| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC | ₹1.6 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹1.7 Cr+₹6.8 L (4.24%)Rejected-Finance PEMASAR ROAD WARD NO 04 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | ₹1.7 Cr+₹6.8 L (4.24%) | L2 | Rejected-Finance High Rate Quoted |
| 3 | L3₹1.7 Cr+₹14.4 L (9.02%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹1.7 Cr+₹14.4 L (9.02%) | L3 | Rejected-Finance High Rate Quoted |
| 4 | L4₹2.0 Cr+₹40.0 L (25.0%)Rejected-Finance H NO 327 KRISHNA ENCLAVE HIMMATGARH PO DHAKOLI ZIRAKPUR 140603 | S A S NAGAR | PUNJAB | 140603 | ₹2.0 Cr+₹40.0 L (25.0%) | L4 | Rejected-Finance High Rate Quoted |
| 5 | Rejected-Technical BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | - | - | Rejected-Technical Not recommended for being two class below |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
16 Jan 2024, 6:00 pmClosed
Col Shery Goel, CWE Bikaner
HQ CWE Bikaner, Bikaner Mil Stn
Provn of Single JCOs Accn at various locations using 3D printing technology under GE N Bikaner at Bikaner Mil Stn
2023_MES_629274_1
CA No CWE BKN-Token No. 34/2023-2024
Open Tender
Civil Works
Lump-sum
240 days
GE N BIKANER
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE (N) Bikaner
₹2.2 L
Yes
4 Mar 2024
21 Nov 2023
22 Jan 2024
21 Nov 2023
16 Jan 2024
30 Dec 2023
Amount
SCHEDULE 'A' SECTION-I (BUILDINGS/STRUCTURE WORKS)
Construction of block of ‘SINGLE ACCN FOR 03 JCOS WITH SCOOTER/CAR PARKING SHED (D/S)’ using 3D printing technology complete all as specified in tender documents.
Construction of block of ‘SINGLE ACCN FOR 04 JCOS WITH SCOOTER/CAR PARKING SHED (D/S)’ using 3D printing technology complete all as specified in tender documents.
(Note for serial item No. 2 & 3 contd…) NOTE: (a) Serial item No 2 & 3, Schedule ‘A’ Part I is not Prepriced by MES. Bidder shall insert their rates in green field under colum 06 of BOQ. (b) The contractor has to prepare and design structural drawing complete in all respect as specified in Schedule 'A' Notes of tender document. Buildings are to be designed and constructed partly by conventional method and partly by 3D Printing technology. 3D printing technology-based work shall be construction of wall from plinth beam top to slab bottom at GF and slab top to roof bottom at FF while footing, columns upto roof slab & plinth beam, lintels over doors and windows shall be as per conventional method i.e RCC construction. (c) 3D printing work shall cover all parts in a manner such that no grooves and/or gaps remain between wall and beam and between wall and column.
(Note for serial item No. 2 & 3 contd…) NOTE: (d) The contractor shall also prepare 3D printing construction methodology report specifying complete work process of 3D printing technology including amalgamating the framed structure alongwith detailed specification of 3D printable wall such as details/ dimensions of wall thickness, layer height details in the wall, layer width details, composition of concrete 3D printable mix per cubic meter details with OPC grade, fly ash, sand, water details, super plasticizers, viscosity, fibers, 3D print wall reinforcement details, steel wire mesh reinforcements thickness details if any, reinforcement spacing details as applicable and all other details required for successful completion of work. (e) 3D print wall shall have total thickness of 230mm with inner & outer walls thickness of 50mm with maximum cavity thickness 130mm. (f) The contractor shall get all structural drawings and 3D print methodology report vetted from any of the major IIT and submit to GE (N) Bikaner for approval of Accepting Officer within the specified timeframes.
(Note for serial item No. 2 & 3 contd…) NOTE: (g) The quoted rate shall involve cost of survey, preparation and design of structural drawing based on 3D print wall, vetting of structural drawing from IIT, cost of 3D print methodology report & vetting of the same from IIT. Nothing extra cost shall be admissible on this account. (h) The contractor will be required to enter into MOU for 3D printing part of construction and cost pertaining to this shall be included in the quoted rates by the contractor. Please refer Sch 'A' Notes for further details. (j) 3D printable wall shall enable better thermal insulation and better acoustic properties then flyash brick wall being utilised earstwhile construction. (k) An authorized qualified aqainted with 3D printing work person of the vendor/thrid party hired for 3D printing work shall be made available by the contractor at site in addition to requisite manpower of 3D printing work during construction for coordination with the department for smooth execution of the work including supervision of 3D printing work at site at every stage of work.
(Note for serial item No. 2 & 3 contd…) NOTE: (l) The 3D print wall shall be compatible to mechanical, electrical and plumbing systems to be accommodated in the building and accordingly the walls shall be constructed and the same is to be taken into account while preparing and designing drawings. (m) The contractor/third party shall be fully responsible for look after of complete tools, equipment and plants required for 3D printing work. No claim whatsover on any account on part of expenses incurred on maintenance and otherwise on T&P will be admissible. (n) 3D print wall construction shall be cast-in-situ and not pre fabricated/construced wall panel/modules. (o) The contractor shall read complete Sch 'A' Notes before quoting the amount. No claim for any confusion/ mistake / error / misunderstanding will be admissible.
Subtotal (Total of Schedule 'A' Section-I)
SCHEDULE ‘A’ SECTION-II (PART-I) (INTERNAL WATER SUPPLY WORKS)
Lump sum price worked out by the Contractor for “Internal Water Supply Works” as listed in Schedule ‘A’ Section-II (Part-I).
SCHEDULE ‘A’ SECTION-II (PART-II) (INTERNAL WATER SUPPLY WORKS)
Supply & fixing 15mm bore Angle stop valve, fancy type with long shank and cup (concealed type) of cast copper alloy chromium plated, screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified & as directed.
S&F wall mixer, brass, chromium plated, fancy type, with capstan head handles with lettered 'hot' and 'cold', screwed down high pressure, including CP brass wall flanges and necessary extension nipples screwed for 15mm bore pipe connection, complete all as specified as directed. Make : Cat Part No. ‘G4916A1’ of ‘Parryware’ / Cat Part No. ‘F2002401’ of ‘Cera’ / Cat Part No. ‘CQT-23281UPR’ of ‘Jaquar’ / Cat Part No. ‘9275’ of ‘Prayag’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
S&F Centre hole mixer for mixing hot & cold water for wash hand basin, cast copper alloy, with dual capstan heads, chromium plated, screwed down high pressure, with lettered 'Hot' & 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe suitable for 15mm bore, complete all as specified as directed. Make : Cat Part No. ‘G4914A1’ of ‘Parryware’ / Cat Part No. ‘F2002461’ of ‘Cera’ / Cat Part No. ‘CQT-23167B’ of ‘Jaquar’ / Cat Part No. ‘9250’ of ‘Prayag’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
Subtotal {Total of Schedule 'A' Section-II (Part-II)}
SCHEDULE ‘A’ SECTION-III (PART-I) (INTERNAL ELECTRIFICATION WORKS)
Lump sum price worked out by the Contractor for “Internal Electrification Works” as listed in Schedule ‘A’ Section-III (Part-I).
SCHEDULE ‘A’ SECTION-III (PART-II) (INTERNAL ELECTRIFICATION WORKS)
Material & labour for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium grade, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new sunk type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed. Note : (i) Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall be deemed for include for modular metal flush boxes of requisite module and modular cover plate with frame of requisite module of colour as approved by GE.
All as per serial item No. 15.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches.
All as per serial item No. 15.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
All as per serial item No. 15.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
All as per serial item No. 15.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 5 watt, 220 Volt AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & as directed.
S&F LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ ceiling rose, complete all as specified and as directed. Make : Philips, Cat Part No. LED 20S PSU CW GR S2/ Crompton Greaves, Cat Part No. LDDR20-CDL Dazzle Ray/ Bajaj, Cat Part No. BCLAB 20W or equivalent make here-in-after in appendix 'B'
Supply and fixing LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder and connecting up with three core flexible copper conductor cable of suitable size complete all as specified & as directed.
Supply, installation, commissioning & testing Light Emitting Diode (LED) based street/security light fitting, 35 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, system luminous efficacy of minimum 100 lumens per watt and a minimum system lumen output of not less than 3500 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), complete all as specified and as directed.
NOTES FOR LED LIGHT FITTINGS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a on site replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
Supply and fixing wall mounting bracket (suitable for fixing/ holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 1.20m long, bent to shape at required angle, fixed to wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, complete all as specified and as directed.
Supply and fixing MCB, 6 to 32 Amps, Single Pole & Neutral, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed.
Supply and fixing MCB, 6 to 32 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed.
Supply and fixing MCCB, 4 Pole, 63 Amps, rupturing capacity 16 KA, 415 Volt grade, AC, 50 Hz, fixed Thermal - Magnetic, complete all as specified and as directed.
Supply & fixing sheet metal enclosure, double door type, suitable for fixing MCBs, Vertical TPN with 200 Amps rated copper bus bar, 4 way, 415 Volts, complete all as specified and as directed.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLSH with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling complete all as specified & as directed. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
Supply, assembling, hanging, fixing & testing Ceiling Fan of size 1200 mm sweep, minimum air delivery 210 CMM with service value 6.00 BEE, 5 star rated, with brushless direct current (BLDC) motor, single phase, AC supply, 230 Volt, with & including down rod, canopies, three number blades, capacitor 2.5 mfd, hook, rubber reel, safety pins, nuts, bolts, washers, cable connector and making connection with PVC insulated & sheathed 1 Sqmm three core flexible copper multistranded conductor cable (ISI marked) from ceiling rose to connector of ceiling fan including marking of SM / MES number with thick synthetic enamel paint of approved tint complete all as specified and as directed. Note :- The font, style & place of writing SM/ MES number with synthetic enamel paint on ceiling fan shall be as directed by the Engineer-in-Charge and cost thereof shall deemed to be included in quoted rates.
Supply and fixing Exhaust Fan made of sturdy Engineering plastic complete with louvers shutter, 300mm sweep, 230V, 50 Hz, 1200 RPM, Copper winding and connecting with & including 1 Sqmm, three core, flexible multistranded copper conductor cable and connected from ceiling rose to fan complete all as specified & as directed.
Material and labour Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI wire 4 mm dia (upto the test point / cross arms earth lead upto 7.5 meter length from top of earth plate) by means of GI bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, Pit cover & frame including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part-I. Notes :- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earth lead upto 7.5 meter length from top of earth plate.
Supply, installation & testing electric Geyser (water storage type) of capacity 25 litre, vertical mounting type, glass lined inner tank, rust proof outer body, 2 KW heating element, suitable for 230V Single Phase 50 Hz AC supply, BEE 5 Star rating, energy efficient, 8 Kg/sqcm pressure withstanding capacity, Class I, ISI marked, with & including Thermostat with Thermal Cutout, heating indicator, Multi functional valve (acts as pressure release valve, non-return valve, expansion valve and vacuum release valve), fixed all as per manufacturer’s instructions, fixed with & including ‘Anchor’ type /fastener type bolts & nuts (Set of 4 bolts of 12mm dia 200mm long with nuts & washers) into the wall grouted properly to hold the geyser complete all as specified & as directed.
S&F Evaporative Air Cooler in steel body (Desert Cooler) with propeller type cooler fan with motor (ISI marked) 1400 RPM (4 Pole) three speeds, nominal capacity 4000 Cum/hour, fan size 450mm, type of blade - Plastic (HIP), submersible water pump, filter pads, power consumption - 225 Watts (maximum), electric driven, single phase, 230 Volts, 50 Hz, capacitor 4 mfd, including all accessories, complete all as specified & as directed. Notes :- (i) Filter panels, front, grill and top of the cooler body shall be made of 0.80 mm galvanized steel sheet. The sump tank and rest of the body shall be made of 1.00 mm thick galvanized steel sheet. The galvanised steel sheet shall be ISI marked and shall have zinc coating not less than 100 gms/sqm and shall conform to IS : 277. (ii) All internal surfaces including inside of the tank, fan blades, motor body, pump, pump body and frame shall be painted with water resistant paint conforming to IS: 9862. The outer surface of the cooler shall be spray painted with synthetic enamel paint of approved shade/tint. (iii) The desert cooler shall be fitted with adjustable grill with separate on/off switch of 5/6 Amp rating (ISI marked) for cooler fan and water pump and three stage speed regulator (Low, Medium, High) for three speed cooler fan motor. (Description of serial item No. 34.00 contd…)
Description of serial item No. 34.00 contd… (iv) Suitable nylon bushes shall be provided in the grill for easy and smooth movement of louvers. (v) The filter pads shall contain wood wool. The filter pads shall be fixed over the panel and secured by clamping guard of galvanized wire of 2mm dia (approx.) and net size 100 mm (approx.) square/rectangular. The wire guard shall be fixed in the clamps to avoid any sagging. (vi) The drain plug of brass/stainless steel shall be fitted in such a way so as to be able to completely drain the water from the tank. (vii) The inside wiring connection shall be through suitable non-ferrous thimbles and the live contacts of rotary switch shall be protected by suitable enclosure of insulating material. The electrical cords of the motor and the pump shall be sheathed type. (viii) The cooler shall be provided with front filling arrangement and with 3 core copper stranded conductor size 23/0.0076 cable connecting cord (ISI marked) of 2.50 mtrs length fitted with 3 pin moulded plug top of 5/6 Amp rating (ISI marked). (Description of serial item No. 34.01 contd…)
Description of serial item No. 34.01 contd… (ix) PVC pipe 15mm bore shall be heavy duty high density. (x) Overall minimum dimensions including water tank (sump) of the cooler shall be as under :- (a) Width – 660 mm (measured at front side) (b) Height – 860 mm (measured at front side) (c) Depth – 660 mm (d) Height of water tank – 228 mm (xi) Cooler fan with motor and submersible pump shall be of make :- Khaitan / Usha / Bajaj / GEC / Crompton / Orient / Polar / Havells. Makes of other material such as switches, copper cord etc shall be as specified in Particular specifications / Appendices. (xii) Above aspects shall deemed to be included in quoted rates.
Subtotal {Total of Schedule 'A' Section-III (Part-II)}
SCHEDULE 'A' SECTION-IV (PART-I) (ROAD/ PATH/ CULVERT WORKS)
Lump sum price worked out by the Contractor for “Road/ Path/ Culvert Works” as listed in Schedule ‘A’ Section-IV (Part-I).
SCHEDULE 'A' SECTION-IV (PART-II) (ROAD/ PATH/ CULVERT WORKS)
Material & labour for precast cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in Kerb stone blocks (factory casted) with plain fair faces, including weathering, slightly rounded or chamfered angle throating, with plain or interlocking joints and setting in cement mortar 1:4, complete all as specified and as directed. Note : Shape & size of Kerb blocks shall be as approved by the GE.
M&L for preparation of old plastered sufaces or concrete surfaces in road side path/ kerbs of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
M&L for preparation of newly concrete surfaces in road side path/ kerbs of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
Material & labour for 110mm bore PVC (SWR) pipes single socketed in any length laid under floors, through walls, path and as in weep holes and the like in staggered way complete all as specified & as directed.
Subtotal {Total of Schedule 'A' Section-IV (Part-II)}
SCHEDULE 'A' SECTION-V (AREA DRAINAGE WORKS)
Lump sum price worked out by the Contractor for “Area Drainage Works” as listed in Schedule ‘A’ Section-V.
SCHEDULE 'A' SECTION-VI (PART-I) (SEWAGE DISPOSAL WORKS)
Lump sum price worked out by the Contractor for “Sewage Disposal Works” as listed in Schedule ‘A’ Section-VI (Part-I).
SCHEDULE 'A' SECTION-VI (PART-II) (SEWAGE DISPOSAL WORKS)
M&L for construction of Septic Tank for 10 users, brick construction, complete, all as specified and shown on drawings (BTD-016 Sheet No. 1/3 to 3/3).
M&L for construction of Soak Well for 25 users, brick masonry, complete, all as specified and shown on drawings (BTD-830 Sheet No. 1/1).
SCHEDULE 'A' SECTION-VII (PART-I) (EXTERNAL WATER SUPPLY WORKS)
Lump sum price worked out by the Contractor for “External Water Supply Works” as listed in Schedule ‘A’ Section-VII (Part-I).
SCHEDULE ‘A’ SECTION-VII (PART-II) (EXTERNAL WATER SUPPLY WORKS)
Cutting existing steel tubing for alterations or additions (Each cut measured), necessarily done in position without taking down, 80 or 100mm bore pipe complete all as specified & as directed.
Boring holes under main road, pavements, hardstanding by trenchless technology using ultra sound technique and necessary machine for accommodating upto 150 mm bore pipe including all necessary returning filling & removal of surplus soil upto 50 m distance complete all as directed. Note : Pipe shall be measured & paid for separately under respective item of BoQ/Schedule 'A'.
M&L for Valve Pit of internal size 90cm x 90cm x 90cm built in brick masonry complete all as specified in Particular Specifications and as shown on drawing No. BTD-811 Sheet No. 1/2 & 2/2 .
Subtotal {Total of Schedule 'A' Section-VII (Part-II)}
SCHEDULE 'A' SECTION-VIII (PART-I) (EXTERNAL ELECTRIC SUPPLY WORKS)
Lump sum price worked out by the Contractor for “External Electric Supply Works” as listed in Schedule ‘A’ Section-VIII (Part-I).
SCHEDULE 'A' SECTION-VIII (PART-II) (EXTERNAL ELECTRIC SUPPLY WORKS)
Material & labour for sand cushioning using clean local Tibba fine sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. Note :- Punned thickness shall be considered for payment purpose.
Supplying and laying factory made un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm confirming to IS-5820 complete all as specified and as directed.
Material & labour for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of electric cable complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.
Boring holes under main road, pavements, hardstanding by trenchless technology using ultra sound technique and necessary machine for accommodating upto 80mm bore pipe including all necessary returning filling & removal of surplus soil upto 50 m distance complete all as directed. Note : Pipe shall be measured & paid for separately under respective item of BoQ/Schedule 'A'.
S&F cable jointing kit for LV/LT 1100 volt grade cable for indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm complete all as specified and directed.
M&L for Earthing to panels with & including galvanised mild steel earth plate electrode of size 60cm x 60cm x 6mm thick buried vertically in ground (earth pit not less than 2.25m below normal ground level) with top edge of the earth plate at a depth not less than 1.5m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/ welded to earth plate at one end and other end of strip connected to Panel with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
Supply, installation, testing and commissioning factory LT Panel, indoor type (cubical type), suitable for 415 volts 3 phase & neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars of 200 Amps rating with 3 phase & neutral installed on porcelain insulators with bus bar chamber shall be provided with inspection covers. The panel shall be dust & vermin proof, protection class IP-65 and made out of CRCA sheet of 2mm thick, powder coated finish on outside & inside surfaces (approved shade), double door (front & rear), in two shalves with provision of rubber beading and front opening type with aprons for cable entry, with double door shutter & locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, dange notice board in front and rear sides, including two coats of synthetic enamel paint over a coat of red oxide primer, pedestal frame grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) including internal wiring with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 6 sqmm with proper ferrule & cable gland complete and also comprising of the following:- (Description of serial item No. 67.00 contd…)
Subtotal {Total of Schedule 'A' Section-VIII (Part-II)}
SCHEDULE 'A' SECTION-IX (EXCAVATION AND EARTH WORK)
Lump sum price worked out by the Contractor for “Excavation and Earth Work” as listed in Schedule ‘A’ Section-IX.
SUBHAM ENTERPRISES
M/s Rohit Construction Co.
G S BUILDERS AND ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .