Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC 216 BHARAT NAGAR INDRAPURI BHOPAL MADHYA PRADESH 462021 | BHOPAL | MADHYA PRADESH | 462021 | ₹1.5 Cr | L1 | Accepted-AOC The Lowest Bidder |
| 2 | L2₹1.6 Cr+₹3.1 L (2.03%)Rejected-Finance | ₹1.6 Cr+₹3.1 L (2.03%) | L2 | Rejected-Finance Not the lowest e-tenderer |
| 3 | L3₹1.6 Cr+₹4.6 L (3.02%)Rejected-Finance 9 8 B THENGUMTHARAVIL MLA ROAD PANANGAD PO KOCHI 682506 | KOCHI | ERNAKULAM | KERALA | 682506 | ₹1.6 Cr+₹4.6 L (3.02%) | L3 | Rejected-Finance Not the lowest e-tenderer |
| 4 | L4₹1.7 Cr+₹16.6 L (10.9%)Rejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | NEW DELHI | DELHI | 110019 | ₹1.7 Cr+₹16.6 L (10.9%) | L4 | Rejected-Finance Not the lowest e-tenderer |
| 5 | L5₹1.8 Cr+₹27.8 L (18.2%)Rejected-Finance S NO 41 4K JAIHIND SOCIETY GANESH NAGAR NEAR ANAND PARK VADGAON SHERI PUNE 411 014 | PUNE | PUNE | MAHARASHTRA | 411014 | ₹1.8 Cr+₹27.8 L (18.2%) | L5 | Rejected-Finance Not the lowest e-tenderer |
Tender Value
₹1.6 Cr
EMD Value
₹2.4 L
Closing Date
12 Jan 2022, 6:00 pmClosed
Col Santosh Pandey
Commander Works Engineer (Army) Mumbai 24 Assaye Building Colaba Mumbai-400005
PROVN OF FIRE FIGHTING AND FIRE ALARM AND DETECTION SYSTEM AT MH PANAJI GOA
2021_MES_495317_4
84068/P/E8
Open Tender
Civil Works
Item Rate
90 days
Garriosn Engineer Panaji Goa
Please Refer Tender Documents
7 documents required · 7 mandatory
₹1,000
Garriosn Engineer Panaji Goa
₹2.4 L
11 Feb 2022
6 Jan 2022
13 Jan 2022
6 Jan 2022
12 Jan 2022
7 Jan 2022
6 Jan 2022 - 12 Jan 2022
Amount
S & F ICV / Alarm gong (Intermittent hydraulic alarm with alarm gong and water motor Alarm) 100 mm connected including all necessary fittings, valves, strainer, pressure gauges and connected GI pipe heavy grade with all fittings and accessories required at site complete all as specified and as directed
S & F of pressure gauge 0 to 14 Kg/cm square range with necessary siphon and 15 mm dia stop valve including 15 mm dia GI pipe, not exceeding 0.25 Mtr in length on rising main including drilling tapping on GI / CI /MS pipe line complete all as specified and directed. Make- Waarrie/H-Guru
S & F High pressure switch spring actuated type, range 8 - 32 kg/sqcm fixed to existing pipe including taping, welding and connected control valves, GI pipe heavy grade and MS specials like nipples, sockets etc of suitable size required at site and testing all as specified and as directed.
S & F Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and as directed
S & F Sprinkler glass bulb type (Standard response) as per IS:15106/TAC guidelines 68 degree temperature rating pendent type including all fixing accessories like connector piece, nipples, sockets etc and testing complete all as specified and as directed.
S & F Sprinkler rossette 25mm dia fixed including necessary fixing arrangements required at site complete all as specified and as directed
S & F Sprinkler flexible pipe 1m including all necessary fixing arrangements required at site complete all as specified and as directed
S & F Vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 80 mm dia, having following features. a.Visual switch activation. b.Rugged switch assembly. c.Heavy duty alluminium pipe saddles. d.Durable metal encloser. e.Steel U bolts for secure mounting. f.Two SPDT (single pole double track) synchronised switches. g.Serviceable without draining pipes.
S & F ERW (Electric Resistance Welded) pipes having nominal bore of 25 mm, heavy duty 4.05 mm thick with plain ends confirming to IS 1239 (Part-1)-2004, cutting, welding, jointing etc complete all as per site requirement and as specified and directed.
S & F ERW (Electric Resistance Welded) pipes having nominal bore of 32 mm, heavy duty 4.05 mm thick with plain ends confirming to IS 1239 (Part-1)-2004, cutting, welding, jointing etc complete all as per site requirement and as specified and directed.
S & F ERW (Electric Resistance Welded) pipes having nominal bore of 40 mm, heavy duty 4.05 mm thick with plain ends confirming to IS 1239 (Part-1)-2004, cutting, welding, jointing etc complete all as per site requirement and as specified and directed.
S & F ERW (Electric Resistance Welded) pipes having nominal bore of 50 mm, heavy duty 4.47 mm thick with plain ends confirming to IS 1239 (Part-1)-2004, cutting, welding, jointing etc complete all as per site requirement and as specified and directed.
S & F ERW (Electric Resistance Welded) pipes having nominal bore of 65 mm, heavy duty 4.47 mm thick with plain ends confirming to IS 1239 (Part-1)-2004, cutting, welding, jointing etc complete all as per site requirement and as specified and directed.
S & F ERW (Electric Resistance Welded) pipes having nominal bore of 80 mm, heavy duty 4.85 mm thick with plain ends confirming to IS 1239 (Part-1)-2004, cutting, welding, jointing etc complete all as per site requirement and as specified and directed.
S & F ERW (Electric Resistance Welded) pipes having nominal bore of 100 mm, heavy duty 5.4 mm thick with plain ends confirming to IS 1239 (Part-1)-2004, cutting, welding, jointing etc complete all as per site requirement and as specified and directed.
S & F ERW (Electric Resistance Welded) pipes having nominal bore of 150 mm, heavy duty 6 mm thick with plain ends confirming to IS 1239 (Part-1)-2004, cutting, welding, jointing etc complete all as per site requirement and as specified and directed Make for Item No. 9 to 16- Jindal/Tata/Surya Prakash
S & F 100 mm dia end line strainer for negative suction complete all as specified andn as directed.
S & F Cast iron body butterfly valve PN-16 ISI marked, heavy duty suitable to fix MS/GI pipe in any position of size 50 mm dia including fixing arrangements as required at site including necessary Bolts, Nuts and rubber packings etc complete all as specified and as directed
S & F Cast iron body butterfly valve PN-16 ISI marked, heavy duty suitable to fix MS/GI pipe in any position of size 100 mm dia including fixing arrangements as required at site including necessary Bolts, Nuts and rubber packings etc complete all as specified and as directed
S & F Cast iron body butterfly valve PN-16 ISI marked, heavy duty suitable to fix MS/GI pipe in any position of size150 mm dia including fixing arrangements as required at site including necessary Bolts, Nuts and rubber packings etc complete all as specified and as directed Make for Item No. 18 to 20- (a) Leader (b) Kirloskar (c) Upadhyay (iv) L&T (v) Zoloto (vi) Bir
Dismantling of Wall and ceiling boards (Fibre, pulp, insulation boards/ slabs/blankets any thickness, including cover fillets and false ceiling and stacking at site for reuse etc complete all as directed
Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200mm/600mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c. The Main Runners to be placed @ 1200mm, The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600mm x 600mm. Grid of module size 600mm x 600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit complete as specified & directed by Engineer-in-charge. Make : (a) Everest (b) Armstrong
S & F 6 mm thick calcium silicate board made with calcareous & siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sqcm, bending strength 100 kg/sqcm, tapered edge, fixing to ceiling section and perimeter channel using dry wall screws of size 3.5 mm X 25 mm at 230 mm c/c including jointing and finishing to a flush finish of tapered edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint including one coat of primer and one coat of CBP as finishes complete all as specified and as directed. Make : (a) Everest (b) Armstrong (c) Supra (d) Hilux (e) RAMCO (f) Deckelite India
Labour only for Anodised aluminium snap grid frame work removed against item sl No- 21 of above for false ceiling all as specified and as directed.
Supply, install, commissioning and testing electric motor driven fire pump set, horizontal end suction pump type DB capable of delivering 2280 LPM of water at head 33 metre head with pump casing of cast iron of grade FG 2000 conforming to IS :210 -1979 including impellar, sleeve, wearing ring of gun metal bronze / double bronze impeller, stainless steel shaft, flexible coupling, coupling guard base frame, mechnical sealed bearing to withstand pressure 3.5 kg/cm2 & squirrel cage AC induction motor Conforming to IS :325-1978 with class ' B' Insulation, TEFC lP-21 protection as per IS :4691-1968 ,1500 RPM, continuous duty, 415 V +/- 10% ,50 HZ ,3 Phase, AC having suitable HP rating capable of giving 150% of rated discharge at a head not less than 65% of the rated discharge suitable suction / delivery of size, Common base plate made out of MS channel of suitable size for assembling the pump & motor, flexible coupling & with coupling guard for protection/safety with and including foundation bolts, PCC 1:2:4 type B1 using 20 mm graded stone aggregates as per recommendations of manufacturer, excavation and earthwork, suitable size of fully automatic star delta starter with mounting stand of angle iron size 50 mm x 50 mm x 5 mm thick painted with two coats aluminium paint over a coat of aluminum primer and suitable size of electric connection PVC insulated multistranded copper cable in flexible counduit from MCCB to starter and starter to pump motor complete all as specified and directed. Make- Kirloskar
Supply and install double flanged non return valve, Swing check-up, Single door pressue upto 1.6 PN conforming to IS: 5312 (Part I) having cast iron body & gun metal working parts with nut, bolts, gaskets etc and tested to 1.5 times of working pressure as approved of following sizes of reflux with by pass arrangement complete all as specified & directed for:- (a) 150 mm dia
Supply and fix gun metal branch pipe with nozzle 12.5 mm dia at one end & 63 mm bore with instantaneous type coupling at other end all conforming to IS: 903 complete all as specified & directed.
Supply and fix gun metal, 63 mm dia, short size branch pipe with 20 mm dia nozzles with 63 mm instantaneous coupling ISI marked as per IS: 903 complete all as specified & directed.
S & F landing valve, type 'A' hydrant with 63 mm dia with Single flanged end pillar pattern conforming to IS 5290, instantaneous spring lock type gunmetal female coupling double headed outlets with blank cap and chains complete suitable for 63 mm dia fire hose pipe connection including welded branch connection etc complete all as specified & directed. Make for Item No. 26 to 29- (a) Leader (b) BIR (c) Kirloskar (d) Sant (e) Upadhyay (f) L & T
Supply and Install wall mounting, Swinging hose reel drum as per IS 884 and fitted with 25 mm dia 30 meter long high pressure polyproplene (Polyhose) pipe high pressure as per IS: 444 (Type III) Gun metal chrome plated nozzle and 25 mm dia gun metal gate valve on the inlet pipe with necessary MS Bracket for holding Hose reel drum fitted in position with wall fasteners, etc as approved complete all as specified & directed.
S & F cast iron non return valve with ball and gasket made of neoprene type rubber scaling ring made of loaded in bronze 50mm dia with by pass arrangement complete all as specified and directed.
S & F cast iron non return valve with ball and gasket made of neoprene type rubber scaling ring made of loaded in bronze 100mm dia with by pass arrangement complete all as specified and directed.
Supply and fix CI foot valve leather sheet type/flange type of size 80 mm dia including jointing materials etc complete all as specified and directed.
Supply and fix CI foot valve leather sheet type/flange type of size 150 mm dia including jointing materials etc complete all as specified and directed.
S & F Air release valve, ISI marked heavy grade of size 25 mm, fixed to existing pipe line of any size and type by boring, taping, welding and inserting suitable MS insertion and required MS specials including provn of check valve and testing complete all as specified and as directed. Make for Item No. 31 to 35- (a) Leader (b) BIR (c) Kirloskar (d) Sant (e) Upadhyay (f) L & T
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 5000 litres capacity hoisted and fixed in position including float valve, 40 mm dia outlet gate valve with necessary GI piping up to delivery of pump, inlet piping, overflow pipe, air vent pipe etc complete all as specified and directed. Make- (i) M/s Sintex (ii) M/s Infra (iii) M/s Ashish Plast (iv) M/s Yash Engineering Works, Pune 09422007879 (v) M/s Plasto (vi) Polycon
M & L for auto starting electric control panel (MCC) for pumpsets star delta starter with required cabling from panel to both pump motors as per TAC requirements & approval, the control panel should have logic such that, in event of any house reel or landing valve is opened then the pressure in the line drops and the pressure switches installed on the pump manifold give the indication for the jocky pump to start, if more than one landing valves are opened then as sufficient pressure is not build up in the line by jocky pump, hence it will stop and main pump starts complete all as specified and directed.
Supply and erecting and terminating PVC armoured cable 4 Core X 6 Sqmm copper conductor with continious 12 swg GI earth wire complete errected with glands and lugs on wall/trusses/pole/or laid in protected trench/ pipe as per specification. Make- (a) Cable Corporation of India, Mumbai (b) Asian Cable Co, Chattisgarh (c) Finolex Cable Ltd, Pune (d) Polycab (e) Gloster (f) Universal (g) RPG Cables Ltd , Thane (h) Havells India Ltd (i) RR Kabel (j) KEI Industries Ltd(KEI)
S & F Photo electric smoke / heat / optical detector, conventional type, size not less than 10 mm dia, 46 mm height with base, weight not less than 130 gm per set with base, operating voltage 24 V, operating temp 0 degree to 50 degree Celcius , humidity range 0-95% RH non condensing current drawn on alarm 3.5 MA, standby current 35 MA maximum sensitivity 2.66 +1.11% obscuration conforming to CE and EN 54 standards, fixed complete to RCC ceiling inside the building including all fixing materials junction box etc, as required at site complete all as specified & directed.
S & F fire alarm panel, suitable for four zones, i.e. 4 No's alarm initiating circuits, type class 'A‘ or 'B' end of line 3.9 K, loop powered device current 1.8A Alarm current 500 mA, double out puts. (i) Alarm relay, change over voltage free contacts. (ii) Fault relay change over voltage free contacts, duly monitored by means of (i) Line for sounders (ii) Auxillary power out put having autonomy with and including 2 No 12 Volts 7 AH batteries and terminals etc (i) 12 hours on standby and (ii) 30 minutes in alarm condition detection lines duly protected from short circuiting, suitable for audio and visual alarm indications, power input 230 volts AC + 15% 50/60 HZ, optional standby power 24 V DC through batteries, panel conforming to CE and EN-54 part 2 & 4 standards, complete conforming to CE and EN-54 part 2 & 4 standards, complete assembly housed in a steel housing with hinged removable locking door and having paints finish make CATEC model No XF—C or equivalent make lSl marked, fixed complete inside the control station including all fixing material as required at site complete all as specified and directed.
S & F Manual Call point, wall mounting type, made of cast aluminium signal red finish suitable for operation on 24 volts DC , ISI marked or conforming to IS- 2189, including all fixing material as required at site, complete all as specified and directed.
S & F Hooter 40 W suitable for 12-24 Volts DC working upto 30 V (for max 30 minutes), having max current consumption of 70 mA, sound pressure level 100 db minimum + 2 at 100 cm at 12 V for tone 5, operating temp 20 Deg to 70 Deg C, conforming to VDS (German) or CE(European) Registration standards, housing material ABS 20 with white RAL 9003 I signal red RAL 3001 finish, with lP-54 environmental protection, of standard make lSl marked to be installed over the SIM Hall including all fixing material as required at site complete all as specified & as directed.
Supply and lay FRLS copper conductor PVC insulated PVC sheathed cable 1.5 sqmm, 2 Core for complete fire alarm system between and different rooms above false ceiling / level drawn into and including saddles and all other material required for layiing / fixing complete all as specified and as directed. Make- (a) Cable Corporation of India, Mumbai (b) Asian Cable Co, Chattisgarh (c) Finolex Cable Ltd, Pune (d) Polycab (e) Gloster (f) Universal (g) RPG Cables Ltd , Thane (h) Havells India Ltd (i) RR Kabel (j) KEI Industries Ltd(KEI)
Supply, installation, testing and commissioning of Gas leak detection system to find out leakage of LPG fas at the premises of Cook house/Cafeteria and covered upto the area of 30 Sqm complete all as specified & as directed.
Supply installation, testing and commissioning of Tube trace system for the LT panel of size:W850xL320xH2360 comprising of suitable gas (clean agent), tubing , control panel, necessary detection system to detect the fire in the panel and arragement to supports the same complete all as specified & as directed.
S & F 120 Minutes Fire rated Door System for Electrical Room 1.5x2 mtr conforming of BS 476 part (20& 22), tested at CBRI. Fire door shall befitted with appropriate fir resistant fittings, such as frame and door for panel room complete all as specified & as directed.
S & F Fire stops by Hitli / Eq material in Shafts complete all as specified & as directed.
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. Capacity, conforming to IS 2878 Complete with, necessary clamp made front 50mm x 6mm. M.S. flat with nut & bolts grouted in wall complete.Make: ISI complete all as specified & as directed.
Supplying and erecting ABC powder Fire extinguisher as per IS : 15683 of 4 kg capacity with necessary clamp for erection on wall complete all as specified & as directed.
Providing & Fixing Self luminating signages for following items of (size 4" x 12") (a) Exit Signage
(b) Fire extinguisher Signage
(c) Hose reel Hose Signage
(d) Staircase Identification Signage ( up stairs)
(e) Staircase Identification Signage ( down stairs)
(f) Assembly Point Signage
(g) Fire Alarm Signage
(h) Emergency Escape Plan Signage
(i) Signages to be installed near Electrical Panel Room etc.
S & F Automatic fire detection and fire fighting system for LT panel consisting of 1 Cylinder filled with HFC 27 clean agent gas fitted with DLV, pressure gauge, pressure switch, control panel from indications suitable to work automatically with 40 m sensitive polymer base tube. Assuem gas charge of 6 kg complete all as specified & as directed.
Supply, installation, testing and commissioning and programming of NOVEC 1230 Fire Suppression System For Server Room. Volume Considered - 15 Cu.Mtr ,10 Kg Gas. Consisting of following items: Actual volume of gas required may be checked based on room size of 2.4x2.2x3 (LxBxH) = 16 Cu.Mtr a. 2 Zone Detection ,One Gas Release Module Gas Release Panel With Stand By Battery & Battery Charger. b.Multi sensor. c.Manual Release Station. d.Electronic Hooter e. 2x1.5 Sqmm Pvc Armoured FRLS Copper Cable. f.Novec gas cylinder with valve Assembly. g. Novec 1230 Gas. h.Discharge Nozzle. i.Electrical Actuater j.Manual Actuater. k. HP Delivery Hose. l. Piping - ASTM 106. Grade 'B' Seamless Pipe. m. Mounting Arrangement. n. Warning Sign. o.Testing & Commissioning.
S & F SITC of Dual Tone Ceiling mounted speaker with all recquisite mounting accessories to mount the speaker on False Ceiling / True Ceiling. (a). 6.0 Watts Ceiling mounted addressable speakers integrated with fire alarm
(b). Box type 6 watt addressable speakers integrated with fire alarm, Back Box shall be powder coated. (Wall mounted)
S & F SITC of Main PA Amplifier 500 Watt with all required accessories Make : Ahuja SSA 5000 DP
Plastic Black Microphone Fire Alarm (Mike)
S & F SITC of Equipment racks for mounting PA equipment complete with Tamper Switch to be monitored on IBMS. Racks shall be suitable for Dual power feed, and shall be complete with Redundant Cooling Fans.
Supply installation of Armoured speaker cable 1.5sqmm twisted pair multistranded. The cable shall be laid on surface with GI saddle-spacers every 0.3 meters. Complete with GI Junction Box, lugs, cable compression glands, cable tags and Ferruling. Make- (a) Cable Corporation of India (b) Asian Cable Co (c) Finolex Cable Ltd (d) Polycab (e). Gloster (f). Universal (g). RPG Cables Ltd (h) Havells india ltd (i) RR Kabel (j) KEI Industries Ltd(KEI)
Shetty Construction Co
T.I.John and Sons
SOOD ASSOCIATES PVT LTD
OM INFRA
Shree Ayyappa Engineering
M/s. P S REDDY
City Promoter and Buildwell Pvt. Ltd.
SHRI GURMUKHDAS CONTRACTORS PVT. LTD.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .