Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.3 Cr+₹9.4 L (7.71%)Rejected-Finance | ₹1.3 Cr+₹9.4 L (7.71%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹1.4 Cr+₹15.5 L (12.7%)Rejected-Finance | ₹1.4 Cr+₹15.5 L (12.7%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹1.4 Cr+₹19.7 L (16.1%)Rejected-Finance | ₹1.4 Cr+₹19.7 L (16.1%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹1.5 Cr+₹27.3 L (22.3%)Rejected-Finance | ₹1.5 Cr+₹27.3 L (22.3%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
3 Jul 2020, 6:00 pmClosed
CE R AND D SECUNDERABAD
CE R AND D SECUNDERABAD
PROVISION OF TEST BED AT BENGALURU
2020_MES_311029_1
CERD/BAN/TOKEN/15 OF 2019-2020
Open Tender
Civil Works
Lump-sum
270 days
GE I R AND D WEST BENGALURU
CLASS B
CATEGORY a i
AND REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE I R AND D WEST BENGALURU
₹2.0 L
Yes
28 Aug 2020
1 Jan 2020
8 Jul 2020
1 Jan 2020
3 Jul 2020
17 Feb 2020
1 Jan 2020 - 8 Jan 2020
Amount
Schedule 'A' Part - I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl. item No. 1.01) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6.
Lumpsum price worked out by the contractor for Construction of test bed in double storey, including connecting corridor, complete all as shown on drawings and as specified.
Lump sum price worked out by the Contractor for "EXCAVATION, EARTHWORK AND SITE CLEARANCE” as listed in Schedule ‘A’ Part - II representing _______ % ________________ percent Above / Below the lumpsum price of `47,175.00 inserted by the MES in Schedule ‘A’ Part - II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - III representing __________ % ____________ percent Above / Below the lump sum price of `56,552.40 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for "EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - IV representing _______ % __________________ percent Above / Below the lump sum price of `30,514.75 inserted by the MES in Schedule ‘A’ Part - IV
Schedule 'A' Part - V This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item No. 6.00 to 36.00
Sl. Item No. 5.01 to 29.0 here-in-after shall constitute for "INTERNAL ELECTRIFICATION" Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through and including provision of 20mm dia rigid PVC conduit medium grade ISI marked and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, by means of saddles and clips etc, including provision of modular metal flush boxes (metal switch board of any type and size with GI metal box) with modular metal frame plate and white cover for housing switches, sockets, regulators etc., including 1.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one light point controlled by one 6 amps one way modular switch, complete all as specified and directed. NOTE: (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement etc.
All as per Sl. Item No. 6.00 here-in-before, but for fan point controlled one number one-way switch
All as per Sl. Item No. 6.00 here-in-before, but for exhaust fan point controlled one number one-way switch
All as per Sl. Item No. 6.00 here-in-before, but for one 3-pin 6 Amps socket outlet point controlled by one one-way switch on same board
Point wiring complete with 4.00 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through and including provision of 20mm dia rigid PVC conduit medium grade ISI marked and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, by means of saddles and clips etc, including provision of modular metal flush boxes (metal switch board of any type and size with GI metal box) with modular metal frame plate and white cover for housing switches, sockets, regulators etc., including 4.00 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for 15 Amp socket outlet, complete all as specified and directed. NOTE: (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement etc.
LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption <=20W, luminaire lumen >=2000 lm, system efficiency of >= 100 lumens/W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC62471 & electrical insulation class 1, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficiency>85%, power factor > 0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min) as per L7O criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level < 60 V DC as per IEC standard with LM70 & LM 80certification . MAKE:- Model No. LL20-281-XXX-65AL1 of WIPRO or Model No. BN100C LED 40S - 6500 PSU L120 GR of PHILIPS or techno- commercially equivalent model of BAJAJ / HAVELLS
Surface mounted LED luminaire 42W LED 2'x2' with CRCA powder coated housing with top cover for better aesthetic finish, HET diffuser for better light transmission and immaculate effect, power consumption<=42W, luminaire lumen>=3000lm, driver and accessories to be prewired, CRI>70, LED efficiency >97lm/W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC62471 & electrical insulation class 1 ,LED life with L70 criteria-50,000 hrs colour temp >5700k, Ingress protection IP-20, ambient temperature 0 to 500C, driver efficiency >85% , THD<10% as per IEC 61000-3-2, power factor >0.95, surge protection 2.5KV, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM79 & LM80 certification. MAKE:- Model No. B2SSQL43W of BAJAJ or Model No. PLUTO SURFACE 2X2PLS42WLED 840S of HAVELLS or techno- commercially equivalent model of WIPRO / PHILIPS
LED Security light with aluminium pressure die cast housing , high purity PC Fresnel diffuser with silicon gaskets for IP-65 protection, power consumption < 25W & luminaire lumen > 2500lm and system efficiency > 100lm/W, in built electronic driver prewired upto terminal block with driver efficiency > 85% power factor > 0.95, suitable for external pole/building upto 43mm, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC62471 & electrical insulation class, CRI>70, ambient temperature range 0-450C, THD<10%, colour temperature 5700K, surge protection in CM-3.5KV, 50000 burning hours as per L70 criteria, multistage constant current-constant voltage operated driver with range 150-270V AC and safety extra low voltage safe level < 60V DC as per IEC Standard. MAKE:- Model No. LR02-291-XXX-57-XX of WIPRO or Model No. ENDURAPEARLSL25WLED757SASYTOPC of HAVELLS or techno-commercially equivalent model in BAJAJ / PHILIPS
Ceiling fan BEE 5 star rated complete 1200mm sweep, energy efficient suitable to function on 230V, single phase, AC supply, white colour, with down rod 300mm long, capacitor 2.5mF, canopies, nuts, bolts and washers and connecting with and including provision of 3 core 1.5 sq.mm PVC sheathed flexible copper conductor from ceiling, writing MES number on ceiling fan motor complete all as specified and directed. MAKE:- Auro Plus of Crompton Greaves or techno-commercially equivalent model in BAJAJ / HAVELLS / USHA
Heavy duty exhaust fan 300mm sweep 900RPM cast iron body and blades with louvers and shutters without regulator suitable for 230V single phase AC supply with all fixing arrangments to fix on wall, including making holes on brick / stone walls and making good disturbed surfaces to match with the existing, including provision of 3-way procelain connector, copper bunched flexible three core 1.5sq.mm PVC insulated cable from connection point to fan, writing MES number on exhaust fan motor, complete all as specified and directed. MAKE:- Model No. EXHD300-4-1 of Crompton Greaves or techno-commercially equivalent model in BAJAJ / HAVELLS / USHA
VTPN MCCB DB, double door, three phase, 415 V, 4 ways suitable for MCCB FP as incoming and MCBs as outgoing, IP 43 protection complete all as specified and as directed. MAKE:- LEGRAND / L&T / SIEMENS / ABB
VTPN MCB DB, Double door three phase 415 V, 8 ways suitable for MCB FP as incoming and MCBs as outgoing, IP 43 protection complete all as specified and directed. MAKE:- LEGRAND / L&T / SIEMENS / ABB
MCCB FP, 415 V, 100 Amps, 50 Hz with thermal magnetic release & Ics=100%Icu with Icu=16 KA, adjustable overload min 70% to 100% complete all as specified and directed. MAKE :- Legrand (DPX) / L&T (D-Sine) / Siemens (3VT) / ABB (T-max) / Schneider (NSX)
MCB TP 415V, 32 Amps, 50 Hz, 'C' curve, 10 KA breaking capacity complete all as specified and directed.
MCB TPN 415V, 32 Amps, 50 Hz, 'C' curve, 10 KA breaking capacity complete all as specified and directed.
MCB SP 230V, 3 Amps, 50 Hz, 'C' curve, 10 KA breaking capacity complete all as specified and directed
MCB SP 230V, 6 Amps, 50 Hz, 'C' curve, 10 KA breaking capacity complete all as specified and directed.
MCB SP 230V, 16 Amps, 50 Hz, 'C' curve, 10 KA breaking capacity complete all as specified and directed.
MCB SP 230V, 20 Amps, 50 Hz, 'C' curve, 10 KA breaking capacity complete all as specified and directed. MAKE (for Sl. No. 19.00 to 24.00 here-in-before):- LEGRAND / L&T / SIEMENS / ABB
Single pole and neutral enclosure with a two pin and earth plug and socket complete including one double pole MCB 20 Amps, 50 Hz, 'C' curve, 10 KA breaking capacity complete all as specified and directed.
Sub main wiring complete with two runs of single core 4 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit of size not less than 25mm dia and its accessories and connecting terminal ends to DB's including providing one run of 4 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 4 sq.mm copper conductor, one run of 4 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring complete with two runs of of single core, 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit of size not less than 25mm dia and its accessories and connecting terminal ends to DB's including providing one run of 6 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring complete with 4 runs of of single core, 10 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit 32mm dia and its accessories and connecting terminal ends to DB's including providing 2 runs of 10 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Four runs of 10 sq.mm copper conductor, two runs of 10 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
LAN socket outlet RJ45 with shutter including modur white cover plate with frame, complete all as specified and directed.
Modular metal flush mounting boxes, concealed for mounting of LAN socket up to thre module etc., complete all as specified and directed.
LAN category-6 multi core cable (4-pair unshielded twisted pair cable) with high density polyethylene insulation, paired, fire retardant as IS / IEC 11801, drawn through and including provision of concealed non metallic rigid PVC conduit 20mm dia and its accessories and connecting terminal ends from one socket to another, complete all as specified and directed.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.3mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip 25mm x 4mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 40mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover (1:2:4) mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) Earth continuity conductor beyond 7.5metre shall be measured and paid under respective item of this Schedule.
Sl. Item No. 33.00 and 34.00 here-in-after shall constitute for "EXTERNAL ELECTRIFICATION" Metal enclosure for MCCB 160 Amps, three phase 415 V, IK 08, complete all as specified and directed. MAKE:- LEGRAND / L&T / SIEMENS / ABB / SCHNEIDER
MCCB FP, 415 V, 160 Amps, 50 Hz with thermal magnetic release & Ics=100%Icu with Icu=16 KA, adjustable overload min 70% to 100% complete all as specified and directed. MAKE :- Legrand (DPX) / L&T (D-Sine) / Siemens (3VT) / ABB (T-max) / Schneider (NSX)
Sl. Item No. 35.00 and 36.00 here-in-after shall constitute for "AIR CONDITIONING" Supply, Installation, testing and commissioning of hi wall Split type air condioning unit(Inverter type), BEE five star rated, of capacity 2.0 TR complete with drive motor, air cooled condenser with all accessories varied speed and dual rotary compressor, including fixing the outdoor units as per manufacture recommendation and fixing indoor unit on wall, providing and making interconnection including refrigerant piping (upto 7.5 RM) with nitryle rubber insulation and control cable from indoor to outdoor, power cabling from isolator/enclosure to unit, first charging of non CFC/ non HCFC of refregerant gas including cordless remote, drain piping of 25 mm dia for connecting drain lines from indoor unit to maximum of 3.0 mtrs to nearest drain points complete all as directed and specified. MAKE:- VOLTAS / LG / DAIKIN / O'GENERAL / BLUESTAR
Voltage stabilizer, wall mounted, naturally cooled, indoor type, Automatic Boost / Buck for low and high voltage correction equipped with electronic circuit, relays of single phase 50Hz AC supply, complete designed for input voltage of 170 to 250 Volts and output voltage stabilized at 230Volts with an accuracy of ± 2.5%, TDR to 3min ± 20% seconds, of 5KVA capacity, complete all as specified and directed. MAKE:- 'V' GUARD / K-LINE / VOLINA / APLAB
Raghavendra constructions
Meghana and Gowda Enterprises
Vinayaka Enterprises
UNITED ENGINEERS CORPORATION
shashi shekar construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .