustable type, 160Amps with breaking capacity 36 KA including taking down old unserviceable MCCB, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB 4 Pole, 415 V, Adjustable type, 400Amps with breaking capacity 36 KA including taking down old unserviceable MCCB, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement power contactor 3 pole, type MNX 12, 1NO + 1 NC aux contracts with standard coil voltage 240 volts, raring 30 Amp of equivalent contactor of other makes as per site requirement in bluestar and voltas AC plants including taking down old unserviceable contactor , complete all as specified and directed by Engr-in-Charge. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, type MNX 18, 1NO + 1 NC aux contracts with standard coil voltage 240 volts, raring 30 Amp of equivalent contactor of other makes as per site requirement in bluestar and voltas AC plants including taking down old unserviceable contactor, complete all as specified and directed by Engr-in-Charge. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, type MNX 22 or 25 , 1NO + 1 NC aux contracts with standard coil voltage 240 volts, raring 30 Amp of equivalent contactor of other makes as per site requirement in bluestar and voltas AC plants including taking down old unserviceable contactor, complete all as specified and directed by Engr-in-Charge. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, type MNX 32 , 1NO + 1 NC aux contracts with standard coil voltage 240 volts, raring 30 Amp of equivalent contactor of other makes as per site requirement in bluestar and voltas AC plants including taking down old unserviceable contactor, complete all as specified and directed by Engr-in-Charge. (Make should be as per existing item)
Supply, assembly and erection including taking down and repair of GI sheet with C & SS rectangular/square duct made out of L shaped hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joint etc complete of size 24 gauge, complete all as specified and directed by Engr-in-Charge.
Material and Labour in repair for duct insulation including taking down resin bonded fibre glass wool roll of density 24 Kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation 50 mm, complete all as specified and directed by Engr-in-Charge including the following :- (a) Material and Labour for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of mill scale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) Material and Labour for applying rubber based adhesive CPRX compound. (c) Material and Labour for sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50 mm wide, to make the insulation leak proof. (d) Material and Labour for securing the insulation with and including mechanically fastened nylon / steel straps of size 12 mm / 50 mm at maximum intervals of 1.2 metre.
Material and Labour in repair for duct insulation with resin bonded fibre glass wool roll of density 24 Kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation 40 mm, complete all as specified and directed by Engr-in-Charge including the following :- (a) Material and Labour for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of mill scale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) Material and Labour for applying rubber based adhesive CPRX compound. (c) Material and Labour for sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 40 mm wide, to make the insulation leak proof. (d) Material and Labour for securing the insulation with and including mechanically fastened nylon / steel straps of size 12 mm / 40 mm at maximum intervals of 1.2 metre.
Supply and fix in repairs Auto capacity regulator solenoid valve of Make : Rotex, 220V, 50Z or equivalent in Avcon, Accel cat part No 50 including connecting of interlock wiring, nut, bolt, washer etc including taking down old unserviceable solenoid valve all as specified and directed by Engr-in-charge
Supply and fix in repairs Coil for solenoid valve SP-180 cat part No 50-A of Make : Accel, Sporlan, Rotex connecting into liquid line including interlock wiring, nut, bolt , washer etc including taking down old unserviceable solenoid valve all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of thermostatic expansion valve of suitable capacity HVE size for keep a constant superheat or refrigerant level situation in refrigeration system based on evaporator outlet temperature and pressure suitable for DX type AC plant including taking down old unserviceable expansion valve. After fixing testing should be entire satisfaction of Engr-in-charge.
Supply and fix in replacement of thermostatic expansion valve of suitable capacity MVE size suitable for scroll type chiller units for keep a constant superheat or refrigerant level situation in refrigeration system based on evaporator outlet temperature and pressure. Brazing of the expansion valve is in the scope of the contractor in this item including taking down old unserviceable expansion valve all as per entire satisfaction of Engr-in-charge.
Material and Labour for descaling of complete condenser unit of AC plant up to 60 TR Quarterly for central/ package type AC plants of following capacities by means of adding descaling chemical solution (HCL) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and re fixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc, complete all as specified and directed by Engr-in-Charge
Supply and Fix in repairs of Motor and Voltage protective device MVPD 5-30 A as per existing make and type, complete all as specified and directed by Engr-in-Charge.
Supply and fix Microprocessor Scroll Controller for compressor of 12.5-40 TR Capacity including removing unserviceable of Microprocessor , complete all as specified and directed by Engr-in-Charge. The Microprocessor should be as per the existing one and installed by the company authorised person duly calibrated and necessary wiring work also included in the quoted rate to the satisfaction of Engr-in-charge.
Supply and fix Microprocessor suitable for DX type compressor upto 78 TR Capacity including removing unserviceable of Microprocessor complete all as specified and directed. The Microprocessor should be as per the existing one and installed by the company authorised person duly calibrated and necessary wiring work also included in the quoted rate to the satisfaction of Engr-in-charge.
Supply and fix in replacement of Single phase preventer type SPP VSP3 3 phase, 415 Volts, 50 Hz AC, including taking down old unserviceable preventer, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of CVT for chiller controller power supply 3 phase, 415 Volts, 50 Hz AC including taking down old unserviceable chiller controller , complete all as specified and directed by Engr-in-Charge.
Supply and fixing of connector in HVAC panel 6 Amp to 35 Amp including taking down old unserviceable connector , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MS ERW tubing medium grade 80mm dia for condenser water circulation pipes, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MS ERW tubing medium grade 100mm dia for condenser water circulation pipes, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Nitrogen leak test entire system of the AC plant of Cap upto 150 TR with Nitrogen gas. If found any leakage or reduction in the scale of pressure shall located and arrest the leakage immediately by soldering or an appropriate measure to be taken to stop the leakage permanently complete all as specified & directed by Engr-in-Charge.
Supply and Fix in replacement of butter fly valve of 65 mm dia, cast iron body, integrally molded close and body construction with hand lever, operated and rating of PN 10 with thermal insulation as per requirement of condenser and chilled water line complete including taking down old unserviceable valve, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of butter fly valve of 80 mm dia, cast iron body, integrally molded close and body construction with hand lever, operated and rating of PN 10 with thermal insulation as per requirement of condenser and chilled water line complete including taking down old unserviceable valve, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of butter fly valve of 100 mm dia, cast iron body, integrally molded close and body construction with hand lever, operated and rating of PN 10 with thermal insulation as per requirement of condenser and chilled water line complete including taking down old unserviceable valve, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of gun metal gate or globe valve of 15 mm dia with iron wheel head screwed both ends for iron pipes complete including taking down old unserviceable valve, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of gun metal gate or globe valve of 25 mm dia with iron wheel head screwed both ends for iron pipes complete including taking down old unserviceable valve, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of 15 mm dia ball brass valve , high pressure, with polythene float and fly nuts complete, screw for iron pipe or brass ferrule and mixed complete including taking down old unserviceable valve, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of 25 mm dia ball brass valve , high pressure, with polythene float and fly nuts complete, screw for iron pipe or brass ferrule and mixed complete including taking down old unserviceable valve , complete all as specified and directed by Engr-in-Charge.
Supply and Fix and replacing in repairs of Chilled water sensor as per existing make and type , complete all as specified and directed by Engr-in-Charge.
Supply and Fix and replacing in repairs of pressure transducer sensor for LP and HP of the compressor unit as per existing make and type, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of flow switch as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Material and Labour and replacing in repairs Strip heater finned 2 inch wide aluminised steel fins of 415 volt 1.5 to 3 KW capacity to match with the existing, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs pressure gauge of range -30-150 including taking down old unserviceable pressure gauge, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs pressure gauge of range 0-150 including taking down old unserviceable pressure gauge, complete all as specified and directed by Engr-in-Charge.
Supply and fix and replacement in repairs in repair on-off push button pendants with elements red/green/orange, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement V Belt of Make : Nirlon, Fenner, Ecodrive or equivalent, all as specified and directed by Engr-in-Charge of following sizes :-
(a) V Belt A-33
(b) V Belt A-28
(c) V Belt A-48
(d) V Belt A-79
(e) V Belt A-62
Dismantling/Taking down old unserviceable FRP body structure of cooling tower carefully and cleaning the sump with chemical and supply and fixing of new FRP sheets as per size existing at site including all fixing material such as m seal other water resistance adhesive and making the cooling tower structure leak proof , complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable insulation over the chiller pipe line, cleaning water pipe surface with steel brush removing dirt/dust, Material and labour for chilled pipe line insulation by applying a coat of zinc chromate primer & applying two coats of cold setting adhesive compound (CRPX) on pipes for sticking the insulation bonded mineral wool of density 144 Kg/cum, 50mm thickness tightly pressed on the pipe upto 250mm dia seal all the joint with adhesive compound warp the insulation surface by using one layer of polythene sheet 50mm wide PVC tape covering the entire surface with chicken mesh , of density 144 Kg/Cum and cover 26 gauge aluminium GI cladding of approved colour & cover with Glasswool complete all as specified and directed by Engineer-in-Charge.
Supply and fix and replacing protection caps made out of GI Sheet of thickness 1.6 mm with three GI strip supports of size 25x3mm for fixing with the Cooling Tower including GI nuts & bolts for fixing, complete all as specified and directed by Engr-in-Charge.
Material and Labour for earthing complete with copper earth plate electrode of 60 cm x 60 cm x 3.15 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to copper strip of size 20 mm x 3 mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 40 mm diameter, connected to earthing test point, all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. complete as specified and directed by the Enngr-in-Charge. Notes: (i) The cost of earth continuity conductor with GI pipe 40mm medium grade upto 7.5m is deemed to be included in r/o above item (ii) The earth resistance value should not be more than 2 Ohm. (iii) Earth test report shall be submitted by contractor. If the earth resistance value is more than 2 Ohm new earthing will be done by contractor as replacement and no payment shall be mate for it. (iv) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item and including taking down old unserviceable earthing complete all as specified and directed by Engr-in-Charge.
Material and Labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3 mm copper strip complete including taking down old unserviceable earth leads all as specified and directed by the Engr-in-Charge.
Supply, fixing and replacement of canvas housing suitable for existing connection AHU damper to Supply air Duct, complete all as specified and directed by Engr-in-Charge.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in repairs of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required, all as specified and directed by Engr-in-Charge.
Material and labour for overhauling of compressors SMC 4-65 Make compressor complete all as per manufacturer's instruction by authorised dealers / workshop for improved performance and designed parameter including the following , complete all as specified and directed by Engr-in-Charge :- (i) Replacement of crank shaft of suitable size including dismantling transporting to authorised approved work shop and back including refixing after repair and testing. (ii) Complete dismantling of each part of compressors cleaning each part of compressors carrying out preventive work like oiling, greasing, replacing defective parts reassembling compressors complete with vacuum test and pressure test at specified pressure to detect leak and again same tests after leak repair to ensure leakage in the complete system. Notes :- (a) New spare parts of compressors as required shall be measured and paid separately as supply only and cost of labour and T&P shall be deemed to include in the quoted rate of this item. (b) Unit rate quoted shall include for the necessary electrical check i.e. checking of panel wiring to run the compressor smoothly. (c) Before opening of compressor the Freon gas to be taken in empty cylinder by the help of ice or as directed by Engr-in-charge. (d) Unit rate quoted shall also be included for testing the whole system for any leakage using nitrogen gas by vaccumising the system and filling the system with pressurised nitrogen to test the leakage including nitrogen gas as required and top up repaired compressor and whole system with refrigerant gas R-22 and compressor oil after confirmation of no leakage. (e) Unit rate quoted shall also be inclusive of charging of compressor oil and refrigerant of sufficient quantity or as directed by Engr-in-charge. (f) Minor items required for smooth functioning of compressor is included in the quoted rate of the item. Location DBM-16
Supply only following parts of make SMC 4-65 model Accel compressor , complete all as specified and directed by Engr-in-Charge :-
Bushing with collar
Half section of bearing
Rocker for unloading mechanism
Connecting rod assembly
Shaft seal assembly including 10 AG
Bushing for piston pin
Piston with pin and Rings
Cylinder liner with suction valve assembly
Oil pressure valve
Compressor safety valve
Suction valve ring plate
Suction valve retaining plate
Discharge valve ring
Discharge valve retaining plate
Suction strainer for SMC 4-65
Oil strainer and filter
Castle Nuts
Split pins
Scraper Ring
Seeger Ring
Cup washer
Crank shaft for SMC 4-65
Set of gasket for SMC 4-65
Set of neoprene 'O' ring SMC 4-65
Sealing ring set SMC 4-65
Dowty ring set SMC 4-65
Set of aluminium gasket SMC 4-65
Suction stop valve assembly
Discharge stop valve assembly
Material and labour for overhauling of compressors model No 5H66 (Voltas) Make compressor complete all as per manufacturer's instruction by authorised dealers /workshop for improved performance and designed parameter including the following , complete all as specified and directed by Engr-in-Charge :- (i) Replacement of crank shaft of suitable size including dismantling transporting to authorised approved work shop and back including refixing after repair and testing. (ii) Complete dismantling of each part of compressors cleaning each part of compressors carrying out preventive work like oiling, greasing, replacing defective parts reassembling compressors complete with vacuum test and pressure test at specified pressure to detect leak and again same tests after leak repair to ensure leakage in the complete system. Notes : (a) New spare parts of compressors as required shall be measured and paid separately as supply only and cost of labour and T&P shall be deemed to include in the quoted rate of this item. (b) Unit rate quoted shall include for the necessary electrical check i.e. checking of panel wiring to run the compressor smoothly. (c) Before opening of compressor the Freon gas to be taken in empty cylinder by the help of ice or as directed by Engr-in-charge. (d) Unit rate quoted shall also be included for testing the whole system for any leakage using nitrogen gas by vaccumising the system and filling the system with pressurised nitrogen to test the leakage including nitrogen gas as required and top up repaired compressor and whole system with refrigerant gas R-22 and compressor oil after confirmation of no leakage. (e) Unit rate quoted shall also be inclusive of charging of compressor oil and refrigerant of sufficient quantity or as directed by Engr-in-charge. (f) Minor items required for smooth functioning of compressor is included in the quoted rate of the item. Location A224S Plant
Supply only following parts of make Voltas model 5H66 compressor, complete all as specified and directed by Engr-in-Charge :-
Bushing with collar
Half section of bearing
Rocker for unloading mechanism
Connecting rod assembly
Shaft seal assembly including 10 AG
Bushing for piston pin
Piston with pin and Rings
Cylinder liner with suction valve assembly
Oil pressure valve
Compressor safety valve
Suction valve ring plate
Suction valve retaining plate
Discharge valve ring
Discharge valve retaining plate
Suction strainer for SMC 4-65
Oil strainer and filter
Castle Nuts
Split pins
Scraper Ring
Seeger Ring
Cup washer
Crank shaft for SMC 4-65
Set of gasket for SMC 4-65
Set of neoprene 'O' ring SMC 4-65
Sealing ring set SMC 4-65
Dowty ring set SMC 4-65
Set of aluminium gasket SMC 4-65
Suction stop valve assembly
Discharge stop valve assembly
Supply and fix in replacement of wall mounting /hanging type LED digital type temperature /relative humidity indicator with 2" large size display and minimum size (445x130x115mm) with following specifications , complete all as specified and directed by Engr-in-Charge. Display : 2" Red LED x 2 Display, Accuracy : + 0.5%, Resolution : 0.1 deg C, 0.1 % RH, Input : 4-20mA, Enclosure : Powder coated metal case. Operating Voltage : 230V AC.
Material and labour for laying, jointing, connecting and testing in repairs sensor cable 3 core 2.5 sqmm PVC insulated and sheathed with bare annealed copper conductor as per IS 694:1990 for connecting RH+T sensor to RH+T indicators , complete all as specified and directed by Engr-in-Charge.
Material and labour for laying, jointing, connecting and testing in repairs indicator cable 2 core 1.5 sqmm PVC insulated and sheathed with bare annealed copper conductor complete including taking down old unserviceable cable all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of Thermal Insulation of Ducts with Nitrile Rubber, 25 mm thick with aluminium cladding including taking down old unserviceable insulation, all as specified and as directed by Engr-in-charge. Density of Material shall be between 40 to 60 Kg/m3. Material shall have flammability class V-0 as per UL 94 and shall be FM Approved.
Material and Labour for replacement of unserviceable pot strainer 80/100mm including replacement of unserviceable rusted nut bolts, washers, & gasket , complete all as specified and directed by Engr-in-Charge
Material and Labour for spray painting to Central AC Plant complete comprising of compressors, motors, condensor, cooling tower and cooling tower pumps, pump / monoblocks, MS / GI pipe lines of sizes etc after preparation of old painted surface as per colour code including and marking arrow, SM/ MES Nos, colour for 15 to 170 TR ACs plant as directed by the Engr-in- charge.
Supply and Fix of Drift eliminator of cooling tower having capacity of 20TR to 85TR as per existing at site including taking down old unserviceable drift , complete all as specified and directed by Engr-in-Charge
Supply and Fix of Drift eliminator of cooling tower having capacity of 85TR and above as per existing at site including taking down old unserviceable drift , complete all as specified and directed by Engr-in-Charge
POWER CABLES - Material and Labour for ISI marked 1.1 kV grade aluminium conductor, XLPE insulated armoured cables, conforming to IS: 7098 (Part 1)- 1988 having stranded aluminium compact shaped conductor as per Cl. 2, IS: 8130- 1984, PVC inner sheath, single armouring of galvanized steel strip/wire and PVC Type ST2 outer sheath conforming to IS: 5831- 1984, including termination and taking down old unserviceable cable , complete all as specified and directed by Engr-in-Charge :-
(a) 3.5 core, 95 mm² (for AHU and AHU )
(b) 4 core, 10 mm² (for pumps)
(c ) 3 core, 10 mm² (for Cooling Tower)
(d) 2 core, 1.5 mm² ( for chillers interlocking)
Taking down and dismantling existing street Light/ Flood Light / post lantern / tube light fittings any type any wattage for repair or replacement of burnt /worn out accessories and refixed in position after repair , complete all as specified and directed by Engr-in-Charge Notes :- (i) Accessories only wherever required shall be measured and paid separately as supply only. (ii) Labour charges for taking down and repair including minor spares like nuts, bolts , insulation materials & cleaning of area upto one metre around the street light/ building lights/ Poles shall be deemed to be included in the rate .
Supply and fixing Pressure die cast aluminium housing LED street light luminaires with IP66 of 35/45/50 Watts, complete all as specified and directed by Engr-in-Charge
Supply and fixing Pressure die cast aluminium housing LED street light luminaires with IP66 of 90 Watts , complete all as specified and directed by Engr-in-Charge
Supply and fixing Pressure die cast aluminium housing LED street light luminaires with IP66 of 120 Watts , complete all as specified and directed by Engr-in-Charge
Supply and Fix LED floodlight luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66, Turbo LED series ,120 Watt & accessories and connecting up to looping box with PVC insulated multi stranded copper conductor cable 1.5 sqmm twin Core , complete all as specified and directed by Engr-in-Charge
Supply & Fix in repair bracket for street light fittings made out of 40 mm bore medium grade GI tubing 1.2 m long bent to shape and including suitable size of MS clamps, nuts, bolts and washers applying two coats of aluminium paint over a coat of red oxide zinc chrome primer repair, complete all as specified and directed by Engr-in-Charge
Supply and fix for PVC two mounting layered, closed lid cylindrical shapes ISI marked water tank of 5000 litres capacity mounted on existing suitable stage including taking down old unserviceable tank , complete all as specified and directed by Engr-in-Charge. Note :- In case some parts required extensive repair and replacement , the same shall be done by contractor. Rates deemed to be included in quoted rate.
Supply and fix for PVC two mounting layered, closed lid cylindrical shapes ISI marked water tank of 10000 litres capacity mounted on existing suitable stage including taking down old unserviceable tank , complete all as specified and directed by Engr-in-Charge. Note :- In case some parts required extensive repair and replacement , the same shall be done by contractor. Rates deemed to be included in quoted rate.
Supply and Fix in repairs steel water tubing galvanised iron 100mm dia medium grade with all fittings ISI marked including taking down old unserviceable GI pipe all as specified and directed by Engr-in-Charge.
-Ditto- all as per item No 229.00 here-in-before but 80 mm dia
-Ditto- all as per item No 229.00 here-in-before but 40 mm dia
-Ditto- all as per item No 229.00 here-in-before but 25 mm dia
Supply and Fix in repairs steel water tubing galvanised iron 40mm dia light grade with all fittings ISI marked including taking down old unserviceable GI pipe all as specified and directed by Engr-in-Charge. (item used for earthing only)
Supply only Rotational moulded polyethylene water storage tanks 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position including taking down old unserviceable tank all as specified and directed by Engr-in-Charge.
Supply and fix in replacement power contactor 3 pole, type 1 NO/NC (Normal open/Normal Close) 65 Amps with standard coil voltage 415 volts, Chint's NC-1 6511 contactor of bluestar and voltas AC plants compressor unit of make M/s Chint's including taking down old unserviceable contactor, complete all as specified and directed by Engr-in-Charge. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, 25 Amps Power contactor Lc1D25M7 for condenser/ chiller motor of bluestar and voltas AC plants unit of make M/s Schneider including taking down old unserviceable contactor ,complete all as specified and directed by Engr-in-Charge. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, 18 Amps Power contactor Lc1D18M7 for CT fan motor of bluestar and voltas AC plants unit of make M/s Schneider including taking down old unserviceable contactor, complete all as specified and directed by Engr-in-Charge. (Make should be as per existing item)
Supply and Fix in replacement of Non return single plate check valve is designed for return flow prevention in pipeline installation of size 100 mm dia, cast iron body for water delivery line complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of Non return single plate check valve is designed for return flow prevention in pipeline installation of size 80 mm dia, cast iron body for water delivery line complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of Non return single plate check valve is designed for return flow prevention in pipeline installation of size 63 mm dia, cast iron body for water delivery line complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement Thermal overload relay type LRD 08 relay range, 4.00 to 7.50 Amp with single phasing protection , all as specified and directed by Engr-in-Charge
FRP INDUCED DRAUGHT COOLING TOWER - Supply, installation, testing and commissioning of Twin Cell FRP rectangular shape, vertical, induced draught top discharge counter flow cooling tower of 20 TR size with uniform water distribution and optimal heat transfer, having tough fibreglass reinforced plastic (FRP) casing of sufficient structural strength to withstand vibrations and wind velocity upto 60 m/s, FRP basin, rigid honeycomb type PVC fill of suitable thickness, SS sprinklers and non-clogging sprinkler pipes, FRP drift eliminator, energy efficient induced draught axial type fans with factory set and dynamically balanced blades pitch, IE3 TEFC squirrel cage induction motor, suitable for operation on 3- Ph, 415 V, 50 Hz AC supply with IP 65 protection for enclosure, conforming to IS 12615: 2018, inlet, outlet, drain and over-flow nozzle connections, etc. complete with accessories as specified and directed by the Engineer-in-charge. Note : Necessary civil work viz. foundation, supporting structure, etc. for placement of cooling tower shall be deemed to be included in the scope of work. Location : AGM-13, SBM-14
FRP INDUCED DRAUGHT COOLING TOWER - Supply, installation, testing and commissioning of Twin Cell FRP rectangular shape, vertical, induced draught top discharge counter flow cooling tower of 80 TR size with uniform water distribution and optimal heat transfer, having tough fibreglass reinforced plastic (FRP) casing of sufficient structural strength to withstand vibrations and wind velocity upto 60 m/s, FRP basin, rigid honeycomb type PVC fill of suitable thickness, SS sprinklers and non-clogging sprinkler pipes, FRP drift eliminator, energy efficient induced draught axial type fans with factory set and dynamically balanced blades pitch, IE3 TEFC squirrel cage induction motor, suitable for operation on 3- Ph, 415 V, 50 Hz AC supply with IP 65 protection for enclosure, conforming to IS 12615: 2018, inlet, outlet, drain and over-flow nozzle connections, etc. complete with accessories as specified and directed by the Engineer-in-charge. Note :- Necessary civil work viz. foundation, supporting structure, etc. for placement of cooling tower shall be deemed to be included in the scope of work. Location : A224S
Supply and fix perforated mild steel galvanised cable tray size 150x50x1.2 for proper layout of cable with proper fixing arrangement, all as specified & directed by Engr-in-Charge.
Supply and fix perforated mild steel galvanised cable tray size 200x50x1.2 for proper layout of cable with proper fixing arrangement, all as specified & directed by Engr-in-Charge.
Supply and fix perforated mild steel galvanised cable tray size 300x50x1.2 for proper layout of cable with proper fixing arrangement, all as specified & directed by Engr-in-Charge.
PART - II : (a) Manning & Operation Out sourcing of services for Manning and operation of central AC plants by one skilled ref mech operator in each shift of 08 hrs i.e. Three (03) in a day for shifts i.e. 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, 2200 Hrs to 0600 Hrs including Sunday & Holiday. The documentation of plant to be done by Ref Mech including maintaining Log Book. Routine maintenance including upkeep and cleanliness of other equipment like pump/motors, Cooling tower, AHU and surrounding area will be done by Ref Mech. The following AC plant equipments, accessories and control panel will be maintained as specified and as directed by Engr-in-charge. (a) DX type central AC plant make Voltas of capacity 34 TR (02 working + 01 stand by) installed at DBM 16 for maintaining Temp 21°C + 2°C and humidity 55 + 5% (b) Chilled water type central AC plant make Blue star of capacity 52 TR (02 working + 01 stand by) installed at DBM 19 for maintaining Temp 22°C + 2°C and humidity 60 + 5%
Out sourcing of services for Manning and operation of central AC plants by one skilled ref mech operator in each shift of 08 hrs i.e. Three (03) in a day for shifts i.e. 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, 2200 Hrs to 0600 Hrs including Sunday & Holiday. The documentation of plant to be done by Ref Mech including maintaining Log Book. Routine maintenance including upkeep and cleanliness of other equipment like pump/motors, Cooling tower, AHU and surrounding area will be done by Ref Mech. The following AC plant equipments, accessories and control panel will be maintained as specified and as directed by Engr-in-charge. (a) Chilled water type central AC plant make Blue star of capacity 52 TR (02 working + 01 stand by) installed at DBM 18 for maintaining Temp 22°C + 2°C and humidity 60 + 5%
Out sourcing of services for Manning and operation of central AC plants by one skilled ref mech operator in each shift of 08 hrs i.e. Three (03) in a day for shifts i.e. 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, 2200 Hrs to 0600 Hrs including Sunday & Holiday. The documentation of plant to be done by Ref Mech including maintaining Log Book. Routine maintenance including upkeep and cleanliness of other equipment like pump/motors, Cooling tower, AHU and surrounding area will be done by Ref Mech. The following AC plant equipments, accessories and control panel will be maintained as specified and as directed by Engr-in-charge. (a) Chilled water type central AC plant make Blue star of capacity 26 TR (02 working + 01 stand by) installed at AGM-13/ SBM-14 for maintaining Temp 23°C + 2°C and humidity 65 + 5%.
General notes for Item No 247.00 to 249.00 (a) Rate quoted by tenderer for the above items shall be deemed to be included for the expenditure of keeping general cleanliness of the area of the installations complete including cutting of grass shrubs & vegetations around the installations. (b) Protective clothing as per IS and safety instructions & tools required as applicable shall be provided by the contractor and shall be continuously in use of the operator on duty. No extra payment will be made to contractor for the same. (c) Printed log sheet shall be provided and maintained by the contractor properly as per the format approved by Eng-in-Charge duly signed by all concerned and no extra cost shall be admissible for this account. Log book shall be deposited with concerned JE every months and no payment will be made in absence of the same. (d) ITI qualified in Air Conditioning & Refrigeration or having minimum 5 years experience in operation and maintenance of Air Conditioning & Refrigeration plant shall be deployed by the contractor. Contractor shall arrange his man power in such a way that each employee should not be assigned more than one shift of 8 hours in a single day and weekly one day off is given to each employee for which separate manpower arrangement to be done by the contractor without any extra cost to the dept. (e) Any breakdown of AC Plant shall be reported immediately to JE E/M / Engr-in- Charge. (f) Life insurance of employed person shall be carried out by the contractor at his own cost from any insurance company approved by IRDA. (g) Contractor will provide the uniform as recommended by Engr -in-Charge. The safety of equipment necessary T & P shall be maintained at all the installations. The contractor shall be fully responsible for safety of staff employed. Department will not be held responsible for any eventuality occurred to staff employed. The contractor will be responsible / liable to pay all type of compensation etc to employed staff in accordance with prevailing labour laws in country/ staff. (h) The tradesmen shall be well conversant with preventive measures (First Aid) in case of electrical accidents and fire fighting systems.
(j) Carrying out operation of equipments, as a part of day to day operation and in accordance with relevant PM checklists and as per schedules that will be prepared upon activation of contract. The salient features in these checklists are as follows :- (i) Starting and stopping of the equipment as per requirement of the user. (ii) Checking the water level in the cooling tower (applicable for water cooled units) (iii) Recording the equipment operational parameter including pump pressure and motor amps in the log sheet. (iv) Checking the central AC or Refrigeration system and equipment such as compressors, motors, pumps, cooling towers and their electrical controls on the respective equipment. (v) Checking the refrigeration system for any leaks. (vi) Checking the electrical and refrigeration control system for operation and adjustments of set values as necessary. (k) Penalty of absence of any Ref Mech shall be Rs 2500/- per shift per day. (l) Tmp measurer shall be provided by contractor in respective installation in proper working condition. Rates quoted deemed to include the same.
Notes:- The quoted rate for above plants described at item No 247.00 to 249.00 here-in-before shall be deemed to be included the following:- (i) The operator shall be ITI holder with sufficient experience (not less than 05 years). The operator should be capable to rectify both mechanical as well as electrical defects for smooth functioning of AC plants. It is responsibility of contractor to provide a reliever to the operator. So that the operator is available all time. (ii) Man power list with aadhar linked bank account number, qualification certificate will be submitted prior to commencement of work for necessary sanction from GE. (iii) The contractor/ service providing agency shall be wholly and exclusively responsible for payment of wages of persons engaged by it in compliance with all the statutory obligations under all related legislations as applicable to it from time to time including Minimum Wages Act, ESI Act, EPF Act and the Department MES shall not incur any liability for any expenditure whatsoever on the persons employed by the contractor/ agency on account of any obligation. The contractor/ service providing agency will be required to provide particulars of group Insurance of employees engaged by him to the GE before processing of RAR payment. (iv) The contractor/ service providing agency will be required to provide two set of uniform to all operators with name and firm tag. (v) To carry out routine periodical checkups as directed by GE & Engr-in-Charge. (vi) Maintaining all the accessories such as electric panel, Interlocking wiring cables, pumps etc and all assemblies such as chillers etc and sub assemblies such as AHU, tower etc functional in any situation round the clock for the period including holidays etc. (vii) Maintaining the surrounding area of central AC plant building, cooling tower, etc neat & clean at all time. No wild vegetation to be seen with in the surrounding of building upto 5 metres all around (viii) Tools and plants such as spanners, wrench, screw driver, pliers, puller (Mechanically hydraulic) and alike items required for operation, sufficient running of the parts shall be arranged & are kept permanently with the staff (contractor's staff). However any major items which are required, as part of the installation shall arranged by the department.
Shree Ayyappa Engineering (BID ID -3382659)
BRITE INDUSTRIES (BID ID -3382315)
pk Enterprises (BID ID -3382322)
cooltech engineering services (BID ID -3382767)
Veer High Tech Solution (BID ID -3382904)
RADHA ENTERPRISE (BID ID -3383374)
DARSHAN CONSTRUCTION Co. (BID ID -3383697)
stage.html
html • 0.06 MB
tech_bid_open.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .