Strengthening and improvement of Building Nos. 21, 18/1, 18/2, 11/1 and 11/2 along with other miscellaneous works in North Colony under ADEN/Settlement/GRC, South Eastern Railway, Garden Reach.
T-PUB-GRC-2026-430~SER
T-PUB-GRC-2026-430
Open
Works - General
18 Months
Kolkata, West Bengal
₹0
₹18.8 L
22 Jun 2026
26 May 2026
8 Jun 2026
A-Execution of work under CPWD DSR2023 with all correction slips up-
B-Non-Schedule item including 18% GST 8857198.89 Below/P
C-Electrical item including 18% GST 11722545.74 Below/P
D-Execution of work covered under CPWD Horticulture 2020 ver-2 with
including @ 18% GST
Civil work for strengthening and improvement of Building No. 21 and 18/1, 18/2, 11/1 and 11/2
along with other miscellaneous works as per CPWD DSR 2023.
S No. Item No Description of Item Unit Qty Rate Amount
2.0 EARTH WORK
2.1S General
Earth work in excavation by mechanical
means (Hydraulic excavator)/manual
means over areas (exceeding 30 cm in
2.6 depth, 1.5 m in width as well as 10 sqm on
plan) including getting out and disposal of
excavated earth lead upto 50 m and for all
lift, as directed by Engineer-in-charge.
2.27 Supplying and filling in plinth with sand cum 6 2123.75 12742.5
2 under floors, including watering, ramming,
consolidating and dressing complete.
5.0 REINFORCEMENT CEMENT CONCRETE
5.12S PRE-CAST RCC
5.12 Providing, hoisting and fixing above plinth cum 19 10585.9 201132.1
level up to floor five level precast
reinforced cement concrete work in string
courses, bands, copings, bed plates,
anchor blocks, plain window sills and the
like, including the cost of required
centering, shuttering but , excluding cost
of reinforcement with 1:1.5:3 (1 cement :
1.5 coarse sand (zone-III) derived from
natural sources : 3 graded stone
aggregate 20 mm nominal size derived
from natural sources).
5.22S STEEL REINFORCEMENT
Steel reinforcement for R.C.C. work
including straightening, cutting, bending,
placing in position and binding all
complete above plinth level.
5.22A.6 Thermo-Mechanically Treated bars of Kg 5765 107.85 621755.25
grade Fe-500D or more.
6.0 MASONRY WORK
6.1S General
Brick work with common burnt clay
6.2 modular bricks of class designation 7.5 in
foundation and plinth in:
8.0 CLADDING WORK
8.1S General
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
Providing and fixing 18 mm thick gang
saw cut, mirror polished, premoulded and
prepolished, machine cut for kitchen
platforms, vanity counters, window sills,
facias and similar locations of required
size, approved shade, colour and texture
8.2 laid over 20 mm thick base cement mortar
1:4 (1 cement : 4 coarse sand), joints
treated with white cement, mixed with
matching pigment, epoxy touch ups,
including rubbing, curing, moulding and
polishing to edges to give high gloss finish
etc. complete at all levels
Granite stone slab colour black,
Cherry/Ruby red
Providing edge moulding to 18 mm thick
marble stone counters, Vanities etc.,
8.3 including machine polishing to edge to
give high gloss finish etc. complete as per
design approved by Engineer-in-Charge.
8.20S STONE WORK DRY CLADDING
8.31 Providing and fixing Ist quality ceramic Sqm 800 1267.95 1014360
glazed wall tiles conforming to IS: 15622
(thickness to be specified by the
manufacturer), of approved make, in all
colours, shades except burgundy, bottle
green, black of any size as approved by
9 Engineer-in-Charge, in skirting, risers of
steps and dados, over 12 mm thick bed of
cement mortar 1:3 (1 cement : 3 coarse
sand) and jointing with grey cement slurry
@ 3.3kg per sqm, including pointing in
white cement mixed with pigment of
matching shade complete.
9.0 WOOD AND P.V.C. WORK
9.1S FRAMES AND TRUSSES
Providing and fixing panelling or panelling
and glazing in panelled or panelled and
glazed shutters for doors, windows and
clerestory windows (Area of opening for
panel inserts excluding portion inside
grooves or rebates to be measured).
Panelling for panelled or panelled and
glazed shutters 25 mm to 40 mm thick :
9.7.7 Float glass panes
9.7.7.1 4 mm thick glass pane (weight not less Sqm 650 2241.8 1457170
than 10kg/sqm).
9.40S MISCELLANEOUS-WOOD WORK
Providing and fixing M.S. grills of required
pattern in frames of windows etc. with
9.48 M.S. flats, square or round bars etc.
including priming coat with approved steel
primer all complete.
9.48.2 Fixed to openings /wooden frames with Kg 8000 238.35 1906800
rawl plugs screws etc.
9.105S GYPSUM BOARD PARTITIONS
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
Providing and fixing factory made uPVC
glazed/wire mesh windows/ doors
comprising of lead free uPVC multi-
chambered frame, sash and
mullion/coupler (where ever required)
extruded profiles having minimum wall
thickness of 1.70 mm for Series R1 and R2
profiles and 2.10 mm for Series R3 and R4
profiles conforming to EN: 12608 in any
shape, colour and design duly reinforced
with galvanized mild steel section made of
required shape & size as per CPWD
Specification, uPVC extruded glazing
beads, interlocks and Inline sash adaptor
(where ever required) of appropriate
dimension, EPDM gasket, hardware, SS
304 grade fasteners of minimum 8 mm dia
with countersunk head, comprising of
matching polyamide PA6 grade sleeve for
fixing frame to finished wall as per IS 1367
: Part 1 to 14, plastic packers, plastic caps
and necessary stainless steel screws etc.
Profile of frame, sash & mullion (if
required) shall be mitred cut and fusion
welded/mechanically jointed duly sealed
at all corners, including drilling of holes for
fixing hardware and drainage of water etc.
After fixing frame the gap between frame
and adjacent finished wall shall be filled
with weather proof silicon sealant over
backer rod of approved size and quality,
all complete as per approved drawing
conforming to CPWD specification &
direction of Engineer-in-Charge. Section of
steel reinforcement and cross sections of
uPVC profiles to be as per design
approved by Engineer-in-Charge. Wire
mesh / Glazing of plain/ toughened/
laminated/ double glass unit with / without
high performance coatings as per design
requirements and conforming to IS: 3548
& IS: 16231 shall be paid separately.
Three track three panels sliding window
with two glazed & one wire mesh panels
with Aluminium channel for roller track,
wool pile, nylon rollers with SS 304 body.
above) x (40 mm & above) & both glazed
and fly screen sash (30 mm & above) x
12 (55 mm & above) with zinc alloy (zamak)
powder coated handle on every glazed
panel along with multi-point locking
system. (Height upto 1.8m)
10.0 STEEL WORK
10.1S General
Steel work welded in built up sections/
framed work, including cutting, hoisting,
10.25 fixing in position and applying a priming
coat of approved steel primer using
structural steel etc. as required.
10.25.2 In gratings, frames, guard bar, ladder, Kg 27500 172.6 4746500
railings, brackets, gates and similar works
11.0 FLOORING
11.1S General
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
Cement concrete flooring 1:2:4 (1 cement
: 2 coarse sand : 4 graded stone
aggregate) finished with a floating coat of
neat cement, including cement slurry, but
excluding the cost of nosing of steps etc.
stone aggregate
11.37S CERAMIC GLAZED TILES
11.37 Providing and laying Ceramic glazed floor Sqm 800 1096.55 877240
tiles of size 300x300 mm (thickness to be
specified by the manufacturer) of 1st
quality conforming to IS : 15622 of
approved make in colours such as White,
15 Ivory, Grey, Fume Red Brown, laid on 20
mm thick cement mortar 1:4 (1 Cement : 4
Coarse sand), Jointing with grey cement
slurry @ 3.3 kg/sqm including pointing the
joints with white cement and matching
pigment etc., complete.
11.41S VITRIFIED FLOOR TILES
Providing and laying vitrified floor tiles in
different sizes (thickness to be specified
by the manufacturer) with water
absorption less than 0.08% and
conforming to IS: 15622, of approved
11.41 make, in all colours and shades, laid on
20mm thick cement mortar 1:4 (1 cement
: 4 coarse sand), jointing with grey cement
slurry @ 3.3 kg/ sqm including grouting
the joints with white cement and matching
pigments etc., complete.
12.0 ROOFING
12.37S RAIN WATER SPOUT AND PIPE
Providing and fixing on wall face
unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including
jointing with seal ring conforming to IS :
5382, leaving 10 mm gap for thermal
expansion, (i) Single socketed pipes.
13.0 FINISHING
13.4S CEMENT PLASTER (IN COARSE SAND)
15 mm cement plaster on rough side of
single or half brick wall of mix:
13.44S EXTERIOR FINISHING
Finishing with Deluxe Multi surface paint
system for interiors and exteriors using
Primer as per manufacturers specifications
13.48.1 Two or more coats applied on walls @ 1.25 Sqm 14900 193.7 2886130
19 ltr/10 sqm over and including one coat of
Special primer applied @ 0.75 ltr /10 sqm
Painting with synthetic enamel paint of
13.61 approved brand and manufacture to give
an even shade :
13.80 Providing and applying white cement Sqm 1530 156.05 238756.5
based putty of average thickness 1 mm, of
21 approved brand and manufacturer, over
the plastered wall surface to prepare the
surface even and smooth complete.
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
Distempering with 1st quality acrylic
distemper, having VOC (Volatile Organic
Compound ) content less than 50 grams/
13.81 litre, of approved brand and manufacture,
including applying additional coats
wherever required, to achieve even shade
Applying priming coats with primer of
approved brand and manufacture, having
low VOC (Volatile Organic Compound )
13.85.3 With water thinnable cement primer on Sqm 16000 73.95 1183200
23 wall surface having VOC content less than
14.0 REPAIRS TO BUILDING
14.72S FINISHING
14.72 Providing and fixing double scaffolding Sqm 1000 338.25 338250
system (cup lock type) on the exterior
side, up to seven story height made with
40 mm dia M.S. tube 1.5 m centre to
centre, horizontal & vertical tubes joining
with cup & lock system with M.S. tubes,
M.S. tube challies, M.S. clamps and M.S.
staircase system in the scaffolding for
working platform etc. and maintaining it in
a serviceable condition for the required
duration as approved and removing it
there after. The scaffolding system shall
be stiffened with bracings, runners,
connection with the building etc wherever
required for inspection of work at required
locations with essential safety features for
the workmen etc. complete as per
directions and approval of Engineer-in-
charge .The elevational area of the
scaffolding shall be measured for payment
purpose .The payment will be made once
irrespective of duration of scaffolding.
15.0 DISMANTLING AND DEMOLISHING
15.1S General
Demolishing cement concrete manually/
by mechanical means including disposal of
material within 50 metres lead as per
direction of Engineer - in - charge.
(including equivalent design mix)
Dismantling doors, windows and clerestory
windows (steel or wood) shutter including
15.12 chowkhats, architrave, holdfasts etc.
complete and stacking within 50 metres
Dismantling precast concrete or stone
15.40 slabs in walls, partition walls etc. including
stacking within 50 metres lead :
15.56 Dismantling old plaster or skirting raking Sqm 330 54.65 18034.5
out joints and cleaning the surface for
plaster including disposal of rubbish to the
dumping ground within 50 metres lead.
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
15.60 Disposal of building rubbish / malba / cum 160 263.95 42232
similar unserviceable, dismantled or waste
materials by mechanical means, including
loading, transporting, unloading to
approved municipal dumping ground or as
approved by Engineer-in-charge, beyond
50 m initial lead, for all leads including all
lifts involved.
16.0 ROAD WORK
16.49S MISCELLANEOUS
16.68 Providing and laying 60mm thick factory Sqm 600 972 583200
made cement concrete interlocking paver
block of M -30 grade made by block
making machine with strong vibratory
compaction, of approved size, design &
shape, laid in required colour and pattern
over and including 50mm thick compacted
bed of coarse sand, filling the joints with
line sand etc. all complete as per the
direction of Engineer-in-charge.
18.0 WATER SUPPLY
18.7S C.P.V.C. PIPES
Providing and fixing G.I. pipes complete
with G.I. fittings and clamps, including
cutting and making good the walls etc. (
Internal work - Exposed on wall )
Providing and fixing G.I. Pipes complete
with G.I. fittings and clamps, including
making good the walls etc. concealed
pipe, including painting with anti corrosive
bitumastic paint, cutting chases and
making good the wall :
22.0 WATER PROOFING
22.1S General
Grading roof for water proofing treatment
22.22A Providing and applying fibre reinforced Sqm 1400 563.1 788340
elastomeric liquid water proofing
membrane with resilient acrylic polymers
having Sun Reflectivity Index (SRI) of 105
on top of concrete roof in three coats
@10.76 litre/ 10 sqm. One coat of self-
priming of elastomeric water proofing
liquid (dilution with water in the ratio of
36 3:1) and two coats of undiluted
elastomeric water proofing liquid (dry film
thickness of complete application/system
not less than 500 microns). The operation
shall be carried out after scrapping and
properly cleaning the surface to remove
loose particles with wire brushes,
complete in all respect as per the direction
of Engineer-in-Charge.
26.0 NEW TECHNOLOGIES AND MATERIALS
26.28S REPAIR AND REHABILITATION ITEMS
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
Chipping of unsound/weak concrete
material from slabs, beams, columns etc.
with manual Chisel and/ or by standard
power driven percussion type or of
approved make including tapering of all
26.28 edges, making square shoulders of
cavities including cleaning the exposed
concrete surface and reinforcement with
wire brushes etc. and disposal of debris
for all lead and lifts all complete as per
direction of Engineer-In-Charge
Cleaning of reinforcement from rust from
the reinforcing bars to give it a total rust
f r e e steel surface by using alkaline
chemical rust remover of approved make
with paint brush and removing loose
particles after 24 hours of its application
with wire brush and thoroughly washing
with water and allowing it to dry, all
complete as per direction of Engineer-In-
Drilling suitable holes in reinforced or
plain cement concrete with power driven
drill machine to a minimum depth of 100
mm upto 200 mm in RCC beams, lintels,
columns and slabs to introduce steel bars
26.30 for sunshades/balconies including fixing
the steel bars in position using epoxy resin
anchor grout of approved make but
excluding the cost of reinforcement, all
complete as per direction of Engineer-In-
Providing, mixing and applying bonding
coat of approved adhesive on chipped
26.31 portion of RCC as per specifications and
direction of Engineer-In-charge complete
in all respect.
26.31.2 Epoxy bonding adhesive having coverage Sqm 400 285.2 114080
2.20 sqm/kg of approved make
Schedule Schedule B-Non-Schedule item including 18% GST
Civil work for Non-Schedule items including @ 18% GST for strengthening and improvement of
Building No. 21 and 18/1, 18/2, 11/1 and 11/2 along with other miscellaneous works.
S No. Item No Description of Item Unit Qty Rate Amount
1 1 Supplying and fixing of 02 way CP Bib cock Each 78.00 2038.47 159000.66
w i t h w a l l flange of Jaquar m a d e baring
m o d e l no. QQT-7041 or similar made
approved by Engineer in Charge. Rate
including GST @ 18%.
commode i.e., rimless single piece - WC
with UF soft close seat cover, hinges, fixing
accessories set, cistern fittings, *P trap -
180mm, size 365 x 655 x 765mm of Jaquar
made bearing model no. LYS- WHT 38851
P or similar approved b y Engineer in
Charge. Rate including GST @ 18%.
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
3 3 Supplying and fixing Hand Shower (Health Each 78.00 1341.02 104599.56
Faucet) ( A B S Body) with 8mm Dia, 1.2
Meter Long Flexible Tube & Wall Hook out
Jaquaf made bearing model no. ALD-CHR-
5 7 3 N o r s i m i l a r m a d e a p p r o v e d by
Engineer in Charge. Rate including GST @
4 4 Supplying and fixing Toilet Rail Holder with Each 78.00 1447.78 112926.84
Fla p o f Jaquar made bearing model no.
AKP-35753P oi similar made appro ved by
Engineer in Charge.Rate including GST @
5 5 Supplying and fixing Towel Ring Round of Each 78.00 1046.18 81602.04
Jaguar made bearing model no. AQN-7721
o r similar made approved b y Engineer in
Charge. Rate including GST @ 18%.
6 6 Supplying and fixing full taughened glass Sqm 78.00 5622.33 438541.74
12mm thick unbreakable (Modi Guard or
similar) i n window/Door with revolving /
sliding mechanism as per direction of
Engineer-in- charge or h i s representative
at site w i t h s u p e r i o r q u a l i t y locking
arrangement. The rate is inclusive of
contractor's ladour, fittings, materials,
tools, plants, freight GST a n d a l l other
charges complete . Rate including GST @
Long Without Lower Hangers b u t w ith 3
hooks of Jaquar made bearing model no.
ACN1181FHN or similar made approved by
Engineer in Charge. Rate including GST @
8 8 Providing & fixing of Wash Basin Mode Mid Each 78.00 24123.07 1881599.46
Ocean Model. MO8027), size 32 with PVC
v a n i t y c a b in a le - w a l l h u n g o similar
approved b y Engineer in Charge Rate is
including, Cement, LaDour, Lead Lift
etc.Rate including GST @ 18%.
9 9 Providing & fixing telephonic hand shower Each 78.00 4578.92 357155.76
of Jaquar make HSH 1731 o r similar
approved by Engineer in Charge. Rate
including GST @ 18%
10 10 Providing & fixing spray hose Jaquar code Each 78.00 1772.70 138270.60
n o . CQT-23069 or similar approved by
Engineer in Charge. Rate including GST @
11 11 Providing & fixing bottle trap jaquar code Each 78.00 1846.04 143991.12
n o . ALD 769 or similar approved by
Engineer in Charge. Rate including GST @
12 12 Providing & fixing b a s i n waste coupling Each 78.00 664.88 51860.64
jacquar code No. ALD 709L130 o r similar
approved by Engineer in Charge.Rate
including GST @ 18%
13 13 Providing a n d fi x i n g Decorative Brass Each 78.00 1636.64 127657.92
Handle 250mm long of similar approved by
Engineer in Charge. Rate including GST @
14 14 Providing & fixing Shower rose jaguar code Each 42.00 5329.21 223826.82
n o . O H S 3 5 4 9 7 or similar approved by
Engineer in Charge. Rate including GST @
15 15 Providing & fixing sink mnixure jaquar Each 78.00 4027.91 314176.98
code no. CQT 233098 jaguar code no.CQT
233098 or similar approved by Engineer in
Charge. Rate including GST @ 18%.
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
jaguar code No. CQT23281UPR or similar
approved by Engineer in Charge. Rate
including GST @ 18%.
17 17 Supply and Fixing o f digital print Wall Each 78.00 197.23 15383.94
Paper o f approved pattern and design by
Engineer - i n - Charge. T h e cost included
all materials, Tools and Plants Labour,
lead, lift, ascent, decent Taxes a n d all
other incidental charges complete. Rate
including GST @ 18%.
18 18 Supply of Digital Board Pasted on Acrylic Square 2250.00 921.13 2072542.50
Sheet o f which matter, colour, front, size Foot
and design approved by Engineerin-Charge
and fixing on existing frame.Rate including
19 19 S u p p l y of painted N a m e Board which Square 165.00 2429.87 400928.55
m a t t e r , c o l o u r , f r o n t size and design Foot
approved by Engineer- in-Charge made
w ith chromium plated brass/ steel plate
and fixing on e x i s t i n g frame. Rate
including GST @ 18%.
Schedule Schedule C-Electrical item including 18% GST
Electrical work for strengthening and improvement of Building No. 21 and 18/1, 18/2, 11/1 and 11/2
along with other miscellaneous works.
S No. Item No Description of Item Unit Qty Rate Amount
1 1 Supply and Laying of Single-Phase Point Point 2926.00 706.82 2068155.32
Wiring (includes Phase, Neutral and
Protective Earth wire) from Modular Switch
Board to equipment's (light, Ceiling fan,
Exhaust Fan, calling bell etc.) ceiling rose
through wall concealed PVC conduit of size
25sq mm or more. Modular Switch Board,
modular switch, wiring, PVC conduit, wall
cutting, wall refilling/finishing, Ceiling rose,
copper lugs for termination etc. are
inclusive in the point wiring. Wiring shall
be done by cutting of the wall to
accommodate PVC conduit, utilizing of
proper bends wherever required, re-fill
and re-finish the wall as like original by
plastering and painting after wiring. Size
of Phase, Neutral and Protective earth wire
shall be 1.5sqmm, 1.5 sqmm & 2.5 sq mm
respectively. Socket of 6 A, if required,
shall be provided in the modular board
and shall be considered as half point. The
detailed specification of different
component of point wiring is provided in
explanatory note.
2 2 Supply of Modular Switch Board flush type Point 1254.00 234.82 294464.28
with GI Enclosure & Cover made of tough
non-ignitable insulating material with 01
no Modular Switch of 16A (IS:3854/1997)
and 01 no Modular Socket 6Pin 16/6A(IS
1293-2019). The detailed specification of
different component is provided in
explanatory note.
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
3 3 Fixing and commissioning of switch socket Point 1254.00 11.80 14797.20
board (Power) as above (Item No.-2)
includes wall cutting to accommodate &
flush the modular switch board GI
enclosure with modular type switch and
socket, all the wire connection and
termination with properly crimped Lugs
and connector (copper) and re-filling and
re-finishing the wall as like original by
plastering and painting after fixation of
modular board. This work shall follow the
code of IS 732 (1989).The earthing
connection work shall follow the code of
practice as per IS 3043 (1987).
4 4 Supply and Laying of main service/sub- Metre 12500.00 95.58 1194750.00
service line Single Phase (includes Phase,
Neutral and Protective Earth wires, each
2.5 sqmm) through wall concealed PVC
conduit of size 25sq mm or more. Wiring
shall be done by wall cutting to
accommodate PVC conduit, utilizing of
proper bends wherever required, re-fill
and re-finish the wall as like original by
plastering and painting after wiring. All the
connection/termination shall be done with
properly crimped Lugs and connector (
copper) as per site requirement Rate per
Mtr. shall means supply and laying of 1
Mtr. phase wire, 1 Mtr. neutral wire, 1Mtr.
earth wire through 1 Mtr. PVC conduit and
1 mtr wall cutting to accommodate the
whole wiring and re-fill and re-finish the
wall as like original by plastering and
painting after wiring] . The detailed
specification of different component is
provided in explanatory note.
5 5 Supply and Laying of main service/sub- Metre 6000.00 172.28 1033680.00
service line Single Phase (includes Phase,
Neutral and Protective Earth wires, each
4.0 sqmm) through wall concealed PVC
conduit of size 25sq mm or more. Wiring
shall be done by wall cutting to
accommodate PVC conduit, utilizing of
proper bends wherever required, re-fill
and re-finish the wall as like original by
plastering and painting after wiring. All the
connection/termination shall be done with
properly crimped Lugs and connector (
copper) as per site requirement Rate per
Mtr. shall means supply and laying of 1
Mtr. phase wire, 1 Mtr. neutral wire, 1Mtr.
earth wire through 1 Mtr. PVC conduit and
1 mtr wall cutting to accommodate the
whole wiring and re-fill and re-finish the
wall as like original by plastering and
painting after wiring] . The detailed
specification of different component is
provided in explanatory note.
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
6 6 Supply and Laying of main service/sub- Metre 2000.00 326.86 653720.00
service line Single Phase (includes Phase,
Neutral each-1.5 sqmm and Protective
Earth wires 2.5 sqmm) through heavy duty
rigid GI Steel Conduit Pipe as per IS: 14927
(Pt.II)/latest/IS: 9537 (Pt.III)/latest etc.
Wiring shall be done fixing GI Steel
Conduit Pipe , utilizing of proper bends
wherever required, using stainless steel
screw or saddle. All the connection/
termination shall be done with properly
crimped Lugs and connector (copper) as
per site requirement Rate per Mtr. shall
means supply and laying of 1 Mtr. phase
wire, 1 Mtr. neutral wire, 1Mtr. earth wire
through 1 Mtr. GI Steel Conduit Pipe and
fixation] . The detailed specification of
different component is provided in
explanatory note.
7 7 Supply and Laying of main service/sub- Metre 1000.00 428.34 428340.00
service line Single Phase (includes Phase,
Neutral and Protective Earth wires, each
4.0sqmm) through heavy duty rigid GI
Steel Conduit Pipe as per IS: 14927
(Pt.II)/latest/IS: 9537 (Pt.III)/latest etc.
Wiring shall be done fixing GI Steel
Conduit Pipe , utilizing of proper bends
wherever required, using stainless steel
screw or saddle. All the connection/
termination shall be done with properly
crimped Lugs and connector ( copper) as
per site requirement Rate per Mtr. shall
means supply and laying of 1 Mtr. phase
wire, 1 Mtr. neutral wire, 1Mtr. earth wire
through 1 Mtr. GI Steel Conduit Pipe and
fixation] . The detailed specification of
different component is provided in
explanatory note.
8 8 Supply , fixing and commissioning of 20A Each 307.00 243.08 74625.56
,4 module Power Unit comprises 20A
Starter (ISI marked, rated voltage 220V
AC, rated current:20 Amps, conforming to
IS/IEC 60898-1:2015 (Reaffirmed
Year:2024) or latest, , Un adjustable time
current characteristics and suitable for use
in protection of industrial, commercial and
domestic electrical installations) , 16A
socket& additional 16A plug. Suitable to
operate AC supply 230v/50 Hz with GI
Enclosure confirms to IS 14772 including
internal wiring with PVC insulated 4.0
Sq.mm. 1100V grade, single core,
multistranded FR-LSH copper conductor.
Modular board Cover shall be made of
tough Non- Ignitable insulating material,
material of base -vitrified ceramic,
Conforming to IS : 1293-2019, Amendment
no. 1 or latest with ISI mark. Fixing and
commissioning shall be done concealed in
the wall along with termination
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
9 9 Supply of LED wall light / Bracket light Each 328.00 434.24 142430.72
fitting with 7W lamp 5 star rated energy
efficient (white/ warm white) compliance
to IS 1602 (part 1):2012 efficiency
minimum 130 Lm/watt, suitable for
230V,50Hz, AC, aluminum die cast with
brushed nickel finish material and opal
glass diffuser with supply of installation
fittings. Before supply of the materials the
drawing/ design / technical datasheet/
make and model should be submitted by
firm for prior approval.
10 10 Fixing and commissioning of LED wall light Each 328.00 43.66 14320.48
/ Bracket light fitting with 7W lamp as
above (Item No.-09). Fixing shall be done
using GI/SS Fastners, screw etc. as per
standard manner and necessary
connection to be done with 1.5 sq. mm,
Copper Conductor (flexible), as phase and
neutral and continuous earth/ protective
conductor of 2.5 sq. mm, Copper
Conductor(flexible).The detailed
specification of different component is
provided in explanatory note.
11 11 Supply of 7-Watt LED Light compliance to Each 152.00 2160.58 328408.16
IS:10322 (Part-5/sec 2):2012 for Wall
Picture, Mirror with flexible neck,
aluminum die cast with brushed nickel
finish material, Warm White 3000K, with
good Color rendering (CRI>80), suitable to
operate 230V, AC supply, inbuilt surge
protection, efficiency minimum 130
Lm/watt. Before supply of the materials
the drawing/ design / technical datasheet/
make and model should be submitted by
firm for prior approval.
12 12 Fixing & commissioning of 7-Watt LED Each 152.00 107.38 16321.76
Light as above (Item No.- 11). Fixing shall
be done using GI/SS Fastners, screw etc.
as per standard manner and necessary
connection to be done with 1.5 sq. mm,
Copper Conductor (flexible), as phase and
neutral and continuous earth/ protective
conductor of 2.5 sq. mm, Copper
Conductor(flexible).The detailed
specification of different component is
provided in explanatory note.
13 13 Supply of Golden Antique design double Each 296.00 1898.62 561991.52
bracket wall lamp fitting with glass cover
with 2 no 7W energy efficient 5 star LED
lamp (white/ warm white) compliance to IS
1602 (part 1):2012 efficiency minimum
130 Lm/watt, suitable for 230V,50Hz, AC,
aluminum die cast with brushed nickel
finish material and opal glass diffuser with
supply of installation fittings. Before
supply of the materials the drawing/
design / technical datasheet/ make and
model should be submitted by firm for
prior approval.
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
14 14 Fixing and commissioning of LED wall light Each 296.00 94.40 27942.40
/ Bracket light fitting with 7W lamps as
above (Item No.-13). Fixing shall be done
using GI/SS Fastners, screw etc. as per
standard manner and necessary
connection to be done with 1.5 sq. mm,
Copper Conductor (flexible), as phase and
neutral and continuous earth/ protective
conductor of 2.5 sq. mm, Copper
Conductor(flexible).The detailed
specification of different component is
provided in explanatory note.
15 15 Fixing and commissioning of LED Batten Numbers 560.00 15.34 8590.40
18 watt (will be supplied by railway) as
standard manner using GI/SS screw (if
required) and necessary connection to be
done with 1.5 sq. mm, Copper Conductor
(flexible), as phase and neutral and
continuous earth/ protective wire of 2.5
sq. mm, Copper Conductor(flexible).The
detailed specification of different
component is provided in explanatory
16 16 Fixing and commissioning of BLDC Fan Each 373.00 130.98 48855.54
1400mm sweep (supplied from Railway
side) ,inclusive of supply and fixing of
BLDC fan regulator and other requisite
materials as per site requirement and
necessary connection to be done with 1.5
sq. mm, Copper Conductor (flexible), as
phase and neutral and continuous earth/
protective conductor of 2.5 sq. mm,
Copper Conductor(flexible).The detailed
specification of different component is
provided in explanatory note.
17 17 Supply of Electric Chimney of wall Each 40.00 13430.76 537230.40
mounted type, with Auto-Clean feature, 60
cm having minimum Air Suction Capacity
of 1400 m3/hr. with 5 star BLDC Motor and
Motion Sensor Touch controls [for chimney
operation with movement of the hand], for
working at single phase 230 V± 10%,
50Hz AC Supply, including Flexible
Aluminum Duct Pipe with Cowl (diameter-
6") for exhaust having length of 10ft.
Material of Chimney shall be of Stainless
Steel of grade 304, filter-less technology
[ensures higher airflow and lower
maintenance], Stainless Steel oil collector
tray, Turbo Exhaust mode [in this mode
the chimney will run on the highest speed
and in case of any blockage in the system
the same will be removed], with Safety as
per IS:302 Part 1: 2008 or latest with all
required GI/SS nut, bolt and all other
materials to complete the work in all
respect as per direction site In Charge.
18 18 Fixing & commissioning of Kitchen Each 40.00 671.42 26856.80
Chimney as above (Item No.- 17) as per
direction site in-charge and if any
termination required same should be done
with properly crimped Lugs and connector
(copper) as per site requirement and
fixation of Kitchen Chimney and Exhaust
Duct pipe shall be done with suitable GI/SS
fastener, Clamp, Wooden support,
nut/bolts etc. As per site requirement and
as advised by consignee.
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
star BLDC Motor, 1300 RPM, Silent
operation high air delivery of minimum
1150 CMPH with ISI marked, having Self
closing damper compatible with exhaust
fan, suitable for 230V,50Hz, AC supply,
with other requisite accessories etc.
20 20 Fixing and commissioning of Exhaust Fan Each 184.00 129.80 23883.20
(250mm) as above (Item No.- 19) and
necessary connection to be done with 1.5
sq. mm, Copper Conductor (flexible), as
phase and neutral and continuous earth/
protective conductor of 2.5 sq. mm,
Copper Conductor(flexible).The detailed
specification of different component is
provided in explanatory note.
21 21 Supply of Stationary Storage Type Electric Each 112.00 7299.48 817541.76
Water Heater (Geyser) of 25 Ltrs Capacity
Conforming to IS:2082: 2018, amendment
no. 1 and with latest
amendments/revisions with ISI mark, BEE
star rating 5, Closed type as per clause
3.102 of IS 302-2-21: 2018 or latest, with
Stainless steel panel for Vertical wall
mounting of Water Heater. Material of
Inner Container & Body of Water Tank
shall be of Stainless Steel of grades 304,
304L, 316, 316L as per IS 1570 (Part
5):1985 (Reaffirmed 2018) or latest.
Insulation in-between Outer SS Body &
inner SS Container shall be of Fire
retardant type. Finish as per clause 21.1 of
IS 2082. Anode Rod (also called Sacrificial
rod) shall be provided in addition to Heater
element. Water Heater shall be of Class I
type as per IS 302-2-21 clause 6.1 with
double insulation or reinforced insulation,
Water Heater shall be for Indoor
Installation with at least IP-X1. Pressure
relief device shall be provided in the Water
Heater. Instruction for operation of
Pressure Relief Device as per clause 7.12
(b) of IS 302-2-21 shall be provided with
the material as well as marked on Water
Heater such that it is visible in normal use.
Leakage current for Water Heater shall not
exceed 0.21 mA per KW or 1.5 mA
whichever is lesser.
22 22 Fixing ,commissioning and testing of Each 112.00 364.62 40837.44
geyser as above (Item No.21) using
stainless steel Fastners/ screw and clamp
as per direction of railway representative.
23 23 Supply of 4 way double door PPI DB, wall Numbers 40.00 6468.76 258750.40
mounted type, made of CRCA Sheet Steel,
double door, powder coated confirms to IS
protection, complete with insulated TP
copper busbar with earth terminal, neutral
link ,interconnecting wires (colour coded),
cable ties & blanking plates and suitable
for MCB incomer , Cu Bus bar conforms to
IS:613/latest & 2826/latest and all other
items as per relevant standard
specifications.
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
24 24 Fixing and commissioning of 4 way double Numbers 40.00 323.32 12932.80
door PPI DB as mentioned at item no 23,
along with installation of MCCB/MCB as
per site requirement and direction of
railway authority (MCCB/MCB will be
provided from railway store).Its connection
and installation with incoming & outgoing
cables/wires with necessary termination
with cable/wires glands/Lugs/ Bimetallic
Lugs terminal etc. with proper crimping as
per site requirement. After commissioning
thermal test, Earthing testing, tripping test
etc. shall be carried out in the presence of
railway representative with adequate load
(cost for that test shall be borne by the
contractor) and proper labeling (circuit
identification) of the outgoing side and
incoming side switchgear shall be done by
pasting sticker. Dressing of wire shall be
done as per code of IS 732. The earthing
connection work shall follow the code of
practice as per IS 3043 (1987).DB fixation
shall be done by cutting the wall to
accommodate the DB wall flushed fixation,
plastering & leveling the wall before DB
fixation, fixation of DB with GI/SS
fasteners, refilling/ re-finishing the wall
like original with necessary plastering,
painting as per direction of railway
(CRCA sheet minimum thickness 1.6 mm)
enclosure,ISI marked, Instantaneous
tripping range:B, no. of poles: 4 pole with
4PP (PP=protected pole), rated voltage
415V AC, rated current:63 Amps,
conforming to IS/IEC 60898-1:2015
(Reaffirmed Year:2024) or latest, with
rated short circuit current capacity 10KA,
fixed unadjustable time current
characteristics and suitable for use in
protection of industrial, commercial and
domestic electrical installations. MCBs
shall be suitable for 50 Hz AC main
supplies. MCBs shall have fixing
arrangement for mounting on steel rails of
top Hat section Rail TH:35-7.5 conforming
to IS/IEC 60715:2017 (Reaffirmed
Year:2024) or latest.
26 26 Supply of 6-32A,15kA, SP MCB, ISI marked, Numbers 480.00 214.76 103084.80
Instantaneous tripping range: B curve, No.
of poles: single pole with 1 PP
(PP=Protected pole), rate voltage 240V
AC, rated current: 6-32 Amps, conforming
to IS/IEC 60898-1:2015 (Reaffirmed
Year:2024) or latest, with rated short
circuit current capacity 15 KA, fixed Un
adjustable time current characteristics and
suitable for use in protection of industrial,
commercial & domestic electrical
installation. MCBs shall be suitable for 50
Hz AC main supplies. MCBs shall have
fixing arrangement for mounting on steel
rails of top Hat section Rail TH:35- 7.5
conforming to IS/IEC 60715:2017.
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
27 27 Supply of Type 2 AC Surge protection Numbers 40.00 3347.66 133906.40
device (320V), TPN,20kA, conforms to IEC
61643-21 latest, all other items as per
relevant specifications along with all
relevant accessories. It shall be suitable
for 50 Hz AC main supplies and shall have
fixing arrangement for mounting on steel
rails of top Hat section Rail TH:35-7.5
conforming to IS/IEC 60715:2017.
conforms to IEC61009-1, IS 12640-2, EN
61009-1/latest, and all other items as per
relevant specifications and as per IS
standard along with all relevant
accessories, suitable for use in protection
of industrial, commercial & domestic
electrical installation. It shall be suitable
for 50 Hz AC main supplies and shall have
fixing arrangement for mounting on steel
rails of top Hat section Rail TH:35-7.5
conforming to IS/IEC 60715:2017.
29 29 Supply and laying of 19x6 mm GI strips for Metre 450.00 109.52 49284.00
earthing, clamped to brick wall, cable tray
etc., as required . All the clamps, Fastners,
Screws etc to be used for fixation purpose
shall be made of stainless steel. All the
intermediate joints shall be connected
using clamp and nut bolt arrangement or
properly welding.
30 30 Laying of cable (cable will be supplied by Metre 2500.00 47.20 118000.00
Rly.) in air/wall/wooden structure /cable
tray with supply & fixing of suitable GI/SS
clamp/saddle/fixtures/covers/encasing etc.
(minimum clamping/saddle interval 30cm)
including termination, connection with the
electrical equipment/installations by
suitable gland/socket/lugs/ Bimetallic lugs
etc., testing and commissioning of cables
as per site requirement inclusive of supply
of all requisite materials required for the
same. The location/place and actual
length of laying depends upon the specific
site requirement and as advised by
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
31 31 Supply fixing commissioning of GI Hot Dip Metre 150.00 686.38 102957.00
ladder type cable tray wall mountable of
dimension (width 200 mm, Height 75 mm,
Tray thick ness 2.0 mm) along with two
nos. Coupler Plate and minimum 08 set of
nut-bolts & washers for coupling. The tray
is to be supplied along with all the
required accessories for wall mounting
such as Support brackets, Nut-Bolts,
Washers, Fasteners & Clamps etc. Width
of support bracket shall be minimum 280
mm so that tray can be mounted at a
distance 50mm from wall. The quantity of
Support bracket and associated
accessories should be suitable for
supporting & mounting of Cable-tray at a
distance of 2 Meter or less. Support
brackets, Coupler Plates, Nut-Bolts &
Washers, Fasteners & Clamps etc. shall be
of either Stainless Steel (SS) or Hot-dip
Galvanized Iron (GI). Galvanizing Hot dip
shall be as per IS 2629/4759 for cable tray
and associated accessories. Fixation will
be done as per direction of railway
authorized representative, cost of the
fixation includes all the materials cost as
per standard for fixation of cable tray
hanging from roof/ceiling and wall
32 32 Supply fixing commissioning of GI Hot Dip Metre 230.00 364.62 83862.60
Perforated Type Cable Tray wall
mountable of dimension ( width 150 mm,
Height 50 mm, Tray thick ness 2.0 mm,)
along with two nos. Coupler Plate and
minimum 08 set of nut-bolts & washers for
coupling. The tray is to be supplied along
with all the required accessories for wall
mounting such as Support brackets, Nut-
Bolts, Washers, Fasteners & Clamps etc.
Width of support bracket shall be
minimum 230mm so that tray can be
mounted at a distance 50mm from wall.
The quantity of Support bracket and
associated accessories should be suitable
for supporting & mounting of Cable-tray at
a distance of 2 Meter or less . Support
brackets, Coupler Plates, Nut-Bolts &
Washers, Fasteners & Clamps etc. shall be
of either Stainless Steel (SS) or Hot-dip
Galvanized Iron (GI). Galvanizing Hot dip
shall be as per IS 2629/4759 for cable tray
and associated accessories. Fixation will
be done as per direction of railway
authorized representative, cost of the
fixation includes all the materials cost as
per standard for fixation of cable tray on
wall structure suitable for laying of cable.
33 33 Supply of Earth cone including sump box Each 10.00 1572.94 15729.40
and chemical compound etc as per
CEEGRC'sDrawing no : CEE/G/A3/P-
150,Alt.1 with supply of all requisite items.
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
34 34 Fixing and commissioning of Earth cone Each 10.00 451.94 4519.40
including sump box as above (Item No.-
33) with supply of all requisite items. The
Cost includes excavation of pit either
manual or by machine in any kind of soil,
pit making and making of sump box with
salt, charcoal etc. and construction of RCC
Cover for sump box of minimum
dimension of 1.5ftx1.5ftx1.5 ft. Cost also
includes connection of 8 SWG GI. wires/ GI
strips between earth cone and main
switch/DB/Street light pole/LT /HT panels
etc. as per site supervisor's instruction.
Cost also includes earth clamp of size 50 X
6 mm GI testing of earth resistance jointly
with Railway representative and the earth
value shall be printed on the earth sump
box. The work shall follow the code of
practice as per IS 3043 (1987).
35 35 Dismantling, Removing of existing wiring, Job 72.00 1180.00 84960.00
incoming cable , DB , Junction box and all
the electrical fittings, switch board etc at
each quarter and All released and
dismantled materials to be handed over to
SSE(EL-P/GRC) consignee Store with
Contractor's own labour, transport, load,
36 36 Supply of 18 Way SPN DB with cable end Each 32.00 8567.98 274175.36
box & Blank plates, wall mounted type,
made of CRCA Sheet Steel [Minimum
thickness 1.6mm], IP 54, IK 09, confirms to
door, powder coated complete with earth
terminal, neutral link. Cu Bus bar conforms
to IS:613/latest & 2826/latest and all other
items as per relevant specifications and as
per IS Standard.
37 37 Installation and commissioning of 18 Way Each 32.00 856.68 27413.76
SPN DB as mentioned at item no 36, along
with installation of MCB,SPD and RCBO as
per site requirement and as per direction
of railway authority (MCB/RCBO/SPD will
be provided from railway store).its
connection and installation with incoming
& outgoing cables/wires with necessary
termination with cable/wires glands/Lugs/
Bimetallic Lugs terminal etc. with proper
crimping as per site requirement. After
commissioning thermal test, Earthing
testing, tripping test etc. shall be carried
out in the presence of railway
representative with adequate load (cost
for that test shall be borne by the
contractor) and proper labeling (circuit
identification) of the outgoing side and
incoming side switchgear shall be done by
pasting sticker. Dressing of wire shall be
done as per code of IS 732. The earthing
connection work shall follow the code of
practice as per IS 3043 (1987). DB fixation
shall be done by cutting the wall to
accommodate the DB wall flushed fixation,
plastering & levelling the wall before DB
fixation, fixation of DB with GI/SS
fasteners, re-filling/re-finishing the wall
like original with necessary plastering,
painting asper direction of railway
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
Instantaneous tripping range:B curve, no.
of poles: double pole with 2 PP
(PP=protected pole), rated voltage 240V
AC, rated current: 63 Amps, conforming to
IS/IEC: 60898-1:2015 (Reaffirmed
Year:2024) or latest, with rated short
circuit current capacity 10KA, fixed
unadjustable time current characteristics
and suitable for use in protection of
industrial, commercial and domestic
electrical installations. MCBs shall be
suitable for 50 Hz AC main supplies. MCBs
shall have fixing arrangement for
mounting on steel rails of top Hat section
Rail TH:35-7.5 conforming to IS/IEC
60715:2017 (Reaffirmed Year:2024) or
RCBO, conforms to IEC61009-1, IS 12640-
2, EN 61009-1/latest, and all other items
as per relevant specifications and as per IS
standard along with all relevant
accessories, suitable for use in protection
of industrial, commercial & domestic
electrical installation. It shall be suitable
for 50 Hz AC main supplies and shall have
fixing arrangement for mounting on steel
rails of top Hat section Rail TH:35-7.5
conforming to IS/IEC 60715:2017. with all
relevant accessories.
device (320V), DP,20kA, conforms to IEC
61643-21 latest, all other items as per
relevant specifications along with all
relevant accessories. It shall be suitable
for 50 Hz AC main supplies and shall have
fixing arrangement for mounting on steel
rails of top Hat section Rail TH:35-7.5
conforming to IS/IEC 60715:2017.
Schedule D-Execution of work covered under CPWD Horticulture 2020 ver-2 with all correction slips
up-to-date.Rate including GST @ 18%
Item- 1 Horticulture & Landscaping Works Building No. 21 and 18/1, 18/2, 11/1 and 11/2.
S No. Item No Description of Item Unit Qty Rate Amount
2.0 HORTICUTURE AND LANDSCAPING
2.33 Providing and laying Neelgiri/Mexican Sqm 600 214.4 128640
grass turf with earth 50mm to 60mm
thickness of existing ground prepared with
proper level and ramming with tools
wooden (Dhurmos) and then rolling the
surface with light roller make the surface
smoothen and light waterning with
sprinkler and maintenance for 30 days or
more till the grass establish properly, as
per direction of officer-in-charge
5.0 ORNAMENTAL PLANTS
5.12 Providing and Displaying Bougainvillea Each 60 322.9 19374
named variety, Sobhra, Thima, Marry
palmar, Cherry Blossom etc. well
2 developed with fresh & healthy bushy in
full bloom 75 to 90 cm ht. in 40 cm
Cement Pot as per direction of the officer-
SER-GRC-ENGINEERING/SOUTH EASTERN RLY
5.30 Providing and Displaying Foxtail palm well Each 80 1183.9 94712
developed with fresh & healthy foliage of
ht. 210 to 240 cm in big 40 cm Cement Pot
as per direction of the officer-in-charge.
6.0 GROUND COVERS PLANTS
6.12 Providing and stacking of Duranta Golden, Each 800 20 16000
having ht.15 to 20 cm bushty shape with
4 fresh and healthy leaves in 15 cm size of
Earthen Pot/Plastic Pot & as per direction
of the officer-in-charge.
6.15 Providing and stacking of Ipomea (Golden Each 800 20 16000
leaves),with fresh and healthy leaves in 15
cm size of Earthen Pot/Plastic Pot & as per
direction of the officer-in-charge.
6.25 Providing and stacking of Syngonium Each 200 30 6000
(Butterfly) variegated with 2-3 suckers
6 healthy foliage in Earthen Pot/Plastic Pot
of size 20 cm. as per direction of the
officer-in-charge.
7.0 TREE PLANTS
7.1 Providing and stacking of Acacia Each 400 65 26000
auriculiformis of ht 150-165 cm in bag size
of 25 cm as per direction of the officer-in-
7.11 Providing and stacking of Bottle palm of Each 200 350 70000
ht. 210-240 cm bottom girth 30-35 cm
well developed in big HDPE bags as per
the direction of Officer in charge.
7.27 Providing and stacking of Ficus benjamina Each 80 180 14400
(green) of height 150-165 cm., bushy with
9 healthy branches and lush green foliage in
big size HDPE bags as per direction of the
officer-in-charge.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .