Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid Value. | |
| 2 | L2₹43.1 L+₹5.1 L (13.5%)Rejected-AOC | L2 | Rejected-AOC Higher Bid Value. |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
25 Jul 2020, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE HQ TC AIR FORCE BANGALORE 560006
ADDITIONAL / ALTERATION TO DRY AND IRONING ROOM AND DHOBI GHAT, BUILDING NO P-350 AND PROVISION OF STATION STORE AND CONNECTED WORKS SERVICES AT HQTC BANGALORE
2020_MES_356365_1
8690/GE-33
Open Tender
Civil Works - Others
Item Rate
270 days
GE (AF) BANGALORE
As per Tender documents
5 documents required · 5 mandatory
₹500
Yes
GE (AF) BANGALORE
₹88,000
Yes
31 Aug 2020
27 Jun 2020
27 Jul 2020
27 Jun 2020
25 Jul 2020
13 Jul 2020
29 Jun 2020 - 7 Jul 2020
Amount
Surface dressing n exc 15 cm deep in soft/loose soil on uneven surface of natural ground filled up area, removing vegetation, scrapping high patches and filling in low patches with the scrapped soil to give and even & neat look complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5mtr wide and not exceeding 1.5 depth, for foundation, etc, or for shafts, wells, cesspits, manhole, pier holes etc not exceeding 10 Sq m on plan and not exceeding 1.5 m in depth and getting out, complete all as specified and directed..
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed.
Removal of surplus soil not exceeding 50mtr and depositing where directed at level not exceeding 1.5mtr above the starting point, complete all as specified and directed.
Removal of surplus soil not exceeding 5 KM and depositing where directed at level not exceeding 1.5mtr above the starting point, complete all as specified and directed.
Plain cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete, complete all as specified and directed.
Form work to sides and soffits of floor or roof beams, beams haunchings, girders, bressummers, lintels, cantilevers, shelves incl. supports, overhangs, etc also splays between floors and beams etc. for rough finished surfaces, complete all as specified and directed.
Providing reinforced cement concrete 1:2:4 type B-1 (Nominal mix) (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slab and in shelves and the like, complete all as specified and directed.
Mild steel TMT bars 10 mm dia and over, quality conforming to Grade Fe-500 or 550 cut to length , bent to shape required including cranking , bending spirally for hooping for columns,, hooking ends, binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
All as per srl item No 09 here in before but 5 mm dia, and over upto and including 10 mm dia in stirrups, spacers and binders etc, complete all as specified and directed.
Pre-cast cement concrete block type C1 1:3:6 (20mm graded stone aggregate) masonry with solid blocks, exc. 10cm in width and setting in mortar 1:6, complete all as specified and directed.
Providing precast cement concrete solid building blocks type C1 1:3:6 (20mm graded aggregate) 10cm thick (with plain or interlocking joints as directed) setting in mortar 1:4, complete in walls, complete all as specified and directed.
Providing cement concrete Type B-1, 1:2:4 (20 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, copings bed plates, blocks, including use of form work and finishing the cement concrete surfaces all as specified in clause 4.11.16.2(e) of MES Schedule Part-I, complete all as specified and directed.
Rendering 15mm thick cement plaster in cement morter 1:6, on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
Two coats of Distempering wall with distemper oil emulsion white or tinted over a coat of 1mm thick wall care putty, including preparation of new surface, complete all as specified and directed.
Rendering 15mm thick cement plaster in cement morter 1:4 with water proofing compound @ 0.2% by wt. of cement or as per manufacture instruction, on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
Supply only interral water proofing compound, complete all as specified and directed.
Two coats of cement paint over a coat of priming plastered and other surfaced with alkali resistant priming paint including preparation of new surfaces, complete all as specified and diected.
Two coats of cement paint including preparation of new surfaces, complete all as specified and diected.
Hardcore of gauge n exc. 63 mm,with broken stone and boulder, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surfaces, complete all as specified and directed.
Sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed.
100mm thick PCC 1:4:8 type D-2 (40mm graded aggregate) as in sub-base layer, complete all as specified and directed.
25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded stone aggregate) as in flooring, complete all as specified and directed.
40mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded stone aggregate) as in flooring even and smooth finish with using extra cement, complete all as specified and directed.
50mm thick Cement concrete type B-1, 1:2:4 (20 mm graded stone aggregate) as in flooring even and smooth finish with using extra cement, complete all as specified and directed.
Non-skid ceramic coloured tiles 7 to 8mm thick of size 400mm x 400mm in floors etc. set and jointed in neat cement slurry over and including 15mm thick screed bed of CM 1:6 and pointed in white/ coloured cement to match, complete all as specified and directed.
All as per item No 26 here in before but as in wall skirting including 10mm thick rendering of CM 1:4 and pointed in white/ coloured cement to match, complete all as specified and directed.
Glazed ceramic coloured tiles in vertical surface 350x250mm x 7mm/ 450x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick bedding layer of cement mortar 1:4, complete all as specified and directed.
20mm thick Granite (Jet black) of any type work (table rubbed and polished) in cooking plateform, widow sill and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade granite, complete all as specified and directed.
75mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in flooring, foot path, hard standing, plinth protection, bases of water tanks etc. including finishing surface even and smooth without using extra cement, complete all as specified and directed.
75mm thick Cement concrete type C-1, 1:3:6 (20mm graded stone aggregate) as in flooring, foot path, hard standing, plinth protection, bases of water tanks etc. including finishing surface even and fair without using extra cement, complete all as specified and directed.
Steel work in tubular trusses including special shaped washer ect. complete using ERW or indluding butt welded tubes conforming to I.S.1161-1998 grade St-240, complete all as specified and directed.
Two coats of synthetic enamel paints over a coats of red oxide primer including prepration of new steel surfaces of any description over 10 cm in width or girth not otherwise described, complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall or in door, fixed with self tapping screws, complete all as specified and directed.
4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) pre-primetered self embossed, textured designer board E-Board Classic to be fixed GI grid/section size 600mmx600mm with main runner 38x24x0.9mm thick, cross tee 28.6x24x0.9 mm and wall angle 19x19x0.9 mm duly suspended with 2mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size and finally applying two coats of oil bound distemper, complete all as specified and directed.
Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life, complete all as specified and directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet 12mm thick to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and directed.
75mm long Butt hinges, medium weight, cold rolled mild steel, complete all as specified and directed.
125mm aluminium anodised barrel tower bolts of extruded section and fixed, complete all as specified and directed.
125mm Aluminium handles, cast type anodised, complete all as specified and directed.
Anodised aluminium frame/ grill/ guard bar for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and directed.
Anodised aluminium, window and ventilator shutters, fixed type without sash bar, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc., complete all as specified and directed.
Sheet glass, of 4mm thick ordinary quality and glazing with oil putty in square in each pane, complete all as specified and directed.
Galvanised stainless steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and directed.
Sheet glass, of 4mm thick ordinary quality ground or obscured or frosted, on one side and glazing with oil putty in square in each pane, complete all as specified and directed.
Round Bars 6 to 8 mm dia and over, cut to length, bent to shape required, inculding cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (ennealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Second class hard wood plain, solid, straight chowkats and frames wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in hold fast blocks including necessary forms work, moulds etc, complete all as specified and directed.
30mm thick flush shutters solid core construction with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
100mm long Butt hinges, medium weight, cold rolled mild steel, complete all as specified and directed.
200mm aluminium anodised barrel tower bolts of extruded section and fixed, complete all as specified and directed.
300mm long aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed, complete all as specified and directed.
150mm Aluminium handles, cast type anodised, complete all as specified and directed.
Preparation of untreated new wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer, complete all as specified and directed.
Vitreous china wash basin, size 550 x 400mm white including brackets, and waste coupling & pipe of 32mm dia, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other, complete all as specified and directed.
Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), including plastic water closet seat, black or white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as specified and directed.
PVC valveless, syphonic action type, flushing cistern of 10 litres capacity, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern, complete all as specified and directed.
PVC connections 15mm size with PTMT nuts of length 600mm, complete all as specified and directed.
Brass cromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed.
Soap dish, any type of size approximate size 160x 60x90mm, fixed to plugs with chromium plated brass screws, complete all as specified and directed.
Grating doom 100mm dia with or without waste hole of PTMT. (Minimum weight 25gms), complete all as specified and directed.
5mm thick mirror of size 450mm x 600mm mounted on 6mm thick commercial ply wood backing and screwed with PVC channel alround, complete all as specified and directed.
15mm Bib taps, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
15mm pillar tap,cast copper alloy, with capstan head, chromium plated, fancy type screwed down high pressure,with or without lettered "Hot" or "Cold" with long screwed shank and fly-nuts, screwed for iron pipe, complete all as specified and directed.
Concealed type/Angle stop valve 15mm bore, fancy type chromium plated with long shank and cup (concealed type) screwed down, high pressure with crutch or butterfly handle,screwed both end for iron pipe or for unions, complete all as specified and directed.
Tubes 15mm bore, `medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
All as item no 67 here in before but 20mm bore, complete all as specified and directed.
PVC (SWR) pipes 110mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
PVC (SWR) pipes 110mm bore, single socketed, in any length with rubber ring joints, fixed to wall, complete all as specified and directed.
PVC (SWR) bends 110mm bore of any radius, complete all as specified and directed.
S&F PVC (SWR) 110mm bore vent cowl, complete all as specified and directed.
PVC (SWR) 'P' or 'S' trap 110mm bore, complete all as specified and directed.
PVC (SWR) pipes 150mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors or in walls, complete all as specified and directed.
Cement concrete 1:3:6 type C2 as in bed to 150mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in,complete all as specified and directed.
20mm gun metal, globe or gate valves with iron wheel head screwed both ends for iron pipe, complete all as specified and directed.
4 mm dia plain mild steel wire, galvanised class 3, in fencing including straining and fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc., complete all as specified and directed. (each line of wire to be measured)
Cement concerte in surface channels and drains type C-1 1:3:6 using 20mm graded aggregate including necessary shuttering, complete all as specified and directed.
Cement concerte in surface channels and drains type B-1 1:2:4 using 20mm graded aggregate including necessary shuttering, complete all as specified and directed.
Extra for forming fair finished surfaces of drain or channels, inner girth 30 cms, using extra cement including forms, moulds mitred/ stopped ends etc., complete all as specified and directed.
Extra for forming fair finished surfaces of drain or channels, inner girth 40 cms, using extra cement including forms, moulds mitred/ stopped ends etc., complete all as specified and directed.
Form work to sides of concrete foundations footings bases of columns and raft beams, sides and soffits of foundation and plinth beams and similar work vertical or to batter, complete all as specified and directed.
Reinforced cement concrete type B1-1:2:4 (20mm graded aggregate) as in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns etc, complete all as specified and directed.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and directed
Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165, complete all as specified and directed. (Brackets over 10 kg each to be measured under 'Structural Steel')
Mild steel screw bolts, diameter of neck in 16 to 20mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10cm and n exc 15cm long, complete all as specified and directed.
Design, Supply and fixing at site of the TRAY PANEL SCREW type system with aluminium composite panel of approved colour on exterior walls, columns, MS structure, ceiling, coping, slab projectons at all heights and elevation including necessary aluminium framework. The aluminium composite panel should 4 mm thick consist of 3mm thick thermoplastic core of anti toxidant LDPE sandwitched between 2 skins of 0.5mm thick aluminium alloy sheet making a total panel thickness of 4mm. The external surface shall be finshed with PVDF based coating on the top side and service coating on the reverse side shall be with a polymer paint, complete all as specified and directed. NOTE:- The system shall be designed to withstand a wind pressure of 190 kg/Sqm with necessary Alu. sub frames, cleats and shall be fixed to the masonry/ RC walls/ MS structure with necessary clamps, galvanized M.S brackets and anchor fasteners. All clamps and brackets shall be Hot dip galvanized minimum 80 microns thick and shall conform to IS: 4759-1996. Any other acessories such as fastening straps, nuts, bolts, rivets, washers, etc. other than anchor system shall be in Indian standard grade. all joints of ACP must be sealed with approved sealent of approved colour. sealant make DOW CORNING 789 weather sealant. Rate shall include to provide open cell polyethylene backer rods, weather sealant etc, including all materials and labour . Colour and design of ACP as approved by GE.
RCC design mix of M-25 using 20 mm graded stone aggregate as in foundation, including raft, footings, foundation beams; plinth beams; bases for coloumns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed.
RCC design mix of M-25 using 20 mm graded stone aggregate as in beams, cantilevers, bressumers, lintels beams over 1.5 m span, complete all as specified and directed.
RCC design mix of M-25 using 20 mm graded stone aggregate as in columns, pillars, piers, post and struts, complete all as specified and directed.
RCC design mix of M-25 using 20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roof, landings, balconies, canopies, deck slabs and in shelves and like, complete all as specified and directed.
RCC design mix of M-25 using 20 mm graded stone aggregate as in chajjas supported on walls, beams and columns in floor, roofs, landings, balconies, canopies and like, complete all as specified and directed.
Formwork to sides of pillars posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete, square, rectangular or polygonal, complete all as specified and directed.
Form work for rough finished flat surfaces of concrete, to chullah hoods, chajjas, troughs and similar items including edges, complete all as specified and directed.
Mild steel TMT bars 6 to 8 mm dia and over, quality conforming to Grade Fe-500 or 550 cut to length , bent to shape required including cranking , bending spirally for hooping for columns,, hooking ends, binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Rendering 15 mm thick as in cement mortar 1:4 on walls of brick or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed.
Rendering 15 mm thick as in cement mortar 1:6 on walls of brick or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed.
Rendering 10 mm thick as in cement mortar 1:4 on ceiling surfaces concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed.
Preparation of newly plastered or unplastered surfaces of walls and applying three coats of white/lime wash, complete all as specified and directed.
Preparation of newly plastered or unplastered surfaces of ceiling etc., and applying three coats of white/lime wash, complete all as specified and directed.
Mild steel in frame work as in doors or gates of angle or other serction with gussest plates, rails, braces etc, complete drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges, and hanging, also fastening and fixing complete confirming to (Fe-290-W Gde E-165), complete all as specified and directed.
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
20 mm thick rendering in two layers as (15 mm thick and 5 mm thick) in CM 1:4, top layer of 5 mm thick will be mixed with liquid water proofing admixture as per manufacturer's instructions on fair faces of brick wall or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed. ( WPC shall be measured and paid seperately)
Water proofing treatment on horizonal or vertical surfaces by applying oil bound primer @ 0.20 Kg/Sqm and providing 4 mm thick APP modified water proofing membrane weighing not less than 4 Kg/Sqm reinforced with non-woven polyester matt weighing not less that 160 gm/Sqm including minimum 10 cm side lap and15 cm end lap torch sealed and bonded and applying a coat of blown grade hot bitumen 90/15 over and below the membrane @ 120 Kg/Sqm in drying over the membrane finished with solar reflective bituminous aluminium paint / primer @ 0.20 Kg/Sqm over RCC roof slab/parapet after cleaning the surfaces by removing dust, dirt etc as per manufacturers instructions, complete all as specified and directed.
Plastic dividing strip, 22 mm width, 1.5 mm thick, inserted in position, conform to design, complete all as specified and directed.
Use and waste of formwork to side and soffits of floor suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (Horizontal or sloping), Rough finished surfaces of concrete, Flat etc, complete all as specified and directed.
Cement concrete 1:2:4 type B0 using 12.5 graded aggregates 40 mm thick for DPC including necessary form work etc, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light fan socket or power) complete including fittings such as switches, ceiling rose, pendants, regulators, sockets complete as directed and removing retrieved materials and making good the disturbed surface, complete all as specified and directed
Taking down existing light fittings of any description from wall/ ceiling including keeping in safe custody by making good the disturbed surfaces of walls, complete all as specified and directed.
Point wiring complete with 1100volts grade, single core, PVC insulated FRLS cable multi-stranded copper conductor of size 1.5 sqmm nominal area, drawn through and including rigid, PVC conduit of suitable size, with all necessary fittings and accessories fixed on walls/ ceiling with one run neutral and one run of single core cable of same description above but green colour in continous earthing wire connected to common earth dolly including PVC junction / mounting boxes on / in the wall / ceiling for piano switches/ switch socket combination/ fan regulators etc and GI junction box duly covered with 3mm thick hylam sheet for One light/ fan point controlled by one single pole 5 Amps switch, complete all as specified and directed.
All as per Srl item No 110 here in before but for One switch socket out let point 5 amps on independent board, complete all as specified and directed.
Allas per Srl item No 110 here in before but for One switch socket out let point 5 amps on the same board with other switches, complete all as specified and directed.
All as per item No 110 here in before but for PVC insulated FRLS copper conductor of size 4.0 sqmm for switch socket multipurpose 15 Amps including provision of 2.5 Sq mm PVC insulated FRLS copper conductor cable as earth continuity conductor on independent board
Switch piano flush button single pole one way 5 Amps, complete all as specified and directed.
Switch socket combination outlet 5 pin multipurpose 5 Amps, flush type, complete all as specified and directed.
Socket outlet 5 pin multipurpose 5 Amps flush type, complete all as specified and directed.
Switch socket combination outlet 6 pin 5 & 15 Amps multipurpose flush type, universal pattern 230 volts, complete all as specified and directed.
Ceiling fan 1200mm sweep AC single phase 230/ 240 V BEE certified of metal body and blades of 5 star rated white, including connecting and testing etc., complete all as specified and directed.
Ceiling rose surface bakelite three terminal of size 50x 24 mm,240 Volts AC, complete all as specified and directed.
LED flood light fitting of 35W with high pressure die cast housing and IP65 Protection, complete all as specified and directed . Cat No : BVP120 LED 35 CW FG S1 PSU GR of Philips or equivalent make
LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts , 2500 Lumens, efficiency > 110, CCT 6500k , CRI > 80 , Wall / surface mounted , IP 20 aluminium etrusion housing complete with including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting, complete all as specified and directed.
High efficient 45 watt LED Security light fitting with pressure die cast aluminium housing, IP66, Lumen output 100 lu/w system efficiency 100, colout temp 5700 k, CRI 70, including provision of 40 mm dia GI light grade pipe 1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed, complete all as specified and directed.
Steel sheet enclosure double door type for MCB DB SPN 4 way, 240 volts AC factory made, suitable for housing MCB SPN and SP along with 200 Amps copper bus bar, complete all as specified and directed.
Steel sheet enclosure double door type for MCB DB SPN 8 way, 240 volts AC factory made, suitable for housing MCB SPN and SP along with 200 Amps copper bus bar, complete all as specified and directed.
MCB SP of 06 to 32A, 10KA rupturing capacity, complete all as specified and directed. Cat : 810054-59 of Indoasian or equivalent make
MCB SPN 40 Amps, 240 Volts with breaking capacity of 10 KA, complete all as specified and directed.
Sub main wiring with Two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 4.0 sqmm in and including non-metallic rigid PVC conduits and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 2.5sqmm PVC insulated unsheathed copper earth continuity conductor including taking down of old unserviceable sub main wiring in any position and any type, complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC conduit and two run of copper conductor together taken as one length for measuring unit length.
Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground ( earth pit not less than 2.25mtrs deep below ground level) with top edge of the plate not less than 1.5mtrs below normal ground level, including provision of galvanised iron earth strip 32x6mm as earth lead connected by means of bolts, nuts, check nuts and washers of galvanised iron, provision of 40mm dia GI pipe medium grade for watering arrangement and PCC 1:3:6 type C1 chamber, MS Funnel, wire gauge, 50mm thick RCC 1:2:4 type B1 for earth pit cover with 6Nos x 8mm dia high strength deformed steel TMT bars on both ways, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance not exceeding 50m, provision of charcoal and salt in alternate complete all as shown in electrical place No 3 of schedule part I 2009 including testing on completion, complete all as specified and directed. Note : Cost of GI earth lead and GI protection pipe up to 7.5m length shall be deemed to be included in the rate quoted for this item.
Switch socket combination outlet 5pin multi purpose 5 Amps flush type, complete all as specified and directed.
10W High efficient LED Security light fitting with pressure die cast Aluminum housing, IP66, Lumen output 100 lu/w system efficiency 100, colout temp 5700 k ,CRI 70 , including provision of 40MM dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall, complete all as specified and directed.
Exhaust fans of size 300mm sweep, AC single phase 230/ 240 V of metallic body with louver and other accessories, complete all as specified and directed. Make : Havells, Ventil Air - DX White
Exhaust fans of size 250mm sweep, AC single phase 230/ 240 V of metallic body with louver and other accessories, complete all as specified and directed. Make : Havells, Ventil Air - DX White
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 110mm dia suitable for 0.4mpa working pressure, complete all as specified and directed.
XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (Heavy duty) with aluminium conductor 1100 Volt grade of cross sectional area 10 Sqmm 2 core including jointing, testing & commissioning in pipes/ducts/trenches / under floor/under road cables, complete all as specified and directed.
Unreinforced precast concrete cable cover as in 1:1½:3, type A-1, class LV, Type I, flat, of size 250mm X 150mm X 40mm laid dry over power cable for protection, complete all as specified and directed.
Sand cushioning with fine sand as specified in clause 14.5 of SSR Part-I to under ground cable in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed.
GI Tubes 'light grade' galvanised 50 mm dia with all fittings in trenches for passing of cables, complete all as specified and directed.
Dismantling and takingn up GI tube 40 mm dia and relaying for connecting/ extending with new pipe line including threading and jointing, complete all as specified and directed.
Cutting GI tubing 40mm dia threading and inserting GI tee joint and reducing to required size as directed for providing branch connection, complete all as specified and directed.
GI tubing 25 mm dia medium grade laid on floor/ roof/ wall including fitting and fixtures and anchoring, complete all as specified and directed.
Gun metal gate valve 25mm dia with iron wheel head screwed both ends for GI pipe and fixed, complete all as specified and directed.
Supply and fix in position on roof ,500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted, 3 layer PVC tank complete all as specified and as directed.
PTMT ball valve, high pressure, with epoxy coated aluminium rod and high density plastic ball screwed for 15mm bore GI tubes, fixed in repairs, all as specified and as directed.
GM Construction Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .