Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC | ₹35.2 L Quoted ₹36.0 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹37.5 L+₹1.5 L (4.08%)Rejected-Finance | ₹37.5 L+₹1.5 L (4.08%) | L2 | Rejected-Finance being L2 |
| 3 | L3₹37.6 L+₹1.6 L (4.47%)Rejected-Finance | ₹37.6 L+₹1.6 L (4.47%) | L3 | Rejected-Finance being L3 |
| 4 | L4₹38.2 L+₹2.2 L (6.06%)Rejected-Finance H NO 920 SEC 16 17 HISAR HARYANA 125005 | HISAR | HISAR | HARYANA | 125005 | ₹38.2 L+₹2.2 L (6.06%) | L4 | Rejected-Finance being L4 |
| 5 | L5₹38.8 L+₹2.8 L (7.67%)Rejected-Finance HOUSE NO 44 MASTER COLONY SATROD KHAS HISAR HARYANA 125044 | HISAR | HISAR | HARYANA | 125044 | ₹38.8 L+₹2.8 L (7.67%) | L5 | Rejected-Finance being L5 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
7 Oct 2021, 6:00 pmClosed
GE WEST HISAR
GE WEST HISAR, HISAR MIL STN, HISAR - 125006
SPECIAL REPAIR TO MES INSTALLATION AT WATER FILTRATION PLANT AND PROVN OF SECURITY FENCING ALONGTHE REAR SIDE BOUNDARY AT HISAR MIL STN UNDER GE (WEST) HISAR
2021_MES_471200_1
GE(W)HSR-18/2021-22
Open Tender
Civil Works
Item Rate
180 days
HISAR MILITARY STATION
please refer tender documents
9 documents required · 9 mandatory
₹500
Yes
GE WEST HISAR
₹87,000
Yes
29 Oct 2021
27 Aug 2021
9 Oct 2021
27 Aug 2021
7 Oct 2021
24 Sept 2021
Amount
Taking down cement plaster incl racking out joints, hacking for key & scrubbing down with water etc including removing rubbish complete all as specified and directed.
Dismantling of cast in situ terrazo/ tiles any thickness on wall incl racking out joints, hacking for key & scrubbing down with water etc including removing rubbish complete all as specified and directed.
Demolition of reinforded cement concrete of any description and in any position not otherwise specifically provided for chajjas, beams, roof projection, parapet /railing, Columns taken for pressure grouting including removing rubbish complete all as specified and directed.
Demolition of cement concrete as in ground floors and pavings not exceeding 15 cm thick below or above ground level (unreinforced) incluiding removing rubbish complete all as specified and directed.
M&L for 10mm thick rendering in CM 1:6 over brick / concrete wall surfaces finished even & fair without using extra cement on wall surfaces complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on brick / concrete wall surface finished even and fair without using extra cement complete all as specified and directed.
M&L for 10mm thick rendering in CM 1:3 over brick / concrete ceiling surfaces finished even & fair w/o using extra cement surfaces complete all as specified and directed.
M&L for Rough cast plaster as specified .(Rendering coat not less than 10mm thick in C:M 1:3 , while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg size 6 to 12mm mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even) on external wall upto cill height complete all as specified and directed.
M&L for non-skid tiles joint free ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for digital printed coloured designer glazed ceramic tiles in glossy / dull finish of size 300x450x7mm / 250x350x7mm thick as in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for 20 to 22mm thick, machine cut Kota stone slab of minimum size of 0.60m x 0.60m as in flooring laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and over including 15mm thick screed bed in cement mortar 1:6complete all as specified and directed.
M&L for 20 to 22mm thick, machine cut Kota stone slab of minimum size of 0.60m x 0.60m as in flooring , cooking platform, steps risers etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and over including 15mm thick screed bed in cement mortar 1:6 and for star case treads and window cill etc Kota stone be laid in one piece upto 1.5M length complete all as specified and directed.
Rounding to edges of stone slabs (Kota / Granite) one edges such as in steps, cooking platform and other similar situations complete all as specified and directed.
M&L for treatment of floor slab and walls of water walls comprising of the following specifications complete all as specified and directed :-
(i) Cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. Provision of 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout.
(ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with and including integral water proofing compound Sika Plastocreat plus or equivalent make in Fosroc / Thermax as approved by GE @ 0.2% by wt of cement consumed including filling it with water to check dampness and seepage and where dampness / seepage is noticed, nozzles shall be fixed and grouting carried out.
(iii)All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy puty Sikagard 694 F (I) or equivalent make in Fosroc / Thermax as approve by GE.
(iv) After drying putty, wash the slab and sides of sunken portion with water andmake it clear and clean.
(v) Applying two coats of polymer modified cementious water proof coating with Sika Topseal 107 or equivalent make in Fosroc / Thermax as approved by GE in two coats @ 3kg/sqm to sandwiched with glass fibre reinforcement : Sika® Fab-1 or equivalent make in Forsro / Thermax as approved by GE over base coat as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion.
(vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound SIKA plastocreat Plus or equivalent make in Fosroc / Thermax as approve by GE @ 0.2% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout.( WPC shall be measured & paid separately)
(vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint (Black Japan shall be paid separetely).
Supply only intergal liquid water proofing compound complete all as specified and directed.
S&F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts wind ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 (Gde E-165) complete all as specified and directed.
S&F in repair PVC (SWR) floor trap 75mm bore with grating incl jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed. .
Taking down shutter of any description area exc 1.5 sqm but not exc 2sqm each including removing from site complete all as specified and directed.
Taking down chowkats or frame with shutter, without taking off shutter from the frames area exc 1.5 sqm but not exc 4sqm each including removing from site complete all as specified and directed.
S&F pressed steel frames prepainted 125 x 60mm for doors with one or more rebates made out of 1.25mm thick PBI sheet including necessary lugs, hinges, lock strike plate, etc., complete all as specified and directed.
S&F pressed steel frames prepainted 105 x 60mm for doors with one or more rebates made out of 1.25mm thick PBI sheet including necessary lugs, hinges, lock strike plate, etc., complete all as specified and directed.
M&L for PCC 1:3:6 type C-0 (using 12.5mm Graded Stone Aggregate) as in filling of Chowkhats complete all as specified and directed.
S&F factory made Steel windows, ISI marked, (Box Type) with side hung shutters including mild steel butt hinges, tower bolts, handles etc complete with glazing bars dovetailed or welded including one shop coat of Zinc chrome primer including taking down old existing window and making good disturbed surfaces of walls,complete all as specified and directed. Notes:- (i) The rate quoted by the contractor are deemed to be included for one shop coat of red oxide zinc chrome primer on steel windows. Nothing shall extra paid on this account. (ii) Details of box type window shall be given on HQ CEJZ drawing No TD/2013/01 sheet 1/3, 2/3, 3/3. (iii) Glass pane/wire gauze shall be measured and paid separately.
S&F factory made Steel windows, ISI marked, (Box Type) with side hung shutters including mild steel butt hinges, tower bolts, handles etc complete without glazing bars dovetailed or welded including one shop coat of Zinc chrome primer including taking down old existing window and making good disturbed surfaces of walls, complete all as specified and directed. Notes:- (i) The rate quoted by the contractor are deemed to be included for one shop coat of red oxide zinc chrome primer on steel windows. Nothing shall extra paid on this account. (ii) Details of box type window shall be given on HQ CEJZ drawing No TD/2013/01 sheet 1/3, 2/3, 3/3. (iii) Glass pane/wire gauze shall be measured and paid separately.
M&L for mild steel in framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; ladders; railings and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc 0.50 sqm each complete all as specified and directed.
S&F in reepair 3mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc 0.50 sqm each complete all as specified and directed.
S&F 35mm thick factory made plain framed, paneled shutter made of 2nd class HW (Bonsum/Hollock) of 35 mm thick(two panels)with lock rail and panel of 12 mm veneered particle board with commercial veneering on both faces. The size of rail and styles as per IS: 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 35mm thick glazed and skelton shutters open rebated and prepared to receive gauze etc (without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred breds for securing glass etc sizes of members of shutters as specified in SSR Pt-I Sec 8 Clause 8.20(a) in 2nd class hard wood complete all as specified and directed.
S&F Aluminium anodised barrel tower bolt of extruded section 150mm long complete all as specified and directed
S&F in repair Aluminium anodised barrel tower bolt of extruded section 150mm long complete all as specified and directed
S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F in repair 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F 125 mm extruded aluminium alloy handles ,fabricated type complete all as specified and directed
S&F in repair 125 mm extruded aluminium alloy handles ,fabricated type complete all as specified and directed
S&F in repair mild steel handles for window duly bolted complete all as specified and directed
S&F Galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F in repair Galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of OBD of any tint over one coat of chalk whitening complete all as specified and directed.
M&L for complete removing existing treatment and preparation of plastered surface of wall and applying two coats of OBD of any tint over one coat of chalk whitening complete all as specified and directed.
M&L for preparation newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation old decorated plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
M&L for preparation of new wood or wooden based material surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint of any tint over one coat of pink primer, complete all as specified and directed.
M&L for preparation of old painted wood or wooden based material surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint of any tint complete all as specified and directed.
M&L for preparation of new steel or iron surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint of any tint over one coat of red oxide primer, complete all as specified and directed.
M&L for preparation of old steel or iron surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint of any tint over existing coat of primer, complete all as specified and directed.
M&L for preparation of old painted steel or iron surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint of any tint complete all as specified and directed.
M&L for preparation of old surface of walls and applying two coats of exterior weather proof paint white or any tint over and including one coat of exterior wall care putty min 1mm thick incl complete removal of existing treatment complete all as specified directed.
M&L for preparation of newly plastered surface of walls and applying two coats of exterior weather proof paint white or any tint over a coat of primer and one coat of wall care putty complete all as specified directed.
M&L for preparation of newly plastered surface of walls and applying two coats of exterior weather proof paint white or any tint over a coat of primer complete all as specified directed.
M&L for 50mm thick, cement concrete 1:3:6 type C1 using 20mm graded crushed stone aggregate as in plinth protection, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified and directed. .
M&L for precast cement concrete 1:2:4 type B-1 using 20 mm graded stone agg in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles complete all as specified and directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors dia of pipe 75mm complete all as specified and directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors dia of pipe 110mm complete all as specified and directed.
M&L for brick work with fly ash Bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, arches pillars etc and removing rubbish complete all as specified and directed.
Demolition Mud in roofs, any thickness,including plastering and leeping (whether full thickness removed or only a part thereof) and removing rubbish complete all as specified and directed.
Demolitin of Brick tiles or terracing tiles, single layer on roofs and removing rubbish complete all as specified and directed.
M&L for cement concrete 1:2:4 mix type B-O (12.5 mm graded stone aggregate) in padding finishing surface of concrete topping even and fair (without using extra cement) all as specified of average thickness 50 mm in slope 1:40 over roof complete all as specified and directed.
M&L for applying roof treatment on top of roof with APP based polymeric membrane (not less than 3mm thick , weight not less than 3.5Kg per Sqm, reinforced with polyster non-woven fabric ( weigthing not less than 150 gm/ Sqm ) laid by torch application method with side overlap 75mm and on end 100mm as per manufacture's instructions over a coat of hot paving bitumen of grade 30/40 conforming to IS 73 @ 1.2 Kg/ Sqm over a coat of bituminous primer conforming to IS -1984 @ 0.40 Kg /Sqm and applying two coats of aluminium paint over APP membrane over and incl 15mm thick plaster in cm 1:4 using liquid WPC as per manufacture instruction over RCC roof complete all as specified and directed
S&F in repair 300mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F in repair floor door stopper of aluminium alloy body size 75 mm with two rubber shoes complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire 0.9 mm dia. complete all as specified and directed.
All as per item No 63 above but for 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders 6 to 8mm dia.
M&L for providing precast cement concrete type B-I 1:2:4 using 20mm graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain face set in cement mortar 1:4 complete all as specified and directed.
M&L for 40mm thick PCC in cement concrete type B-I 1:2:4 using 20mm graded crushed stone aggregate in flooring finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for weld-mesh of size 75x75x3mm to be wrapped on the exposed surface of rib of beam & on the slab bottom and tack welding to the exposed reinforcement at close intervals and gunite with cement mortar 1:3 mixed with admixture SIKA Plasto creat plus or equivalent make in Fosroc / Thermax as approved by GE around rib of beam or roof slab of thickness n.exc 40mm to be applied under an operating pressure. the gunited surface to be cured properly for a min of 7 days all in complete as per the technical specifications and manufacturer's instructions complete all as specified and directed.
Supply and apply of rust remover cum passivator to remove rust from existing reinforcement by using Product : Rustoff-100 of Sika or equivalent make in Fosroc / Thermax as approved by GE, with density : 1.01 Kg/ltr at 30°C and consumption : 0.2 kg/Sqm/coat complete all as specified and directed. Note : The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar
Supply and apply cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats and product requirements: carbonation resistance : 2 mm of SikaTop Armatec®-108 of Sika or equivalent make in Fosroc / Thermax as approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N/Sqmm according to ASTM C 882-78 complete all as specified and directed. Note : The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar.
M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete substrate in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions complete all as specified and directed.
M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness of upto 10mm to the prepared concrete substrate in soffit of slabs, beam, columns, parapets, fins and facias at any height including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructionscomplete all as specified and directed.
M&L for 75mm thick cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate ) as in sub base complete all as specified and directed.
M&L for factory made rubber moulded vibratory precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade fixed with grey cement and pigment laid over and incl 25mm thick sand cushion complete all as specified and directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) embedded in concrete,brick work,masonary etc. any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed.
Dismantling of any type fencing, chain link or barbed wire fencing & wire mesh etc. complete all as specified and directed
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in soft/ loose soil including removing surplus soil complete all as specified and directed.
M&L for plain cement concrete type C-2 1:3:6 (using 40 mm graded crushed stone aggregate) as in foundations,filling and mass concrete complete all as specified and directed.
S&F mild steel work in Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Fixing only GI chain link fencing of any dia, any mesh, size and type to any type of standards, rails, straining bolts, etc.incl provission of binding wire complete all as specified and directed.
Supply only chain link MS galvanisd fencing, any size or type complete all as specified and directed.
S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and fixed to fencing posts conforming to Fe 290 (Gde - E-165) complete all as specified and directed.
M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exc 5cm long and 5 to 10 mm dia. complete all as specified and directed.
M&L for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed fixed in repair with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed fixed in repair (each line wire to be measured) complete all as specified and directed.
Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed.
M&L for point wiring for one light / bell / Ceiling fan/Exhaust Fan point controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FRLS drawn through rigid PVC coduit 20 mm dia medium grade and conduit accessories concealed type in walls/ceilings and including change of steel terminal sunken boxes and 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for one light point/fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FRLS connected to common earth dolly complete complete all as specified and directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).
All as per item No. 86 above but for one 5 pin 5 Amp socket outlet on independent board controlled by one number one way switch on independent board complete all as specified and directed.
All as per item No. 86 above but for one 5 Pin 5 Amp socket outlet on the same board controlled by one number one way switch on same board.
All as per srl item No. 86 above but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent board including provn of 2.50 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed.
S&F flush type socket outlet multipurpose 3&6 Pin, 15 Amp 230 volts AC complete all as specified and directed.
S&F flush type socket outlet multipurpose 2&3 Pin, 5/6 Amp 230 volts AC complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 5/6 Amp, 230/240 Volts grade complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 15 Amp, 230/240 Volts grade complete all as specified and directed.
S&F Lamp holder of PVC / Polycarbonate type surface with 9 watt LED bulb complete all as specified and directed.
S&F ceiling rose surface bakelite, 3 terminals with back plate etc complete all as specified and directed.
S&F in replacement LED tube light fitting 18W metallic frame /batten, Retro, Box type surface and wall mounted, including LED tube light rod , high efficiency including making connection, complete all as specified and directed.
S&F in replacement LED flood light fitting of capacity 60 watt, external with lence, 240 volt, pressure die cast aluminium housing frame, heat resistant toughtened clear glass with frame with accessories , IP 66 protection prewired and making connection complete all as specified and directed.
M&L for GI pipe light grade 40mm suitable for bracket of street light fitting 1.2 mtrs long including MS flat iron clamp 25x3mm thick with nut bolt and washers for fixing in pole and wall complete all as specified and directed.
S&F Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed.
S&F MCB SP, 6 to 32 Amps 240 Volts , type 'B' curve, 10 KA, fixing in DB complete all as specified and directed.
S&F MCB SPN, 32 to 40 Amps 240 Volts , type 'B' curve, 10 KA, for fixing in DB complete all as specified and directed.
S&F in replacement Sheet metal enclosures for DBs when MCBs to be used Single pole and neutral (SPN 240 Volts) with 200 Amps rated busbar 8 way double door complete all as specified and directed
S&F in replacement Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 4 sqmm, 1100 votls grade drawing through and including PVC casing and caping with acessories and including PVC insulated 4 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed. (Note:- Two lengths of 4 Sqmm cable, one length of 4 Sqmm cable and one length of PVC casing and caping will be measured as one length).
Supplying laying, jointing, testing and commissioning of LT UG XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade of size 10 sqmm 2 core including taking down old U/S cable complete all as specified and directed. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc . Eexcavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid for separtely) complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.
M/S RAJINDER SINGH
Shiva Constructin Co.
SHRI HARI BUILDERS
m/s AR Construction co
P.K. ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .