Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹29.7 L+₹1.1 L (4.01%)Rejected-AOC FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹30.6 L+₹2.0 L (6.96%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹31.4 L+₹2.8 L (9.77%)Rejected-AOC 601 6TH FLOOR MANGOOR VALLEY NEAR GURUDWARA MANGOOR HILLL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹31.4 L+₹2.8 L (9.90%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹36.9 L
EMD Value
₹74,000
Closing Date
27 Sept 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER GOMANATAK
GARRISON ENGINEER GOMANTAK VASCO DA GAMA PIN 403802
Addition Alteration of Containering De-containering and preservation room for testing and Maintenance of Rampage Missile at NAD Goa and Provision of approach path behind Bldg No P-72 at INS Gomantak under GE Gomantak Vasco
2022_MES_550568_1
8466/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
VASCO DA GAMA
Refer tender documents
8 documents required · 8 mandatory
₹500
GE GOMANTAK
₹74,000
Yes
7 Oct 2022
7 Sept 2022
28 Sept 2022
7 Sept 2022
27 Sept 2022
21 Sept 2022
Amount
Demolition of brick work or stone/boulder masonry built in cement mortar, complete all as specified.
M&L for Pre-cast cement concrete type C1 (1:3;6) block masonry with solid blocks, exc. 10 cm in width and setting in mortar (1:4) complete all as specified and as directed.
Taking down cement plaster on brick work or stone walls including racking out joints ,hacking for key,scrubing down with water etc
M & L 15 mm thick rendering on fair faces of concrete in CM 1:6 finish the surface even & smooth without using extra cement complete all as specified and directed
M&L for preparation of new plastered surface & applying two coats of oil bound distemper (OBD) over a coat of white chalktening on wall complete all as specified and directed by Engineer-in-charge.
Material & Labour two coats of acrylic emulsion extenior paint (anti fungal painting-APEX or Equivalent) over a coat of acrylic amulsion primer including preparation of new concrete surface of any description all as specified and directed by Engr-in-Charge.
S & F Galvanised steel tubes, midium grade Bore of pipe in 200mm all as specified and directed.
Demolition of cement concrete in floor and pavinngs nexc 15 cm thickness (below ao above ground level all as specified and directed.
Demolition of stone slab or tiles of any description or thickness in floors or aprons etc (laid bedded and pointed in any mortar) complete all as specified and as directed
M&L for machine cut Kota stone slab of size 600mm x 600m x 18 to 20 mm thick as in flooring , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror finished complete over screed bed of 15mm thick in CM 1:6 all as directed .
M/L for 70mm thick as in sub base for floor Cement concrete type B-1, 1:2:4 (20mm graded aggregate)Finishing cement concrete surface even and smooth with out using extra cement.
M &L ANTI-STATIC / CONDUCTIVE EPOXY FLOOR for preparation of concrete floor surfaces of any description and any position by brooming down/wire brushing and finally cleaned with compressed air to make the surfaces dust free and Apply the mixed mix using roller in two coats at a time gap 6 -8 hrs and at total thickness of 175 - 200 micron. Poorly primed surface may lead to blistering, pin-holing and more importantly the conductive values may get affected. After application of first coat, place self- adhesive copper tape (25 mm width and 70 - 100 micron thick) at the periphery of the primed surface. Allow the primed surface to dry). complete all as specified and as directed.
Taking down broken old Aluminium doors of any size and any description.
S & F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and framed guard bars (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete as in grills, gates, iron doors etc, conforming to Fe-290. Gde-E-165.
S & F Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes
S & F Mild steel in flat, round or square bars, in available lengths
M&L for applying two coats of anti corresive paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome
M & L for applying two coats of Fire resestant paint Surfaces of any description wood, steel, iron, concrete, brick, stone, etc., exceeding 10cm in width or girth all as specified and as directed.
S&F Anodised aluminium snap grid frame work for false ceiling all as specified size of grid 605x605mm.
S&F hangers 6mm GI(Up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long complete all as specified for false ceiling all as specified .
Supply & Fixing 10 mm thick PVC insulation panels in ceiling board with EPS of net to 1mm printed PVC sheet suitably placed in false ceiling grid all as per specification and drawing
Dismantling floor,hearth or wall tiling including cement mortar bedding ( but not backing coat) removing serviceable tiles and rubbish off the premises
M&L 20mm thick screed bed or bedding layer of cemnt mortar 1:4 for laying floor finishes.
M&L Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm light shade, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match.
M&L Reinforced concrete pipes(600mm) , class NP3, laid and jointed complete with collars
Taking down carefully copper/aluminium point wiring any type (light, fan socket or power) complete (fittings such as switches, ceiling roses pendants, regulators, sockets etc to be measured separately) removing materials at site and making good disturbed surfaces of walls floors etc.
M&L for one light point controlled by one switch with cables 1.5 Sqmm copper cable FRLS multistranded unsheathed drawn through in concealed stove enamelled steel conduit on wall and 1.5 sqmm copper conductor cable for earth wire including making connection with common earth and earth dolly and making good disturbed surface of walls and floors to match with existing surfaces all as per specified and directed by Engr-in-Charge.
M&L for point wiring for 15 amp independant point with 4 Sqmm copper wire & 4 Sqmm copper wire as earth lead drawn through & including concealed stove enamelled steel conduit on wall of suitable size complete all as specified and directed by Engr-in-Charge.
Supply and fixing flame proof rotary type with termination box in LM6, Single pole 250 Volts, ON or OFF Element. Make : Sudhir/CG/Baliga
Supply and fixing Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25A, 250V, 2P+earth interlocked Switch, Socket & plug complete. Make : Sudhir/CG/Baliga/Shyam Switchgears
Supply and fixing Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 32A, 415V, 3P+neutral+earth interlocked Switch, Socket & plug complete. Make : Sudhir/CG/Baliga/Shyam Switchgears
Supply and fixing LED light fitting 2x20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. Make : Sudhir/CG/Baliga/Shyam Switchgears
Supply & Fixing submain wiring with 3 Runs (Phase, Neutral and Earth) of 4 Sqmm, PVC insulated, unsheathed, single core, multi stranded, 1100 volts, FRLS copper conductor cable drawn in and including concealed stove enamelled steel conduit on wall of suitable size with all accessories as required and connecting to existing main switch board/Distribution Board/Earth continuity and testing on completion all as directed by Engineer-in-Charge.
Supply & Fixing submain wiring with 5 Runs (Phase, Neutral and Earth) of 4 Sqmm, PVC insulated, unsheathed, single core, multi stranded, 1100 volts, FRLS copper conductor cable drawn in and including concealed stove enamelled steel conduit on wall of suitable size with all accessories as required and connecting to existing main switch board/Distribution Board/Earth continuity and testing on completion all as directed by Engineer-in-Charge.
Supply & Fixing submain wiring with 5 Runs (3 Phase, Neutral and Earth) of 10 Sqmm, PVC insulated, unsheathed, single core, multi stranded, 1100 volts, FRLS copper conductor cable drawn in and including concealed stove enamelled steel conduit on wall of suitable size with all accessories as required and connecting to existing main switch board/Distribution Board/Earth continuity and testing on completion all as directed by Engineer-in-Charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 6 to 32 Amps of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN 40 Amps of following poles and current carrying capacity in the DB complete with connection testing and commissioning.
Supply & fixing in repairs TPN 4 way double door with suitable size of busbar neutral/earth link connector including dismantling of old one complete all as specified and directed.
M&L in repair for existing damaged earthing near explosive area provn of electrogrip safe chemical earthing , electrode made of 17mm dia 250micron copper bonded rod, 3 mtr long with connecting strip head with SS fastener, inspection joint box and also connect copper strip with electrode rod and inspection joint box with nut, bolts and GI washers etc . The electrodes will be filled with highly conductive non-corrosive crystalline conductive mixture with connective arrangement for connection of strip/cable etc. The electrode will be installed along with conductive and low resistance powder tested to the resistivity of 0.2 ohms as per IEC 62561-7 read with ASTM G57-06, CI 3.4 connected to copper strip by means of nut bolts check nuts and washer of GI or steel including necessary drilling in earth upto 3 mtr in any type of soil for inserting electrode in any type of strata, HDPE earth pit cover of suitable size and earth pit cover with frame including chemical using for such type of earthing complete all as directed by Engr-in-Charge.
Supply and fixing Earth continuity conductor or main earthing lead of 16 sqmm PVC insulated copper conductor drawn in through concealed steel conduit/pipe and connecting from existing earthing to Distribution box complete.
M&L for Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
Supply and fix Illuminated Emergency Stop Button 22/25mm with two contacts (NO and NC) including connecting with enclosure complete all as specified and directed.
Supply and fix Revolving LED Flashing Unit with Siren, single phase, RED including connection with mounting arrangement complete all as specified and directed.
Supply and install hi wall split units indoor/outdoor complete with inverter technology, cordless remote control unit and in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2 Ton complete all as specified and directed.
Supply and fixing of voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variaiton between 170 volt to 250 volt with output voltage stabilised at 230 Volt with accuracy of ± 2.5% for 2 Ton AC complete all as specified and directed by Engr-in-charge
S & F in repairs, Multisensor detector (Smoke + Thermal) certified to EN-45 with base with galvanised steel, back box and all mounting accessories complete all as specified and directed
Supply & Replacement of ELECTRONIC HOOTER dual tone duly painted in red colour paint with ABS(Non Metalic) housing complete all as specified and directed. Make:- Ravel/RFS/FST
Replacement of Manual call points duly painted in red colour paint with ABS(Non Metalic) housing, The device shall have an LED which shall blink in normal state and get steady on activation to monitor the health status of the device. all as specified. Make:- Ravel/RFS/FST
Supply & Fixing wiring with 2 core 2.5 sqmm armoured multi stranded FRLS unsheathed PVC copper conductor cable 1100 Volts drawn in PVC concealed conduit including all accessories as required and connecting to Fire alarm panel to smoke detector, fire alarm and manual call point complete all as specified and directed.
Supply, install testing and commissioning “ FIRE ALARM CONTROL PANEL” system complete for 20 Zone complete with factory made vermin proof air tight zone control panel board made out of 16SWG CRCA sheet enclosure 100mm x 100mm surface type powder coated (Red Colour) (with arrangement comprising with annunciation system on Each floor, indicating ( Zones) 12/24 VDC stand by power supply with charger with auto change over device, panel having test/fault/failure control and indication/annunciation PCB, sound indicator for Each zone complete Make: Ravel/RFS/Apollo/System sensor
S & F Heat detector certified to EN-45 with base with galvanised steel, back box and all mounting accessories complete all as specified and directed
Supply & fix Response indicator as per existing model complete all as specified and directed.
M&L Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in soft / disintegrated rodk
M&L Chequered cement concrete tiles 20cm x 20cm x 25 cm thick, set, jointed and pointed with grey cement and pigment in floors including 15 mm thick screed in CM 1:6 complete all as specified and as directed.
M&L 100mm thick PCC type D-2, (1:4:8) using 40mm graded stone aggregate as in sub base all as specified and directed by Engr-in-Charge
M&L Hardcore of gauge n.exc. 63mm, deposited, spread and levelled in layers n.exc. 15cm thick, watered and rammed to a true surfacce.
Removing excavated materials (soft/ dis-integrated rock) to a distance n.exc. 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M/S jvsr constructions
M/s RAJ CONSTRUCTION
SHIVANI ENTERPRISES
JINTECH
M/S. M M S ENTERPRISES
Mehta and Co.
KIRAN TRADERS
K M SUBHANAIAH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .