Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | ₹11.4 L Quoted ₹12.2 L | L1 | Accepted-AOC LOWEST TENDERER. |
| 2 | L2₹13.2 L+₹1.1 L (8.87%)Rejected-AOC | ₹13.2 L+₹1.1 L (8.87%) | L2 | Rejected-AOC NOT LOWEST TENDERER. |
| 3 | L3₹17.8 L+₹5.7 L (46.6%)Rejected-AOC | ₹17.8 L+₹5.7 L (46.6%) | L3 | Rejected-AOC NOT LOWEST TENDERER. |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
11 Nov 2022, 6:00 pmClosed
GE AF NAGPUR
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR MAINTENANCE OF VARIOUS TYPES OF STREET LIGHT PERIMETER LIGHT FITTINGS AT VSN, MCCF, 22 P AND S, AKSC NAGPUR
2022_MES_557568_1
GE/NAG/22-23/8543/39
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF NAGPUR
As per NIT
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹30,000
23 Jan 2023
14 Oct 2022
18 Nov 2022
14 Oct 2022
11 Nov 2022
28 Oct 2022
Amount
Labour only for taking down street light/security light/garden light/flood light from any position, checking the serviceability of different spares / components / parts of security light fittings LED light fittings etc, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed by Engineer-in-Charge. NOTES FOR SCH `A’ ITEM NO 1:- (i) Fixing element of the new replaced part(s) is deemed to be included in the rates quoted by the contractor for above item and new parts shall be measured and paid separately as supply only against respective items of Sch ‘A’. (ii) Necessary T&P i.e. ladder, tools etc and screws, insulating tapes, internal wiring wire and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item.
Supply only following materials suitable for various type of street light, security light for replacing against item no 1 here in before. Make of spares CG,Philips,Wipro (a) Copper wound Ballast suitable for 400 watt SV/MH light fitting
(b) Lamp single end suitable for 400 watt MH light fitting
(c) Electronic igniters suitable for 400 Watt.
(d) Capacitor 33 mfd HPSV, MV, MH lamp fittings
(e) LED Lamp suitable for 9 W light fittings.
(f)Lamp holder suitable for 250/400 watt SV/MH lamp light fittings
(g) Driver for 40 Watts LED street light luminaries complete.Make : CG S0DQL1-54-700-40W
(h) Driver for 45 Watts LED street light luminaries complete. Make : CG S0DQL-65-700-45W
(j) Driver for LED street light / Flood light luminaries 90 to 125 Watt complete. Make : CG X100C070V143FNY1BO
(k) Driver for 135/150 Watts LED flood light luminaries complete. Make :CG X150C070V210FNI1BO
(l) Driver for Garden Light Bollard 10 Watt Make : CG or equivalent in specified makes
Taking down old unserviceable Street Light fittings and Supply fixing 90W LED street light with pressure die cast aluminum housing & toughened glass with IP-66 degree of protection, Individual LED's must have peanut lenses for better throw across & along the road ,with luminaire efficacy of greater than 85Lumen/Watt (Minimum lumen output of luminaire should be 3800Lumens ), color rendering (CRI) of ≥ 75 and co-related colour temperature (CCT ) of 5700K (± 500K) , The luminaire should have 5KV surge protection, PF ≥ 0.95, and total harmonic distortion of THD ≤ 10% , voltage range of 140-280V should be provided. Luminaire should have top maintainable driver compartment for easy access to driver during maintenance. The Driver used must be a constant current driver with efficiency of ≥ 85% The manufacturers LOGO must be Embossed/ Engraved in the housing of the luminaire complete all as specified and directed Make : CG LSTN-90-CDL-A or eqival,Wipro and Philips.
Supply and fix bracket for street light fittings made out GI pipe of light grade 1.5 m long each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 32 x 6 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with one coat of aluminium paint over a coat of red oxide primer including taking down old unserviceable bracket of any shape and size all as specified and as directed.
Taking down of Monkey guard ( which are fixed to protect the Bollard light), , preparing suface for painting, painting of Monkey Guard with black synthetic enameled paint two coat and re-fixing in original position including minor repair to PCC foundation etc complete all as specified and as directed. Note :- Rates for Nuts bolts, paint, cement, aggregate and sand have been included in Item rate of this item
Taking down Unserviceable Junction Box of street light for repair/replacement of wiring, connector, thimbles and copper wire 1.5 sqmm three core upto street light. Refixing of Junction Box after repair with new nut/bolts, locking arrangement and clamp with suitable size as directed by Engineer in charge Note :- Rates for minor spare of Juction box nuts/bolts, clamp, locking arrangement and wire have been included in Item rate of this item.
Taking down unserviceable Junction Box of Garden Light for repair/replacement of wiring, connector, thimbles and copper wire 1.5 sqmm three core upto street light. Refixing of Junction Box after repair with new nut/bolts, locking arrangement and clamp with suitable size as directed by Engineer in charge Note :- Rates for minor spare of Juction box such CI nuts/bolts, clamp, locking arrangement wire etc have been included in quoted rate of this item.
Taking down old Uunserviceable UG cable and Supply & Laying for XLPE insulated, screened,PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts grade cross sectional area 16 sq mm, 4 core in trenches or fixing in walls / poles or drawing through pipe including testing after laid and jointed all as specified and as directed. Make : Polycab, Havells, or equivalent
Taking down old unserviceable UG cable and Supply & Laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed. Make : Polycab, Havells, or equivalent
Taking down old unserviceable UG cable and Supply & Laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed. Make : Polycab, Havells, or equivalent
Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipes have been laid and tested complete all as specified and directed by Engineer-in-Charge
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed by Engineer-in-Charge
M & L for Double wall corrugated High density polyethylene pipes (HDPE) of size 40 mm dia laid in trenches for passing of LT cable complete all as specified and directed.
M & L for PCC cable route indicator in mix of 1:2:4 type B1 of size 450x200x75mm with oval shape and writing the letter HT/LT cable with synthetic enamel paint and embedded with PCC foundation type D2 1:4:8 of size minimum 250 mm depth including necessary earth work complete all as specefied and directed.
Excavation of road cutting by manually including making good to disturbed surface after the completion of work with PCC 1:2:4 type B-2 on top not less than 150 mm thick including levelling and cambering according to existing road surface, refilling, watering, ramming etc all as specified and as directed.
M & L for galvanised iron tubing light grade of size 40 mm dia with all fitting laid under floor / road crossing or in trenches or fixed to pole /walls with clamps as required including sealing of pipe ends with approval sealing compound etc complete all as specified and directed.
M&L for providing Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping, cable duct, cover slab and benching including all necessary form works complete all as specified and directed.
Dismantling and Taking down old unserviceable cable junction boxes and Supply and fix thermoplastic cable junction boxes IP 55/IP 65 with metric knockout for cable entry with terminal of size 210x155x92 mm on pole with MS clamps, nut bolts, washers and glands suitable for 16 sq mm 04 core cable with RYB cable terminal Bloack and all as specified and directed . Make Hansel Cat No DK 1600 G or equivalent in Neptune.
Dismantling and Taking out old unserviceable cable junction boxes and Supply and fixing thermoplastic cable junction boxes IP 66 "halogen free and weather proof" for outdoor Installation with metric knockout for cable entry of size130 x180x77mm fixing on pole with MS clamps, nut bolts, washers and glands suitable for 6 Sq mm 02 core cable with RYB cable terminal Block including taking down old unserviceable cable junction boxes all as specified and directed. Make : HENSEL Cat No DK-1000G or equivalent in Rittal.
Supply and fixing of Automatic street light Control Switch using infrared sensor based NATURE SWITCH for automatic switching of street light, Three phase load of 5 KW (Swadeep -02EC5KW3P) with 3 Nos Contactors, 3 Nos Incoming MCB, 3 Nos Outgoing MCB of capacity 20 Amps each phase, circuit wiring (Copper) of 10 Sqmm Nature switch operation should be based Nature light Lux level. required luminance level for switching OFF is less than 10 Lux. The sensor should also have part night operation facility of min. 4 hrs to max 12 hrs. The sensor alongwith suitable SMC encloure confirming to IP 66. The circuit should also have provision for Manual Operation i.e Sensor By-Pass Option setting features complete all as specified and directed. Model : Swadeep-66-5 kW3P or equivalent
Taking down old unserviceable copper wire, Supply and fix 2 core 2.5 sqmm PVC insulated PVC sheathed weather proof multistranded Copper conductor cable 1100 volts grade drawn through in GI conduit, pole etc from junction box to street light fitting all as specified and directed. Note- GI tube shall be measured and paid separately
Supply and fix 2 core 1.5 sqmm PVC insulated PVC sheathed weather proof multistranded Copper conductor cable 1100 volts grade drawn through in GI conduit, pole etc from junction box to street light fitting all as specified and directed. Note- GI tube shall be measured and paid separately
Taking down old unserviceable GI Pipe, Supply and fix 15 mm dia GI tubes light grade with all fitting from junction box to street light fittings with clamps, nuts & bolts complete all as specified and as directed
Taking down old unserviceable PVC wire, Metatrial and labour for replacement of service cable of PVC insulated, unsheathed aluminium multistranded conductor twin core 4 Sqmm size including dismantling of existing unserviceable cable complete all as directed
Taking down old unserviceable PVC wire, Matrial and labour for replacement of service cable of PVC insulated, unsheathed aluminium multistranded conductor twin core 6 Sqmm size including dismantling of existing unserviceable cable complete all as directed
Taking down old unserviceable PVC wire, Material and labour for replacement of service cable of PVC insulated, unsheathed aluminium multistranded conductor twin core 10 Sqmm size including dismantling of existing unserviceable cable complete all as directed
Dismantling and Taking out old unserviceable time switch and Supply and fix astro time switch for controll street light 3P module,24 hours program,with battery back up of 100 hours complete all as specified and as directed. Make : L&T Cat No Cat No AUTS02AST00 or equivalent in Legrand , Siemens etc.
Dismantling and Taking out old unserviceable time switch and Supply and fix analog time switch for controll street light 3P module,24 hours program,with battery back up of 100 hours complete all as specified and as directed. Make : L&T AUTS03ANA00 or equivalent in Legrand , Siemens etc.
Dismantling and Taking out old unserviceable contactor and Supply and fix power contactor 4 pole 415 Volts, 40 Amps , MCX 04 coil voltage of rating 240 Volts including taking down old unserviceable power contactor all as specified and as directed by Engr-In-Charge Make:- L&T Cat NoCS97012, or equivalent in Legrand , Siemens ,GE
Dismantling and Taking out old unserviceable contactor and Supply and fix power contactor 2 pole 240 Volts,40 Amps , MCX 04 coil voltage of rating 240 Volts including taking down old unserviceable power contactor all as specified and as directed by Engr-In-Charge Make :-Legrand ,L&T Cat NoCS90242, or equivalent in Legrand , Siemens, GE
Taking down old unserviceable, Supply & fixing MCB TPN 32 amps of 10 KA in existing panel with incoming and outgoing connection complete all as directed Make : Legrand 4086 58 or equvalant in Havells, C&S, Schnieder or etc
M&L for preparing surfaces of street light poles of any type size including street light brackets, bracket clamps, cable protection pipe, terminal box, stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of aluminium paint completely including painting strips on poles with one coats of sky blue and white synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
M&L for stickering of pole No. with letters of size 15 Cm height on pole/ plate complete all as specified and as directed by engineer in charge.
Dismantling and Taking out old unserviceable Garden/Pathway Light fittings and Supply & fix of Integral LED Ground mounted Bollard of 10 watt Inverted pyramid tripod led bollard with soft 360 degree light with a system lumen output of 300 lumens and a minimum system efficency of 35 lm/W. The luminaire shall have a rated system lifetime of 25,000 buring hours at L70. The luminare should have a color temperature of 3000K and CRI>75. The luminaire shall meet IP65 & IK10 rating with THD < 20% and PF > 0.9. The luminaire housing should made of pressure die cast aluminium with polycarbonate diffuser complete all as specified and directed Make:- CG Cat No.LBLSN-10-CDL or equivalant in Philips, GE
Dismantling and Taking out old unserviceable Garden/Pathway Light fittings and Supply, Installation, Testing and Commissioning of Integral LED Ground mounted Bollard Inverted LED bollard 10 W with soft 360 degree light with a system lumen output of 300 lumens and a minimum system efficency of 35 lm/W. The luminaire shall have a rated system lifetime of 25,000 buring hours at L70. The luminare should have a color temperature of 3000K and CRI>75. The luminaire shall meet IP65 & IK10 rating with THD < 20% and PF > 0.9. The luminaire housing should made of pressure die cast aluminium with polycarbonate diffuser complete all as specified and directed Make:- CG Cat No.LBLA3-10-CDL or equivalant in Philips, GE
Dismantling and Taking out old unserviceable street Light fittings and Supply, Installation, Testing and Commissioning of Integral LED street light luminarie 45 Watt die cast aluminium housing designed to act as heat sink for efficient dissipation of heat. Elecrochemically brightened and anodized aluminium reflector. Heat resistant toughened glass is provided with die cast aluminium frame. (IK 08) luminarie provided with a mounting bracket for aiming adjustment. Driver is provided with input voltage surge (4kV), open and short circuit protection. system wattage 45 W and power lumen efficacy 120 lum/w complete all as specified and directed Make Havells LHETADU7PA7J045 or equivalant in CG, Philips, GE
Dismantling and Taking out old unserviceable flood Light fittings and Supply, Installation, Testing and Commissioning of Integral LED flood light luminarie 150 Watt die cast aluminium housing designed to act as heat sink for efficient dissipation of heat. Elecrochemically brightened and anodized aluminium reflector. Heat resistant toughened glass is provided with die cast aluminium frame. (IK 08) luminarie provided with a mounting bracket for aiming adjustment. Driver is provided with input voltage surge (10kV), open and short circuit protection. system wattage 150 W and power factor 0.90 complete all as specified and directed Make CG CFS-501-150-57-60D-SL-GL-NGG or equivalant in Philips, GE
Dismantling and Taking out old unserviceable flood Light fittings and Supply, Installation, Testing and Commissioning of Integral LED flood light luminarie 50 Watt die cast aluminium housing designed to act as heat sink for efficient dissipation of heat. Elecrochemically brightened and anodized aluminium reflector. Heat resistant toughened glass is provided with die cast aluminium frame. (IK 08) luminarie provided with a mounting bracket for aiming adjustment. Driver is provided with input voltage surge (10kV), open and short circuit protection. system wattage 60 W and power factor 0.90 complete all as specified and directed Make CG CFS-504-50-57-60D-SL-GL-NSG or equivalant in Philips, GE
Dismantling and Taking out old unserviceable Post Top Light fittings and Supply and fixing in replacement for Post Top latern fitting with LED Decorative indirect posttop for garden,Gate,landscape lighting. IP 65 protection.Resistant to impact and corrosion. Glare-free and better uniformilty and complete all as directed by Engineer-in-Charge Make : CG Cat No LPTO-40-CDL -M or equivalent Philips, GE
Taking down old unserviceable Post Top lantern fitting Supply and fixing Post Top lantern fitting with LED lamp 9 Watts opal acrylic diffuser and accessories including nut, bolt, washers all as specified and directed.
Taking down old unserviceable light fittings, Supply & fixing of Spike Garde LED light 12 Watt (Green Colour) die cast aluminium housing black colouree floor mounted outdoor use, colour green, Input Voltage-AC 140V-265V, PF-> 0.9, Power consumption 12 + 10% Rated Frequency- 50Hz, luminus flux - > 1200 Lm, LED light source - SMD,Color Rendering Index (CRI) > 80, Colour Temperature - 3000K(WW), 6000 K(WH) Working Temperature - 0oc to 500c , Rated life > 40,000 hrs, IP rating-IP65, Surge Protectio Upto 3KV including taking down complete all as specified and directed Make : Luker (Product Code- LSSPK12W\ ) /CG / Philips/ GE
Taking down old unserviceable light fittings, Supply & fixing pathway LED light 6 Watt die cast aluminium housing silver gray floor/Wall recess mounted outdoor use, colour warm white, Input Voltage-AC 140V-265V, PF-> 0.9, Power consumption 6W + 5% Rated Frequency- 50Hz, luminus flux - > 400 Lm, LED light source - SMD, Beam Angle-60 deg, Color Rendering Index (CRI) > 80, Colour Temperature - 3000K(WW), Working Temperature - 0oc to 500c , Rated life > 50,000 hrs, IP rating-IP65, Surge Protectio Upto 3KV including taking down complete all as specified and directed Make : Luker (Product Code-LOUR6)/CG/ Technolite
Taking down old unserviceable light fittings,Supply & fixing of outdoor garden light 20W die cast aluminium housing dark gray surface mounted Flood light outdoor use, colour warm white, Input Voltage-AC 100V-265V, PF-> 0.9, Power consumption 20W + 10% Rated Frequency- 50Hz, luminus flux - > 2000 Lm, LED light source - COB,Color Rendering Index (CRI) > 80, Colour Temperature - 3000K(WW), Working Temperature - 0oc to 500c , Rated life > 50,000 hrs, IP rating-IP65, Surge Protectio Upto 3KV complete all as specified and directed Make Luke (Product Code-LODSP20)/CG/ Philips/ GE
Taking down old unserviceable light fittings, Supply & fixing of outdoor Wall light 2 x 3W die cast aluminium housing dark gray wall mounted outdoor use, colour warm white 3000K, Input Voltage-AC 140V-265V, PF-> 0.9, Power consumption 6W + 10% Rated Frequency- 50Hz, luminus flux - > 600 Lm, LED light source - COB,Color Rendering Index (CRI) > 80, Colour Temperature - 3000K(WW), Working Temperature - 0oc to 500c , Rated life > 50,000 hrs, IP rating-IP65, Surge Protectio Upto 3KV complete all as specified and directed Make Luke (Product Code-LODSQUPD10D)/CG/ Philips/ GE
M & L for double drum winch 350 kg load for high mast light to move upward and downward for repair purpose complete all as specified and directed.
M & L for fixing for trailing cable copper armoured 5 core 2.5 Sqmm for high mast light complete all as specified and directed.
M & L for stainless steel wire rope 6 mm for high mast light complete all as specified and directed.
M & L for 0.75 HP motor for to move upward and downward to high mast light complete all as specifed and directed. Make : CG/KIRLOSKAR/CALAMA/KSB or equivalent
Dismantling and Taking out old unserviceable flood Light fittings and Supply, Installation, Testing and Commissioning of Integral LED flood light luminarie 250 Watt die cast aluminium housing designed to act as heat sink for efficient dissipation of heat with toughened glass cover having system limen output>27500 lumens, All LEDs are Osram LEDs with individual lens, input voltage working range is 120Vac to 280 Vac with upper limit cut of at 300Vac, Fixture can with stand for 8hr in case of High voltage fault upto 400Vac, potted drivers is used with 4KV internal surge protection, Short Circuit Protection, Open Circuit Protection, High & Low voltage protection with one External 10KV External Surge protection, Fixture is IP66 protected & IK08 procted, THD<10%, CCT 5700+/-300K, PF>0.9, cable entry through PG9 Cable gland. Elecrochemically brightened and anodized aluminium reflector. Heat resistant toughened glass is provided with die cast aluminium frame. (IK 08) luminarie provided with a mounting bracket for aiming adjustment complete all as specified and directed Make : CG CFS-506-250-57-60D-SL-GL-NGG or equivalant in Philips, GE
Repair/maintenance/servicing of highmast lighting system complete and making jammed head free for upward and downward movement by placing dislocated wire ropes in pulley/drum and providing necessary oiling and geasing of moving parts etc. complete all as specified and as directed. Note :- Necessary labour, T&P and minor parts required to free up the highmast light head and servicing of complete system is deemed to be included in the rate quoted by the contractor and major parts will be measured and paid under relevent items
Chinmaya Enteprises
Sharma Electrical and Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .