| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC | ₹9.2 L Quoted ₹9.3 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹9.7 L+₹43,894.63 (4.73%)Rejected-Finance BXXV 38 2 RAM NAGAR SAINGARH TEHSIL DISTT PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | ₹9.7 L+₹43,894.63 (4.73%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹9.7 L+₹46,052.22 (4.96%)Rejected-Finance VILL BALSUA PO JAKOLARI TEH DISTT PATHANKOT PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹9.7 L+₹46,052.22 (4.96%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹9.9 L+₹62,665.01 (6.75%)Rejected-Finance 6 GURU GOBIND SINGH NAGAR DHAKOLI DHAKOLI PATIALA PUNJAB 140602 | PATIALA | PUNJAB | 140602 | ₹9.9 L+₹62,665.01 (6.75%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹10.0 L+₹71,592.88 (7.72%)Rejected-Finance | ₹10.0 L+₹71,592.88 (7.72%) | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | JP AND CO. L4 | GANDOTRA CONSTRUCTION CO L3 | Ms Madan Gopal L2 | satpal and brothers L6 | kailu construction co L7 | D S INFRASTRUCTURE AND DEVELOPERS L1 | BALI CONSTRUCTION WORKS L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of brickwork or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work precast concrete articles complete all as specified and directed. | 1.5 | Cum | 472 ₹708 | 468 ₹702 | 463 ₹694.5 | 482 ₹723 | 486 ₹729 | 450 ₹675 Lowest | 477 ₹715.5 |
| 2.00 | M&L brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in Cement mortar 1:4, complete all as specified and directed. | 1.5 | Cum | 5,460 ₹8,190 | 5,408 ₹8,112 | 5,356 ₹8,034 | 5,565 ₹8,347.5 | 5,616 ₹8,424 | 5,200 ₹7,800 Lowest | 5,512 ₹8,268 |
| 3.00 | M&L PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed. | 0.5 | Cum | 7,560 ₹3,780 | 7,488 ₹3,744 | 7,416 ₹3,708 | 7,705 ₹3,852.5 | 7,776 ₹3,888 | 7,200 ₹3,600 Lowest | 7,704 ₹3,852 |
| 4.00 | Demolition of cement concrete unreinforced in ground floors, kota stone, granite flooring, tiles flooring and paving's not exceeding 15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed. | 15.4 | Cum | 472 ₹7,268.8 | 468 ₹7,207.2 | 463 ₹7,130.2 | 482 ₹7,422.8 | 486 ₹7,484.4 | 450 ₹6,930 Lowest | 477 ₹7,345.8 |
| 5.00 | M&L 50mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection/footh path finished the surface even and smooth without using extra cement complete all as specified and directed. | 29.96 | Sqm | 367 ₹10,995.32 | 364 ₹10,905.44 | 360 ₹10,785.6 | 375 ₹11,235 | 378 ₹11,324.88 | 350 ₹10,486 Lowest | 371 ₹11,115.16 |
| 6.00 | Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed. | 122.4 | Sqm | 47 ₹5,752.8 | 46 ₹5,630.4 | 46 ₹5,630.4 | 49 ₹5,997.6 | 49 ₹5,997.6 | 45 ₹5,508 Lowest | 49 ₹5,997.6 |
| 7.00 | M&L rendering 15mm thick plaster on stone masonry or other than fair faces of brick wall in CM 1:4 finished the surface even and smooth without using extra cement complete all as specified and directed. | 38.4 | Sqm | 357 ₹13,708.8 | 353 ₹13,555.2 | 350 ₹13,440 | 363 ₹13,939.2 | 367 ₹14,092.8 | 340 ₹13,056 Lowest | 360 ₹13,824 |
| 8.00 | M&L rendering 10mm thick plaster on stone masonry or other than faces of brick wall in CM 1:3 finished the surface even and fair without using extra cement complete all as specified and directed. | 84 | Sqm | 399 ₹33,516 | 395 ₹33,180 | 391 ₹32,844 | 406 ₹34,104 | 410 ₹34,440 | 380 ₹31,920 Lowest | 402 ₹33,768 |
| 9.00 | M&L preparation of old surface of ceiling and applying three coats of white wash on old decorated surface complete all as specified and directed. | 96 | Sqm | 19 ₹1,824 | 18 ₹1,728 Lowest | 19 ₹1,824 | 19 ₹1,824 | 19 ₹1,824 | 18 ₹1,728 Lowest | 22 ₹2,112 |
| 10.00 | M&L preparation of old plastered or unplastered surfaces of walls and applying two coats of distempering walls with distemper oil emulsion and applying plaster of paris putty of 1mm thickness over old plastered wall surfaces including prepartion of surfaces even and smooth complete all as specified and directed. | 44 | Sqm | 78 ₹3,432 | 78 ₹3,432 | 77 ₹3,388 | 80 ₹3,520 | 81 ₹3,564 | 75 ₹3,300 Lowest | 79 ₹3,476 |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
26 Aug 2025, 6:00 pmClosed
Lt Col S N Gaikwad
Holta Cantt Palampur
SPL REPAIR TO SQUASH COURT AT SAINIK SCHOOL SUJANPUR
2025_MES_723198_1
GEP-60/2025-26
Open Tender
Civil Works
Item Rate
180 days
SAINIK SCHOOL SUJANPUR
As per tender documents
8 documents required · 8 mandatory
₹500
GE Palampur
₹19,000
16 Dec 2025
29 Jul 2025
2 Sept 2025
29 Jul 2025
26 Aug 2025
12 Aug 2025
Amount
Demolition of brickwork or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work precast concrete articles complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in Cement mortar 1:4, complete all as specified and directed.
M&L PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floors, kota stone, granite flooring, tiles flooring and paving's not exceeding 15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed.
M&L 50mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection/footh path finished the surface even and smooth without using extra cement complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed.
M&L rendering 15mm thick plaster on stone masonry or other than fair faces of brick wall in CM 1:4 finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L rendering 10mm thick plaster on stone masonry or other than faces of brick wall in CM 1:3 finished the surface even and fair without using extra cement complete all as specified and directed.
M&L preparation of old surface of ceiling and applying three coats of white wash on old decorated surface complete all as specified and directed.
M&L preparation of old plastered or unplastered surfaces of walls and applying two coats of distempering walls with distemper oil emulsion and applying plaster of paris putty of 1mm thickness over old plastered wall surfaces including prepartion of surfaces even and smooth complete all as specified and directed.
M&L preparing the plaster surface using one coat of surafce binder of approved make (like Duralex) to strengthen the surface, applying three coats of water based squash court paint WB 147 colour white or as approved over surface on walls of squash court over a coat of primer using roller or airless spray, paint should be tough, durable and scuff resistant. Recoating time between two coats shall be between 4 to 6 hrs complete all as specified and directed.
M&L squash court red line marking paint of any approved make RAL3020 or BS04E53 red or WB147 red complete all as specified and directed.
M&L squash court hard wooden flooring with glossy/polished finish EN 14904 standard having surface board made of kiln seasoned treated maple wood/teak wood with min 21mm thick with bottom surface treated with anti termite and water resistant chemical, 55 to 90mm width and groove shape over 70mm x 45mm thick pine wood runner and 19mm EPDM rubber pad including ATT treatment complete all as specified and directed.
Material & Labour for applying two or more coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489 :2004, Alkali & fungal resistance dirt resistance exterior paint of required shade ( Company Depot Tinted ) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over old surfaces of wall complete including preparation of surfaces of walls by complete removal of existing treatment complete all as specified and directed by Engineer-in-Charge.
Material & Labour for appplying two or more coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489 :2004, Alkali & fungal resistance dirt resistance exterior paint of required shade ( Company Depot Tinted ) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces of wall complete including preparation of surfaces of walls complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames but with shutters (with out taking off shutter from the frames) exc 1.5 sq.m but n. exc 4 sq.m each, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) n. exc. 1.5 sq.m each complete all as specified and directed.
S&F anodised aluminium frame for doors, windows, ventilators with minimum thickness of powder coating 50 micron with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F aluminium anodised door shutters, (powder coating of any colour and thickness not less than 50 micron) aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 02 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and directed.
S&F 15mm Toughned glass as in hinged doors, partitions/panels automatic doors and similar work including cutting to shape, drilling holes required including hinges, handles, door closure, necessary fixtures and fittings and all materials required for erecting the glass walls complete all as spfd and directed
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed.
M &L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
M&L preparing new surface of steel of any description, over 10cm width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed.
M&L preparing old surface of steel of any description, over 10cm width or girth not other wise described and applying two coats of synthetic enamel paint complete all as specified and directed.
S&F 4mm thick sheet glass ordinary quality pin headed/plain to aluminium frame of partition etc. fixed with rubber gasket & aluminium powder coated snap beading etc. complete all as specified and directed.
S&F box type steel windows comprised of tubular frame and shutters made out of 1.25 mm thick MS tube factory made with double side shutters wire gauged shutters & glass glazed shutter(wire and glass panes shall be measured and paid separately) with side hung shutters with steel handles and steel peg stay doytailed at welded incl 2 Nos tower bolts 150 mm long for each leaf and 8 mm square bar grills at spacing as shown on drg welded to FI frame work,incl other fittings,hinges,handles tarred hold fast PCC blocks etc. all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 ,complete all as specified.
S&F 150 mm size (length of bolt) aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm size extruded aluminium alloy handles, cast type, anodised complete all as specified and directed.
S&F 300 mm size (length of bolt) aluminium alloy, anodised, sliding door bolt with hasp and staple ,(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
M&L Non-skid, coloured/digital ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm as in floors etc laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:4, set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles complete all as specified and directed.
M&L 25 mm thick PCC 1:2:4 type B-1 (20mm graded stone aggregate) as in leveling course of flooring or roof complete all as specified and directed
M & L Machine cut kota stone 20-25mm thick over cement screed base laid over and including 15 mm thick screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Dismantling 75/100mm dia cast/PVC drain pipe, jointed in cement mortar fixed in trenches and taking out of trenches removing where directed complete all as specified and directedd.
S&F PVC (SWR) pipes 110 mm bore dia, single socketed in any length with rubber ring joints fixed to walls/ laid in trenches etc , complete all as specified and directed.
S & F 110 mm bore PVC Bends (SWR) complete all as specified and directed.
M&L for plain cement concrete 75mm thick 1:3:6 type C-2, using 40mm graded crushed stone aggregate as in sub base of floor complete all as specified and directed.
M&L machine pressed precast concrete interlocking paver block any shape and size conforming to IS15658-2006 of 80mm thickness M-35 complete all as specified and directed.
M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in surface channel and drains complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and directed by Engr-in-charge.
M&L preparing the surface of roof slab by brushing with wire brushes for removal of loose material etc and sweeping with brooms, gunny bags and finally remove dust by compressed air by compressor complete, complete all as specified and directed.
M&L applying neat cement slurry with 3 Kg of cement slurry per sq.m mixed with liquid water proofing compound on surfaces of roof and plastering 10mm thick in cement mortar 1:3 mixed with liquid water proofing compound as per manufacturer's instructions and finishing the surface even and smooth without using extra cement, complete all as specified and directed. Note:- WPC shall be measured and paid separetely.
M&L one coat of cold bituminous primer to the plastered surface @ 0.40 liters per sqm conforming IS-3384 and laid a layer of APP polymeric membrane 3mm thick (minimum) weighing 3.0 Kg per sqm reinforced with polyster non woven fabric (weight not less than 150gm/sqm) by toarch application method complete all as per manufacturer instructions and sealing all the over lap shall be minimum 75mm in length side and 100mm on with side. complete all as specified and as directed.
M & L PCC 1:2:4 type B-0 (using 12.5mm graded aggregates) as in roof kerbs, mud stops, roof padding etc , complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
Taking down carefully existing aluminum / copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, fan regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed.
Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
Taking down un-serviceable sub main wiring of any type and any size from wall, ceiling etc. complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated FRLS and unsheathed multistranded copper conductor cable 1100 volts grade drawn through and including PVC rigid Concealed conduit not less than 1.8 mm thick (ISI marked) with all accessories including bends, cross, elbows tees etc of suitable size including concealed MS pressed steel (Modular sunken box) terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and Modular cover plate as top cover (ISI marked) including 1.5 sqmm PVC FRLS insulated unsheathed copper conductor multi stranded cable for continuous earth conductor connected to common arth dolly , complete all as specifid and directed for the following :- Note- (a) Proper colour coding is to be followed as per IS specification. (b) Point wiring considered for Modular switches and sockets, rate of metallic sunken box and modular sheet cover plate and other connected accessories (of any size 1 to 12 way as per site requirement) required for modular point wiring included in quoted rate. (c) Rate of modular switch and sockets will be paid seperately under relevant item.
One light controlled by one switch 5 Amp , SP , one way 240 volts
One Ceiling /Exhaust fan point controlled by one switch SP , one way, 5 Amp , 240 volts.
One multi pin socket outlet 5 amp independent.
One multi pin socket outlet 5 amp same board .
All as per the description of Serial Item No.50.00 above but using 2.5 sqmm (nominal area) multistranded copper conductor cable & 2.5 sqmm size PVC insulated FRLS and unsheathed copper conductor cable FRLS for earth continuity (green colour) for one 3 pin socket outlet 15 Amp multipurpose independent point controlled by 16 Amps switch ,SP ,one way ,240 volts for socket ,complete all as specified and directed.
S&F Socket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
S&F Socket 6A/16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
S&F Modular Switch one way 6 Amp, one module 240 volts ISI marked complete all as specified and directed.
S&F Modular Switch one way 16 Amp, one module 240 volts ISI marked complete all as specified and directed.
S&F ceiling rose surface bakelite two to three terminal complete all as specified and directed.
S&F Lamp holder with metal ring, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F LED Bulb 09/10 watt and fixing in Lamp holder complete all as specified and directed.
S&F in replacement of existing worn out ceiling light with enviromental friendly, new generation, aesthetically designed, ultra modern recessed mounted LED light luminaries of size (2'x2') an independent Isolated, electronic LED driver (SMPS based constant current supply) housed in CRCA powder coated sheet of system wattage - 36/40/42 Watt, Lumen out put- 4000-4300 Lm, THD < 10%, PF > 0.9, having short circuit and surge protection suitable for Armstrong/ Grid ceiling with all connected accessories including making connection with three core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed.
S&F Decorative ultra slim LED Tubelight fitting of LED with extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt, 6500K fitting, incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor for electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed.
S & F security light fittings better optics for uniform distribution IP 65 protection LED of 30 watt, Heat resistance glass, pressure die cast aluminium housing including 25mm dia galvanised iron pipe light grade bracket bent to shape over all length 0.60mt fixed to wall with 02 Nos Fl clamps made of 40 x 5 mm Fl, 15 cm long, 8 mm dia bolts and nuts with washers grouted in wall complete including reqd length of 1.5 Sqmm PVC multistranded BIS marked, 03 core copper conductor for connection from ceiling rose to light fittings incl testing on completion all as specified and directed.
Taking down unserviceable exhaust fan , S&F Exhaust fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers energy saving including cutting of wall all as specified and directed by Engr - in - Charge.
S & F Sheet metal enclousers, VTPN Distribution board 4 way 415 V, double door with 63A MCCB as incomer complete with rated bus bar, MCB's and neutral link earthing fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
S&F MCB DB, sheet metal enclosures double door SPN 08 way with bus bar 240 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
S&F, MCB SPN 63 Amps, 240 volts 'C' series 16 KA ,including connection with suitable size copper lugs complete all as specified and directed.
S&F, MCB SP 240 volts, 6 to 32 Amps, 'C' series 10 KA including connection with suitable size copper lugs. complete all as specified and directed.
M&L, sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML. No) not less than 25 mm dia confirming to IS 14930 (Part-1) 2001, with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqrım FRLSH copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upilo DB complete all as specified and directed (NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe including provn of earth test point made of 50 x 5 mm MS Flat in 'D' shape 500 mm legth grouted in wall complete 01 x 6 Sqmm multistrand PVC insulated copper conductor ( Green Colour) to be provided from test point to DB through 20 mm dia concealed non metallic conduit complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screend PVC bedded, galvanised steel strip or wire armoured electric power cables (Heavy duty) 1100 V grade with stranded aluminium conductor of size 16 sqmm x 4 Core, laid in trenches or passing through pipe including taking down of existing cable/service connection of any type or size and removing from site to MES store for reuse if serviceable or for credit all as specified and directed and directed by Engr-In-Charge.
Exacavation in trenches not exceeding 1.5 m width and not exceeding 1.5 m depth and getting out for laying of pipe etc in any type of soil complete all as specified and directed.
Returning, filling of excavated soil, including spreading levelling, watering and well ramming in layers, not exceeding 25 cm in soft/loose soil complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5m above the strating point in soft/loose soil complete all as specified and directed.
Sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete.
Brick, old size sub class 'B' laid in trenches with width wise along the alignment of the cable as protection complete.
S&F tube light grade galvanised with all fitting laid in trenches, fixed to wall and floor of 40 mm dia for cable protection complete all as specified and directed.
Ms Madan Gopal (BID ID -3398564)
GANDOTRA CONSTRUCTION CO (BID ID -3397370)
JP AND CO. (BID ID -3397050)
BALI CONSTRUCTION WORKS (BID ID -3398209)
satpal and brothers (BID ID -3398676)
kailu construction co (BID ID -3398679)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .