| 1.00 | Organizing visit of skilled technician/ Engineer of OEM (which is Blue Star) of central AC Plant of capacity 2 x 56 TR (Chilled water and strip heater type) air cooled type installed at Manekshaw Auditorium for the followings :-
(i) Depute a skilled technician/ Engineer for two working days except Sunday/ Holidays.
(ii) Checking, Testing and providing consultancy for necessary repair to be carried out and providing necessary testing report of each Central type AC plant unit.
(iii) Providing consultancy for repairing maintenance schedule for the smooth working of all equipments.
(iv) The entire equipments will be serviced in presence of skilled technician. | 3 | Per Visit | 20,000 ₹60,000 | 6,000 ₹18,000 Lowest |
| 1.01Note: (a) Necessary repairs and parts to be replaced will be paid separately under respective items. (b) Contractor will provide the uniforms for technicians. (c) Contractor will provide necessary documents from the OEM in respect of visit to be carried out as required by engineer-in-charge. (d) First such inspection and servicing shall be carried out within 21 days from the date of commencement of work given in work order No 01. (e) Minor spares such as nuts, bolts, washers, aluminum lugs, grease or any minor spare part required for satisfactory operation of AC plant, other than mentioned in this CA here-in-after are deemed to be included in unit rate quoted by the contractor. (f) If Contractor fails to repair/ replace any faulty items within 24 Hours after entry of fault in log sheet, a panel recovery of Rs. 1000/- per day after 24 hours shall be recovered from next RAR from the contractor without any formal communication besides the recovery of penalty. | |||||
| 1.02The details of plant equipments are as follows:- (i) Multi stage reciprocating compressor: Model. XACYS2060R2. Make: Blue Star (Capacity 18 TR each) (Three Nos in each set) -02 Set (ii) Electrical control panel (LT) 440 volts, 680 Amps - 02 Nos. (iii) Condenser and chiller of shell and tube type - 02 Nos (iv) AHU blower motor of capacity 11 KW - 02 Nos. (v) Chilled water pumping set of 7.5 HP, 3 phase, 440 volts - 03 Nos. (vi) Paharpur induced draft cooling tower, 204 Ton, with 15 HP - 01 No wheather proof, gear driven electrical motor. (vii) All other connected items of the plants/ equipments/ machines mentioned in respects of sub paras (i) to (vi) above. Contd.. | |||||
| 1.03Contd.. (viii) Air handling unit, blower, evaporating coil and other sections of humidification arrangements, electrical panels etc and all other connected items - 06 Nos. (ix) Water softening unit with monoblock pump 2 HP- 01 No. Notes :- Following checks and duties shall also be carried out under this item:- (a) Checking the proper functioning of all Air Conditioning plants 2X 56 TR and AHU's. Make: Blue Star. | |||||
| 2.00 | Supply and charging of Gas R-407C suitable for 2 x 56 TR chiller plant after detecting and rectification of any leakage in system by using CO2 gas and flushing the complete system with Nitrogen gas as required complete all as specified and directed by Engr-in-Charge.
Note :
(a) Gas to be brought by contractor at site from authorised dealer in company sealed cylinder.
(b) The unit rate inserted shall deemed to be included the cost of CO2 and Nitrogen gas to be used for leakage test and flushing and pressure test prior to charging the gas in plant as required. | 60 | Kilogram | 1,100 ₹66,000 Lowest | 1,100 ₹66,000 Lowest |
| 3.00 | M&L for servicing including petty repair to chiller pump 7.5 HP (5.5 KW) after disconnecting electric connections such as replacement of gland packing, bearing, seal, coupling, nut bolts washer, greasing etc as required for satisfactory operation for pump complete all as specified and as directed by Engineer-in-Charge. | 1 | Each Job | 4,000 ₹4,000 Lowest | 6,000 ₹6,000 |
| 4.00 | Disconnecting Electrical and pump connection from unserviceable Motor of capacity 7.5 HP (5.5 KW), 3 phase, 415 volt and transporting to workshop for rewinding the motor dismantling, cutting and removing the burnt windings from the motor, cleaning the core, removing all carbon by chemically and rewinding with existing size/gauge of super enameled/ copper wire and other approved insulating materials, heating, drying up, re-assembling, refxing and re-installation at site complete and testing on load complete all as specified and as directed.
Note: (i) Required T & P such as chain pulley block and transportation shall be contractor's responsibility and quoted rate shall be deemed to inculde the same.
(ii) After assembling, rewinded motor shall be checked for no load current and full load current all as directed.
(iii) Replacement of unserviceable parts will be measured and paid in respective items of schedule. | 1 | Each Job | 8,000 ₹8,000 | 3,000 ₹3,000 Lowest |
| 5.00 | Supply only of Ball bearing suitable for 7.5 HP (5.5 KW) motor complete all as specified and as directed by Engineer-in-Charge. | 1 | Each | 500 ₹500 Lowest | 900 ₹900 |
| 6.00 | Supply only of Motor terminal box of sizes for 7.5 HP (5.5 KW) motor complete all as specified and as directed by Engineer-in-Charge. | 1 | Each | 300 ₹300 Lowest | 1,200 ₹1,200 |
| 7.00 | Supply only of Shaft key of suitable size for 7.5 HP (5.5 KW) motor complete all as specified and as directed by Engineer-in-Charge. | 1 | Each | 100 ₹100 Lowest | 200 ₹200 |
Tender Value
₹9.8 L
EMD Value
₹19,500
Closing Date
8 Aug 2026, 6:00 pmClosed
CWE Chandimandir
HQ CWE Chandimandir, PIN-134107
CWE/CHM(U)-33/2026-27 PREVENTIVE MAINTENANCE OF AC PLANT IN MANEKSHAW AUDITORIUM UNDER AGE E/M II OF GE(U) CHANDIMANDIR
2026_MES_776179_1
CWE/CHM(U)-33/2026-27
Open Tender
Electrical and Maintenance Works
Item Wise
330 days
GE (U) Chandimandir
Class E, Cate c(i)
8 documents required · 8 mandatory
₹500
GE (U) Chandimandir
₹19,500
14 Sept 2026
3 Jul 2026
11 Aug 2026
3 Jul 2026
8 Aug 2026
20 Jul 2026
3 Jul 2026 - 10 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Organizing visit of skilled technician/ Engineer of OEM (which is Blue Star) of central AC Plant of capacity 2 x 56 TR (Chilled water and strip heater type) air cooled type installed at Manekshaw Auditorium for the followings :-
(i) Depute a skilled technician/ Engineer for two working days except Sunday/ Holidays.
(ii) Checking, Testing and providing consultancy for necessary repair to be carried out and providing necessary testing report of each Central type AC plant unit.
(iii) Providing consultancy for repairing maintenance schedule for the smooth working of all equipments.
(iv) The entire equipments will be serviced in presence of skilled technician. | 1 | Per Visit | 1.25 | ₹1.25 |
| 1.02 | The details of plant equipments are as follows:-
(i) Multi stage reciprocating compressor: Model. XACYS2060R2. Make: Blue Star (Capacity 18 TR each) (Three Nos in each set) -02 Set
(ii) Electrical control panel (LT) 440 volts, 680 Amps - 02 Nos.
(iii) Condenser and chiller of shell and tube type - 02 Nos
(iv) AHU blower motor of capacity 11 KW - 02 Nos.
(v) Chilled water pumping set of 7.5 HP, 3 phase, 440 volts - 03 Nos. (vi) Paharpur induced draft cooling tower, 204 Ton, with 15 HP - 01 No wheather proof, gear driven electrical motor.
(vii) All other connected items of the plants/ equipments/ machines mentioned in respects of sub paras (i) to (vi) above.
Contd.. | - | - | - | - |
| 1.03 | Contd..
(viii) Air handling unit, blower, evaporating coil and other sections of humidification arrangements, electrical panels etc and all other connected items - 06 Nos.
(ix) Water softening unit with monoblock pump 2 HP- 01 No.
Notes :- Following checks and duties shall also be carried out under this item:- (a) Checking the proper functioning of all Air Conditioning plants 2X 56 TR and AHU's.
Make: Blue Star. | - | - | - | - |
| 2 | Supply and charging of Gas R-407C suitable for 2 x 56 TR chiller plant after detecting and rectification of any leakage in system by using CO2 gas and flushing the complete system with Nitrogen gas as required complete all as specified and directed by Engr-in-Charge.
Note :
(a) Gas to be brought by contractor at site from authorised dealer in company sealed cylinder.
(b) The unit rate inserted shall deemed to be included the cost of CO2 and Nitrogen gas to be used for leakage test and flushing and pressure test prior to charging the gas in plant as required. | 60 | Kilogram | - | - |
| 3 | M&L for servicing including petty repair to chiller pump 7.5 HP (5.5 KW) after disconnecting electric connections such as replacement of gland packing, bearing, seal, coupling, nut bolts washer, greasing etc as required for satisfactory operation for pump complete all as specified and as directed by Engineer-in-Charge. | 1 | Each Job | 100 | ₹100 |
| 4 | Disconnecting Electrical and pump connection from unserviceable Motor of capacity 7.5 HP (5.5 KW), 3 phase, 415 volt and transporting to workshop for rewinding the motor dismantling, cutting and removing the burnt windings from the motor, cleaning the core, removing all carbon by chemically and rewinding with existing size/gauge of super enameled/ copper wire and other approved insulating materials, heating, drying up, re-assembling, refxing and re-installation at site complete and testing on load complete all as specified and as directed.
Note: (i) Required T & P such as chain pulley block and transportation shall be contractor's responsibility and quoted rate shall be deemed to inculde the same.
(ii) After assembling, rewinded motor shall be checked for no load current and full load current all as directed.
(iii) Replacement of unserviceable parts will be measured and paid in respective items of schedule. | 1 | Each Job | 53 | ₹53 |
| 5 | Supply only of Ball bearing suitable for 7.5 HP (5.5 KW) motor complete all as specified and as directed by Engineer-in-Charge. | 1 | Each | 10 | ₹10 |
| 6 | Supply only of Motor terminal box of sizes for 7.5 HP (5.5 KW) motor complete all as specified and as directed by Engineer-in-Charge. | 1 | Each | 11 | ₹11 |
| 7 | Supply only of Shaft key of suitable size for 7.5 HP (5.5 KW) motor complete all as specified and as directed by Engineer-in-Charge. | 1 | Each | 1.25 | ₹1.25 |
| 8 | Material and labour for descaling of condenser unit of 56 TR Each (Chilled water and strip heater type) air cooled type plant including accessories like pipe line and condenser tubes by using wire brush and cleaning thoroughly by using cleaning prescribed chemical (as per IS) to make system serviceable complete all as specified and as directed by Engineer-in-Charge. | 2 | Each Job | 100 | ₹200 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.10 MB
Tenderdocuments33.pdf
Tender Documents • 0.59 MB
Additional33.pdf
Additional Documents • 0.46 MB
BOQ_869177.xls
BOQ • 0.49 MB
Amdt.pdf
PDF • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .