Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹44.8 L+₹5.6 L (14.3%)Rejected-AOC 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-AOC Being L2 bidder | |
| 3 | L3₹53.6 L+₹14.4 L (36.8%)Rejected-AOC | L3 | Rejected-AOC Being L3 bidder | |
| 4 | Rejected-Technical 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | - | Rejected-Technical Being not enlisted in respective category. | |
| 5 | Rejected-Technical ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | - | Rejected-Technical Being not enlisted in respective category. |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
8 Jul 2024, 6:00 pmClosed
Shri Ankur Lohiya, IDSE
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH SANGRUR ROAD PATIALA CANTT
As per tender documents
2024_MES_658818_1
GE(S)/PAT/T-24/2024-25
Open Tender
Civil Works
Item Rate
240 days
Patiala
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹96,000
Yes
1 Oct 2024
10 Jun 2024
10 Jul 2024
10 Jun 2024
8 Jul 2024
24 Jun 2024
10 Jun 2024 - 17 Jun 2024
Amount
'Notes: (i) Please refer Schedule 'A' Notes of tender documents.
AIR CONDITIONER WINDOW TYPE/SPLIT TYPE M&L for Servicing of installed Window type Air conditioner of any make 1.5/2.00 TR ton capacity including taking down , dismantling from grill , taking out air conditioner, removing all electrical components, cleaning the AC coils & fin using bubble method by applying chemical solution, cleaning with brush, washing with pressure water, oiling/greecing moving parts and reassembling complete all as specified and directed. Note :- Various check to be doneduring servicing of Window type Ac 1.5/2.0 TR and spares/items required for replacement of unsv spare/item will be measured under relavant items.
M&L for Servicing of installed Split Air conditioner of any make 1.5/2.0 TR capacity indoor and out door units including taking down , dismantling from grill , taking out air conditioner , removing all electrical components, cleaning with brush , condenser, washing with presure water , oiling moving parts and reassembling complete all as specified and directed. Note :- Various check to be doneduring servicing of Split type Ac 1.5/2.0 TR and spares/items required for replacement of unsv spare/item will be measured under relavant items.
Carrying out gas leakage check and rectifrying /arresting the same by brazing and recharging refrigerant gas, comissioning and testing to entire satisfaction of Engr-in-charge for 1.5/2.0 TR capaity Window/Split AC complete all as specified and directed.
Recharging of Refrigerant Gas F-22 complete including testing of leakage and testing the AC unit of any capacity and type for satisfactory performance complete all as specified and directed.
Supply and replacement of defective front grill decorative suitable for window type AC's 1.5/2.00 ton capacity of any make such as LG/Videocon/Voltas/FEDDER LLOYED / BLUE STAR / CARRIER etc as per the original/existing model of air conditioner complete all as specified and directed.
Supply and replacement of operating knobs of window type AC's of any make of make and model as per the existing model/size complete all as specified and directed.
Supplying and replacement of air filter as per original sample complete all as specified for AC's 1.5/2.0 Ton of any type/any make all as directed by Engineer-in-Charge complete all as specified and directed.
Taking down unserviceable Air Conditioner cap. 1.5/2.0 ton from any posn. and removing unserviceable burnt sealed unit ( compressor ) from AC and S & Fix new compressor unit rotary /reciprocating type and testing on required pressure and installing at its original posn complete all as specified and directed. Note : Cost of filling with refrigerant gas is included in unit rate of this item.
Disconnecting & Taking down unserviceable Automatic Voltage Stabilizer 4/5 KVA rating (provided for AC only. Checking & Reair of Operating Relays, Timer Relay, Relay Coil & its coneections, PCB Circuit Board, Rectifier circuit, Copmarators, Switching Circuit, Transformer, high/low voltage output fault. Installing at its original position after repair and testing all as specified and directed. Note :- Major Items for repair will be measured under relavant items.
Supply in replacement of set of Relay 04P. Relay 25 Amp - Qty 04 Nos & 01P. Relay 25 Amp (12volts)-Qty 01 No complete all as specified and directed.
Supply in replacement of Timer relay for 1.5/2.0 TR AC complete all as specified and directed.
Supply in replacement of Auto Swing Synchronous Motor having 5-6 rpm, 230 Volts, 50 Hz, 3 W suitable for 1.5/2.0 TR AC complete all as specified and directed.
Supply in replacement of Blower/Condensor Fan PVC body matching to existing blower, suitable for window type AC 1.5/2.0 TR complete all as specified and directed.
Supply in replacement of Blower/Condensor Fan 708/102 mm PVC body matching to existing blower, suitable for Split type AC 1.5/2.0 TR complete all as specified and directed.
Supply in replacement of Capacitor AC 40-45 mfd matching to existing rating capacitor, suitable for compressor of window AC 1.5/2.0 TR complete all as specified and directed.
M&L for checking of unsv PCB board of window/Split type AC 1.5/2.0 TR for cleaning of PCB by applying cleaning solution, testing of circuits, replacement of transistor/IC's, soldering work, AC to DC converter etc. and assembling the same after testing and working satsfactory to the engr-in-charge complete all as specified and directed.
Supply in replacement of remote of original company suitable to existing one or match to Split/Window AC, complete all as specified and directed.
WATER COOLERS M&L for Servicing of installed Water Cooler of capacity 40/40, 40/80 & 150 Ltr of any make including taking down, dismantling from any position, disconnecting all electricl/water connections, testing of compressor functionability, testing for gas leakage/arrest of leakage, pressure of refrigerant, testing of Fan Motor, checking of flexible drain pipe, water inlet/outlet PVC pipe, checking of float valve, checking of Thermostate, operating knobs & Copper Capillary tubes, Cleaning of Cooling Coils & Fin using Bubble method by applying chemical solution, cleaning with brush, washing with pressure water, oiling/greecing of moving parts and reassembling the same complete all as specified and directed. Note :- Various check to be done during servicing of Water Cooler any type any capacity and spares/items required for replacement of unsv spare/item will be measured under relavant items.
Taking down unserviceable water cooler 40/80 litre cap from any posn and removing unserviceable burnt sealed unit ( compressor ) from water cooler and S & Fix new compressor unit and testing on required pressure and installing cooler at its original posn. all as spec ified and directed. Note : Cost of filling with refrigerant gas is included in unit rate of this item.
Taking down unserviceable water cooler 120/150 litre cap. from any posn. and removing unserviceable burnt sealed unit ( compressor ) from cooler and S & F new compressor unit and testing on required pressure and installing cooler at its original posn. all as spec ified and directed. Note : Cost of filling with refrigerant gas is included in unit rate of this item.
Supply & replacement of thermostat switch suitable for water coolers including knobs, plate and screws for 40/80/120/150 ltr capacity complete all as specified and directed.
Supply and replacement Running Capacitor suitable for water cooler 40/80/150 ltr capacity complete all as specified and directed.
Supply & replacement of starting relay assembly including replacement of cover and clips suitable for water coolers of capacity 60/120/150 ltr complete as as specified and directed.
Supply & replacement of starting relay assembly including replacement of cover and clips suitable for water coolers of capacity 40/80 ltr complete as as specified and directed.
Supplying and replacement of Over Load Protection Relay for Water cooler 60/120/150 litre cap. complete all as directed.
Supplying and replacement of Over Load Protection Relay for Water cooler 40/ 80 litre cap complete all as specified and directed.
Supplying and replacement of Starting Capacitor for Water Cooler 120/150 litre cap complete all as specified and directed.
Supplying and replacement of Starting Capacitor for Water Cooler 40/80 litre cap complete all as specified and directed.
Taking down unserviceable Fan Motor of Water Cooler of 150 litres capacity and rewinding with suitable size of super enamelled copper winding wire including replacement of bushes, rubber mounting , clips and commissioning and testing complete all as specified and directed complete all as specified and directed.
Taking down unserviceable fan motor of water cooler of 40/80 ltr capacity and rewinding with suitable size of super enamelled copper winding wire including replacement of bushes, rubber mounting, clips and commissioning and testing complete all as specified and directed complete all as specified and directed.
Taking down old unserviceable Fan Motor & S&F new Fan Motor suitable for water cooler of cap 40/80 ltrs capacity
Taking down old unserviceableFan Motor of Water Cooler 120/150 Ltr. S&F new fan motor suitable for the same Water Cooler. NOTE : All items retrieved from this sec of sch. shall be property of contractor and contractor shall lafford credit for this account as per sch of credit.
Supply and replacement stainless steel water tap 15 mm dia, pressing type, self releasing, chromium plated push cock heavy duty (as per existing) complete all as specified and directed.
Cleaning of water cooler body of capacity 40/40, 40/80/150 ltrs internally and externally including scraping and removing all scales and dirt etc. Repair to body to stop leakage and replacing unserviceable screws, nut & bolts etc. spray painting of water cooler with synthetic enamel paint hammer tone paint including prepairation of surfaces and applying red oxide primer complete all as specified and directed.
Supplying and replacement PVC flexible copper cable 3 core 40/0.0076 length complete all specified and directed.
Recharging of Refrigerant Gas F-22 complete including testing of leakage and testing the Compressor of Water Cooler of any capacity and type for satisfactory performance complete all as specified and directed.
Supply in replacement of Stailless Steel Basin Tray of water Cooler 40/80/150 Ltr complete all as specified and directed.
Supply in replacement of Drain pipe flexible of size 1.5 inches long upto 1.5 mtr suitable for 40/80/150 Ltr capacity water cooler complete all as specified and directed.
Supply in replacement of Water Inlet PVC pipe of 15 mm size including connecting to the water supply point to water cooler storage tank inlet point & ensure for no leakage of water from both points, suitable for 40/80/150 Ltr capacity water cooler complete all as specified and directed.
Supply in replacement of Float Ball & Valve Assembely matching to the existing unsv float Ball & Assembely including fixing suitable for 40/80/150 Ltr capacity water cooler complete all as specified and directed.
Supply in replacement of Copper Capilary tube of dia 0.026 mm upto 8 to 10 feet length including High/Low Pressure convertor device, matching to the existing unsv device & capilary tubes including fixing suitable for 40/80/150 Ltr capacity water cooler complete all as specified and directed.
REFRIGERATORS/DEEP FREEZERS M&L for Servicing of installed Refrigerator 180/200/250/280/300/310/315 Ltr capacity and Deep Freezer of capacity 320 Ltr of any make including taking down, dismantling from site, disconnecting all electricl connections, testing of compressor for functionability, pressure of refrigerant, checking of Thermostate, operating buttons, testing of PCB Board & Copper Capillary tubes, Cleaning of Condensor Coils from inner side using Bubble method by applying chemical solution, cleaning with brush, washing with pressure water, oiling/greecing of moving parts icludingprovinding minor nut/screws et.c and reassembling the same complete all as specified and directed. Note :- Various check to be done during servicing of Refrigerator & Deep Freezer any type any capacity and spares/items required for replacement being unsv will be measured under relavant items.
Taking down unserviceable Refrigerator 300/310/315 Ltr capacity from the site and transporting to workshop for repair, removing unserviceable burnt sealed unit (compressor) from the refrigerator and supply & fix new compressor including testing on required pressure and transporting back to its site and fix in original position complete all as specified and directed.
Taking down unserviceable Refrigerator 180/200/250/280 Ltr capacity from the site and transporting to workshop for repair ,removing unserviceable burnt sealed unit (compressor) from the refrigerator and supply & fix new compressor including testing on required pressure and transporting back to its site and fix in original position complete all as specified and directed.
Taking down unserviceable Deep Freezer 300/320 Ltr capacity from the site and transporting to workshop for repair ,removing unserviceable burnt sealed unit (compressor) from the refrigerator and supply & fix new compressor including testing on required pressure and transporting back to its site and fix in original position complete all as specified and directed.
Recharging of Refrigerant Gas R-134A complete including testing of leakage and testing the Compressor of Refrigerator/Deep freezer of any capacity and type for satisfactory performance complete all as specified and directed.
Supply in replacement of Copper Capilary tube of dia 0.031 mm having lenth upto 8 to 10 feet including High/Low Pressure convertor device, matching to the existing unsv device including fixing of the same suitable for 310/315/320 Ltr capacity Refrigerator/Deep Freezer complete all as specified and directed.
Supply & Fixing as in repairs of Refrigerator door (plastic) complete with tension spring as per original complete all as specified and directed.
Supply & Fixing as in repairs of 320 Ltr acpacity Deep Freezer door (Plastic) complete with tension spring as per original complete all as specified and directed.
Supply & Fixing as in repairs lce Tray plastic complete all as specified and directed.
Supply &Fixing as in repairs fruit/ vegitable Tray as per original complete all as specified and directed.
Supply & Fixing as in repairs fruit/vagitable Glass cover complete as per original. complete all as specified and directed.
Supply and replacement of pigmy Lamps (bulb) of refrigerator complete as per existing complete all as specified and directed.
Supply & Fixing as in repairs Refrigerator door seal (gasket)/flexible elastic strip attached to the outer edge of refrigerator or freezer compartment in the Refrigerator/Deep Freezer of cap 180/310/315/320 Ltr complete all as specified and directed.
Supply & Fixing as in repairs door megmetic gasket complete as per original make for refrigerator 300/310 ltr capacity complete all as specified and directed.
Supplying and replacement Relay Box type for 310/315 Ltr capacity refrigerator complete all as specified and directed.
Supplying and replacement of Over Load Protector Single Phase 230 Volts, 50 Hz suitable for Refrigerator/Deep Freezer 180/300/310/315 Ltr capacity complete all as specified and directed.
Supplying and replacement of door lock with two keys as per original specification for Refrigerator 180/310/315 Ltr complete all as specified and directed.
Supplying and replacement of drian water Collector container made of PVC suitable for Refrigerator 180/300/310/315 Ltr Capacity complete all as specified and directed.
Supplying and replacement of Copper Filter Drier in Refrigerator 180/310/315 Ltr capacity complete all as specified and directed.
Disconnecting & Taking down unserviceable Automatic Voltage Stabilizer upto 2 KVA rating connected to Refrigerator/Deep Freezer/Water Coolers. Carry out repair to Operating Relays, Timer Relay, Relay Coil & its connections, PCB Circuit Board, Rectifier circuit, Copmarators, Switching Circuit, Soldering work, Transformer, high/low voltage output fault. Installing at its original position after repair and testing all as specified and directed. Note :- Cost of spares/parts required to be replacement will be included in quoted rate.
Supplying and replacement of voltmeter of range 0-500 volts single phase 230/240 volts, 50 Hz suitable for Refrigerator/Deep Frizeer 180/310/315 Ltr capacity complete all as specified and directed.
Supplying and replacement of Indian Thermostate for single door/double door Refigerator 180/310/315 Ltr/Deep Freezer 320 Ltr as per existing rating of thermostate compatible for Voltas/Samsung/Usha/Blue Star/Kelvinator/Godrej/Whirlpool complete all as specified and directed.
Taking down desert cooler fixed at any position cleaning internally and externally by scraping all scales dirt etc and repair to desert cooler to stop any type of leakage, tightening & replacing of screws, nuts and bolts etc all as directed including painting of desert cooler with spray machine with synthetic enamel hammer tone paint over one coat of red oxide primer and refixing of the desert cooler after necessary oiling and greasing of fan and water lifting pump complete all as specified and directed.
Supply and replacement of water lifting pump, 230 volt 50 C/S single phase suitable for desert coolers complete all as specified and directed.
Supplying and replacement wood wool pads of suitable size and providing wire netting of GI wire 1.4 mm dia 25 mm mesh for holding pads complete all specified and directed.
Supplying and replacement high density polythene pipe 15 mm dia for desert coolers complete all specified and directed.
Supply and replacement of capacitor 4 mfd suitable for desert cooler complete all as specified and directed.
Dismantling and taking out old, unserviceable fan motor from the desert cooler and rewinding with supper enamel winding copper wire of suitable size varnishing etc including replacement of bushes, bearings, washers etc. and assembling testing and refixing in existing position all as specified and directed.
Supply and replacement complete steel body of desert cooler of capacity 4000 cft with front grill and side & back panels duly spray painted with synthetic enamel hammer tone paint over one coat of red oxide primer including dismantling and refixing the old parts i.e fan motor, pump etc in new body, replacing the defective wires, PVC pipes and water distributor, making connections and testing complete all as directed. The body of desert cooler will be fabricated as under :- (a) The top and bottom made out of 1.25 mm thick GI sheet. (b) Side panels (set of three) made out of 1.00 mm thick GI sheet. (c) Front grill of suitable size and of approved quality.
Supply & replacement Air direction grill only made of iron suitable size of desert cooler all as specified and directed.
Supply & replacement Single Phase, Neutral & earth wiring copper cable of size .5/1.0 sqmm of deset cooler from fan motor to regulator, pump to control switches complete all as specified and directed.
Supply & replacement of regulator knob type switch, 3 step control of speed of Desert cooler motor 230 volts, 50 Hz complete all as specified and directed.
Supply & replacement of switch piano type 5 Amps suitable for desert coolers complete all as specified and directed.
Supply & replacement of exhaust fan motor holding clamps made out of iron of suitable size all as specified and directed.
Supply & replacement of exhaust fan motor holding ring made out of iron of suitable size all as specified and directed.
Supply & replacement of side & rear panes (1.0 mm GI sheet) made of iron of suitable size for desert cooler all as specified and directed.
Supply & replacement PVC Fan Blades of superior quality (having 3 branches) including fixing to the desert cooler motor all as specified and directed.
Dismantling and taking out serviceable solar power plant of capacity 25 KW and shifted to new location as decided by users / GE (S) Patiala with all necessory nuts ,bolts,anchor bolts and civil works like PCC , grouting of angle iron into PCC and make the solar plant as similar as existing service including disconnecting of electrical connections and conneted the same complete all as specified and directed. Note :- Payment shall be made after proper satisfaction of users / GE ( S ) Patiala
Day to day complaints of street lights of various type for working height varies from 9m to 15m in the juridiction of AGE E/M, GE (S) Patiala within 8 km radious incl removing carbon from LED light connection by deploying dedicated team having the experience in the same field. Contractor has to provide all required Tool and plants for street light fault rectification. Contractor will make record of all given complaints and rectified complaints updated on daily basis. Street light complaints should be rectified within 24 hrs after intimation via any communication mode. If the comaplint is not rectified within stipulated time contractor will bear penality of Rs 200 per day per complaint. Note :- (i) Necessary suitable vehicle shall be contractors own arrangement for carrying man power, tools and store. (ii) One repair/replacement of street light shall be counted as one job. (iii) The complete arrangement ie. veh, manpower tool and plants is enclusive in this quoted rate.
Supply and fix in replacement electronic driver with power factor correction suitable for 35/45/60 Watt LED street lights, input AC 85-300V, input frequency 50/60 Hz, output voltage DC 22-38V, output current 1500mA (+-) 5%, waterproof level :IP 65, shell material : aluminium with IS 15885, complete all as specified and directed.
Supply and fix in replacement electronic driver with power factor correction suitable for 70/90/120 watt LED street lights, input voltage 70V AC to 300 V AC , power factor 0.99 (Unity) , over voltage 300 V cutt off , short and open circuit protection isolated, surge protection up to 10 to 12 Kv, maximum output voltage 55 Kv, maximum current up to 1.5a waterproof level :IP 65, shell material : aluminium with IS 15885, complete all as specified and directed.
Supply and fixing LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 66 protection complete, all as specified and directed.
All as item No. 3 Above but of size 90 Watt.
All as item No. 3 Above but of size 70 Watt.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete including connecting to junction box and fixing of light fitting to existing GI bracket painted in silver colour & steel clamps complete with accessories suitable for fixing to the RCC LT Pole of 9 mtr complete all as specified and directed.
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete including connecting to junction box and fixing of light fitting to existing GI bracket painted in silver colour & steel clamps complete with accessories suitable for fixing to the RCC LT Pole of 9 mtr complete all as specified and directed.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete including connecting to junction box and fixing of light fitting to existing GI bracket painted in silver colour & steel clamps complete with accessories suitable for fixing to the RCC LT Pole of 9 mtr complete all as specified and directed.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, all as specified and directed.
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, all as specified and directed.
Supply and fixing in repair of automatic street light control switch single phase 5-8 KW 40 Amps using infrared sensor based nature switch for automatic switching of street lights. Nature switch operation should be based on Natural light lux level. The sensor along with suitable power contactors and incoming out going MCBs should be enclosed pole/wall mounted thermo plastic polycarbonate enclosure conforming to IP 66 protection class 2 complete all as specified and directed.
Supply and fixing post top lantern LED type 36/40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. and incl cost of masonary work for fixing of light on gate pillars on suitable size GI tubing duly silver painted incl colouring/white wash of masonary surface for matching of existing colour/surface all as specified & directed.
Supply and fix in replacement integrated auxiliary contactor 65 Amps, AC 3 phase, 220 to 415 volt, 50/60 Hz, three/four pole, contacts 2NO+2NC conforms to IEC/EN -60947-4-1 suitable for street light timer panels, complete all as specified and directed.
Supply and fix in replacement integrated auxiliary contactor 40 Amps, AC 3 phase, 415 volt, 50/60 Hz, three pole contacts 1NO+1NC conforms to IEC/EN -60947-4-1 suitable for street light timer panels, complete all as specified and directed.
Supply and fix in replacement street light panels analog time switch (with battery back up), 3P Module, 24 hours program, programmable every 15 min, current capacity 16 Amps, suitable for 63/40/32 Amps street light timer, AC 3 phase, 110-240 V AC (1CO) base/ Din 16 pulse digital time switch,complete all as specified and directed.
Supply and fixing PVC insulated copper cable 2.5 sqmm three core multistanded flexible 1100 volts complete all as specified and directed.
S & F as in replacement brackets 1.2 m long made to shape fabricated out of GI pipe Light grade ISI marked 40 mm dia incl provn of socket nipple welded at once end to suit the light fitting and fix to pole including clamps with nuts and bolts of suitable size cutting, drilling and welding its fix to pole and applying two coat of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Supply and fixing of MCB 6 A to 32 Amps,240 Volts single pole fix in position where directed, complete all as specified and directed.
Suppy and fix rigid non-metallic PVC conduit medium grade 20 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
M&L Dismantling the alternator of DG set of capacity 160 KVA from its base by using chain and pulley after removing the coupling with the engine, removing all nut, bolt with washer and all electrical connections of the alternator, shifting the alternator to work shop by crane and vehicle, opening into parts, checking all winding like main stator/rotor winding, exciter stator/rotor winding. Rewinding the main rotor and exciter rotor by using the "F" class insulation and existing gauge and type of magnet wire that was on the original motor, varnishing, heating, drying, greasing the bearings including replacement of unserviceable bearings, Re-fixing the complete including connection to the terminal box of the alternator at work shop and shifting the same to the site, Fixing the alternator to its base carefully by using chain and pulley, connecting it with existing engine including checking the alignment of alternator with the engine, connecting all electrical connections of the alternator and testing the DG set on "OFF/FULL LOAD", matching to the existing range of RPM of the engine, out put voltage 415 volt and testing all as per the direction of the Engr-in-charge.
Taking down self starter assembly of DG set of capacity 62.5 /160 KVA, 12 volt / 24 Volts from the existing position, opening in to parts, sort out the unserviceable items like carbon brush, pinion etc. and replace the same with new one including rewinding of field coils, re-assembling and re-fixing the same in its original position including to and fro conveyance charges to work shop and testing and all as per the direction of the Engr-in-charge.
Dismantling fuel injection pump (FIP) of DG set carefully from 62.5 to 160 KVA, opening in to parts, for maintenance, servicing, tuning by overhauling and calibration up to 6 cylinders, adjustment of nozzle pressure and other controls, replacement of unserviceable spares, re-fixing the FIP on its original position including to and fro charges to thr work shop and all as per the direction of the Engr-in-charge.
S&F Single Phase SMC Junction box suitable for mounting on LT RCC pole of 9 mtr long, box having Al busbar 20 Amp rating with 6 Amp MCB ('B' series) control, mounted on insulators with 2 clamps of copper strip for earthing of the armoured of the cable complete with making holes for connecting cables etc nuts bolts etc front openable hinged cover suitable for mounting on steel clamps nut bolt etc pvc adopters and PVC hose pipe upto cable trench for incoming and outgoing cables, factory made duly painted with powder coating process complete all as specified and directed.
Supply & install in repair Lead Acid Battery 12 V 150 AH complete all as specified and directed.
Supply and replacing AVRs unit of alternator of DG Set 62.5 to 160 KVA capacity as per existing type and model and all as per the direction of the Engr-in-charge.
Supply and erecting in replacement LT PCC pole 9 Mts long cross sectional area 102 mm x 172 mm at top and 102x279 mm at bottom class 10 complying with requirement of relevent IS and painting the pole upto 5 feet from ground level with black and yellow alternate strip of 30 CM each with synthetic enamel paint incl removing of broken pole debris complete all as specified and directed. Note:- (i) After commissioning of new pole contractor would liable to connect all the ACSR conductors to the new pole including insulators and cross arms etc inclusive in this unit rate. (ii) Excavation ,PCC shall be measured and paid separately.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1,5 mtr in depth for laying of cables errecting of pole including getting out in any kind of soil complete all as specified and directed.
All as per item no. 109 as above but exceeding more than 1.5 m in depth.
Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil complete all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M &l for PCC 1:4:8 TYPE D-2 using 40 mm graded broken stone aggregate as in mass concrete in foundations etc . complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 using 20 mm graded broken stone aggregate as in mass concrete in foundations etc complete all as specified and directed .
Material and labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for coping around the pole strut above ground level, foundation of stay etc. including neccassory form work and finishing the surface fair and even without using extra cement all as directed and specified.
Supply,laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 10 sqmm 4.0 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note :-(i) Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately.
All as per item No. 116 here-in before but for cable of size 4 core 16 sqmm.
Clean dry sand laid in trenches/ducts for bedding and cushioning to cable, including spreading and leveling complete all as specified and directed. Note:-(i) Consolidated/punned sand shall be considered for purpose of payment.(ii) Sand shall be same as specified for plastering work.
M & L for B bricks of old size laid dry in trenches for cable protection all as specified and directed by Engineer in Charge.
M & L for MCCB ,4 Pole 63 Amps complete all as specified and directed.
M & L for MCCB ,4 Pole 40 Amps complete all as specified and directed.
REPAIR TO GEYSER WORKS Attending of day to day complaints of geysers by draning out the water and taking down carefully from wall after unscrewing nut/bolts geyser 50/35/25 Ltr capacity and opening the same for taking out internal tank, syphon assembley etc including replacement of defective unserviceable parts, reassembling and refixing after repair all as specified and as directed by Engr-in-Charge. Note: i) Spares shall me measured and paid sepratley under respective items of Sch. ii) Penal charges of Rs 250 per day per complaint shall be imposed on contractor for not attending the complaint within 24 hrs. (iii) One Electrician and One helper will attend the complaints ( One Electrician and Two helder payment will be deemed in item rate only )
Supply only heating unit (element) 240 volt AC ISI marked of 1500 watts Circular/triangular shape rating as required at site including rubber washers complete, all as specified and as directed.
Supply only heating unit (element) 240 volt AC ISI marked of 1500 watts special type suitable for Bajaj / CG Geyser ( as per sample ) shape rating as required at site including rubber washers complete, all as specified and as directed.
Supply and replace thermostat switch suitable for 25/35/50 ltr geyser AC 230 volt adjustable range from 0-90 degree Celsius, complete all as specified and directed.
Supply and replace special type thermostat switch suitable for 25/35/50 ltr geyser AC 230 volt adjustable range from 0-90 degree Celsius for Bajat/CG Gerysers ( as per sample ) , complete all as specified and directed.
Supply and replacement internal steel tank of geyser 25 ltr capacity complete with syphon –assembly, 1.5 kw element , rubber gasket , thermostat switch , complete all as specified and directed . Note: The tank shall be tested at site and shall be able to with stand the requisite pressure. Necessary testing equipment shall be arranged by the contractor .
Supply and replacement internal steel tank of geyser 50 ltr capacity complete with syphon –assembly, 2.0 kw element , rubber gasket , thermostat switch , complete all as specified and directed. Note: The tank shall be tested at site and shall be able to with stand requisite pressure . Necessary testing equipment shall be arranged by the contractor .
Supply and replacement of syphon assembly made out of brass of 50 ltr capacity including necessary studs, screws and rubber gasket/washers complete all as specified and directed.
All as per Srl item No. 129 above but for 25 ltr capacity, complete all as specified and directed.
Supply and replacement outer body suitable for 50 ltr geyser made out of MS sheet factory made complete with fixing bracket matching with existing, complete all as specified and directed.
Supply and replacement outer body suitable for 25 ltr geyser made out of MS sheet factory made complete with fixing bracket matching with existing complete, all as specified and directed.
Supply and replace glass wool of 25 ltrs capacity geyser, complete all as specified and directed by Enginner-in-Charge.
All as per Srl item 133 here in before but in 50 ltrs capacity geyser, complete all as specified and directed by Enginner-in-Charge.
Supply and replace indicator lamp round/square type suitable for geyser 25/50 ltr all as per sample AC 230 Volt, complete all as specified and directed by Enginner-in-Charge.
Supply and replace PVC connection 15mm dia 60 cm long complete with brass flair nuts at both ends. ( ISI marked and suitable for hot water supply upto 100 degree celcius), complete all as specified and directed by Enginner-in-Charge.
Supply and replace PVC connection 15mm dia 90 cm Longcomplete with brass flair nuts at both ends. ( ISI marked and suitable for hot water supply upto 100 degree celcius), complete all as specified and directed by Enginner-in-Charge.
Supply and fixing anchor bolt 12mmX100mm long complete all as specified and directed (Note:- Anchor bolt shall be grouted with hammer drill only)
Supply and fixing in replacement of defective mild steel base plate cup any type with screws of suitable size as per requirement complete, all as specified and as directed.
Supply and fixing in replacement of 15mm stop valve CP fancy type,cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe unions and suitable, complete all as specified and directed by Enginner-in-Charge.
Supply and fixing in replacement of 1100 Volt grade cable flexible 3 Core PVC insulated PVC sheathed with stranded copper conductor of size 2.5 sqmm, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement of CP connection brass with flair nuts all as per sample, complete all as specified and directed.
Cleaning / scrapping of old paint/dust and painting of geysers of 25/35/50 litres capacity at site/ stores with two coat of super enameled painting by spray, complete all as specified and as directed.
Supply and fixing in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement of mild steel galvanised iron water tubing 15mm bore with screwed & socket joints, medium grade, in short lenghts, with and including all fittings such as sockets, bends, elbow, unions, tees, diminishing pieces etc, fixed to wall or ceiling or in floor complete all as specified and directed.
Supply and fixing plug top 15 Amp three pin for geysers, complete all as specified and directed.
S&F in repair Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of size 15mm dia, complete all as specified and directed.
M&L in repair for point wiring with 2.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC conduit ( ISI Marked) with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and directed. Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost. ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.
REPAIR TO SOLAR WATER HEATING SYSTEM Attending of day to day Solar Water Heating System complaints taking down, opening up, reassembling, refixing and testing of Solar Water Heating System including replacement of unserviceable parts wherever required at the discretion of the Engr-in- Charge shall be carried out by the contractor for efficient functioning of Solar Water heating System. The cost of material will be measured and paid seperately for replalacement of parts complete all as specified and directed. Note: (i) Schedule of repair to Solar Water heating System is catered for attending day to day complaints of different items within the prescribed time schedule as decided by the EIC on complaint slip, failure to attend the complaint within the prescribed time shall attract a penalty of Rs 250 per day per complaint. Note: All repair to Solar water heating system shall be carried out from an authorized person of the manufacturer of the system and proof there of shall be produced to the GE before undertaking repairs. Contractor is advised to visit the site to ascertain the model and manufacturer of system before quoting his rates.
Supply and replacement solar flat plate collector having collection area not less than 2.0 sqm made out of aluminium frame and toughened glass suitable for solar panel system complete all as specified and directed.(As per sample )
Supply & fix in repairs Heating element, 3 KW, ISI marked, copper sheathed, nickel plated suitable for any type, make, size of solar water geysers, complete all as specified and directed.
Repairs to existing MS framed supports to SS water tank of solar heating system of capacity 100/200/300 LPD by welding , provinding necessary MS pieces to strenghthing the frame, complete all as specified and directed.
De scaling of solar water heater complete of 100/200/300/500 LPD capacity with 02 Nos solar panel using suitable chemical including unsv nut bolts washer etc complete all as specified and directed.
M&L for preparing new surface of steel of any description and applying two coats of synthetic enamel paint over a coat of red oxide complete all as directed and specified.
Supply and fix electric water heater, storage type steel body with S/S inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all connecting accessories such as safety valve, thermostate, NRV, PVC/CP connection pipe of superior qualitysuitable for hot & Cold water including hanging/fixing the same on wall with suitable size anchor bolt and making good the disturbed surface including plaster work shall be part of job at no extra cost all as specified and directed by Engr-in-Charge. Cat No-GHWAFATWB025 of Havells or equivalent make mentioned here-in-after.
SWAMI ENGINEERS (BID ID -3054143)
BANSAL ENGINEERING (BID ID -3052184)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .