| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 19 2 2ND FLOOR INDRA VIKAS COLONY NORTH WEST DELHI DELHI 110009 | NORTH WEST DELHI | DELHI | 110009 | Accepted-Technical OK |
| 2 | Accepted-Technical 01 DURGA ENTERPRISES KAKROLA MAHENDRAGARH HARYANA 123027 | MAHENDRAGARH | HARYANA | 123027 | Accepted-Technical OK |
| 3 | Accepted-Technical OPP BAHADURA SWEETS NAYA BAZAR LASHKAR GWALIOR | Accepted-Technical OK |
| 4 | Accepted-Technical B 748 ANAND NAGAR BAHODAPUR GWALIOR | Accepted-Technical OK |
| 5 | Accepted-Technical KAJI PURA WARD NO 10 MUNGAOLI ASHOKNAGAR | MUNGAOLI | ASHOKNAGAR | Accepted-Technical OK |
Tender Value
₹70 L
EMD Value
₹70,000
Closing Date
4 Dec 2025, 3:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GM O n M Circle Office Sheopur
GM Circle Office Sheopur
Rate Contract Award for Supply of Local Purchase items for Operation and Maintenance of Various equipment and Various Safety Material for ONM Divisions and STM STC Division Situated under General Manager (O N M) MPMKVVCL Circle Sheopur.
2025_MKVVC_462281_1
GM/ONM/SHEO/PUR/25-26/51/3724
Open Tender
Electrical Goods/Equipments
Item Rate
180 days
GM Circle Office Sheopur
Refer Tender RCA Document
3 documents required · 3 mandatory
₹5,900
Yes
₹70,000
Yes
26 Dec 2025
12 Nov 2025
5 Dec 2025
12 Nov 2025
4 Dec 2025
12 Nov 2025
Trip Coil Shunt 30 Volt DC Suitable for 33 kv VCB make – Stelmec
Trip Coil Shunt 30 Volt DC Suitable for 33 kv VCB make – CGL
Trip Coil Shunt 30 Volt DC Suitable for 11 kv VCB make Shreem
Trip Coil Shunt 30 Volt DC Suitable for 11 kv VCB make CGL
Trip Coil Shunt 30 Volt DC Suitable for 11 kv VCB make - BHEL
Trip Coil Shunt 30 Volt DC Suitable for 11 kv VCB make ERL
Trip Coil Shunt 30 Volt DC Suitable for 11 kv VCB make Alstrem
Trip Coil Shunt 30 Volt DC Suitable for 11 kv VCB make Schenider
Trip Coil Shunt 30 Volt DC Suitable for 11 kv VCB make Stelmec
Trip Coil Shunt 30 Volt DC Suitable for 11 kv VCB make C&S
Trip Coil Shunt 30 Volt DC Suitable for 11 kv VCB make - S&S
Closing Coil Shunt 30 Volt DC Suitable for BHEL make VCB
Closing Coil Shunt 30 Volt DC Suitable for Crompton make VCB
Closing Coil Shunt 30 Volt DC Suitable for Essun make VCB
Closing Coil Shunt 30 Volt DC Suitable for Megawin make VCB
Closing Coil Shunt 30 Volt DC Suitable for Stelmec make VCB
Closing Coil Shunt 30 Volt DC Suitable for Areva make VCB
Expulsion Fuse 40 Amp. (T-40) For Capacitor Bank
Expulsion Fuse 60 Amp. (T-60) For Capacitor Bank
Digital Clamp Meter Tong Tester (0-750 Volt AC 1000 Amp. AC) Make- Mexo/Motwane
Megnatic Oil Gauge for power transformer (MOG) 6 inc dia with lead
Spring Charging Motor Suitable for 11 kv VCB Make-BHEL
Spring Charging Motor suitable for 11 kv VCB Make - Crompton
MFM suitable for Control panel of all makes.
Buchholz Relay(Gas & oil Operated) (IS 3637) Flenge-6 inch
GI Nut Bolt assorted Size
“Tool Kit with Box specification having per kit 1-De spanner set of 10 pieces No. 6X7 to 24X27 2-Ring spanner set of 10 pieces No. 6X7 to 24X27 3- Cutting Pliers (8”) 01 No 4-Nose Pliers (6”) 01 no 5-Pipe wrench adjustable (12”) 01 No. 6-Hammer 01 No. 7-Hexa with blade 01 No. 8-Screw driver (06”) 01 no. 9-Screw driver (08”) 01 no. 10-Screw driver (10”) 01 no 11-Screw driver (12”) 01 no 12-Wrench Pana 13-Chisel 01 No ” Make Tapariya/Venus
11 kv Insulated pull rod suitable for BHEL Make VCB with Copper shunt
Piercing connector Type I for single phase/Three Phase suitable for 70-150 sq mm cable
Raincoat(Rubberisied) with cap Make Duckback
Bamboo ladders 24’ (feet) Long approx having 2” to 3” Dia at the Bottom and 1.5”to 2.5” at top of Bamboo the Cross Piece i.e. 16 No. Step should be at a distance of approx 17” and bamboo ladder should be tightened with G.I. Wire of 16 swg at least 4 places the top of ladder should be wide 35 to 40 cm and bottom 58 to 60 cm
Silica gel (Blue)2 to 4 mesh
Breather with Silica Gel (Blue) 2 to 4 Mesh for power Transformer Capacity 5 kg
poly Propylene Rope 24mm Dia make Tuff Rope/Equivalent standered make with ISI mark.
Smart connector suitable for M-16 CT tetminal to Dog/Raccoon suitable for AI Alloy
CB Smart Clamp For Dog/Raccoon and Panthor Conductor
30 volt DC led type Indicating lamp of green/red/yellow colour
Breaker control On/Off Switch handle type suitable for control panel make-Recon/Kaycee/Any Standard
LV Brass Stud complete made of brass stud with its all accessories for 200/315 KVA distn. Transformer one set for brass stud 300 amp shall comarion of brass stud 265X20 mm 01 no. brass hexa nut full thred-01 no., brass lock nut-02 no., brass Rear nut-02no. sealing ball washer -01 (neoprene rubber washer) & brass plain Whaser-02 no Approximate weight 1050 gram -+5% tollarence.
LV Brass Stud suitable for 25/63/100 KVA X-MER Length of rod 200mm Dia 12mm, both & therder up 60 mm heaving chuck out washer & bass washer with 05 no. Nut Approximate weight 320 gram -+5% tollarence
33 KV Bushing for PTR suitable for 20 mm stud
11 KV Bushing for PTR suitable for 20 mm stud
Rubberized Cork seat 4 mm (2 X 3 Ft.)
Rubberized Cork seat 6 mm (2 X 3 Ft.)
Rubberized Cork seat 10 mm (2 X 3 Ft.)
Oil temperature indicator (OTI) , Dial 150mm , with capillary, Mercury switch type
Winding temperature indicator (WTI) , Dial 150mm , with capillary, Mercury switch type
Auxiliary Switch suitable for 11 kv VCB Make Bhel (New)
Auxiliary Switch suitable for 11 kv VCB Make Megawin
Auxiliary Switch suitable for Stealmac Make VCB
Auxiliary Switch suitable for Crompton Make VCB
11 kv Insulated pull rod suitable for BHEL Make VCB with Copper shunt
“33kv Vacuum Bottle/interrupter with pull rod (for VCB Pole) suitable for 33 kv, Stelmac Make :- VCB” . (With Test Certificate )
“33kv Vacuum Bottle/interrupter with pull rod (for VCB Pole) suitable for 33 kv, BHEL Make :-VCB” . (With Test Certificate )
11 kv Vacuum interupter suitable for VCB Make Stelmec/Crompton (With Test Certificate )
LED Street Light of 48-50 Watt(complete)Make-SHARP With 2 year replacement guaranty & pipe / clamps suitable for pole mounting
Flood Light of 200 Watt(complete) Make-SHARP With 2 year replacement guaranty & pipe / clamps suitable for pole mounting
Aluminum Lugs long barrel gripping suitable for 70 sqmm cable As per IS 8309
Aluminum Lugs long barrel gripping suitable for 95 sqmm cable .As per IS 8309
Aluminum Lugs long barrel gripping suitable for 120 sqmm cable . As per IS 8309
Aluminum Lugs long barrel gripping suitable for 150 sqmm cable . As per IS 8309
Aluminum Lugs long barrel gripping suitable for 300 sqmm cable . As per IS 8309
Transformer Repairing Rubberized Cork sheet Packing kit complete 26 No. Item- 1- Rubber conical bush HV inner Dia 12 mm 2- Rubber conical bush LV inner Dia 12mm 3- Cork Sheet washer “O” ring outer Dia 110 mm & inner Dia 75mm 4- Cork Sheet washer “O” ring outer Dia 50 mm & inner Dia 30 mm 5- Cork Sheet washer “O” ring outer Dia 30 mm & inner Dia 15mm
11kv Do Fuse Elements 3 Amp As Per ISS-9385
11 kv Do Fuse Elements 5 Amp As Per ISS-9385
11kv Do Fuse Elements 10 Amp As Per ISS-9385
11 kv Do Fuse Elements 15 Amp As Per ISS-9385
“Rubber Hand Gloves Size 14” (355mm) Joint less dully tested up 17000 volt and working potentials 7500 volt as per ISS no. 4770-1991 Make Crystal
Line man Discharge road 6 feet long Bamboo with 2.5 sqmm copper wire 6 mtr length fixed at top of bamboo 3 type copper strip size 173x19x3
Poly Propylene Rope 24mm Dia make Tuff Rope/Equivalent standered make with ISI mark.
M-Seal
Flat Type heavy duty Bi-metallic Clamp made of brass and aluminum it should have brass pad size 50 mm×50mm×10mm with 16/20 mm hole at center and aluminum on other side size 175mm×70mm×10mm having 12 nos. G.I. Nut and Bolt size 7/16×5mm with plain and spring washers for Dog conductor. Weight 1.600 kg tolerance -+5%.
Bi-Metalic clamp for DTR Brass pad size 50×50×6 mm, with 12 mm hole fitted On aluminum portion size 70x50x20 mm fitted with 06 NOSGI nut and bolt with spring washer clamp suitable for 150 sqmm PVC cable weight of clamp Weight 600 gram(Aprox +_5%)
TC Fuse Wire 14 SWG As Per IS 8130:1984
TC Fuse Wire 16 SWG As Per IS 8130:1984
ABC Powder type (Stored Pressure) fire extinguisher 9kg. Capacity. ISI Mark IS; 15683 opreating temp. (+5)0 C to (+55)0 C for class 4 A type of fire filled with MAP powder complete in all respect.
HRC fuse base 400 Amp with copper contact
HRC fuse base 250 Amp with copper contact.173x19x3
HRC fuse link 400 Amp suitable for 400 amp HRC fuse base as per ICE/ISI Standard.
HRC fuse link 250 Amp suitable for 250 Amp suitable for 250 amp HRC fuse base as per ICE/ISI standard.
Screw driver insulated plastic handle blade length 300mm (12 inch) Make- Venus/IS standard
Screw driver insulated plastic handle blade length 250mm (10 inch) Make- Venus/IS standard
Screw driver insulated plastic handle blade length 200mm (8 inch) Make- Venus/IS standard
Insulated neon tester Make- Venus/IS standard
“Insulated Cutting Plier 8” (inch). Make Tapariya, venus, jhalani or other euqivalent IS standard.”
Power Transformer Clamp
Smart T Clamp of all sizes
Smart PG Clamp of all sizes
Isolator Pad Clamp
Safety Helmet
Repairing of Numerical Relay (2OC & 1 Earth Fault)
Rechargeable Torch with 6 to 6.5 volt battery charger supply AC 240 watt
Gumboots suitable for 200 C and up to 560 C double density sole shoes Heights 11 inches ( Size – 8)
Gumboots suitable for 200 C and up to 560 C double density sole shoes Heights 11 inches ( Size – 9)
Insulated Fiber Discharge Rod 18 feet long extention ¾ section with alluminium c type clamp with wire
Line man Safety belt with Jhula
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
RCA_FOR_LOCAL_PURCHASE_PROCUREMENT_51.pdf
Tender Documents • 1.22 MB
BOQ_543583.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .