Loading…
Loading…
Tender ID
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
3 Apr 2026, 6:00 pmClosed
GE AF UDHAMPUR
GE (AF) STATION UDHAMPUR
REPAIR / REPLACEMENT OF CONVENTIONAL LIGHT FITTINGS TO LED LIGHT FITTINGS, BUILDING SECURITY LIGHT AND ITS ALLIED WORKS AT 39 WING AF STN UDHAMPUR
2026_MES_756247_1
GEAFU-87/2025-26
Open Tender
Civil Works
Works
180 days
GE (AF) STATION UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) UDHAMPUR
₹90,000
3 Apr 2026
13 Mar 2026
6 Apr 2026
13 Mar 2026
3 Apr 2026
27 Mar 2026
13 Mar 2026 - 20 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in Surface conduit with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab ] | - | - | - | - |
| 2 | One light/Fan/Exhaust fan point controlled by one switch | - | Per Point | - | - |
| 3 | S&F switch piano, flush type, 5 amps single pole, one way | - | Each | - | - |
| 4 | M&L in repair Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 1.50 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 1.50 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface concealed PVC conduit, heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Make of conductor : Havells/polycab/KEI
Note: Two runs each of 1.50 sqmm main cable and one RM of 1.50 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose. | 450 | RM | - | - |
| 5 | S&F in repair Recess mounting type fitting LED indoor luminaire powder coated, CRCA or powder coated aluminium panel 2' x 2' (Appx) system wattage 36 watt (cool white), minimum system lumen efficacy not less than 80 % , CRI not less than 80, colour temperature not less than 6000 K, power factor not less than 0.95, LED driver with constant output voltage and current at input voltage of 140volt to 285 volt AC, 50 HZ, Surge Protection>2 KV, IP protection IP 20, powder coated housing with ashthetic bottom frame, with excellent heat dissipation through high thermal conductivity, high efficiency transulence diffuser, suitable for any type of ceiling system including connection with PVC insulated copper conductor 3 core cable of 0.50 sqmm complete all as specified. | 80 | Each | - | - |
| 6 | Supply and fix in repair of building security LED street light fitting 35 Watt 6500K pf >.90 efficency 100lm/W 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp fixing of wall,pole,building with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection including suitable size bricket,clamps,fastner etc complete all as specified and as directed. | 80 | Each | - | - |
| 7 | Supply and fixing in replacement LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified including taking down old.
Make : Havells/Bajaj/C&S/Crompton | 100 | Each | - | - |
| 8 | Supply and fixing in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified including taking down old.
Make : Havells/Bajaj/C&S/Crompton | 20 | Each | - | - |
| 9 | S & F street light bracket made out of 40/50 mm dia GI heavy grade tubing not less than 1.5 Mtr long bend to shape including pole clamps made out of 50 x 6 FI and nut bolts and washers all as specified and directed including taking down old. | - | Each | - | - |
| 10 | Supply and fixing MCB Disribution 1 row 3 modules of polycarbonate themoplastic, IP 65 dust proof, jet water tight corrosion proof, halogen & silicon free, with high quality earth and neutral links, internally embedded gasket for led and enclosures made PUR with cable glands and other accessories with MCB 6 amps and required terminals, metric size knock transparent door & with cable enerty covered and suitable to accommodate any make of MCCB and tested as per IEC 60439-3 (Flame retardant self extinguishing of size 202x238x111 mm complete all as specified and directed including taking down old. Make : Hensel cat Ref No: KV 7103/legrand | - | Each | - | - |
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Tender.pdf
Tender Documents • 1.54 MB
BOQ_847094.xls
BOQ • 10.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .