Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC 296 SECTOR 15 PANCHKULA HARYANA | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹45.2 L+₹16.0 L (54.5%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹41.1 L+₹11.8 L (40.4%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | L3 | Rejected-Finance Not being lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Sept 2021, 6:00 pmClosed
GE Chandimandir
Garrison Engineer Chandimandir panchkula Haryana 134107
GE/CHM-43/2021-2022 REPAIR TO CEILING FANS / EXHAUST FANS/ WALL MOUNTING FANS AND GEYSERS SOLAR WATER HEATERS ETC IN MD /OTM ACCN AT CHANDIMANDIR
2021_MES_457047_2
GE/CHM-43/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Chandimandir
GE/CHM-43/2021-2022 REPAIR TO CEILING FANS / EXHAUST FANS/ WALL MOUNTING FANS AND GEYSERS SOLAR WATER HEATERS ETC IN MD /OTM ACCN AT CHANDIMANDIR
8 documents required · 8 mandatory
₹500
Garrison Engineer
₹90,000
Yes
24 Dec 2021
26 Aug 2021
28 Sept 2021
26 Aug 2021
21 Sept 2021
7 Sept 2021
Amount
Taking down geysers of any type and any capacity due to rusting of bolts/seepage of wall and re-installation at any location including S&F in repair of heavy duty pin type fastener 4 inch Job long and making necessary inlet/outlet electric & water supply connections from existing source to geyser complete all as specified and as directed
Inspection,checking adjustments and minor repairs of storage water heater 25/35/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :- (a) Inspection, taking out of drain plug & dewatering and refixing the same complete all as directed . (b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts. (d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow. (e) Checking and correct earth continuity of electrical items. (f) Checking functioning of heating element and correct setting adjustment of thermostat upto 55º C. (g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (h) The cost of spare parts required for repair & mainenance of geysers covered under this item shall be measured and paid separately under the relevant item. (j) Make of geysers covered under the scope of work :- Sidhson, bajaj, recold, crompton, orison, ditz premier, peeco, empire, shakti, sahas, konark Note : Irrespective of the Number of complaints, work against this item of BOQ shall be completed with in 24 hours after handing over the Complaint slip failing which recovery @ Rs 200/-/per geyser per day delay shall be effected from the contractors payment.
Supply only heating element, (Round type) 1.5 KW 230 volts, ISI marked suitable for 25/35/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA / Bajaj / Recold/Theta.
Supply only heating element, (Round type) 2 KW 230 volts, ISI marked suitable for 25/35/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA / Bajaj / Recold /Theta.
Supply only thermostat switch for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed. Make : USHA / Bajaj /Theta / Elcon.
Supply and fixing glass wool for geysers complete all as specified and as directed.
Supply only base assembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed.
Supply only indicator lamp for geyser of any type colour green & red complete all as specified and as directed. Make : Usha / Bajaj/ Crompton
Supply only stainless-steel inner tank of minimum 20 gauge sheet rated pressure not less than 7kg/sqcm suitable for 25/35 ltrs capacity geysers (wt not less than 3.75 kg) as per sample complete all as specified and as directed.
Supply only of stainless-steel inner tank of minimum 20 gauge sheet rated pressure not less than 7 Kg/sqcm suitable for 50 ltrs capacity geysers (wt not less than 5.25 kg) as per sample complete all as specified and as directed.
Supply only outer body of MS sheet not less than 20 gauge suitable for 25/35 ltr geyser with white synthetic enameled paints complete all as specified and as directed.
Supply only outer body of MS sheet not less than 20 gauge suitable for 50 ltr geyser with white synthetic enameled paint complete all as specified and as directed.
Supply only plug top 3 pin 15 Amp ISI marked complete all as specified and as directed. Make : SSK / CONA / FINE.
Supply only bottom cover of MS sheet 20 gauge suitable for 25/35 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
Supply only bottom cover of MS sheet 20 gauge suitable for 50 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
Supply and fix in renewal stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, chromium plated fancy type, screwed both ends for 15mm bore iron pipe or for union, ISI marked, complete all as specified and as directed.
Material and labour in renewal PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe complete all as specified and as directed. MAKE : PRAYAG/ POLYTUFF/ SHAKTI
Material and labour in renewal PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 600 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe complete all as specified and as directed. MAKE : PRAYAG/ POLYTUFF/ SHAKTI
Supply and fix in repair 3 core PVC insulated copper cable of size 40/0.0076 multi stranded complete all as specified and as directed. Make : Finolex/Paragon/Kalinga/L&T/ Plaza/Gold Medal/Havells/ HPL/Indo Asian
Supply and fix in renewal switch piano flush type, single pole, one way, 15 to 20 Amp complete all as specified and as directed. Make : SSK/ CONA /Fine /Havells/Gold Medal.
Supply and fix in renewal shuttered socket out let, 3 Pin, 16 Amp, 230 volts piano flush type complete all as specified and as directed. Make : SSK/ CONA /Fine /Havells/Gold Medal.
Supply and laying in floor, fixed to walls and ceiling, 25mm bore galvanised steel tubing medium grade, ISI marked, including fittings including taking down existing ucserviceable pipe, making good to floor, wall and ceiling as per existing complete all as specified and as directed.
All as per srl item No. 22 above but 20mm bore.
All as per srl item No. 22 above but 15mm bore.
Cutting and screwing existing steel water tubing 15/20/25 mm bore for addition /alteration required for connections to geysers etc complete all as specified and directed.
Material and labour for painting of outer surface of 25/35/50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed.
Supply and fix in replacement sheet metal enclosure single pole and neutral with 3 pin metal plug and socket complete with one single pole MCB 20 Amps, 230 volts complete all as specified and directed.
Supply and fix in renewal bib taps, cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for 15mm bore iron pipe, ISI marked, complete all as specified and as directed.
Supply and fix in renewal multiple safety system of instant geysers 1 & 3 Itr capacity complete all as specified and as directed.
Supply and fix in renewal heating element 3 KW to 4.5 KW of instant geysers 1 & 3 Itr capacity complete all as specified and as directed. . Make : Bajaj / Recold / USHA/Theta.
Dismantling carefully solar storage water heating system of any capacity, any type for following works with testing and refixing the same in original position making all water/ electric connection to entire satisfaction of Engineer-in-charge after repair as under :- (a) Inspection, opening, of all parts, descaling, washing of inner tank with chemical solution and cleaning of outer cover storage tank. (b) Checking water tightness of storage tank after cleaning. (c) Checking and correcting earth continuity of electrical items. (d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. Note : Supply and fixing of Spare parts. wiring etc shall be measured & paid separately.
Supply and fix heating element, 3.00 KW 230 volts, ISI marked suitable for solar geyers tank of any make complete all as specified and as directed. Make : USHA / Bajaj / Recold/ Daspas
Supply and fix thermostat switch for solar water heater (ISI marked) any make and size complete all as specified and as directed. Make : USHA / Bajaj /Theta / Elcon.
Repair and welded to stainless steel water storage tank of solar storage water heating systme of any capacity 100 to 500 LPD, to prevent any type of leakage at site with testig and refixing the same in original position makig all water / electric connection to entire satisfication of Engineer-in Charge after repair as under (a) Inspection, opening, of all parts, descaling, washing of inner tank with chemical solution and cleaning of outer cover storage tank. (b) Checking water tightness of storage tank after cleaning. (c) Checking and correcting earth continuity of electrical items. (d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. Note : Supply and fixing of Spare parts. wiring etc shall be measured & paid separately.
Material and labour for sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire, drawn through existing PVC surface/ concealed conduit and connected to main board and making good disturbed surface including taking down existing unserviceable wiring complete all as specified and as directed. Note: (i) Two run each of one RM of 4.00 sqmm cable and 1 run of one RM of 4.00 sqmm cable together shall be considered as 1 running meter for payment purpose.
Supply and fix in renewal safety plug suitable for solar water heating system solar tank of capacity 500 ltr complete all as specified and as directed.
Supply and fix in renewal glass collector suitable for solar water heating system of any size any make complete all as specified and as directed.
Supply and fix in replacement sheet metal enclosure DB's 240 Volts, IP-43, suitable for mounting MCB's, SPN, 2 way double door without bus bar complete all as directed by Engineer-in-charge.
Supply & Fix in replacement for MCB ,SP , 240 volt, 20Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engineer-in-charge. Make :-Havells Cat No DHMGCSPF020-032. or equivalent in ABB, L&T, C&S, Legrand, Standard
Supply & Fix in replacement MCB ,SPN , 240 volt,16- 32Amps 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engineer-in-charge. Make :-Havells Cat No DHMGCSNF16-032 or equivalent makes mentioned in ABB, L&T, C&S, Legrand, Standard
Supply & Fix in replacement metal plug top 2 pin 15 Amp ISI marked complete all as specified and directed. MAKE : HAVELLS/ LEGRAND /STANDARD
Supply & Fix in replacement metal socket 15 Amp ISI marked sutiable for plug top 2 pin 15 Amp complete all as specified and directed. MAKE : HAVELLS/ LEGRAND /STANDARD
Taking down existing Ceiling fan exhaust fan, wall fan of any type carefully from any differnt location for repair and kept safely and refixing the same after repair, complete all as specified and directed. Note :- Necessary T&P such as ladder, helper etc shall be arranged by the contractor.(Repairs & spares shall be measured and paid separately under respective item of sch 'A')
Material and labour for winding of motor of 1200 mm sweep ceiling fan of any make with super enameled copper winding wire of existing gauge (Approx wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.5 Sqmm of length not more than one meter with each fan including white synthetic enamel spray painting of fan and blade after rewinding complete all as specified and directed. Make of winding wire : New India/ Jindal/ Devidyal/ HTP Make of varnish : Doctor brand or equivalent. Make of Copper flexible wire : Plaza/Finolex/Kalinga Notes : (i) Other spares shall be measured and paid separately under respective item of Sch ‘A’. (ii) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. (iii) All repair/rewinding work will be carried out in MES Store yard/work shop only and mark the CA No with repair/rewinding date on the fan before handing over to the department and maintain the proper handing/taking record with date. Any fan repair/rewinding by contractor and found defective within waranty period i.e one year from the date of repair/rewinding the contractor will repair/ rewinding the same without any extra cost. (iv) Contractor will return the fan after rewinding and testing within 4 days from the date of taken over, if not a panelty @ rate of Rs 50/ fan per day will be charged.
All as per item 44 here-in-before but ceiling fan of 1400 mm sweep
All as per item 44 here-in-before but exhaust fan n. exc. 300 mm sweep.
All as per item 44 here-in-before but exhaust fan exc. 380 mm sweep.
All as per item 44 here-in-before but wall/air circulator fan 450 mm sweep.
All as per item 44 here-in-before but wall/air circulator fan exceeding 450 mm and not exceeding 600 mmsweep.
All as per item 44 here-in-before but Pedelstal fan n.exc 450 mm sweep.
All as per item 44 here-in-before but Pedelstal fan exceeding 450 mm and not exceeding 600 mm sweep.
Supply & fix in renewal capacitor AC 220/230 volts 2.5 mfd Make : Asian /Tyton/ Crompton Greaves/ Usha/Epcos.
All as per item 52 here-in-before but 3.15 mfd.
All as per item 52 here-in-before but 4 mfd.
All as per item 52 here-in-before but 6 mfd.
Supply & fix in renewal ball bearing No. 6200 Make : NBC /SKF (bearing with 8 balls shall only be used)
All as per item No 56 here-in-before but No. 6201
All as per item No 56 here-in-before but No. 6202
All as per item No 56 here-in-before but No. 6203
Supply & fixing in renewal rubber reel of fan with MS split clamp, two Nos nuts,bolts and washer complete set of appropriate size for hanging of ceiling fan complete all as specified and directed .
Supply and fixing in renewal old unserviceable armature shaft for ceiling fans of 1200/1400 mm sweep of any make complete all as specified and directed.
Supply & fixing in renewal fan blades (Set of three) made of aluminum suitable for 1200mm sweep ceiling fan of any make to match with existing colour with set of screws for one ceiling fan complete all as specified and directed .
Supply and fixing in renewal Fan blades (Set ot three) for 1400mm sweep ceiling fan made out of Aluminium suitable for any make with existing colour for one ceiiling fan with set of screws complete all as specified and directed.
Supply and fixing in renewal blades (set of three) for 300/380mm sweep exhaust fan made out of metal suitable for any make with existing colour with set of screws complete all as specified and directed.
Supply and fixing in renewal blades (set of three) of 450mm sweep exhaust fan made out of metal suitable for any make with existing colour with set of screws complete all as specified and directed.
Supply & fixing in renewal fan blades made of metal suitable of any make, sweep size with existing colour of table fan/pedestral fan etc with set of screws complete all as specified and directed .
Supply & fixing in renewal fan blades made of PVC suitable of any make, sweep size with existing colour of cabin fan/wall fan etc with set of screws complete all as specified and directed .
Supply & fixing in renewal of cover outer/inner suitable for any make , 450 mm sweep size with existing colour of cabin fan/ wall fan/air circulator fan made of GI with PVC coated etc with set of screws and tightening clip complete all as specified and directed.
Supply & fixing in renewal of cover outer/inner suitable for any make , 600 mm sweep size with existing colour of cabin fan/ wall fan/air circulator fan made of GI with PVC coated etc with set of screws and tightening clip complete all as specified and directed.
Supply & fixing in renewal of super quality louver shutters made out of aluminium for 450 mm sweep exhaust fan of any make complete all as specified and directed.
Supply & fixing in renewal down rod (of length not less than 45cm and not more than 60cm) made out of heavy grade M. S. pipe with necessary threading at both ends, holes as required painted to match with existing colour with hanging clamp for ceiling fan 1200/ 1400mm sweep complete all as specified and directed.
Supply & fixing in renewal down rod (of length not less than 75mm and not more than 90cm) made out of heavy grade M. S. pipe with necessary threading at both ends, holes as required painted to match with existing colour with hanging clamp for ceiling fan 1200/ 1400mm sweep complete all as specified and directed.
Supply and fixing in renewal of fan motor of PVC fresh air fan as per sample with existing colour suitable for 280/300 mm sweep complete all as specified and directed.
Labour only for serviceability check of ceiling fan of any size any make which includes the following:- (a) Functioning of the Fan. (b) Cleaning of Fan (c) Mechancal check i.e tightening of loose screw, nuts, bolts proper oiling after opening of strip and refix (d) Electrical check i.e Checking of connections Note:- (i) The above job shall be carried out by a trained electrician having ITI in elect, documentary proof of the education of tradesman shall be produced. (ii) Spare parts reqd to be replaced shall be paid under respective items as supplied and fixed (iii) Necessary T&P such as ladder, helper shall be contractors responsibility (iv) The above job will be carried out in entire Chandimandir Cantt and necessary documents showing qtr No, Bldg No supported with user sign shall be prepared by contractor as directed by Engineer in Charge.
Labour only for serviceability check of exhaust fan of any size any make which includes the following:- (a) Functioning of the Fan. (b) Cleaning of Fan after taking down. (c) Refixing of fan and mechancal check i.e tightening of loose screw, nuts, bolts (d) Electrical check i.e Checking of connections Note:- (i) The above job small be carried out by a trained electrician having ITI in elect, documentary proof of the education of tradesman shall be produced. (ii) Spare part reqd to be replaced shall be paid under respective items as supplied and fixed (iii) Necessary T&P such as ladder, helper shall be contractors responsibility (iv) The above work handover to contractor as and when site suggested by Engineer-in-Charge and should be completed within three days after issue of work site, failing which penalty charges @ 100/- per day shall be recovered
Supply & fixing in renewal upper & lower canopy (set of two) made of good quality PVC with tightening screws of required size for any make of ceiling fan complete all as specified and directed.
R N Enterprises
Ashok Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .