Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC H NO 1 BLOCK NO 2 SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹29.7 L+₹2.1 L (7.55%)Rejected-Finance | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder | |
| 3 | L3₹37.2 L+₹9.6 L (34.8%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Rejected being 3rd Lowest Bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Admitted as the firm have not uploaded EMD and documents for Provisional Enlistment | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Admitted as the firm is not enlisted in appropriate category |
Tender Value
Refer Docs
EMD Value
₹59,800
Closing Date
5 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMANDER WORKS ENGINEER, SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR-13 OF 2020-21 REPAIR / MAINTENANCE OF HT E/M EQUIPMENTS AND ALLIED SERVICES AT MILITARY STATION SRI GANGANAGAR (3RD CALL)
2020_MES_353071_3
CA NO. CWE SGNR - 13 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SRI GANGANAGAR
Class D
Category b(ii)
10 documents required · 10 mandatory
₹500
GE SRI GANGANAGAR
₹59,800
Yes
1 Oct 2020
22 Aug 2020
8 Sept 2020
22 Aug 2020
5 Sept 2020
29 Aug 2020
60 days
Amount
Supply & fixing for aluminium strip 25 x 3 mm thick fixed in ducts/on wall/in trenches/floor etc and jointing for interconnection of earthing fixed to equipment, test point including drilling holes and jointing with aluminium nuts, bolts and washers complete all as specified and directed by Engineer-in-Charge.
M & L for jointing and testing heat shrinkable, outdoor type, end termination cable jointing kit, suitable for 11KV under ground earthed system 3 core XLPE cable of size 50 to 95 Sqmm including making connections complete all as specified and directed by Engineer-in-Charge.
M & L for jointing and testing heatshrinkable outdoor type, end termination cable jointing kit, suitable for 11KV under ground earthed system 3 core XLPE cable of size 120 to 185 Sqmm including making connections complete all as specified and directed by Engineer-in-Charge.
M & L for jointing and testing heat shrinkable outdoor type, end termination cable jointing kit, suitable for 11KV under ground earthed system 3 core XLPE cable of size 240 to 300 Sqmm including making connections complete all as specified and directed by Engineer-in-Charge.
Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the LT/HT overhead lines conductors with hacksaw / axe to clear the LT/HT line upto 3 metre on each side including disposal of trimmed branches 100 Metre away inside the station area & clearing site complete all as specified and directed by Engineer-in-Charge. Note :- 3 metre width on each side (Horizontal/vertical) of LT/HT line shall be cleared.
M&L for opening the joints of HT overhead conductor from the end of poles, stretching the overhead aluminum conductor with chain pulley and other T&P machineries, refixing the overhead conductor at the same place such that sagging of conductor is not more than 3% complete all as specified and directed by Engineer-in-Charge. Note : Length of each OH conductor to be measured.
Supply and fix in repair pin insulator of size 150mm height, 150 mm dia polymer type tested with CPRI Lab, white, brown or green insulator suitable for 11 KV grade including one galvanized mild steel spindles two GI washer & one GI nut complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair disc insulators, vitreous porcelain /polymer type150 mm high and 150 mm dia ball and socket type, white, brown or green of two in series assembly for tension with tension clamps for conductor working pressure 11000 volts grade complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with 2 Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame 40 x 40 x 6mm on top and excavation/ earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. (Payment to be made after result should berequired less than 5 Ohm) Note:- (i) Outer edge of earth pit shall be 1 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe upto earth pit shall be provided in slantling position as included in this item.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel & wiremesh, PCC chamber in cement concrete (1:2:4) type B1 including CI cover with frame 40x40x6mm angle iron frame on top of pit cover and excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. complete all as specified and directed by Engr-in-charge. (Payment to be made after result should berequired less than 5 Ohm) Notes :- (i) GI wire upto earth test point/equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1 metre away from the outer edge of PCC chamber. (iii) Water pipe upto earth pit shall be provided in slanting position as included in this item.
Supplying and fix in repair air break gang operated switch, triple pole, 11 KV (outdoor type) mechanically operated, suitable for horizontal or vertical mounting fixed type complete with 12 insulators and steel frame, with operating mechanism worked from ground level with fixed contacts of phosphorous bronze and moving control of copper, for current rating upto 200 Amps including GI pipe heavy duty of required size and with locking arrangement including Godrej (Freedom) 50mm pad lock with two keys with fuse mounts, fuse carriers and HT fuse elements having 400 amp rating suitable for HT 11 KV, 50 Hz, AC supply including necessary electric connections, mild steel ISMC-75 of required length fixed with mild steel clamps made out of 50mm x 6 mm flat iron,nut,bolts and washers of required size for fixing GOD complete and painting structural steel surface with 2 coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Supplying and fix in repair air break gang operated switch, triple pole, 11 KV (outdoor type) mechanically operated, suitable for horizontal or vertical mounting fixed type complete with 12 insulators and steel frame, with operating mechanism worked from ground level with fixed contacts of phosphorous bronze and moving control of copper, for current rating upto 400 Amps including GI pipe heavy duty of required size and with locking arrangement including Godrej (Freedom) 50mm pad lock with two keys with fuse mounts, fuse carriers and HT fuse elements having 400 amp rating suitable for HT 11 KV, 50 Hz, AC supply including necessary electric connections, mild steel ISMC-75 of required length fixed with mild steel clamps made out of 50mm x 6 mm flat iron,nut,bolts and washers of required size for fixing GOD complete and painting structural steel surface with 2 coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Supplying and fix in repair air break gang operated switch, triple pole, 33 KV (outdoor type) mechanically operated, suitable for horizontal or vertical mounting fixed type complete with 12 insulators and steel frame, with operating mechanism worked from ground level with fixed contacts of phosphorous bronze and moving control of copper, for current rating upto 630 Amps including GI pipe heavy duty of required size and with locking arrangement including Godrej (Freedom) 65mm pad lock with two keys with fuse mounts, fuse carriers and HT fuse elements having 630 Amp rating suitable for HT 33 KV, 50 Hz, AC supply including necessary electric connections, mild steel ISMC-75 of required length fixed with mild steel clamps made out of 50mm x 6 mm flat iron,nut,bolts and washers of required size for fixing GOD complete and painting structural steel surface with 2 coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
S & F in repair lightning arrester expulsion type conforming to IS-3070 Part-II 1989 as amended upto date suitable for 33 KV earth system having discharged current rating 5 KA high current impulse with stand 65 KA for OH 33 KV line including bracket clamps nuts, washers and connecting to earth complete all as specified and directed by Engineer-in-Charge.
S & F in repair lightning arrester expulsion type conforming to IS-3070 Part-II 1989 as amended upto date suitable for 11 KV earth system having discharged current rating 5 KA high current impulse with stand 65 KA for OH 11 KV line including bracket clamps nuts, washers and connecting to earth complete all as specified and directed by Engineer-in-Charge.
S & F in repair pre-stressed cement concrete pole, 11 metre long of cross section 152mm x 152mm at top and 152mm x 260mm at bottom, class 9, complying with requirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and white colour up to 1.5 metre height from top of PCC pedestal/coping of poles and writing/ numbering of poles with synthetic enamel paint white in 80mm high letters over 150mm x 200mm black or yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation & earth work shall be measured and paid for separately. Vol of pole embeded in PCC shall be deducted for payment purpose.
S & F in repair pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 152mm at top and 102mm x 289mm at bottom, class 10, complying with requirements of IS-1678-1998 errecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and white colour upto 1.5 metre height from top of PCC pedestal/coping of poles and writing/ numbering of poles with synthetic enamel paint Black in 80mm high letters over 150mm x 200mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note :- PCC for foundation, cross arms and earth work shall be measured and paid for separately. Volume of pole embeded in PCC shall be deducted for payment purpose.
Supply and fixing in repair cross arms, bracings, stiffeners, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size as indicated or directed complete all as specified and directed by Engineer-in-Charge. Note :Exposed steel surface shall be treated with two coats of aluminium paint over a coat of red oxide primer and unexposed surface of steel sections shall be applied one coat of red oxide primer. The quoted rate shall be deemed inclusive of the above item.
Supplying, laying, jointing testing and commissioning in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade of cross-sectional area 185 Sqmm, 3 core, IS 7098 marked, suitable for HT 11 KV(E) system , laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing testing and commissioning in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade of cross-sectional area 95 Sqmm, 3 core, IS 7098 marked, suitable for HT 11 KV(E) system , laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge.
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M & L for sand cushioning with dry coarse sand to under ground cable below and around after laying the cable jently punning down complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
Supplying, jointing and testing cold shrinkable type, end termination cable jointing kit, outdoor type, suitable for 33KV under ground earthed system 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm including making connections complete all as specified and directed by Engineer-in-Charge.
Supply only microprocessor based relay of IDMT relay including testing, setting of relay for proper tripping according to load complete all as specified and directed by Engineer-in-Charge. Make : CG14N of Crompton & Greaves or equivalent as approved by GE
Supply only terminal bushing assembly (spout bushing) 11 KV VCB complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves
Supply only Tulip contact (isolating contact 630 A) 11 KV VCB complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves
Supply only circuit spout RYB (bus bar insulators) 61mm for 11 KV VCB complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves
Supply only vaccum interpreter chamber for 11 KV VCB complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves
Supply only spring charging gear for 11 KV VCB complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves
Supply only operating gear mech 11 KV VCB complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves
Supply only trip shaft for 11 KV VCB complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves
Supply only Tripping coil assembly 230 V AC for 11 KV complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves
Supply only Closing coil assembly 230 V AC for 11 KV complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves
Supply only trip roller for 11 KV VCB complete all as specified and directed by Engineer-in-Charge.
Supply only vaccum interupter bottles for 11 KV VCB complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves
Supply only Trip cross locking assembly for 11 KV VCB complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves
Supply only Auxiliary Contactor 11 KV VCB complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves
Supply only Auxiliary switch 4 pole for 11 KV VCB complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves
Supply only spring charging motor for 11 KV VCB complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves
S& F in repair handle for manual charging of Spring charging mechanism of VCBs consisting of gears grooves complete all as specified and directed by Engineer-in-Charge. Make : CROMPTON & GREAVES
M&L for surface dressing not exceeding averaging 15cm deep in soft/ loose soil and getting out including cutting of grass roots, bushes if any and filling of lower portion with soil obtained from cutting or dressing complete all as specified and directed by Engineer-in-Charge.
M&L for graded gravel/coarse stone aggregate 20 to 40 mm spread and levelled in layers complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation for poles, stays & mass concrete including necessary form work and fair finishing complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation for poles, stays , mass concrete,Pathway including necessary form work and fair finishing complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair shackle type insulators, vitreous polymer white, brown or green for working pressure 1100 volts grade of 100 mm height and 115 mm dia including galvanized mild steel straps of 31mm x 5mm size,14mm dia insulator bolts, washers and nuts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair stay assembly complete with accessories as shown in electrical plate No 1 using stay rod 20 mm dia x 1.8 metre long, stay bow 14mm dia and stay plate 30 cm x 30 cm x 6 mm including stay wire 8 SWG x 7 strands, loop type insulator, stay clamps and painting to exposed surfaces of mild steel work with two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.
Supplying, fixing & stretching in repairs aluminium conductor steel, reinforced (ACSR) of any size fixed on HT/LT poles fixed on insulators and binding with & including binding wire 14 SWG complete all as specified and directed by Engineer-in-Charge. Note : The weight of binding wire shall not be considered for payment.
Supply & fix for continuous earth wire/guard cradle hexagonal rectangular, fabricated out of 3.15 or 4mm dia galvanized steel wire including mild steel wire of 1.63mm dia complete all as specified and directed by Engineer-in-Charge. Note : For payment purpose weight of 3.15 or 4 mm dia galvanized wire shall only be taken and clips & clamps eye hooks shall be measured and paid for separately.
Supply and fix in repair GI pipe 100 mm bore light grade for protection of cable including provision of clamps, nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs GI pipe 50 mm bore light grade for protection of cable including provision of clamps, nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directed by Engineer-in-Charge. Note for Srl Item No 55 & 56: (i) Excavation & earth work shall be measured and paid separately under respective item of this Schedule.
M & L for boring hole across the Road/plinth/hard standing by trench less technology method suitable for 100mm bore pipe for 0.4 mpa working pressure for cable passing without damaging Road / Plinth /Floor complete all as specified and directed by Engineer-in-Charge.
Supplying and laying un-reinforced pre cast concrete cable cover class HV type 1 flat size 300 x 180 mm x 40mm complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking down old U/S burnt out fixed female contact from the existing position and supply and fix new female contact of hard drawn strips of air break switch 11000 Volts grade up to 400 Amp capacity out door type fixed with suitable size of nuts bolts and washetrs etc and applying petroleum jelly for smooth operation including testing complete all as specified and directed by Engineer-in-Charge. Make :- JAYSHREE VERSATEC / JSI or equivalent as approved by GE
Disconnecting and taking down old U/S burnt out moving male contact from the existing position and supply and fix new moving male contact of hard drawn strip of air break switch 11000 Volts grade up to 400 Amps capacity out door type fixed with suitable size of nuts bolts and washers etc and applying pertoleum jelly for smooth operation including testing complete all as specified and directed by Engineer-in-Charge. Make :- JAYSHREE/VERSATEC / JSI or equivalent as approved by GE
Disconnecting the electric supply and taking down the U/S HT jumpers of bus bar/two/four ple structure and out point and supply and fix new HT jumpers of any length with suitable size of ACSR conductor and lugs PGI clamps and testing complete all as specified and directed by Engineer-in-Charge.
Cutting the burnt out portion of the HT 11 KV grade underground XLPE cable of size 50 to 95 Sqmm 3 core, supply and jointing HT cable straight through joint (Heat shrinkable) 11kV grade of size 50 to 95 Sqmm 3 core including necessary cable and testing complete all as specified and directed by Engineer-in-Charge.
Cutting the burnt out portion of the HT 11 KV grade underground XLPE cable of size 120 to 185 Sqmm 3 core, supply and jointing HT cable straight through joint (Heat shrinkable) 11kV grade of size 120 to 185 Sqmm 3 core including testing complete all as specified and directed by Engineer-in-Charge.
M&L for site clearance around 3mtrs of 4 pole structure including surface dressing not exceeding averaging 15cm deep in soft/ loose soil and getting out including cutting of grass roots, bushes, tree branches and tree not exceeding 15 cm girth if any and filling of lower portion with soil obtained from cutting or dressing complete all as specified and directed by Engineer-in-Charge.
M&L for site clearance around 3 mtrs of 2 pole structure including surface dressing not exceeding averaging 15cm deep in soft/ loose soil and getting out including cutting of grass roots, bushes, tree branches and tree not exceeding 15cm girth if any and filling of lower portion with soil obtained from cutting or dressing complete all as specified and directed by Engineer-in-Charge.
M&L for site clearance around 3 mtrs of transformer plateform/ 3mtrs around of fencing of transformer plateform,including surface dressing not exceeding averaging 15cm deep in soft/ loose soil and getting out including cutting of grass roots, bushes, tree branches and tree not exceeding 15 cm girth if any and filling of lower portion with soil obtained from cutting or dressing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for out door type incl. removing of existing of 33 KV, 50 Hz, Single phase outdoor type,18.4 KA for 1 Sec., oil-filled current transformer (LIVE tank type)- Ratio-200-100/5 A, two core, STC: 18.4 KA for 1 Sec, Creepage: 900 mm, Insulation level: 70 KV/170 KV peak Core-1 :Class 1.0 ,15 VA, Core-2 : class 5P10,15VA suitable for 33 KV with suitable size of PG clamp complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for copper wire 12 core 2.5 sqmm cable for control cable of breaker to control relay panel complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for copper wire 4 core 4 sqmm cable for control cable of breaker to control relay panel complete all as specified and directed by Engineer-in-Charge.
Repairs / replacement, Testing and commissioning including calibration of all instrument & relay etc of VCB 11 KV 650 Amp and reconnecting of removing incoming busbar and outgoing HT cables with suitable packing and all accessories. incl. with maintenance of Opening of VCB front door and rear door with isolated through earthed and removing the both ends HT Cable (outgoing and Incoming busbar) and meggering through HT megger of CTs and supply and fixing Vaccume interrupter of VCB indoor type incl. removing of existing of suitable Current Transformer capacity 400-200/5-5 Amp pressure rating 11 KV complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair indoor (as per requirement) potential transformer (PT) 200-400A, 11 KV complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with subclass‘B’ bricks, straight orcurved on plan exc 6m mean radius built in with CM 1:3 complete all as specified and directed by Engineer-in-Charge.
M/L for fabrication of gates of angle/pipes or any other section with gusset plates, rails, braces etc, complete, drilling for fixing of sheel sheeting ot other covering etc to be preprepared for hanging or sliding with and including either hooks hinges or steel hanging door fitting also fastening and fixing complete including painting with two coats of approved colour over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
S&F for chain link MS galvanised fancing of any size and type including lines wires, straining bolts and binding wires etc complete all as specified and directed by Engineer-in-Charge.
S&F for Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. (each line wire to be measured) complete all as specified and directed by Engineer-in-Chage.
M/L for galvasied mild steel channel, angle section etc for post of chain link fencing including notching for wire etc confirming to Fe 290 grade, embedded in PCC complete all as specified and directed by Engineer-in-Charge. Note : PCC shall be measured and paid seperately under respective items.
Supply only 10mm dia MS round bar for fixing of chain fencing with post complette including painting with two coats of approved colour over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
S& F for 12mm dia 60mm long @450mm centre to centre MS scew bolt machine made with hexagonal or square head at one end and screwed the other screwed end fixed with washer complete all as specified and directed by Engineer-in-Charge.
M & L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nut of approved size for HT 25x20cm complete all as specified and directed by Engineer-in-Charge.
M & L for anti-climbing device spikes type fabricated out of MS bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed by Engineer-in-Charge. -------------------------------------------------------------------------------------------------------------- Note : A sum of Rs. 1,30,850.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 31 (Schedule of Credit) of Tender document
Ganganagar Enterprises
M/S Sonu Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .