Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.3 L+₹3.6 L (24.7%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹20.5 L
EMD Value
₹41,000
Closing Date
12 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Aditya Vanka
GE Navy Lakshadweep Coast Guard Road Kavaratti Island UT Of Lakshadweep 682 555
COMPREHENSIVE MAINTENANCE OF DG SETS OF CAPACITIES 20 KVA TO 100 KVA AT VARIOUS ISLANDS UNDER GE NAVY LAKSHADWEEP
2021_MES_474823_1
8296/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Lakshadweep
As per Tender documents
8 documents required · 8 mandatory
₹500
GE Navy Lakshadweep
₹41,000
Yes
7 Jun 2022
13 Sept 2021
14 Oct 2021
13 Sept 2021
12 Oct 2021
27 Sept 2021
15 Sept 2021 - 22 Sept 2021
60 days
Amount
Material and labour for Quarterly Maintenance and servicing of DG Sets comprising Prime mover and alternator with accessories, control panel and connected electric circuits with various type of sensors etc... including checking lubricating oil, coolent, filters,V-belt, self starter, battery power, gauges and other connected accessories, cleaning of alternator with vaccum cleaner ,attending faults of AMF panels and replacing the defective parts and identifying malfunction of the DG Set (if any) of following capacities complete all as specified and directed by Engineer-in-Charge:- Notes:- (a) Major spares of DG Set will be measured and paid seperately under relevent items of the Schedules. (b) Minor spares like nuts/bolts, washers, oil seal, gaskets, cotton waste, clamps shall deemed to be included in the job.
(a) DG Set of capacity 20/25 KVA
(b) DG Set of capacity 30/45 KVA
(c) DG Set of capacity 62.5/ 63 KVA
(d) DG Set of capacity 100 KVA
Dismantling radiator assembly from the engine of 100 KVA capacity DG sets by disconnecting inlet and outlet connection overhauling / servicing the radiator, descaling and servicing the radiator internally and externally by using chemicals, including soldering the copper tubes and tank etc for arresting leakage, assembling back including necessary welding and with additional bracket as required. refixing, reconnecting and testing for proper functioning complete all as specified and directed by Engineer-in-Charge.
Description all as per Sl item No. 2 above but for DG Set of capacity 62.5 / 63 KVA
Description all as per Sl item No. 2 above but for DG Set of capacity 30/45 KVA
Description all as per Sl item No. 2 above but for DG Set of capacity 20 / 25 KVA
Dismantling of fuel injection pump assembly complete from the engine of DG Sets, servicing, overhauling, replacement of valves, washers etc..., assembling, calibration, setting for proper function, reassembling and re-fixing all as specified and as directed by Engr-in-charge for the following capacity :-
(a) DG Set of capacity 20/25 KVA
(b) DG Set of capacity 30 / 45 KVA
(c) DG Set of capacity 62.5 / 63 KVA
(d) DG Set of capacity 100 KVA
Disconnecting and taking down out going cables from the DG sets and cutting removing the burnt cable ends and thimbling and refixing back including provision of cable glands and testing for the following capacites of DG sets, complete all as specified and as directed by Engineer-in-Charge:-
(a) DG Set of capacity 20/25 KVA
(b) DG Set of capacity 30/45 KVA
(c) DG Set of capacity 62.5/63 KVA
(d) DG Set of capacity 100 KVA
Supply and fixing in replacement, spin on fuel filter (Pre and fine filter) element with "O" ring for generator set of following capacity, complete all as specified and as directed by Engineer-in-Charge :-
(a) DG Set of capacity 20/25 KVA
(b) DG Set of capacity 30 / 45 KVA
(c) DG Set of capacity 62.5 / 63 KVA
(d) DG Set of capacity 100 KVA
Supply and fixing in replacement, Dry type Air filter element Inner and Outer unit as required at site with 'O' Ring suitable for following capacity DG Set, complete all as specified and as directed by Engineer-in-Charge:-
(a) DG Set of capacity 20/25 KVA
(b) DG Set of capacity 30 / 45 KVA
(c) DG Set of capacity 62.5 / 63 KVA
(d) DG Set of capacity 100 KVA
Supply and fixing in replacement, Lub oil filter element with 'O' Ring suitable for following capacity DG Set, complete all as specified and as directed by Engineer-in-Charge:-
(a) DG Set of capacity 20/25 KVA
(b) DG Set of capacity 30 / 45 KVA
(c) DG Set of capacity 62.5 / 63 KVA
(d) DG Set of capacity 100 KVA
Supply and fixing in repairs, By pass filter element with 'O' ring suitable for following capacity DG Set, complete all as specified and as directed by Engineer-in-Charge:-
(a) DG Set of capacity 20/25 KVA
(b) DG Set of capacity 30 / 45 KVA
(c) DG Set of capacity 62.5 / 63 KVA
(d) DG Set of capacity 100 KVA
Supply and fixing of V-belt suitable for following capacity DG set including removing old unserviceable fan belt, complete all as specified and as directed by Engineer-in-Charge :-
(a) DG Set of capacity 20/25 KVA
(b) DG Set of capacity 30 / 45 KVA
(c) DG Set of capacity 62.5 / 63 KVA
(d) DG Set of capacity 100 KVA
Supply and fixing (in repairs) Water Pump Assy suitable for following capacity DG set including removing old unserviceable water pump assy, complete all as specified and as directed by Engineer-in-Charge :-
(a) DG Set of capacity 20/25 KVA
(b) DG Set of capacity 30 / 45 KVA
(c) DG Set of capacity 62.5 KVA
(d) DG Set of capacity 100 KVA
Supply & fixing common rail diesel sensor suitable for 63 KVA DG Set engine (as per sample), complete all as specified and as directed by Engineer-in-Charge
Description all as per Sl item No 14 here-in-before but for DG Set capacity 100 KVA
Supply and replacement Water outlet and inlet hose pipe from radiator to Engine and back from Engine to radiator, complete all as specified and as directed by Engineer-in-Charge
Supply and replacement Lub oil pipe armoured of suitable length and socket of size 15mm dia, complete all as specified and as directed by Engineer-in-Charge
Supply and fix in replacement for Anti vibration rubber pad for side radiator complete all as specified and as directed by Engineer-in-Charge
Supply and fix in replacement for DC ammeter 12 V of range (-) 30- 0- (+)30 A, complete all as specified and as directed by Engineer-in-Charge .
Supply and replacement of Lub oil pressure guage 0 to 10 kg / sq cm, complete all as specified and as directed by Engineer-in-Charge.
Supply and top up coolent oil, complete all as specified and as directed by Engineer-in-Charge
Supply and top up with engine oil 15W40 grade, complete all as specified and as directed by Engineer-in-Charge
Supply and fix in replacement of battery connecting single core copper cable 16sqmm with battery terminal made of brass with nuts/bolts/washer (as per sample), complete all as specified and as directed by Engineer-in-Charge
Supply and top up Battery Distilled water complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in repalcement for SMPS battery charger 12V/24V DC including all fixing accessories and re-wiring with suitable size copper conductor FRLS grade PVC insulated two core cabledrawn through PVC conduit not less than 20mm dia as required at site, complete all as specified and as directed by Engineer-in-Charge
Disconnecting and dismantling 12 V battery charging alternator assembly replacing the unserviceable burnt coil assembly, re-assembling, refixing to engine and testing for satisfactory charging of battery, complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repair, battery 12V, 100 AH, initial charging, filled with required electrolite/distilled water and fixing/connecting with electric connector cable, complete all as specified and as directed by Engineer-in-Charge
Description all as per Sl item No. 27 here-in-before but of capacity 120 AH.
Supply and fixing in repairs, AVR (Auto Voltage Regulator) suitable for Generator Set having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4 A DC voltage regulation +/- 1% average volts, over excitation current tripping fuse protection 4A, fast acting and frequency 50Hz for the following capacities, complete all as specified and as directed by Engineer-in-Charge :-
(a) 20 KVA to 40 KVA
(b) 62.5 KVA to 100 KVA
Supply and fixing in replacement of Digital DG Controller suitable for any type DG Set of any capacity complete and connecting with existing electrical circuit, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs, Diods set (Rectifier) of Main alternator of DG Set of capacity 25 KVA, complete all as specified and as directed by Engineer-in-Charge
Description all as per Sl item No. 31 here-in-before but for DG Set capacity 45 KVA
Description all as per Sl item No. 31 here-in-before but for DG Set capacity 62.5/63 KVA
Description all as per Sl item No. 31 here-in-before but for DG Set capacity 100 KVA
Supply and fixing in repairs, Contactors, 4 pole, 100A, coil volt-240volts, AC 50Hz, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement, CT Coil with CT Ratio 100/5A, 5VA Cl 1.0 accuracy all as per IS 2705-1992, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement, Self Stater Assembly suitable for 63 KVA DG Set and connecting with electric circuit, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs, fuse unit 12 V DC (as per sample) suitable for DG Set control panel complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement, PVC connector (as per sample) suitable for connecting electric circuits, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement, PVC insulated Single core, 35 sqmm, copper conductor, stranded cable suitable for inter connection of electric network inside panel including provision of suitable size copper thimbles/lugs with nuts, bolts & washers (considered 02 thimbles/lugs per RM) complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement, PVC insulated Single core, 1.5 sqmm, copper conductor, stranded cable suitable for inter connection of electric network inside panel including provn of suitable size copper thimbles/lugs with nuts, bolts & washers (considered 02 thimbles/lugs per RM) complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement, On load change over switch 100 Amps, 415V, AC 50 Hz, front operated handle, totally enclosed in sheet metal enclosure including fixing on wall with suitable accessories and connecting the cable end with suitable size lugs, nuts/bolts/washers etc...complete all as specified and as directed by Engineer-in-Charge.
Description all as per Sl item No. 45 here-in-before but capacity 160 Amps
Description all as per Sl item No. 45 here-in-before but capacity 200 Amps
Material and labour for Minor Repair/cleaning of fuel tank, removing sludge, arresting leak using metal paste/sealent or by welding/soldering, replacement of diesel receiver pipe from lock to tank with clamp set all as required at site complete for the following Gen Set, complete all as specified and as directed by Engineer-in-Charge. :-
Material and labour for for minor repair to canopy and painting inside/outside area of DG Set 100 KVA comprising engine, alternator, Genset panel board and fuel tank and canopy, as per standard approved colour code with one coat of synthetic enamel paint, cleaning, scrubbing of all surface including writing in syntHetic enamel paint the SM MES numbers etc... complete all as specified and all directed by Engr-in-charge.
Description all as per Sl item No. 46 above but for 62.5/63 KVA Genset
Description all as per Sl item No. 46 above but for 20/25/30 KVA Genset
Dismantling,removing the self starter, motor from the engine of following capacity DG sets, opening the self starter body and overhauling/servicing, replacement of carbon brushes with holders, contact plates, jumping leads and seals, re-varnishing the field coil, armature, re-assembling, testing for smooth functioning and re-fixing with the engine and connecting complete all as specified and directed by the Engineer-in-Charge:-
(a) DG Set of capacity 25/ 30 / 45 KVA
(b) DG Set of capacity 62.5 / 63 KVA
(c) DG Set of capacity 100 KVA
Material and labour for asbestos rope 12 mm dia wrapped over the exhaust pipe and painting with heat proof paint of approved colour including taking down the old rope, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement LED phase indicator lamp assy RYB, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement, Water separator suitable for DG sets of capacity 62.5 KVA to 100 KVA, complete all as specified and as directed by Engineer-in-Charge.
Description all as per Sl item No. 54 here-in-before but DG Set of Capacity 25 KVA to 45 KVA
Supply and fix in replacement, PVC insulated Single core, 35 sqmm, Aluminium conductor, stranded cable suitable for connecting of earth chamber/electric network with DG Set incl required No of suitable size lugs, nuts, bolts & washers etc… complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Earthing complete with galvanised steel plate electrode 600 x 600 x 6mm thick buried directly in ground vertically to a depth not less than 2.25mtr below ground level with top edge of earth plate at a depth 1.5mtr below ground level connected with galvanised steel strip of size 25 x 4 mm as earthing lead by means of nuts bolts and washers of galvanized iron protected by 15mm dia light grade GI tubing, funnel, wire mesh, 20mm bore GI tubing medium grade watering pipe, including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle of suitable size, charcole and slat in alternate layers including necessary excavation and earth work in soft/loose soil all as shown in Electrical plate No. 3 of SSR part-I connected to earthing test point and testing complete including taking down of unserviceable materials of old earthing complete all as specified and as directed by Engineer in charge. Note:- (i) GI pipe and GI earth strip upto 7.5 mtr is deemed to be included in the unit rate quoted.
Supply and fix DG Set diesel tank lock (as per sample) with fixing accessories, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix DG Set canopy door hinges (as per sample) with fixing accessories, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix DG Set canopy door lock (as per sample) with fixing accessories, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for for checking of AMF panels including replacement of unserviceable parts such as Relays,Timers,Power contactors,Auxilary contactors,defective copper wiring,MCCBs etc... for DG Set, complete all as specified and as directed by Engr-in-charge. Note: - Spare parts shall be measured and paid separately under Supply only items
Supply only Auxiliary contactor 240 V 2 No. (+2NC).
Supply only ON and off delay timer 240 V AC
Supply only Earth fault relay.
Supply only Over load relay.
Supply only Under voltage relay.
Supply only SMPS 12 V DC output
Supply only DC power contactor for auto starting 12 V
Supply only Power Contactor MCX 22, 4 Pole
Supply only Power Contactor MCX11, 4 Pole
Supply only Power Contactor MCX 33, 4 Pole
Supply and fix in replacement of Power Contactor MNX 70 , 3P , 415 V including necessary wiring, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of Power Contactor MNX 110 , 3P , 415 V including necessary wiring, complete all as specified and as directed by Engineer-in-Charge.
Dismantling of 62.5 KVA Capacity alternator from Generator after Dismantling from Generaror shifting to workshop, taking out burnt out winding from Stator & Rotator, Cleaning thoroughly and rewinding the stator with suitable guage of super enameled copper conductor similar to that of existing size including necessary insulating material varnishing, heating, reassembling of alternator, bringing back to the sight refixing and installation and foundation with proper alignment, testing and commissiong complete all as specified and as directed by Engr-in-Charge. Note :- Price for taking the alternator up and down from the site to workshop alongwith the price for vehicle and labour are deemed to be included in the quoted rates.
Description all as per Sl item No.75 here-in-before but of capacity 100 KVA Notes for Sl item Nos. 1 to 76: (a) Daily Collecting the complaints from the Department/ Engr-in-Charge is responsiblity of Contractor. After collecting Complaints from Complaint Register/Site order Book or Insturction by JE by Phone/SMS, complaint should be completed within 48 Hours of complaint receiving. Complaints with financial implications upto Rs.15,000.00 Rupees items shall be completed with in 03 Days and above Rs. 15000.00, with in 10 Days (Including Holiday). If complaints are not attended in stipulated time period, double the rate of respective item will be recovered. (b) Minimum 01 Technician with 01 Nos helper (with all tools, and testing materials, ladder as per the site requirement) shall be always employed (with police verification of both Technician and helper) and attendance Register will be maintained by contractor to complete the complaints. Amount @ of Rs 500.00 per day for Technician and Rs 350.00 per day for helper will be recovered, If Technician/Helper are not employed in three Islands i.e. Kavaratti , Minicoy & Androth Islands.
(c) Documents required for complaints like Stationery, Complaint Register, Slips etc... shall be provided by the contactor. (d) These items will be operated only if found necessary at site during the maintenance period. The contractor has no claim over the operation of full amount / spares under these items and payment will be made only for the spare parts actually replaced at site and as per the agreed rates. (e) Major spares of DG Set will be measured and paid seperately under relevent item of the Schedule.
(f) Technician will visit each DG Set quarterly for routine checkup/servicing on date fixed (or) as and when required (in case of break down of DG Set). (g) Minor spares like nuts/bolts, washers, oil seal, gaskets, cotton waste, clamps shall deemed to be included in the job. (h) One qualified technician and helper along with tools must be provided by the contractor in each Island.
R.K. Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .